HD01 – HD06 0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER Features and Benefits Mechanical Data • • • • • • • • • Glass Passivated Die Construction Low Forward Voltage Drop Surge Overload Rating to 30A Peak Ideally Suited for Automated Assembly Miniature Package Saves Space on PC Boards UL Listed Under Recognized Component Index, File Number E94661 Lead Free Finish, RoHS Compliant (Note 1) Case: MiniDIP Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Finish ⎯ Tin. Plated Leads, Solderable per MIL-STD202, Method 208 Polarity: As Marked on Case Marking: Type Number, Date Code & Polarity Markings Weight: 0.125 grams (approximate) • • • • • Equivalent Circuit Ordering Information (Note 2) Device* HDxx-T Packaging MiniDIP Shipping 3K/Tape & Reel, 13-inch *xx = Device type, e.g. HD02-T or HD04-T, etc. Notes: 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes 2. For packaging details, visit our website at http://www.diodes.com. Marking Information YM HDxx Month Code Jan 1 Feb 2 HD01 – HD06 Document number: DS17003 Rev. 13 - 2 Mar 3 Apr 4 HDxx = Product Type Marking Code (ex: HD04) YM = Date Code Marking Y = Last Digit of the Year M = See Month/Code Table Below May 5 Jun 6 1 of 4 www.diodes.com Jul 7 Aug 8 Sep 9 Oct O Nov N Dec D December 2010 © Diodes Incorporated HD01 – HD06 Maximum Ratings @TA = 25°C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage Symbol VRMM VRWM VDC VRMS IO RMS Reverse Voltage Average Forward Rectified Current (Note 3) @TA = 40°C Non-Repetitive Peak Forward Surge Current, 8.3 ms Single Half Sine-Wave Superimposed on Rated Load HD01 HD02 HD04 HD06 Unit 100 200 400 600 V 70 140 280 420 0.8 V A 30 A IFSM Thermal Characteristics Characteristic Typical Thermal Resistance, Junction to Ambient (Note 3) Operating and Storage Temperature Range Symbol RθJA TJ, TSTG Value 75 -55 to +150 Unit °C/W °C Value 1.0 5.0 500 10 Unit V Electrical Characteristics @TA = 25°C unless otherwise specified Characteristic Instantaneous Voltage Drop @ 0.4A (per element) Peak Reverse Current at Rated @TA = 25°C DC Blocking Voltage (per element) @TA = 125°C Typical Total Capacitance (per element) (Note 4) IR CT 0.8 IF(AV), AVERAGE FORWARD CURRENT (A) μA pF 3. Mounted on PC Board. 4. Measured at 1.0 MHz and applied reverse voltage of 4.0V. IF, INSTANTANEOUS FORWARD CURRENT (A) Notes: Symbol VF 0.6 0.4 0.2 10 1.0 0.1 0.01 0 0 40 80 120 TA, AMBIENT TEMPERATURE (° C) Fig. 1 Output Current Derating Curve HD01 – HD06 Document number: DS17003 Rev. 13 - 2 160 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 2 Typical Forward Characteristics (per element) 2 of 4 www.diodes.com December 2010 © Diodes Incorporated HD01 – HD06 100 Tj = 25°C f = 1.0MHz 30 CT, TOTAL CAPACITANCE (pF) IFSM, PEAK FORWARD SURGE CURRENT (A) 35 20 10 10 1 0 1 1.0 10 100 NUMBER OF CYCLES AT 60 Hz Fig. 3 Maximum Peak Forward Surge Current (per element) 10 100 VR, REVERSE VOLTAGE (V) Fig. 4 Typical Total Capacitance (per element) 100 Tj = 125°C 10 1.0 T j = 25° C 0.1 0.01 0 40 20 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE (%) Fig. 5 Typical Reverse Characteristics (per element) Package Outline Dimensions L G A H B D E C J MiniDIP Dim Min Max A 5.43 5.75 B 3.6 4.0 C 0.15 0.35 D 0.05 0.20 E 7.0 ⎯ G 0.70 1.10 H 4.5 4.9 J 2.3 2.7 K 2.3 2.7 L 0.50 0.80 All Dimensions in mm K HD01 – HD06 Document number: DS17003 Rev. 13 - 2 3 of 4 www.diodes.com December 2010 © Diodes Incorporated HD01 – HD06 IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2010, Diodes Incorporated www.diodes.com HD01 – HD06 Document number: DS17003 Rev. 13 - 2 4 of 4 www.diodes.com December 2010 © Diodes Incorporated