AIMTEC AMSR1-7809-NZ Up to 12 watt | dc-dc converter Datasheet

Series AMSR1-78-NZ
Up to 12 Watt | DC-DC Converter
FEATURES:
•
•
•
•
3 Pin SIP Package
Pin-out compatible with LM78XX Linear Regulators
Short Circuit Protection
Non-Isolated Regulated Outputs
•
•
•
•
Operating temperature -40°C to +85°C
Wide input range
Very High Efficiency Up To 96%
Low ripple and noise
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Efficiency
Vin Max
(%)
Efficiency
Vin Min
(%)
4.75-28
6.5-32
9.0-32
12-32
16-32
3.3
5
6.5
9
12
1
1
1
1
1
90
93
94
95
96
83
88
90
92
94
AMSR1-783.3-NZ
AMSR1-7805-NZ
AMSR1-786.5-NZ
AMSR1-7809-NZ
AMSR1-7812-NZ
Input Specifications
Input Specifications
Voltage range
Filter
Quiescent Current
Short Circuit consumption
Nominal
Typical
Vin=(LL-HL) at full load
Maximum
See the table above
Capacitor
5
0.5
Units
VDC
7
1.2
mA
W
Maximum
Units
Output Specifications
Output Specifications
Voltage accuracy
Short Circuit protection
Short circuit restart
Output current limit
Thermal shutdown
Dynamic load stability
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Maximum Capacitive Load
Conditions
Typical
100% load
±3
Continuous.
Auto recovery
%
2
Internal IC junction
10-100% load
Vin=(LL-HL) at full load
10-100% load
-40°C to +85°C ambient
20MHz Bandwidth
2000
A
ºC
mV
%
%
%/oC
mV p-p
µF
Maximum
Units
100
KHz
o
C
o
C
o
C
150
±100
±0.4
±0.6
±0.02
35
General Specifications
Input Specifications
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Soldering Temperature
Conditions
Typical
100% load
With derating above 71°C
330
-40 to +85
-55 to +125
Free air convection
95
Non-conductive black plastic (UL94V-0 rated)
3.7
0.45 X 0.35 X 0.69 inch
11.50 X 8.90 X 17.50 mm
> 2 000 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25°C)
1.5 mm from case for 10 sec
300
%
g
o
C
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R8.D
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR1-78-NZ
Up to 12 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
Single
+Vin
GND
+Vout
Footprint
2.54
(0.10)
Dimensions
Ø 1.0 +0.15/-0
(Ø 0.04 + 0.006/-0
2.54
(0.10)
DIV: 2.54 (0.1)
Dimensions are typical values: mm (inch)
General Tolerance: ± 0.25 (± 0.01)
Pin Tolerance: ± 0.1 (± 0.004)
Derating
Free Air Convection
71º C
Output Power (%)
100
80
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R8.D
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR1-78-NZ
Up to 12 Watt | DC-DC Converter
Typical Application Circuit
Vin
1
3
AMSR1-78XX-NZ
C1
22µF
Vout
C2
100µF
2
GND
GND
C1: A low ESR capacitor is required to keep the noise of the converter to a minimum.
Ceramic capacitors are recommended, but tantalum or electrolytic may be used. Typical value is 22µF / 50V.
C2: Installation of C2 is recommended but optional. Typical recommended value is 100µF / 25V electrolytic.
NOTE: This part is not designed for parallel operation.
Recommended Circuits
Conducted and Radiated Emissions
L 12uH
TVS
SMCJ48A, 1500W
C1
1000uF/50V
C2
4.7uF/50V
+V input
+V output
DC/DC
Converter
- V input
Load
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.D
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only