TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Highlights & Features • • • • • • • Designed for single phase input 180-305Vac (for L-N) or 2 of 3-Phase system 2 x 180-550Vac (for L-L) or 254-780Vdc Compact and corrosion resistant aluminium casing Up to 90.0% efficiency and Power Boost of 120% for 3 seconds Wide operating temperature range from -30°C to +70°C Built-in constant current and hiccup during overload protection Built-in DC OK Contact Conformal coating on PCBAs to protect against common dust and chemical pollutants Safety Standards CB Certified for worldwide use Model Number: DRP-24V240W2BN Unit Weight: 0.81 kg (1.79 lb) Dimensions (L x W x D): 124 x 60 x 117 mm (4.88 x 2.36 x 4.61 inch) General Description The CliQ II DIN rail power supply series with a new model offering two phase 2 x 180-550Vac (for L-L) or single phase 180-305Vac (for L-N) for 24V/5A output. The DRP-24V240W2BN has safety approvals for single phase and two phase input according to IEC/EN/UL 60950-1 and UL 508 safety standards. The product features wide AC input voltage for single or two phase range. Such feature can protect the power supply from damage when user accidentally apply two phase input on the single phase power supply. Other advantages include reduced external input protection components and improved installation time since there is only two phase connection. The product performs under wide operating temperature from -30°C to 70°C with 2-Phase of 3-Phase application (for L-L). Conformal coating is applied on the PCBA to protect against common dust and chemical pollutant to withstand harsh industrial environments. Other major safety approvals included. Model Information CliQ II DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP-24V240W2BN 2 x 180-550Vac (2-Phase) 180-305Vac (Single Phase) 254-780Vdc 24Vdc 10.0A Model Numbering DR P– 24V DIN Rail Power Supply Output Voltage Output Power 1 240W 2 B N Two Phase CliQ II Series N - Metal Case, without Class I, Div 2 and ATEX All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Specifications Input Ratings / Characteristics Nominal Input Voltage 2 x 200-500Vac (2-Phase) 200-277Vac (Single Phase) Input Voltage Range 2 x 180-550Vac (2-Phase) 180-305Vac (Single Phase) Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz DC Input Voltage Range* 254-780Vdc Input Current < 2.00A @ 2 x 230Vac, < 1.00A @ 2 x 400Vac Efficiency at 100% Load > 90.0% @ 2 x 400Vac Max Power Dissipation 0% load 100% load < 8.5W @ 2 x 200Vac, < 9.5W @ 2 x 500Vac < 26.5W @ 2 x 200Vac, < 21.5W @ 2 x 500Vac Max Inrush Current (Cold Start) < 50A @ 2 x 200Vac & 2 x 500Vac Leakage Current < 3.5mA @ 500Vac *Safety approval according to IEC/EN/UL 60950-1. Output Ratings / Characteristics** Nominal Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc ± 2% Output Voltage Adjustment Range 24-28Vdc Output Current 10.0A (continuously operating at 24V) 12.0A (Power Boost for 3 seconds at 24V, refer to the details in the Functions section) Output Power 240W (continuously operating at 24V) 288W (Power Boost for 3 seconds at 24V, refer to the details in the Functions section) Line Regulation < 0.5% typ. (@ 200-550Vac input, 100% load) Load Regulation < 1% typ. (@ 200-550Vac input, 0-100% load) PARD*** (20MHz) < 150mVpp @ -10°C and above < 200mVpp @ below -10°C Rise Time < 100ms @ nominal input (100% load) Start-up Time < 1,000ms @ nominal input (100% load) Hold-up Time >18ms @ 2 x 230Vac (100% load) > 30ms @ 2 x 400Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 0-100% load Start-up with Capacitive Loads 10,000µF Max Functional DC OK Relay Contact 30V / 1A Max The relay is usually closed when the output is normal **For power de-rating from 50°C to 70°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1μF ceramic capacitor & 47μF electrolytic capacitor. 2 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Mechanical Case Cover / Chassis Aluminium Dimensions (L x W x D) 124 x 60 x 117 mm (4.88 x 2.36 x 4.61 inch) Unit Weight 0.81 kg (1.79 lb) Indicator Green LED (DC OK) Cooling System Terminal Wire Convection Input 3 Pins (Rated 600V/35A) Output 4 Pins (Rated 300V/28A) Input Output AWG 18-8 AWG 16-12 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 40dBA Environment Surrounding Air Temperature Power De-rating Operating -30°C to +70°C Storage -40°C to +85°C Vertical Mounting Horizontal Mounting Input Voltage > 50°C de-rate power by 2.25% / °C > 30°C de-rate power by 2% / °C < 200Vac de-rate power by 0.5% / Vac Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,500 Meters (8,200 ft.) for ITE application (@ 50°C) 0 to 2,000 Meters (6,560 ft.) for Industrial application (@ 50°C) Shock Test Non-Operating IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total Vibration Non-Operating IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction Over Voltage Category III Pollution Degree 2 According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) Protections Overvoltage 32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent > 120-180% of rated load current, Constant current, Hiccup Mode (Auto-Recovery) Over Temperature < 80°C Surrounding Air Temperature @ 100% load, NonLatching (Auto-Recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Internal Fuse T3.15A Degree of Protection IP20 Protection Against Shock Class I with PE* connection *PE: Primary Earth 3 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Reliability Data MTBF > 500,000 hrs. as per Telcordia SR-332 I/P: 2 x 200Vac & 500Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (2 x 200Vac & 500Vac, 50% load @ 40°C) Safety Standards / Directives Electrical Equipment of Machines EN 60204-1 (over voltage category III) Electrical Equipment for Use in Electrical Power Installations IEC/EN 62477-1 / IEC 62103 Safety Entry Low Voltage PELV* (EN 60204-1), SELV (EN 60950-1) Electrical Safety Industrial Control Equipment SIQ Bauart UL/cUL recognized CB scheme UL/cUL listed CSA CE Material and Parts Galvanic Isolation EN 60950-1 UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) In conformance with EMC Directive 2014/30/EU (only AC input) and Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU Compliant (EN 50581) Input to Output 4.0KVac Input to Ground 2.0KVac Output to Ground 1.5KVac *Output must be earthed in the final unit in order to comply with PELV requirements according to standard EN 60204-1. 4 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN EMC Emissions (CE & RE) CISPR 22, EN 55022, CISPR 11, EN 55011, FCC Title 47: Class B Component Power Supply for General Use EN 61204-3 Immunity Generic Standards: EN 55024, EN 61000-6-2 1) Electrostatic Discharge IEC 61000-4-2 Radiated Field IEC 61000-4-3 Level 4 Criteria A Air Discharge: 15kV Contact Discharge: 8kV Level 3 Criteria A1) 80MHz-1GHz, 10V/M, 80% modulation (1kHz) 1.4GHz-2GHz, 3V/M, 80% modulation (1KHz) 2GHz-2.7GHz, 1V/M, 80% modulation (1KHz) Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Conducted IEC 61000-4-6 Level 3 Criteria A 2) Common Mode : 2kV Differential Mode3): 1kV Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 1) 1) Criteria A 30A/Meter Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Harmonic Current Emission Level 3 Criteria A1) 2) Common Mode : 2kV Differential Mode3): 1kV IEC/EN 61000-3-2, Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 5 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Block Diagram Device Description 1) 2) 3) 4) 5) 6 Input terminal block connector Output terminal block connector DC Voltage adjustment potentiometer DC OK LED (Green) Universal mounting rail system All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Dimensions L x W x D: 124 x 60 x 117 mm (4.88 x 2.36 x 4.61 inch) Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. 2. 3. 4. 5. Fig. 1 De-rating for Vertical Mounting Orientation > 50°C de-rate power by 2.25% / °C Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature >50°C (Vertical) or >30°C (Horizontal), the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please contact [email protected] for more details. De-rating for Horizontal Mounting Orientation > 30°C de-rate power by 2% / °C 7 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Output Load De-rating VS Input Voltage No output power de-rating for the input voltage range from 200Vac to 550Vac Assembly & Installation The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. For Vertical Mounting, the device should be installed with input terminal block at the bottom. For Horizontal Mounting, the device should be installed with input terminal block on the left side. Each device is delivered ready to install. Mounting Dismounting Fig. 2.1 Mounting Fig. 2.2 Dismounting Snap on the DIN rail as shown in Fig. 2.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. 4. Shake the unit slightly to ensure that it is secured. To uninstall, pull or slide down the latch with screw driver as shown in Fig. 2.2. Then slide the power supply unit (PSU) in the opposite direction, release the latch and pull out the power supply unit (PSU) from the rail. In accordance to EN 60950 / UL 50950, flexible cables require ferrules. Use appropriate copper cables designed to sustain operating temperature of: 1. 60°C, 60°C / 75°C for USA 2. At least 75°C for ambient not exceeding 30°C, and 90°C for ambient exceeding 30°C for Canada. 8 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Safety Instructions • • • • • • • • • • 9 Vertical Mounting Horizontal Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, please refer to the following instructions to ensure sufficient clearance around the device. Vertical Mounting: 50mm (1.97 inch) above and below the device as well as a lateral distance of 5mm (0.20 inch) to other units. Horizontal Mounting: 50mm (1.97 inch) above and below the device as well as a lateral distance of 50mm (1.97 inch) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! The main power must be turned off before connecting or disconnecting wires to the terminals. DO NOT insert any objects into the unit. Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. The power supplies unit should be installed in minimum IP54 rated enclosure. The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. CAUTION: Double pole/neutral fusing. CAUTION: “For use in a controlled environment”. All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Functions ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. 10 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Power Boost Power Boost is the reserve power available constantly that allows reliable startup to support sudden and short spike of loads with high inrush current typically during turn on to remove the need of more expensive higher rated power supply unit. After the output has reached its steady state set value, the power supply can support surge loads with a higher short-term power demand up to 120% of maximum rated load (IO Max), for a maximum duration of 3 seconds. The Power Boost is also available to repeatedly basis with according to the condition of an average (R.M.S) output power shall not exceed continuous operating condition or refer to duty cycle calculation below. 𝐷𝑢𝑡𝑦 𝑐𝑦𝑐𝑙𝑒 (%) = 𝑇𝑃 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 𝐴𝑣𝑒𝑟𝑎𝑔𝑒 𝑂𝑢𝑡𝑝𝑢𝑡 𝑃𝑜𝑤𝑒𝑟 (𝑃𝐴𝑣𝑔 ) = OR 𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟 = (𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇𝑃 ) + (𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟 × 𝑇𝑁 ) 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 �𝑃𝐴𝑣𝑔 × 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒� − (𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇𝑃 ) 𝑇𝑁 An example of Power Boost and Average Output Power Power Boost Peak Power (WP) Power Boost Duration (TP) Duty Cycle Non-Peak Power (WN) Non-Peak Power Duration (TN) Total Time (T) 120% 288 3 sec 10% 235W 27 sec 30 sec 120% 288 3 sec 15% 232W 17 sec 20 sec It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause damage to the PSU. External Input Protection Device The unit is protected at the L pin, with an internal fuse that cannot be replaced. The power supply has been tested and approved on 20A (UL) and 16A (IEC) branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, or, utilized, please refer a minimum value in instruction sheet with B or C characteristic breaker. 11 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Auto-Recovery) The power supply’s Overcurrent (OCP) Protection will be activated when output current is > 13A typ. In such occurrence, the VO will start to droop and once the output voltage is below 18Vdc typ., the power supply will go into “Hiccup mode” (AutoRecovery). The power supply will recover once the fault condition of the OCP is removed and IO is back within the specifications. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Over Temperature Protection (Auto-Recovery) Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 12 As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the derating graph. All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Operating Mode Redundant Operation In order to ensure proper redundant operation for the power supply unit (PSU), the output voltage difference between the two units must be kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to set them up for the redundant operation: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect the power supply to 50% of rated load, and set the PSU 1 and PSU 2 output voltage. Fig. 3 Redundant Operation Connection Diagram Step 2. Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20A) module shown on the diagram on the right. Step 3. Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. Parallel Operation The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. Fig. 4 13 Parallel Operation Connection Diagram All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 240W 2 Phase / DRP-24V240W2BN Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. Conformal Coating The Protective Coating Technology Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere. PFC – Norm EN 61000-3-2 Line Current Harmonic content Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. 14 All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01)