Description
The ARH Series of DC-DC converters has been designed
specifically for use in the hostile environments The high
level of radiation tolerance inherent in the ARH design is
the result of extensive research, thorough analysis and
testing and of careful component specification. Designed
to supplement the triple output configuration provided by
the ART Series, the ARH circuit topology is the follow-on
to the successful ART design and incorporates many of
the design features characterizing that product line. Capable of
uniform high performance over long term exposures in
radiation intense environments, this series expands the
standard for distributed power systems demanding high
performance and reliability in the harsh environments.
The ARH converters are hermetically sealed in a rugged,
low profile package utilizing copper core input and output
pins to minimize resistive DC losses. Long-term hermetically
is assured through use of parallel seam welded lid attachment
along with rugged ceramic pin-to-package seal. Axial orientation
of the leads facilitates preferred bulkhead mounting placing the
converter on the principal heat-dissipating surface.
Features

















Total Dose > 100 kRads(Si), 2:1 Margin
SEE Hardened to LET up to 83 MeV.cm2/mg
De-rated per MIL-STD-975 & MIL-STD-1547
Output Power to 30 Watts
Regulates to No-Load
18 to 50 Volt Input Range
Input Under voltage Lockout
Fully Characterized from -55°C to +125°C
Continuous Short Circuit Protection
12.8 W/in3 Output Power Density
True Hermetic Package
External Inhibit Port
Externally Synchronization
Fault Tolerant Design
Available with Outputs from 2.5V to 15V
Overload Protection
Standard Microcircuit Drawings Available
Manufactured in a facility fully qualified to MIL-PRF-38534, these
converters are fabricated utilizing DLA Land and Maritime
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening specifications
can be accommodated. Contact IR HiRel San Jose for special
requirements.
1
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Specifications
Absolute Maximum Ratings Note 1
Input voltage range
Soldering temperature
Storage case temperature
Recommended Operating Conditions Note 2
-0.5VDC to +80VDC
Input voltage range
300°C for 10 seconds Output power
-65°C to +135°C
Operating case temperature
+18VDC to +60VDC
+18V to +50V for full de-rating to
MIL-STD-1547
0 to 30W
-55°C to +125°C
-55°C to +85°C for full de-rating to
MIL-STD-975
Static Characteristics -55°C ≤ TCASE ≤ +125°C, VIN = 28VDC ± 5%, CL= 0, unless otherwise specified.
Parameter
Symbol
Output voltage
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
VOUT
Output power
POUT
Output current
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Test Conditions
POUT = 30W, TC = +25°C
18VDC < VIN < 50VDC
IOUT
18VDC < VIN < 50VDC
Limits
Min.
Max.
Unit
2.487
3.283
4.975
5.174
11.940
14.925
2.513
3.317
5.025
5.226
12.060
15.075
VDC
0
30
W
0
0
0
0
0
0
12000
9090
6000
5770
2500
2000
mADC
Line regulation
Note 3
VRLINE
18 VDC < VIN < 50VDC, 0 < IOUT < IMAX
-1.0
+1.0
%
Load regulation
Note 4
VRLOAD
18 VDC < VIN < 50VDC, 0 < IOUT < IMAX
-2.0
+2.0
%
Total regulation
VR
All conditions of Line, Load, Temperature,
Radiation and End of Life
-4.0
+4.0
%
No-load input current
IIN
IOUT = 0 (Pin 3 open)
inhibited (Pin 3 shorted to pin 2)
—
—
100
8.0
mA
Output ripple and noise voltage
Note 5
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
VRIP
18 VDC < VIN < 50VDC, IOUT = IMAX
Input ripple current
IRP
18 VDC < VIN < 50VDC, IOUT = IMAX
FS
Synchronization input open. (pin 6)
Switching frequency
Note 5
225
30
30
40
40
50
50
mVp.p
100
mApp
275
kHz
For Notes to Electrical Performance Characteristics, refer to page 4
2
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Static Characteristics (Continued) -55°C ≤ TCASE ≤ +125°C,VIN = 28VDC ± 5%, CL =0, unless otherwise specified.
Parameter
Symbol
Test Conditions
Limits
Min.
Max.
Unit
Efficiency
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Enable input
open circuit voltage
drive current (sink)
voltage range
EFF
IOUT = IMAX, TC = +25°C
V
A
V
225
3.5
-0.5
40
20
310
10
0.25
80
kHz
V
V
V/s
%
3.7
4.3
V
-0.5
External clock signal on
Sync. input (pin 4)
Synchronization output
pulse high level
Signal compatible with
Synchronization Input
PD
VTLD
TTLD
VTLN
10
12
9.5
Short circuit on output
50% Load  100% load
-200
-200
-200
-200
-300
-350
200
200
200
200
300
350
200
200
200
200
200
200
50% Load  100% load
IOUT = IMAX, VIN = 18 V to/from 50 V
%
5.0
100
50
3.0
Synchronization input
frequency range
pulse high level
pulse low level
pulse rise time
pulse duty cycle
Power dissipation, short circuit
ARH2802R5S
ARH2803R3S & ARH2805S
All Others
Output response to step load changes
Note 8
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Recovery time from step load changes
Notes 8, 9
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Output response to step line changes
Notes 7, 10
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
72
75
76
76
80
80
-180
-180
-250
-250
-450
-900
180
180
250
250
450
900
W
mVPK
s
mVPK
For Notes to Electrical Performance Characteristics, refer to page 4
3
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Static Characteristics (Continued) -55°C ≤ TCASE ≤ +125°C,VIN = 28VDC ± 5%, CL =0, unless otherwise specified.
Parameter
Symbol
Test Conditions
Recovery time from step line
changes
Notes 7, 9, 10
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
TTLN
IOUT = IMAX, VIN = 18 V to/from 50 V
Turn on overshoot
VOS
IOUT = 10% or 100% of IMAX
TDLY
IOUT = 10% or 100% of IMAX
Turn on delay
Note 11
Capacitive load
Notes 6, 7
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
CL
No effect on DC performance
Isolation
ISO
500VDC input to output or
Any pin to case
Recovery from a short circuit
VR
Output shorted, then open into max
rated load current. Vin = 28V
OVLD
Maximum current at specified
output voltage
Overload trip current
Limits
Min.
Max.
600
600
700
700
320
400
2.0
s
5.0
% VOUT
20
ms
1200
1200
1000
1000
180
120
µF
100
M
10
105
Unit
135
% of rated
output
voltage
% of max
output
current
Notes to Specifications
1. Operation outside absolute maximum/minimum limits may cause permanent damage to the device. Extended operation at the limits
may permanently degrade performance and affect reliability.
2. Device performance specified in Electrical Performance table is guaranteed when operated within recommended limits. Operation
outside recommended limits is not specified.
3. Parameter measured from 28V to 18V or to 50V while load remains fixed at 10%, 50% and 100% of Imax.
4. Parameter measured from 50% to 10% or 100% of maximum load conditions while line remains fixed at 18, 28 or 50 volts.
5. Guaranteed for a bandwidth of DC to 20 MHz. Tested using a 20 KHz to 2.0 MHz bandwidth.
6. A capacitive load of any value from 0 to the specified maximum is permitted without compromise to DC performance. A capacitive
load in excess of the maximum limit may interfere with the proper operation of the converter’s short circuit protection, causing
erratic behavior during turn on.
7. Parameter is tested as part of design characterization or after design or process changes. Thereafter, parameters shall be
guaranteed to the limits specified in the table.
8. Load transient rate of change, di/dt  2.0 A/µs.
9. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.
10. Line transient rate of change, dv/dt  50 V/µs.
11. Turn on delay time is for either a step application of input power or a logical low to high transition on the enable pin (pin 3) while
power is present at the input.
4
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Group A Tests VIN = 28V, CL = 0 unless otherwise specified.
Parameter
Symbol
Output voltage accuracy
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
VOUT
Output power
POUT
Note 1
Output current
Note 1
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Output regulation
Note 4
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
No Load Input Current
Output ripple
Note 2
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Switching frequency
Input ripple
Note 2
Recovery from a short circuit
Overload trip current
Test Conditions
IOUT = IMAX , TC = 25°C
VIN = 18 V, 28V, 50 V
VIN = 18 V, 28V, 50 V
IOUT
VR
IIN
Group A
Subgroups
Unit
1
2.487
3.283
4.975
5.174
11.940
14.925
2.513
3.317
5.025
5.226
12.060
15.075
V
1, 2, 3
0
30
W
0
0
0
0
0
0
12000
9090
6000
5770
2500
2000
2.425
3.201
4.850
5.044
11.640
14.550
2.575
3.399
5.150
5.356
12.360
15.450
V
100
8.0
mA
1, 2, 3
IOUT = 10%, 50%, 100% of IMAX
VIN = 18 V, 28V, 50 V
1, 2, 3
IOUT = 0, Pin 3 open
Pin 3 shorted to pin 2 (disabled)
Limits
Min.
Max.
1, 2, 3
1, 2, 3
VRIP
VIN = 18 V, 28V, 50 V
IOUT = IMAX
1, 2, 3
FS
Synchronization pin (pin 6) open
4, 5, 6
IRIP
VIN = 18 V, 28V, 50 V
IOUT = IMAX
1, 2, 3
VR
Output shorted, then open into
max rated load current. VIN = 28 V
OVLD
Maximum current at specified
output voltage
30
30
40
40
50
50
225
105
mVP-P
275
kHz
100
mAP-P
5.0
1, 2, 3
mA
135
% of
rated
output
voltage
% of
max
output
current
For Notes to Group A Tests, refer to page 6.
5
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Group A Tests (Continued) VIN = 28V, CL = 0 unless otherwise specified.
Parameter
Symbol
Test Conditions
Group A
Subgroups
Limits
Min.
Max.
Unit
Efficiency
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Power dissipation,
Short circuit
ARH2802R5S
ARH2803R3S & ARH2805
All Others
Output response to step load
changes
Note 5
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Recovery from step load
changes
Notes 5, 6
ARH2802R5S
ARH2803R3S
ARH2805S
ARH2805R2S
ARH2812S
ARH2815S
Turn on overshoot
Turn on delay
Note 7
Isolation
1
EFF
IOUT = IMAX
2, 3
PD
VTL
Short circuit across output
50% Load to/from 100% load
72
75
76
76
80
80
68
68
72
72
78
78
10
12
9.5
1, 2, 3
4, 5, 6
%
-200
-200
-200
-200
-300
-350
200
200
200
200
300
350
200
200
200
200
200
200
TTL
50% Load to/from 100% load
4, 5, 6
VOS
IOUT = 10% and 100%
4, 5, 6
TDLY
IOUT = minimum and full rated
4, 5, 6
2.0
ISO
500VDC Input to output or any
pin to case (except pin 12)
1
100
W
mVPK
µs
5.0
%VOUT
20
ms
M
Notes to Specifications Tables
1.
2.
3.
4.
5.
6.
7.
8.
6
Parameter verified during dynamic load regulation tests.
Guaranteed for DC to 20 MHz bandwidth. Test conducted using a 20 Hz to 2.0MHz bandwidth.
Deleted.
Output is measured for all combinations of line and load. Only the minimum and maximum readings for the output are recorded.
Load step transition time is 10s.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.
Turn on delay time is tested by application of a logical low on high transition on the enable pin (pin 3) with power present at the input.
Subgroups 1 and 4 are performed at +25°C, subgroups 2 and 5 at +85°C and subgroups 3 and 6 at -55°C.
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Fig I. Block Diagram
Circuit Operation and Application Information
The ARH28XXXXS Series of converters have been designed
using a single ended forward switched mode converter
topology. (Refer to Fig I.) Single ended topologies enjoy
certain advantages in radiation hardened designs in that
they eliminate the possibility of simultaneous turn on of
both switching elements during a radiation induced upset.
In addition, single ended topologies are not subject to
transformer saturation problems often associated with
double ended implementations.
The design incorporates a two-stage LC input filter to attenuate
input ripple current. A low overhead linear bias regulator
provides both a bias voltage for the converter primary
control logic and a stable, well-regulated reference for the
error amplifier. Output control is realized using a wide
band discrete pulse width modulator control circuit incorporating a
unique non-linear ramp generator circuit. This circuit
helps stabilize loop gain over variations in line voltage for
superior output transient response. Nominal conversion
frequency has been selected as 250 kHz to maximize
efficiency and minimize magnetic element size.
Output voltages are sensed and fed back to the controller
using a patented magnetic feedback circuit. This circuit is
designed to be relatively insensitive to variations in temperature,
aging, radiation and manufacturing tolerances making it
particularly well suited to radiation hardened designs. The
control logic has been designed to use only radiation tolerant
components, and current paths include series resistances
to limit photocurrents.
7
Other key circuit design features include output short circuit and
overload protection, input under voltage lockout and an
external synchronization input port, permitting operation at
an externally set clock rate. Alternately, a synchronization output
is provided to lock frequencies with another converter
when using more than one converter in a system.
Thermal Considerations
The ARH Series of converters is capable of providing relatively
high output power from a package of modest volume. The
power density exhibited by these devices is obtained by
combining high circuit efficiency with effective methods of
heat removal from the die junctions. Good design practices have
effectively addressed this requirement inside the device.
However when operating at maximum loads, heat generated at
the die junctions depends upon minimally restricted thermal
conduction from the base plate for that heat to be carried
away. To maintain case temperature at or below the
specified maximum of 125°C, this heat can be transferred
by attachment of the ARH28XXXXS to an appropriate heat
dissipater held in intimate contact with the converter base-plate.
Effectiveness of this heat transfer is dependent on the
intimacy of the baseplate to heat sink interface. It is therefore
suggested that a heat-transferring medium possessing
good thermal conductivity be inserted between the baseplate and
heat sink. A material utilized at the factory during testing
and burn-in processes is sold under the trade name of Sil-Pad
4001.This particular product is an insulator but electrically
conductive versions are also available. Use of these materials
assures optimum surface contact with the heat dissipater
by compensating for minor surface variations.
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
While other available types of heat conducting materials
and thermal compounds provide similar effectiveness,
these alternatives are often less convenient and are
sometimes messy to use.
When inhibited outputs are desired, a logical “low” on this
port will shut he converter down. An open collector
device capable of sinking at least 100 µA connected to
enable pin 3 will work well in this application.
A conservative aid to estimating the total heat sink surface area
(AHEAT SINK) required to set the maximum case temperature rise
(T) above ambient temperature is given by the following expression:
A benefit of utilization of the enable input is that following an
initial charge of the input capacitor, subsequent turn-on
commands will induce no uncontrolled current inrush.
A HEAT SINK
Where
 T 

0.85 
 80 P 
1.43
 5.94
Figure II. Enable Input Equivalent Circuit
T  Case temperature rise above ambient
 1

P  Device dissipation in Watts  POUT 
 1
 Eff

As an example, assume that it is desired to maintain the
case temperature of an ARH2815S at +65°C or less while
operating in an open area whose ambient temperature
does not exceed +35°C; then
T = 65 - 35 = 35°C.
From the Specification Table, the worst case full load efficiency
for this device is 80%; therefore the maximum power dissipation
at full load is given by
 1

P  30  
 1  30  0.25  7.5W
 .80 
and the required heat sink area is
A
HEAT SINK
35


=
0.85 
 80  7.5 
Synchronization
1.43
. in 2
 5.94  318
Thus, a total heat sink surface area (including fins, if any)
of approximately 32 in2 in this example, would limit case
rise to 35°C above ambient. A flat aluminum plate, 0.25"
thick and of approximate dimension 4" by 4" (16 in2 per
side) would suffice for this application in a still air environment.
Note that to meet the criteria, both sides of the plate require
unrestricted exposure to the ambient air. The user should
remember that when operating in the vacuum of space,
this method does not apply and all heat must be conducted away
from the attaching surface.
1
Sil-Pad is a registered Trade Mark of Bergquist, Minneapolis, MN
Inhibiting Converter Output
As an alternative to application and removal of the DC
voltage at the input, the user can control the converter
output by providing an input referenced, TTL compatible,
logic signal to the enable pin 3.This port is internally
pulled “high” so that when not used, an open connection
on the pin permits normal converter operation.
8
When using multiple converters, system requirements
may dictate operating several converters at a common
system frequency. To accommodate this requirement, the
ARH28XXXXS type converter provides a synchronization
input port.
The sync input port permits synchronization of an ARH
converter to any compatible external frequency source
operating in the band of 225 to 310 kHz. In the event of
failure of an external synchronization source, the converter will
revert to its own internally set frequency. When external
synchronization is not desired, the sync in port may be left
open (unconnected) permitting the converter to operate at its own
internally set frequency.
When an external frequency source is not available, an
internal clock signal is provided through appropriate buffering at
the sync out port. This port can drive a minimum of 3
ARH sync in ports thereby allowing all to operate at the
same clock frequency.
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Output Short Circuit Protection
EMI Filtering
Protection against accidental short circuits on the output is
provided in the ARH28XXXXS converter. This protection is
implemented by sensing primary switching current and reducing
the switching pulse widths when a short occurs. The output
current is therefore limited to a maximum value, which protects
the converter. Under this condition the internal power
dissipation is nearly the same as for maximum loading.
Although the internal filtering provided at both input and
output terminals of the ARH Series converters is sufficient
for most applications, some critical applications may require
additional filtering in order to accommodate particular system
requirements.
Input Under voltage Protection
A minimum voltage is required at the input of the converter to
initiate operation. This voltage is set to a nominal value of
16.8 volts. To preclude the possibility of noise or other
voltage variations at the input falsely initiating and halting
converter operation, a hysteresis of approximately 1.0
volts is incorporated into this circuit. The converter is
guaranteed to operate at 18 Volts input under all specified
conditions.
Input Filter
To attenuate input ripple current, the ARH28XXXXS Series
converters incorporate a two-stage LC input filter illustrated in Fig.
III following. The elements of this filter comprise the dominant input load impedance characteristic, and therefore
determine the nature of the current inrush at turn-on.
While the internal input filter maintains input ripple current
below 50mAp-p, an external filter can be applied to further
attenuate this ripple to a level below the CE03 limits imposed by
MIL-STD-461. International Rectifier currently supplies such a filter
housed in a complementary package. The catalog number of this
part is ARF461.
Output Noise
When attempting noise measurement at the output of
switching converters, measurement techniques employed
can have a significant influence on results during these
tests. Any noise measurements should be undertaken
only with test leads dressed as close to the device output
pins as is physically possible. Probe ground leads should
be kept to a minimum (<< 1") length to minimize the influence of
parasitic impedances on results.
Figure III. Input Filter
9
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Radiation Performance
The radiation tolerance characteristics inherent in the ARH28XXXXS converters are a result of a carefully planned ground-up
design program with specific radiation design goals. Identification of the general circuit topology, a fundamental task in design
effort, was followed by selection of appropriate elements from a list of devices for which extensive radiation effects data was
available. By imposing sufficiently large margins on those electrical parameters showing the worst case degrading effects
of radiation, designers were able to select appropriate elements for incorporation into the circuit. Existing radiation data
was utilized for input to PSPICE and Rad SPICE in the generation of circuit performance verification analyses. Thus, electrical
performance capability under all environmental conditions including radiation was well understood before first application of power
to the inputs.
A principal design goal was achieving a converter topology that, because of large design margins, had radiation performance essentially
independent of radiation induced element-lot performance variations. Where such margins cannot be assured, element lots
are either selected following RLAT characterization as radiation hard devices or, purchased as radiation hard devices so
that realization of the design goals are maintained.
The following table specifies guaranteed minimum radiation exposure levels tolerated while maintaining specification limits.
Radiation Specification Tcase = 25°C
Parameter
Condition
Min
Typ
Max
Unit
Total Ionizing Dose (2 :1 Margin)
MIL-STD-883, Method 1019.4
Operating bias applied during exposure
100
kRads (Si)
Dose Rate
Temporary Saturation
Survival
MIL-STD-883, Method 1021
1E8
1E11
Rads(Si)/sec
(Single event effects)
BNL Dual Van de Graf Generator
83
MeV·cm2/mg
Heavy Ion
IR HiRel currently does not have a DLA certified Radiation Hardness Assurance Program.
Standard Quality Conformance Inspections on ARH28XXXXS Series (Flight Screened)
Inspection
Application
Samples
Group A
Part of screening on each unit
100%
Group B
Each inspection lot
* 5 units
Group C
First inspection lot or following class 1 change
10 units
Group D
In line (Part of element evaluation)
3 units
* Group B quantity for option 2 End of Line QCI. No Group B samples required for Option 1, In-line.
10
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Mechanical Outline
Note:
1. Dimensions are in inches.
2. Base Plate Mounting Plane Flatness 0.003 maximum.
3. Unless otherwise specified, tolerances are

= ± 2°
.XX
= ± .01
.XXX
= ± .005
4. Device Weight - 120 grams maximum.
Pin Designation
11
Pin #
Designation
Pin #
Designation
1
+ Input
8
Case Ground
2
Input Return
9
-Sense
3
Enable
10
+ Sense
4
Sync In
11
+V Output
5
Sync Out
12
+V Output
13
Output Return
14
Output Return
Standard Microcircuit Drawing
Equivalence Table
Standard Microcircuit
Drawing Number
IR Hirel Standard
Part Number
5962-04232
ARH2805S
5962-04233
ARH2803R3S
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
Device Screening
Requirement
MIL-STD-883 Method
No Suffix 
CK 
EM 
Temperature Range
—
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
Element Evaluation
MIL-PRF-38534
Class K
Class K
N/A
Non-Destructive Bond Pull
2023
Yes
Yes
N/A
Internal Visual
2017
Yes
Yes

Temperature Cycle
1010
Cond C
Cond C
Cond C
Constant Acceleration
2001, Y1 Axis
3000 Gs
3000 Gs
3000 Gs
PIND
2020
Cond A
Cond A
N/A
Burn-In
1015
320 hrs @ 125°C
(2 x 160 hrs)
320 hrs @ 125°C
(2 x 160 hrs)
48 hrs @ 125°C
Final Electrical
(Group A)
MIL-PRF-38534
& Specification
-55°C, +25°C,
+85°C
-55°C, +25°C,
+85°C
-55°C, +25°C,
+85°C
PDA
MIL-PRF-38534
2%
2%
N/A
Seal, Fine and Gross
1014
Cond A, C
Cond A, C
Cond A
Radiographic
2012
Yes
Yes
N/A
External Visual
2009
Yes
Yes

Notes:
 Best commercial practice.
 CK is a DLA class K compliant without radiation performance. No suffix is a radiation rated device but not available as
a DLA qualified SMD per MIL-PRF-38534.
 Any Engineering Model (EM) build with the “EM” Suffix shall only be form, fit and functional equivalent to its
Flight Model (FM) counterpart, and it may not meet the radiation performance. The EM Model shall not be expected
comply with MIL-PRF-38534 flight quality/workmanship standards, and configuration control. An EM build may use
electrical equivalent commercial grade components. IR HiRel will provide a list of non-compliance items upon request.
Part Numbering
IR HiRel Headquarters: 101 N. Sepulveda Blvd., El Segundo, California 90245, USA Tel: (310) 252-7105
IR HiRel Leominster: 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776
IR HiRel San Jose: 2520 Junction Avenue, San Jose, California 95134, USA Tel: (408) 434-5000
Data and specifications subject to change without notice.
12
2016-06-29
ARH28XXXXS SERIES
(28V Input, Single Output)
IMPORTANT NOTICE
The information given in this document shall be in no event regarded as guarantee of conditions or characteristic. The
data contained herein is a characterization of the component based on internal standards and is intended to
demonstrate and provide guidance for typical part performance. It will require further evaluation, qualification and
analysis to determine suitability in the application environment to confirm compliance to your system requirements.
With respect to any example hints or any typical values stated herein and/or any information regarding the application of
the product, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind including without
limitation warranties on non- infringement of intellectual property rights and any third party.
In addition, any information given in this document is subject to customer’s compliance with its obligations stated in this
document and any applicable legal requirements, norms and standards concerning customer’s product and any use of
the product of Infineon Technologies in customer’s applications.
The data contained in this document is exclusively intended for technically trained staff. It is the responsibility of any
customer’s technical departments to evaluate the suitability of the product for the intended applications and the
completeness of the product information given in this document with respect to applications.
For further information on the product, technology, delivery terms and conditions and prices, please contact your local
sales representative or go to (www.infineon.com/hirel).
WARNING
Due to technical requirements products may contain dangerous substances. For information on the types in question,
please contact your nearest Infineon Technologies office.
13
2016-06-29
Similar pages