Click on Series name for product info on aimtec.com Series AM1L-NZ 1 Watt | DC-DC Converter FEATURES: • Single, Dual, & Dual Separated Models • SMD Package • Low ripple and noise • High efficiency up to 83% • • • • Operating temperature -40oC to + 85oC Input / Output Isolation 1000 & 3000VDC Pin compatible with multiple manufacturers RoHS compliant Models Single output Input Voltage (V) Output Voltage (V) AM1L-0303S-NZ AM1L-0305S-NZ AM1L-0505S-NZ AM1L-0509S-NZ AM1L-0512S-NZ AM1L-0515S-NZ AM1L-0524S-NZ AM1L-1205S-NZ AM1L-1209S-NZ AM1L-1212S-NZ AM1L-1215S-NZ AM1L-2405S-NZ AM1L-2412S-NZ AM1L-2424S-NZ 3.0-3.6 3.0-3.6 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 3.3 5 5 9 12 15 24 5 9 12 15 5 12 24 304 200 200 111 84 67 40 200 111 84 67 200 84 40 AM1L-0505SH30-NZ AM1L-0509SH30-NZ AM1L-0512SH30-NZ AM1L-0515SH30-NZ AM1L-1205SH30-NZ AM1L-1212SH30-NZ AM1L-1215SH30-NZ 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 5 9 12 15 5 12 15 200 111 84 67 200 84 67 Model Output Current Max | Min (mA) Isolation (VDC) Efficiency (%) 30 20 20 11 8 6 4 20 11 8 6 20 8 4 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 70 71 78 74 77 78 73 73 75 79 80 72 83 80 20 11 8 6 20 8 6 3000 3000 3000 3000 3000 3000 3000 70 75 78 80 72 79 81 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current Max | Min (mA) Isolation (VDC) Efficiency (%) AM1L-0509D-NZ AM1L-0512D-NZ AM1L-0515D-NZ AM1L-1215D-NZ AM1L-2415D-NZ 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 21.6-26.4 ±9 ±12 ±15 ±15 ±15 ±56 ±42 ±33 ±33 ±33 ±6 ±4 ±3 ±3 ±3 1000 1000 1000 1000 1000 78 79 78 77 75 AM1L-0505DH30-NZ AM1L-0509DH30-NZ AM1L-0512DH30-NZ AM1L-0515DH30-NZ AM1L-1212DH30-NZ AM1L-1215DH30-NZ 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 ±5 ±9 ±12 ±15 ±12 ±15 ±100 ±56 ±42 ±33 ±42 ±33 ±10 ±6 ±4 ±3 ±4 ±3 3000 3000 3000 3000 3000 3000 72 75 78 79 78 79 www.aimtec.com F 051e R8.O Tel: +1 514 620 2722 1 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter Models Dual Separated Output Model Input Voltage (V) Output Voltage (V) Output Current Max | Min (mA) AM1L-050505D-NZ 4.5-5.5 5/5 100/100 *AM1L-051212D-NZ 4.5-5.5 12/12 42/42 *AM1L-051515D-NZ 4.5-5.5 15/15 33/33 AM1L-121212D-NZ 10.8-13.2 12/12 42/42 *Not recommended for new design NOTE 1: Add suffix “TR” to a part number when ordering in tape and reel package 10/10 4/4 3/3 4/4 Isolation (VDC) Efficiency (%) 1000 1000 1000 1000 70 79 80 78 NOTE 2: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Input Specifications Parameters Voltage range Nominal Typical 3 5 12 24 Maximum Units 3.0-3.6 4.5-5.5 10.8-13.2 21.6-26.4 VDC Filter Capacitor Isolation Specifications Parameters Tested I/O voltage Tested V1 output/ V2 output Capacitance V input/V output Capacitance V1 output/V2 output Resistance Conditions Typical 60 sec 60 sec 500Vdc 500Vdc 500Vdc Rated Units 1000 & 3000 VDC VDC pF pF MOhm 1000 60 60 > 1000 Output Specifications Parameters Conditions Voltage accuracy Voltage balance Short Circuit protection Line voltage regulation (Single) Line voltage regulation (Dual) Line voltage regulation (Dual Separated) Load voltage regulation (Single) Load voltage regulation (Dual) Load voltage regulation (Dual Separated) Temperature coefficient Ripple & Noise See the tolerance graph Dual Output Typical Maximum ±5 ±2 Momentary (1sec) ±1.2 ±1.2 ±1.2 10 10 12.8 ±0.03 75 For 1.0% of Vin For 1.0% of Vin For 1.0% of Vin Load 10 – 100% Load 10 – 100% Load 10 – 100% At 20MHz Bandwidth Units % % 100 % % % % % % o %/ C mV p-p If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the load to ensure the actual load current meets the minimum load current requirement. General Specifications Parameters Switching frequency Max Case temperature Operating temperature Storage temperature Cooling www.aimtec.com F 051e R8.O Conditions Typical 100% load 100 Maximum +95 Without derating -40 to +85 -55 to +125 Free air convection Tel: +1 514 620 2722 2 of 7 Units KHz o C o C o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units % Plastic UL94-VO 1.5 g Dual Separated 2.1 Single 1000VDC 0.50 x 0.44 x 0.25 inch 12.70 x 11.20 x 6.25 mm Dual 1000VDC 0.60 x 0.44 x 0.25 inch 15.24 x 11.20 x 6.25 mm Dual Separated 1000VDC 0.70 x 0.70 x 0.24 inch 17.78 x 17.78 x 6.00 mm Single and Dual 3000VDC 0.6 x 0.44 x 0.26 inch 15.24 x 11.20 x 6.50 mm o >980 000 hrs single, 1 000 000hrs dual (MIL-HDBK -217F, Ground Benign, t=+25 C) Humidity Case material 95 Weight Dimensions (L x W x H) MTBF Safety Specifications Parameters Agency approvals Standards cULus (without 24V models and dual separate models) CE (for 5 and 12 Vin single models) IEC/UL 60950-1 Pin Out Specifications 1000VDC 3000VDC Pin Single Pin Single Dual 1 2 3 4 5 6 7 8 - V Input + V Input N. C. - V Output .+V Output N.C. N.C. N.C. 1 2 3 4 5 6 7 8 9 10 11 12 - V Input + V Input N.C. Omitted -V Output N.C. N.C. +V Output Omitted N.C. N.C. N.C. - V Input + V Input N.C. Omitted Common -V Output N.C. +V Output Omitted N.C. N.C. N.C. Pin 1 2 3 4 5 6 7 8 9 10 Dual - V Input + V Input N. C. Common .-V Output N.C. +V Output N.C. N.C. N.C. Pin Dual Separated 1 2 3 5 6 7 8 9 10 12 13 14 - V Input + V Input N.C. - V1 Output .+V1 Output N.C N.C .+V2 Output - V2 Output N.C N.C N.C N.C: Not Connected www.aimtec.com F 051e R8.O Tel: +1 514 620 2722 3 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter Dimensions Single 1000VDC Dimensions Dual 1000VDC Front View Front View 6.70 (0.26) Side View 4.13 (0.16) 0.30 (0.01) 6.00 (0.24) 0.30 (0.01) 1.85 (0.07) Top View 7.00 (0.28) 15.24 (0.60) A 12.70 (0.50) A 6.25 (0.25) 0.25 (0.01) 7.00 (0.28) 1.85 (0.07) Top View 4.13 (0.16) A 6.00 6.25 (0.24) (0.25) 0.25 (0.01) 6.70 (0.26) Side View A 0.50 (0.02) 11.20 7.50 (0.44) (0.30) 11.20 7.50 (0.44) (0.30) 0.50 (0.02) 5.00º angle 1 1 5.00º angle 1.50 (0.06) 0.60 (0.024) 2.54 (0.10) 0.60 (0.024) 2.54 (0.10) All dimensions are in mm (inch) All Pins are on a 2.54mm (0.10inch) pitch with tolerance of ±0.25mm (0.01inch) All dimensions are in mm (inch) All Pins are on a 2.54mm (0.10inch) pitch with tolerance of ±0.25mm (0.01inch) Dimensions Single and Dual 3000VDC Dimensions Dual Separated 1000VDC Front View Side View Side View 6.76 (0.27) 4.25 (0.17) 6.25 (0.25) 0.30 (0.01) 15.24 (0.60) A 5.75 6.00 (0.23) (0.24) A 0.25 (0.01) 1.35 (0.05) Front View 2.75 (0.11) 6.50 (0.26) Top View 1.50 (0.06) 0.25 (0.01) 0.25 (0.01) 12.70 (0.50) Top View 7.15 (0.28) 17.78 (0.70) A A 11.20 7.50 (0.44) (0.30) 0.50 (0.02) 0.50 (0.02) 17.78 12.70 (0.70) (0.50) 5.00º angle 1 1 5.00º angle 2.54 (0.10) 0.60 (0.024) All dimensions are in mm (inch) All Pins are on a 2.54mm (0.10inch) pitch with tolerance of ±0.25mm (0.01inch) www.aimtec.com F 051e R8.O 2.54 (0.10) 1.35 (0.05) 1.20 (0.05) 1.80 (0.07) 1.30 (0.05) All dimensions are in mm (inch) All Pins are on a 2.54mm (0.10inch) pitch with tolerance of ±0.25mm (0.01inch) Tel: +1 514 620 2722 4 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter Recommended Filter Circuit Tolerance Graph L Single Output L +Vout + Vin + Cin + DC DC Cout - Vin - Vin L Dual Output L +Vout + Vin + Cin + DC Cout Common DC + L Cout - Vin -Vout L Dual Separated Output L +V1output + Vin + Cout -V1 output Cin + DC DC L +V2 output + Cout -V2 output - Vin If it is required to decrease the input/output ripple, an “LC” filter network can be installed on the input and output of the converter (see above). It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC converter switching frequency to avoid mutual interference. The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and ensure safe and reliable operation. It’s not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5 watt. External Capacitor Tables Input Capacitor (Cin) Vin (VDC) Cin (uF) 5 12 4.7 2.2 www.aimtec.com F 051e R8.O Output Capacitor (Cout) Single Vout (VDC) 5 9 12 15 Cout (uF) Dual Vout (Vdc) Cout (uF) Dual SeperatedV out (Vdc) Cout (uF) 10 4.7 2.2 1 ±5 ±9 ±12 ±15 4.7 2.2 1 0.47 5/5 9/9 12/12 15/15 4.7 2.2 1 0.47 Tel: +1 514 620 2722 5 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter Typical Efficiency vs. Loading Eff % AM1L-0303S-NZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Loading % Eff % AM1L-0505S-NZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Loading % www.aimtec.com F 051e R8.O Tel: +1 514 620 2722 6 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1L-NZ 1 Watt | DC-DC Converter Eff % AM1L-1212S-NZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Loading % Eff % AM1L-2424S-NZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Loading % NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.O Tel: +1 514 620 2722 7 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only