EC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C20 with Filter, Line Switch 2-pole C20 Approvals and Compliances 70° C Description - Panel Mount : Screw-on mounting from front side - 3 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired Line switch non-illuminated With EMC-shield Ideal for application with high transient loads Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Line switch, illuminated - Line switch with other rocker marking - Variant with notch for V-Lock mating Cordsets References Alternative: version without line filter EC11 Alternative: Standard version Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz 12 - 20 A @ Ta 40 °C / 125/250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C appliance inlet/-outlet 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 MTBF Line Switch Line Filter C20 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'700'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals EMC Products 1 EC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: EC12 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001522 UL Approvals UL UL File Number: E72928 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Medical Equipment 2 EMC Products EC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] 31.1 37 2.8 32.9 3.6 0.8 32.2 R 48 ±0.10 R 12.55 57 ±0.10 47.05 23.85 46.2 12.2 10.9 4. 7 R6 5.5 .5 R 4.55 ±0.05 68 57 23.85 3. 55 ±0 .0 5 05 3. 8 R 2. S 3.3 6.4 9.5 33.9 ±0.10 59.5 5.3 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 12 Standard Version 2 x 0.8 100 2.2 1 16 Standard Version 2 x 0.6 100 2.2 1 20 Standard Version 2 x 0.3 100 2.2 1 12 Medical Version (M5) 2 x 0.8 100 - 1 16 Medical Version (M5) 2 x 0.6 100 - 1 20 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Standard version Medical version (M5) L L’ L1 1) PE Cx Cy R L2 Cy N 1) Line 2) Load L 2) PE’ N’ L’ L1 1) PE Cx 2) PE’ R L2 N’ N 1) Line 2) Load Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 12 A 16 A 20 A EMC Products 3 EC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Medical version (M5) 12 A 16 A 20 A All Variants Rated Current [A] Filter-Type Internally wired Line Switch 12 Standard Version l 2-pole 12 Standard Version l 2-pole V-Lock Order Number EC12.3101.001 l █ EC12.3101.001.21 16 Standard Version l 2-pole EC12.2101.001 █ 20 Standard Version l 2-pole EC12.1101.001 █ 12 Standard Version 2-pole EC12.3101.002 16 Standard Version 2-pole EC12.2101.002 20 Standard Version 2-pole EC12.1101.002 12 Medical Version (M5) l 2-pole EC12.3201.001 16 Medical Version (M5) l 2-pole 16 Medical Version (M5) l 2-pole 20 Medical Version (M5) l 2-pole EC12.1201.001 12 Medical Version (M5) 2-pole EC12.3201.002 16 Medical Version (M5) 2-pole EC12.2201.002 20 Medical Version (M5) 2-pole EC12.1201.002 EC12.2201.001 l EC12.2201.001.21 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 20 Pcs Accessories Description Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0108 4 EMC Products EC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Cord retaining kits Cord retaining strain relief Flat head, H 4700.0008 Mating Outlets/Connectors Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 0104U Connector further types to EC12 Mating Outlets/Connectors shuttered Power Cord Overview complete Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS 02.12.2017 Power Cord further types to EC12 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 5