ZCOMM CLV0798A-LF C3 Voltage-controlled oscillator surface mount module Datasheet

CLV0798A-LF
PHASE NOISE (1 Hz BW, typical)
14118 Stowe Drive, Suite B | Poway, CA 92064
TEL: (858) 621-2700 | FAX: (858) 486-1927
URL: www.zcomm.com
EMAIL: [email protected]
Applications
• Digital Radios
• Basestation
•
-70
-80
-90
£(f) (dBc/Hz)
Voltage-Controlled Oscillator
Surface Mount Module
Rev C3
-100
-110
-120
-130
-140
Application Notes
• AN-101: Mounting and Grounding
-150
1 E+3
10 E+3
100 E+3
• AN-102: Output Loading
• AN-107: Manual Soldering
OFFSET (Hz)
Performance Specifications
Min
Oscillation Frequency Range
730
Typ
Max
Units
920
MHz
Phase Noise @ 10 kHz offset (1 Hz BW)
-109
dBc/Hz
Harmonic Suppression (2nd)
-15
dBc
Tuning Voltage
1
15
MHz/V
28
Tuning Sensitivity (avg.)
6.5
dBm
100
pF
Pushing
2
MHz/V
Pulling (14 dB Return Loss, Any Phase)
1
MHz
80
°C
Max
Units
Power Output
-2
Load Impedance
2.25
Vdc
50
Input Capacitance
Operating Temperature Range
-40
Package Style
Power Supply Requirements
MINI-16-L
Min
Typ
Supply Voltage (Vcc, nom.)
5
Supply Current (Icc)
16
Vdc
22
mA
Additional Notes
LFSuffix = RoHS Compliant. All specifications are subject to change without notice.
© Z-Communications, Inc. All Rights Reserved.
Page 1 of 2
FRM-S-002 B
CLV0798A-LF
Voltage-Controlled Oscillator
Surface Mount Module
Rev C3
Tuning Curve, typ.
FREQUENCY (MHz)
1100
1000
900
80 °C
25 °C
800
-40 °C
700
600
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TUNING VOLTAGE (Vdc)
POWER OUTPUT (dBm)
Power Curve, typ.
Footprint
RECOMMENDED FOOTPRINT
9
SEVERAL HOLES OF O 0.015 ON
GND. PLANE ARE RECOMMENDED
FOR GOOD GROUNDING.
7
5
3
1
0.030 MIN. CUTBACK
FROM LIVE PADS
-1
-3
-5
636 681
715 745
773 800
826 852
878 904
932 959
989 1019 1049 1077
FREQUENCY (MHz)
80 °C
25 °C
-40 °C
Physical Dimensions
PIN CONFIGURATION
Z-COMM
XXXXXXXX-LF
W/O#
D/C
P1
P2
P3
REST
Vt
RF OUT
Vcc
GROUND
PACKAGE
H
MINI-16
0.220
MINI-16-LOW
0.160
MINI-16-L
0.130
MINI-16-UL
0.100
MINI-16-EL
0.085
NOTE: ALL DIMENSIONS ARE IN INCHES
TOL: XXX: +/- 0.010
LFSuffix = RoHS Compliant. All specifications are subject to change without notice.
© Z-Communications, Inc. All Rights Reserved.
Page 2 of 2
FRM-S-002 B