VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts KEY FEATURES Universal Input: 90-264 VAC With P.F.C. Function, PF>0.95 Remote Sense Function Remote ON/OFF Function Current Share Function Power Good Function Protections: Over Load / Over Voltage / Over Temperature / Short Circuit All by Auto-recovery High Power Density RoHS Compliant Design 3-Years Product Warranty ELECTRICAL SPECIFICATIONS Model No. Max Output Wattage (Convection) Voltage Input Output Protection Isolation Function Environment (W) AQF600-12S AQF600-24S AQF600-28S AQF600-36S AQF600-48S AQF600-54S 480W 600W 600W 600W 600W 600W 90-264 VAC or 120-370 VDC Frequency (Hz) 47-63 Hz Current (Full load) < 0.8 A max. (115 VAC) / < 4.0 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 3.5 mA max.(240VAC 63Hz) Power Factor PF>0.98 (115 VAC) / PF>0.93 (230 VAC) at Full Load Voltage (V.DC.) 12V Trim ±5% Voltage Accuracy ±2% Current (Convection) (A) max 40 Line Regulation (LL-HL) (typ.) ±1% Load Regulation (5-100%) (typ.) ±1% Minimum Load 5% Maximum Capacitive Load 70,000 uF Ripple & Noise (max.) < 1% Efficiency (typ.) 90% Hold-up Time 12 ms min. Switching Frequency 100 kHz Over Power Protection Auto recovery Over Voltage Protection Auto recovery Over Temperature Auto recovery Short Circuit Protection Auto-recovery Input-Output (V.AC) 3000V Input-FG (V.AC) 1500V Output-FG .(V.AC) 24V 28V 36V 48V 54V 25 21.4 16.6 12.5 11.1 60,000 uF 48,000 uF 30,000 uF 20,000 uF 10,000 uF 91% 92% 92% 93% 93% 500V 5V Stand by (18CFM FAN) 5VSB: [email protected] ; Tolerance ±10% , Ripple & Noise: 100m Vp-p (max.) DC OK Signal Turn ON: 4~6V ; Turn OFF: 0~1V Remote Control +RC / -RC: Power ON=open ; Power OFF=short FAN Control 12VDC / 0.5A max. Operating Temperature -25°C…+70°C (with derating) Storage Temperature -25°C…+85°C Temperature Coefficient ±0.03%/°C ( 0~50°C ) Humidity 95% RH MTBF >120,000 h @ 25°C (MIL-HDBK-217F) Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. 1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts ELECTRICAL SPECIFICATIONS Model No. Physical Safety EMC AQF600-12S AQF600-24S Dimension (L x W x H) 9.0 x 4.13 x 1.72 Inches Weight 1200 g Cooling Convection Cooled Agency Approvals CE, UL60950 AQF600-28S AQF600-36S AQF600-48S AQF600-54S (228.5 x 105.0 x 44.0 mm ) Tolerance ±0.5 mm (Pending) EMI (Conducted & Radiated Emission) EN 55022 class B, Radiated Class A (Pending) EMS (Noise Immunity) EN 55024 (Pending) 1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. BLOCK DIAGRAM DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts MECHANICAL DIMENSION AC Input Terminal Pin PIN# SINGLE 1 AC IN DC Output Terminal Pin PIN# SINGLE 2~4 +DC OUT 5~7 -DC OUT Connector Pin (CN4) PIN# SINGLE C1 +S C2 -S C3 +RC C4 -RC C5 +PG C6 GND C7 +5V SB C8 -5V SB C9 N.C C10 CS ASSEMBLY INSTRUCTIONS *U Case T=2.0mm Customer screws into the length of the case no higher than 0.5mm (Namely screw length for load plate thickness plus 2.5mm http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts FUNCTION DESCRIPITON of CN4 : Pin No. Function C1 +S C2 -S C3 +RC C4 -RC C5 DC-OK Description Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. (max.) Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. (max.) Turns the output on and off by electrical or dry contact between pin C4 (-RC), Short: Power OFF, Open: Power ON. Remote control ground. DC-OK Signal is a DC output, referenced to pinC6(DC-OK GND). C6 GND C7 +5V SB Stand by voltage output ground 4.5~5.5V, referenced to pin C8(-5V SB). The maximum load current is 0.6A. This pin connects to the negative terminal(-V). Return for DC-OK signal output. C8 -5V SB Stand by voltage output ground. C9 N.C No Pin C10 CS Current Share Function Pin FUNCTION MANUAL : 1. Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. (max.) 2. DC-OK Signal Between DC-OK(pinC5) and GND(pinC6) Output Status 4~6V 0~1V ON OFF 3. Remote Control It can be turned ON/OFF by using the "Remote Control" function. Between RC+(pinC3) and RC-(pinC4) Output Status SW ON (Short) SW OFF (Open) OFF ON http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4-