Littelfuse HQ6025NH5TP 25 amp high temperature alternistor triac Datasheet

Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
HQ6025xH5 Series
RoHS
Description
25Amp bi-directional Alternistor Triac is designed for AC
switching and phase control applications requiring a higher
temperature environment.
Alternistor type devices only operate in quadrants I, II, &
and are used in circuits requiring high dv/dt capability.
Features & Benefits
• RoHS compliant
• Surge capability up
to 300 A
Applications
Agency File Number
Typically used in high-temperature environments where
available heat-sinking is minimal such as heating and white
goods applications.
L and K Packages: E71639
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
Main Features
Symbol
• Voltage capability up
to 600 V
• Glass – passivated
junctions
Agency Approval
Agency
• 150°C maximum junction
temperature
Value
Unit
IT(RMS)
25
A
VDRM /VRRM
600
V
IGT
50
mA
Additional Information
Datasheet
Resources
Samples
Schematic Symbol
MT2
MT1
G
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Absolute Maximum Ratings
Symbol
Parameter
RMS on-state current
IT(RMS)
ITSM
Test Conditions
HQ6025LH5
TC = 95°C
HQ6025RH5
HQ6025NH5
HQ6025KH5
TC = 102°C
Peak non-repetitive surge current
I 2t
Value
Unit
25
A
full cycle; f = 50Hz;
TJ (initial) = 25°C
250
full cycle; f = 60Hz;
TJ (initial) = 25°C
300
A
I2t Value for fusing
tp = 8.3ms
373
A2s
di/dt
Critical rate-of-rise of on-state current
f = 60Hz; TJ =150°C
100
A/μs
IGTM
Peak gate current
TJ = 150°C
2
A
PG(AV)
Average gate power dissipation
TJ = 150°C
0.5
W
Storage temperature range
-40 to 150
°C
Operating junction temperature range
-40 to 150
°C
Tstg
TJ
Electrical Characteristics (TJ = 25°C, unless otherwise specified)
Symbol
Test Conditions
Quadrant
Value
Unit
IGT
VD = 12V RL = 60 Ω
I – II – III
MAX.
50
mA
VGT
VD = 12V RL = 60 Ω
I – II – III
MAX.
1.3
V
VGD
VD = VDRM RL = 3.3 kΩ TJ = 150°C
I – II – III
IH
IT = 400mA (initial)
MIN.
0.2
V
MAX..
80
mA
dv/dt
VD = VDRM; gate open; TJ = 150°C
MIN
350
V/μs
(dv/dt)c
(di/dt)c = 13.3 A/ms; TJ = 150°C
MIN
20
V/μs
tgt
IG = 2 x IGT PW = 15µs IT = 35.4A
TYP.
3
μs
Static Characteristics
Symbol
Test Conditions
VTM
IT = 35.4A; tp = 380 μs
IDRM / IRRM
VDRM / VRRM
MAX.
TJ = 25°C
TJ = 150°C
Value
Unit
1.4
V
5
MAX.
μA
6000
Thermal Resistances
Symbol
Rθ(J-C)
Rθ(J-A)
Parameter
Junction to case (AC)
Junction to ambient
Note: xx = voltage
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Value
HQ6025LH5
2.0
HQ6025RH5
HQ6025NH5
0.86
HQ6025KH5
1.35
HQ6025LH5
50
HQ6025RH5
45
Unit
°C/W
°C/W
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Figure 1: Normalized DC Gate Trigger Current
vs. Junction Temperature
Figure 2: N
ormalized DC Gate Trigger Voltage
vs. Junction Temperature
2.0
2.0
Ratio of VGT / VGT(TJ = 25°C)
Ratio of IGT / IGT(TJ = 25°C)
2.5
1.5
1.0
0.5
0.0
1.5
1.0
0.5
0.0
-40
-15
10
35
60
85
110
135
-40
150
-15
10
Junction Temperature (TJ) -- (°C)
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
Instantaneous On-state Current (iT) – Amps
Ratio of IH / IH(TJ = 25°C)
1.5
1.0
0.5
0.0
-15
10
35
60
85
110
135
150
35
30
25
20
15
10
5
0
20
25
150
80
70
60
50
40
30
20
10
0
0.7
Maximum Allowable Case Temperature (TC) - °C
Average On-State Power Dissipation
[PD(AV)] -- Watts
40
15
135
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
Figure 6: M
aximum Allowable Case Temperature
vs. RMS On-State Current
45
10
110
Instantaneous On-state Voltage (vT) – Volts
Figure 5: Power Dissipation (Typical) vs. RMS
On-State Current
5
85
90
Junction Temperature (TJ) -- (°C)
0
60
Figure 4: O
n-State Current vs. On-State
Voltage (Typical)
2.0
-40
35
Junction Temperature (TJ) -- (°C)
30
RMS On-State Current [IT(RMS)] -- Amps
35
40
160
HQ6025RH5
HQ6025NH5
HQ6025KH5
140
120
HQ6025LH5
100
80
60
40
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
20
0
0
5
10
15
20
25
30
RMS On-State Current [IT(RMS)] - Amps
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Figure 7: Maximum Allowable Case Temperature vs. Average On-State Current
Maximum Allowable Ambient Temperature
(TA) - °C
160
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180°
FREE AIR RATING
140
120
100
80
60
40
20
0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
RMS On-State Current [IT(RMS)] -- Amps
Figure 8: Surge Peak On-State Current vs. Number of Cycles
Peak Surge (Non-repetitive)
On-state Current (ITSM) – Amps
1000
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated Value at
Specified Case Temperature
Notes:
1. G
ate control may be lost during and immediately
following surge current interval.
2. O
verload may not be repeated until junction
temperature has returned to steady-state
rated value.
100
10
1
10
100
Surge Current Duration -- Full Cycles
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
1000
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Soldering Parameters
Pb – Free assembly
Pre Heat
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
200°C
- Time (min to max) (ts)
60 – 180 secs
Average ramp up rate (Liquidus Temp)
(TL) to peak
5°C/second max
TS(max) to TL - Ramp-up Rate
5°C/second max
Reflow
- Temperature (TL) (Liquidus)
217°C
- Temperature (tL)
60 – 150 seconds
Peak Temperature (TP)
260+0/-5 °C
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
Time 25°C to peak Temperature (TP)
8 minutes Max.
Do not exceed
280°C
Physical Specifications
Terminal Material
Copper Alloy
Terminal Finish
100% Matte Tin Plated
tP
TP
Temperature
Reflow Condition
Ramp-up
TL
tL
TS(max)
Preheat
TS(min)
25
tS
time to peak temperature
UL recognized epoxy meeting flammability
classification 94V-0
Test
High Temperature
Voltage Blocking
Biased Temp &
Humidity
High Temp. Storage
Design Considerations
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
Time
Environmental Specifications
Temperature Cycling
Body Material
Ramp-do
Ramp-down
Specifications and Conditions
MIL-STD-750: Method 1040, Condition A
Rated VRRM, 150°C, 1008 hours
MIL-STD-750: Method 1051
-40°C to 150°C, 15-minute dwell,
100 cycles
EIA/JEDEC: JESD22-A101
320VDC, 85°C, 85%RH, 1008 hours
MIL-STD-750: Method 1031
150°C, 1008 hours
Low-Temp Storage
-40°C, 1008 hours
Resistance to
Solder Heat
MIL-STD-750: Method 2031
260°C, 10 seconds
Solderability
ANSI/J-STD-002, Category 3, Test A
Lead Bend
MIL-STD-750: Method 2036, Condition E
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Dimensions — TO-220AB (R-Package) — Non-Isolated Mounting Tab Common with Center Lead
TC MEASURING POINT
O
A
ØE
AREA (REF.) 0.17 IN2
8.13
.320
P
MT2
Dimension
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
B
C
13.36
.526
D
7.01
.276
NOTCH IN
GATE LEAD
TO ID.
NON-ISOLATED
TAB
F
R
G
L
H
N
K
J
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm.)
M
MT1 MT2 GATE
Inches
Min
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
Millimeters
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Min
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
2.16
0.46
4.52
1.14
0.97
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Min
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
2.16
0.46
4.52
1.14
0.97
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
2.41
0.61
4.78
1.52
1.22
Dimensions — TO- 220AB (L Package) — Isolated Mounting Tab
TC MEASURING POINT
O
A
ØE
P
AREA (REF.) 0.17 IN2
8.13
.320
B
C
13.36
.526
D
7.01
.276
F
R
G
L
H
K
N
J
M
MT1 MT2 GATE
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm.)
Dimension
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
Inches
Min
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
Millimeters
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
2.41
0.61
4.78
1.52
1.22
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Dimensions — TO- 218AC (K Package) — Isolated Mounting Tab
Dimension
TC Measurement Point
U (diameter)
B
C
M Package
MT2 / Anode
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
U
W
D
A
F
E
W
Gate
J
P
MT1
MT2
H
M
Q
R
G
N
Note: Maximum torque
to be applied to mounting
tab is 8 in-lbs. (0.904 Nm).
K
L
Inches
Min
0.810
0.610
0.178
0.055
0.487
0.635
0.022
0.075
0.575
0.211
0.422
0.058
0.045
0.095
0.008
0.008
0.159
0.085
Millimeters
Max
0.835
0.630
0.188
0.070
0.497
0.655
0.029
0.095
0.625
0.219
0.437
0.068
0.055
0.115
0.016
0.016
0.163
0.095
Min
20.57
15.49
4.52
1.40
12.37
16.13
0.56
1.91
14.61
5.36
10.72
1.47
1.14
2.41
0.20
0.20
4.04
2.17
Max
21.21
16.00
4.78
1.78
12.62
16.64
0.74
2.41
15.88
5.56
11.10
1.73
1.40
2.92
0.41
0.41
4.14
2.42
Dimensions — TO-263AB (N-Package) — D2 -PAK Surface Mount
TC MEASURING POINT
B
AREA: 0.11 IN2
C
V
Dimension
E
MT2
7. 01
.276
A
8.41
.331
S
W
U
G
J
K
GATE
MT1
H
D
8.13
.320
F
2.16
.085
11.68
.460
7. 01
.276
7. 01
.276
16.89
.665
8.89
.350
1.40
.055
3.81
.150
Inches
Millimeters
A
Min
0.360
Max
0.370
Min
9.14
Max
9.40
B
0.380
0.420
9.65
10.67
C
0.178
0.188
4.52
4.78
D
0.025
0.035
0.64
0.89
E
0.045
0.060
1.14
1.52
F
0.060
0.075
1.52
1.91
G
0.095
0.105
2.41
2.67
H
0.092
0.102
2.34
2.59
J
0.018
0.024
0.46
0.61
K
0.090
0.110
2.29
2.79
S
0.590
0.625
14.99
15.88
V
0.035
0.045
0.89
1.14
U
0.002
0.010
0.05
0.25
W
0.040
0.070
1.02
1.78
2.03
.080
6.60
.260
Product Selector
Part Number
Voltage
400V
600V
800V
1000V
Gate Sensitivity
Package
TO-220R
HQ6025RH5
X
50 mA
HQ6025NH5
X
50 mA
TO-263
HQ6025LH5
X
50 mA
TO-220L
HQ6025KH5
X
50 mA
TO-218K
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Teccor® brand Thyristors
25 Amp High Temperature Alternistor Triacs
Packing Options
Marking
Weight
Packing Mode
Base Quantity
HQ6025RH5TP
Part Number
HQ6025RH5
2.2g
Tube
500 (50 per tube)
HQ6025NH5TP
HQ6025NH5
1.6g
Tube
500 (50 per tube)
HQ6025NH5RP
HQ6025NH5
1.6g
Embossed Carrier
500
HQ6025LH5TP
HQ6025LH5
2.2g
Tube
500 (50 per tube)
HQ6025KH5TP
HQ6025KH5
4.4g
Tube
250 (25 per tube)
TO-263 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.63
(16.0)
0.157
(4.0)
Gate
0.059
DI A
(1.5)
MT1
0.945
(24.0)
0.827 *
(21.0)
* Co ver tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
1.01
(25.7)
Direction of Feed
Part Numbering System
Part Marking System
TO-220 AB - (L and R Package)
TO-263 AB - (N Package)
HQ 60 25 L H5 81
DEVICE TYPE
HQ: Triac
VOLTAGE RATING
60: 600V
TO-218AC - (K Package)
LEAD FORM DIMENSIONS
xx: Lead Form Option
HQ6025KH5
SENSITIVITY & TYPE
H5: 50mA
HQ6025RH5
YM
YMLXX
®
CURRENT RATING
25: 25A
PACKAGE TYPE
L: TO-220 AB (Isolated)
K: TO-218 AC (Isolated)
R: TO-220AB (Non-isolated)
N: TO-263 (D2 Pak)
Date Code Marking
Y:Year Code
M: Month Code
XXX: Lot Trace Code
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/02/16
Date Code Marking
Y:Year Code
M: Month Code
L: Location Code
XX: Lot Serial Code
Similar pages