Omron MKS2TI-11 General purpose power relay Datasheet

General Purpose Power Relays
MKS-X
MK-S-series Relays with AC and DC Load
switching Models
• Models for DC Loads can switch 220 VDC, 10 A (resistive).
• Models for AC Loads can switch 250 VAC, 15 A (resistive).
• Lineup includes models with 1FormA and 1FormA+1FormB
contact arrangements.
• Models available with operation indicators and built-in test buttons.
• Standards: UL/CSA, IEC (TÜV certification)
• RoHS compliant.
Ordering Information
■ List of Models
Models for DC Loads
Contact form
Type
Models for AC Loads
SPST-NO
SPST-NO/SPST-NC
SPST-NO
Model
Model
Model
Standard
MKS1XT-10
Built-in Operation Indicators
Test Button
SPST-NO/SPST-NC
Model
MKS2XT-11
MKS1T-10
MKS2T-11
MKS1XTN-10
MKS2XTN-11
MKS1TN-10
MKS2TN-11
MKS1XTI-10
MKS2XTI-11
MKS1TI-10
MKS2TI-11
MKS2XTIN-11
MKS1TIN-10
MKS2TIN-11
Test Button and Built-in Operation Indicators MKS1XTIN-10
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.
Example: MKS2XTIN-11 AC240
Rated voltage
2. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.
■ Accessory (Order Separately)
Connecting Socket and Hold-down Clips
Classifications
Back-connecting Socket
PCB Mount
Front-connecting Socket
DIN Track or Panel Mount
Built-in diode
Socket
No
P7M-06P
No
P7MF-06
Yes
P7MF-06-D
Hold-down Clip
PYC-A2
Note: 1. The P7M-06P, P7MF-06, and P7MF-06-D can be used with models for DC loads with an SPST-NO or SPST-NO/SPST-NC contact form
or with models for AC loads with an SPST-NO or SPST-NO/SPST-NC contact form.
2. The P7MF-06-D has a built-in diode and can thus be used only with Relays with DC operating coils. Do not use it with a Relay with an
AC operating coil.
3. Refer to Gang Mounting in the Safety Precautions section for the conditions required to gang mounti multiple relays side-by-side.
4. Use the Clips to securely mount the Relay and prevent it from falling due to vibration or shock.
General Purpose Power Relays
MKS-X
1
Specifications
■ Contact Ratings
Models for DC Loads
Contact form
Model
Load
Item
Contact configuration
SPST-NO
SPST-NO/SPST-NC
MKS1XT(I)(N)-10
MKS2XT(I)(N)-11
Inductive load
Resistive load
L/R = 7 ms
NO
DC13 class
Resistive load
Double-break
Double-break
---
Single-break
NC
Contact material
AgSnIn
Rated load
NO
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
(reference value)
10 A, 220 VDC
Inductive load
L/R = 7 ms
AgSnIn
5 A, 220 VDC
0.4 A, 220 VDC
5 A, 220 VDC
2 A, 220 VDC
3 A, 220 VDC
NC
---
NO
10 A
5A
NC
---
2A
220 VDC
NO
220 VDC
---
NO
10 A
5A
NC
---
2A
2,200 W
---
NC
---
---
0.2 A, 220 VDC
0.3 A, 220 VDC 0.1 A, 220 VDC
NC
NO
DC13 class
1,100 W
---
---
440 W
---
---
Note: 1. If the L/R of an inductive load exceeds 7 ms with a Model for a DC Load, the arc interruption time must be less than approximately 50 ms
to use the Relay. Design the circuit so that the arc interruption time is 50 ms or less.
2. These values apply to a switching frequency of 30 times per minute.
Models for AC Loads
Contact form
SPST-NO
SPST-NO/SPST-NC
MKS1T(I)(N)-10
MKS2T(I)(N)-11
Resistive load
Resistive load
NO
Double-break
Double-break
NC
---
Single-break
Model
Load
Item
Contact configuration
Contact material
AgSnIn
AgSnIn
15 A, 250 VAC
15 A, 250 VAC
Rated load
NO
NC
---
5 A, 250 VAC
Rated carry current
NO
15 A
15 A
NC
---
5A
Max. switching voltage
NO
250 VAC
250 VAC
NC
---
Max. switching current
NO
15 A
NC
---
5A
NO
3,750 VA
3,750 VA
NC
---
1,250 VA
Max. switching capacity
(reference value)
15 A
Note: These values apply to a switching frequency of 20 times per minute.
2
General Purpose Power Relays
MKS-X
■ Coil Ratings
Item Rated current (mA)
Rated voltage (V)
AC
DC
50 Hz
60 Hz
Coil resistance
(Ω)
24
110
96.3
48.4
100
26.6
23.1
760
110
24.2
21.0
932
120
22.2
19.3
1,130
200
13.3
11.6
3,160
220
12.1
10.5
3,550
230
11.5
10.0
4,250
240
11.0
9.6
12
126
95
24
63.2
380
48
32.0
1,500
110
13.6
8,060
220
6.8
32,200
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage (V)
80% max. of rated 30% min. of rated 110% of rated
voltage
voltage at 60 Hz voltage
Power consumption
(VA, W)
Approx. 2.3 VA
at 60 Hz
25% min. of rated
voltage at 50 Hz
Approx. 2.7 VA
at 50 Hz
15% min. of rated
voltage
Approx. 1.5 W
4,480
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The Maximum Voltage is the highest voltage that can be applied to the coil temporarily, not continuously.
4. The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils).
■ Characteristics
Contact resistance (See note 2)
100 mΩ max.
Operate time (See note 3)
AC: 20 ms max.
DC: 30 ms max.
Release time (See note 3)
20 ms max.
Max. operating frequency Mechanical
Electrical
18,000 operations/h
Models for DC loads: 1,800 times/hour
Models for AC loads: 1,200 times/hour
Insulation resistance (See note 4)
100 MΩ min.
Dielectric strength
2,500 VAC 50/60 Hz for 1 min. between coil and contacts
2,500 VAC 50/60 Hz for 1 min. between contacts of different polarity
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity
Vibration resistance
Destruction:
Malfunction:
10 to 55 Hz, 1.0-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s2 when relay is properly mounted into P7M-06P PCB socket
500m/s2 when relay is properly mounted into P7MF-06(-D) socket
100 m/s2
Malfunction
Life expectancy
Mechanical
1,000,000 operations min. (at 18,000 operations/hr)
Electrical (See note 5) 100,000 operations min. (at rated load and maximum switching frequency)
Minimum permissible load
(Reference value. See note 6)
10 mA at 24 VDC
Ambient operating temperature
−40°C to 60°C (with no icing or condensation)
Note: The range is −25°C to 60°C for models with built-in operation indicators.
Ambient operating humidity
5% to 85%
Weight
SPST-NO: Approx. 73 g, SPST-NO/SPST-NC: Approx. 82 g
Note: 1.
2.
3.
4.
The values given above are initial values.
The contact resistance was measured for 1 A at 5 VDC using the voltage drop method.
The operate time was measured with the rated voltage imposed and any contact bounce ignored at an ambient temperature of 23°C.
The insulation resistance was measured with a 500-VDC insulation resistance tester at the same places as those used for checking the
dielectric strength.
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. P level: λ60=0.1 x 10-6/operations
General Purpose Power Relays
MKS-X
3
■ Approved Standards
UL Recognized
CSA Certified
Model
Coil ratings
12 to 220 VDC
MKS1XT@-@
24 to 240 VAC
Contact ratings
10 A, 220 VDC (Resistive)
NO contacts 5 A, 220 VDC L/R (T0.632) = 7 ms
0.4 A, 220 VDC L/R (T0.95) = 300 ms
Operations
6,000
5 A, 220 VDC (Resistive)
NO contacts 3 A, 220 VDC L/R (T0.632) = 7 ms
0.2 A, 220 VDC L/R (T0.95) = 300 ms
MKS2XT@-@
2 A, 220 VDC (Resistive)
NC contacts 0.3 A, 220 VDC L/R (T0.632) = 7 ms
0.1 A, 220 VDC L/R (T0.95) = 300 ms
MKS1T@-@
NO contacts 15 A, 250 VAC (Resistive)
NO contacts 15 A, 250 VAC (Resistive)
MKS2T@-@
NC contacts 5 A, 250 VAC (Resistive)
IEC Standard/TÜV Certification: IEC61810-1 (Certification No. R50104853)
Model
Coil ratings
12, 24, 48, 110, 220 VDC
MKS1XT@-@
MKS2XT@-@
MKS1T@-@
MKS2T@-@
4
24, 100, 110, 120, 200,
220, 230, 240 VAC
Contact ratings
DC-1: 10 A, 220 VDC
NO contacts 5 A, 220 VDC L/R (T0.632) = 7 ms
DC-13: 0.4 A, 220 VDC
DC-1: 5 A, 220 VDC
NO contacts 3 A, 220 VDC L/R (T0.632) = 7 ms
DC-13: 0.2 A, 220 VDC
DC-1: 2 A, 220 VDC
NC contacts 0.3 A, 220 VDC L/R (T0.632) = 7 ms
DC-13: 0.1 A, 220 VDC
NO contacts AC-1: 15 A, 250 VAC 50/60 Hz
NO contacts AC-1: 15 A, 250 VAC 50/60 Hz
NC contacts AC-1: 5 A, 250 VAC 50/60 Hz
General Purpose Power Relays
MKS-X
Operations
100,000
Engineering Data
MKS1XT@-10
MKS2XT@-11
Switching current (A)
Switching current (A)
Maximum Switching Power
100
DC resistive load
10
5
DC inductive load
L/R = 7 ms
1
100
5
3
2
DC resistive load
L/R = 7 ms
NC
1
0.4
DC resistive load
L/R = 7 ms
NO
DC resistive load
NO
10
DC resistive load
NC
0.3
0.2
0.1
0.1
DC inductive load
DC13 class
DC resistive load
DC13 class
NO
DC resistive load
DC13 class
NC
0.01
0.01
1
10
100
1
1.000
10
100
Switching voltage (V)
MKS2T@-11
Switching current (A)
MKS1T@-10
Switching current (A)
1.000
Switching voltage (V)
100
15
10
AC resistive load
100
AC resistive load
NO
15
10
5
1
1
0.1
0.1
AC resistive load
NC
0.01
0.01
1
10
100
1
1.000
10
100
Switching voltage (V)
1.000
Switching voltage (V)
MKS2XT-11
AC Specification (60 Hz)
DC Specification
Must operate/release voltage (%)
Must operate/release voltage (%)
Ambient Temperature vs. Pick-up and Drop out Voltage
100
Number of Relays: 5
MKS2XT-11
Must operate
voltage
Must release
voltage
80
60
40
100
Must operate
voltage
Must release
voltage
Number of Relays: 5
80
60
40
20
20
-40
23
60
-40
Ambient temperature (°C)
23
60
Ambient temperature (°C)
Inductive Load Switching Power (Models for DC Loads)
MKS2XT@-11
100
220 VDC
10
1
Switching current (A)
Switching current (A)
MKS1XT@-10
10
220 VDC
NO
1
0.1
NC
0.1
0.01
0 7 10
50
100
Load time constant (ms)
0 7 10
50
100
Load time constant (ms)
General Purpose Power Relays
MKS-X
5
Dimensions
(Unit: mm)
Models for DC Loads
Standard Models
MKS1XT-10
MKS2XT-11
34.5 max.
Models with Built-in Operation Indicators
MKS1XTN-10
MKS2XTN-11
34.5 max.
Models for AC Loads
0.8
Standard Models
MKS1T-10
MKS2T-11
44 max.
Models with Built-in Operation Indicators
MKS1TN-10
MKS2TN-11
7.3
3.5
Models for DC Loads
Models with Test Button
MKS1XTI-10
MKS2XTI-11
34.5 max.
Models with Test Button and Built-in
Operation Indicators
MKS1XTIN-10
34.5 max.
MKS2XTIN-11
0.8
Models for AC Loads
0.5
Models with Test Button
MKS1TI-10
MKS2TI-11
44 max.
Models with Test Button and Built-in
Operation Indicators
MKS1TIN-10
29.7
MKS2TIN-11
7.3
Terminal Arrangement and Internal Connection (Bottom View)
MKS1XT-10
MKS1XTI-10
MKS1XTN-10
MKS1XTIN-10
DC specification
MKS2XT-11
MKS2XTI-11
MKS2XTN-11
MKS2XTIN-11
AC specification
DC specification
6 (+)
4
6 (+)
4
8
8
A
B
A (+)
4
8
B (−)
MKS1T-10
MKS1TI-10
6 (+)
A
A
MKS1TN-10
MKS1TIN-10
DC specification
6 (+)
4
B
A (+)
6
4
A
6
4
DC specification
B
A (+)
6
4
8
B (−)
A
A
6
4
General Purpose Power Relays
MKS-X
B
AC specification
2
6
4
8
B
A (+)
Note: 1. Wire properly using the correct coil polarity.
2. The contact terminals on Models for DC Loads have polarity. Wire properly using the correct polarity.
6
A
2
8
B
6 (+)
MKS2TN-11
MKS2TIN-11
AC specification
8
8
4
8 (+)
B (−)
MKS2T-11
MKS2TI-11
2
4
6 (+)
8 (+)
8 (+)
B
2
2
2
4
AC specification
6
8
B (−)
A
B
Connecting Socket
Back-connecting Socket
P7M-06P
Dimensions
Terminal Arrangement/Internal Connections PCB Mounting Holes
(Bottom View)
(Bottom View)
39 max.
2
5.5
6
4
43 max.
0.9
39 max.
8
A
8.3
7.7
B
11.05 11.05
21.9
4.35
22.1
7.7
0.9
8.3
5.5
Front-connecting Socket
P7MF-06
P7MF-06-D
Terminal Arrangement/Internal Connections
(TOP View)
Dimensions
7
P7MF-06
34 max.
Mounting Holes
(TOP View)
P7MF-06-D
Two, M4 or
two 3.5-dia. hole
66±0.3
78 max.
39 max.
Six, M3 x 8
35.5
6
4
24.3
Note: 1. The internal connections diagram is for the MKS2(X)T@@-11.
2. The P7MF-06-D has polarity. Be careful to wire with the
correct polarity.
General Purpose Power Relays
31±0.2
MKS-X
7
Hold-down Clip
PYC-A2
One Set (Two Clips)
5 max.
42.8
4.5
1.2
4.5
Note: The minimum order for the
PYC-A2 is ten clips.
Socket Mounting Height
P7M-06P
64
MK-S(X)
61
P7MF-06
P7MF-06-D
MK-S(X)
74
8
General Purpose Power Relays
70
MKS-X
75
79
Safety Precautions
Be sure to read the precautions and information common to all electromechanical relays, contained in the Technical User’s Guide,
“Electromechanical Relays, Technical Information” for correct use.
Precautions for Correct Use
Operating Environment
Installation
Do not use the Relay in environments with combustible gas. Doing so
may result in explosion due to arcing.
• Models for DC loads (i.e., models with “X” in the model number)
have permanent magnets built into the insulating block. If a
permanent magnet or other magnetic body comes near the Relay,
magnetic interference will occur with the built-in permanent magnet
and the contact switching capacity will be decreased.
• Models for AC loads do not contain a permanent magnet.
• When mounting a P7MF-06(-D) Front-mounting Socket to a DIN
Track, attach PFP-M End Plates on both sides of the Socket to
prevent it from moving.
Storage
Models for DC Loads (i.e., models with “X” in the model number) are
magnetized because they have a built-in magnet to deflect and
extinguish the arc. Do not install the Relay near IC cards or other
items that may be adversely affected by magnetism.
Usage
Use the Relay mounted in the P7M-06P or P7MF-06(-D) Socket.
Gang Mounting
Test Button
Conditions for mounting multiple MKS-X relays on the same DIN rail.
• Turn OFF the power supply before operating the test button. Always
return the test button to the original position after you use it.
• Do not use the test button as a switch.
• The durability of the test button is 100 operations minimum.
Socket
Back-Connecting
Socket
Front-Connecting
Socket
Models for 10A
DC Loads
❍
❍
Models for 15A
AC Loads
❍
*
Relay
Rated current
of Relay
The circuit can be checked using either of two modes.
Test Button
DC specification: Blue
AC specification: Red
Applied current (A)
* Gang mounting of the Front-Mounting Sockets is not possible if the
contact carry current exceeds 10A.Provide space on both the right
and left sides of the Sockets.
The mounting pitch is given in the following diagram.
Normal
20
15
10
5
Mode 1
(momentary)
Mode 2
(locked)
Press the button
for operation.
(No tool is required.)
Lock the contacts by
pressing down on the
button and turning it.
0
0
10
20
30
40
50
Mounting interval (mm)
Test Button Applications
Example: Checking operation of Relays and sequence circuits.
Mounting interval
Wiring
• The contact terminals on Models for DC Loads (i.e., models with “X” in
the model number) have polarity. Wiring with incorrect polarity may
result in inability to turn OFF the Relay or loss of functionality.
• Be sure to check plarity when wiring DC coil MKS-X relays with
built-in operation indicators.
General Purpose Power Relays
MKS-X
9
MEMO
10
General Purpose Power Relays
MKS-X
Omron Electronic Components, LLC
Terms and Conditions of Sales
I. GENERAL
1. Definitions: The words used herein are defined as follows.
(a) Terms:
These terms and conditions
(b) Seller:
Omron Electronic Components LLC and its subsidiaries
(c) Buyer:
The buyer of Products, including any end user in section III through VI
(d) Products: Products and/or services of Seller
(e) Including: Including without limitation
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,
invoices, purchase orders and other documents, whether electronic or in writing, relating
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's
purchase order or other documents which are inconsistent with, or in addition to, these
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including
section III of these Terms.
II. SALES
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.
Buyer agrees to pay the price in effect at the time the purchase order is accepted by
Seller. Payments for Products received are due net 30 days unless otherwise stated in
the invoice. Buyer shall have no right to set off any amounts against the amount owing in
respect of this invoice.
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to
Buyer after deducting transportation charges, taxes and duties, and will be allowed only
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past
due amounts owing to Seller.
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum
legal rate, whichever is less, on any balance not paid within the stated terms.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer
shall make remittance to Seller at the then current exchange rate most favorable to
Seller; provided that if remittance is not made when due, Buyer will convert the amount
to U.S. dollars at the then current exchange rate most favorable to Seller available
during the period between the due date and the date remittance is actually made.
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining
any government approvals regarding the importation or sale of the Products.
7. Taxes: All taxes, duties and other governmental charges (other than general real
property and income taxes), including any interest or penalties thereon, imposed directly
or indirectly on Seller or required to be collected directly or indirectly by Seller for the
manufacture, production, sale, delivery, importation, consumption or use of the Products
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,
Seller reserves the right to stop shipments or require satisfactory security or payment in
advance. If Buyer fails to make payment or otherwise comply with these Terms or any
related agreement, Seller may (without liability and in addition to other remedies) cancel
any unshipped portion of Products sold hereunder and stop any Products in transit until
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer
indemnifies Seller fully against all costs or expenses arising in connection therewith.
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from
causes beyond its control, including earthquakes, fires, floods, strikes or other labor
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,
delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise
stated in writing by Seller), at which point title to and all risk of loss of the Products
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in
the Products until the full purchase price is paid by Buyer;
(b) Delivery and shipping dates are estimates only; and
(c) Seller will package Products as it deems proper for protection against normal
handling and extra charges apply to special conditions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products
occurring before delivery to the carrier or any claim related to pricing or other charges
must be presented in detail in writing to Seller within 30 days of receipt of shipment.
III. PRECAUTIONS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.
Buyer acknowledges that it alone has determined that the Products will meet their
requirements of the intended use in all cases. Buyer must know and observe all
prohibitions of use applicable to the Product/s.
2. Use with Attention: The followings are some examples of applications for which
particular attention must be given. This is not intended to be an exhaustive list of all
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
(b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
(d) Systems, machines, and equipment that could present a risk to life or property.
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
SELLER.
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
a programmable Product.
IV. WARRANTY AND LIMITATION
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OF THE PRODUCTS.
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
amount equal to the purchase price of the Product; provided that there shall be no
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
correctly handled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
approved in writing by Seller before shipment.
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
employees from and against all liabilities, losses, claims, costs and expenses (including
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
omissions under these Terms or in any way with respect to the Products.
V. INFORMATION; ETC.
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
without the written permission of Seller. Buyer (at its own expense) shall indemnify and
hold harmless Seller and defend or settle any action brought against Seller to the extent
that it is based on a claim that any Product made to Buyer specifications infringed
intellectual property rights of another party.
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
tooling, all engineering and tooling shall remain the exclusive property of Seller. All
information and materials supplied by Seller to Buyer relating to the Products are
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
employees and strictly prevent disclosure to any third party.
3. Performance Data: Performance data is provided as a guide in determining suitability
and does not constitute a warranty. It may represent the result of Seller's test conditions,
and the users must correlate it to actual application requirements.
4. Change In Specifications: Product specifications and descriptions may be changed at
any time based on improvements or other reasons. It is Seller’s practice to change part
numbers when published ratings or features are changed, or when significant
engineering changes are made. However, some specifications of the Product may be
changed without any notice.
5. Errors And Omissions: The information on Seller’s website or in other documentation
has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
regarding (a) export of the Products or information provided by Seller; (b) sale of
Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information.
VI. MISCELLANEOUS
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
between Buyer and Seller shall operate as a waiver of rights by Seller.
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
dispute hereunder.
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
relating to the Products, and no provision may be changed or waived unless in writing
signed by the parties.
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
not invalidate any other provision.
General Purpose Power Relays
MKS-X
11
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in
Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
3. Performance Data. Performance data given in this publication is provided as
a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. J175-E-02
12
09/09
Specifications subject to change without notice
General Purpose Power Relays
MKS-X
Printed in USA
Similar pages