STMicroelectronics MK50H25PLCC High speed link level controller Datasheet

MK50H25
HIGH SPEED
LINK LEVEL CONTROLLER
ADVANCE DATA
SECTION 1 - FEATURES
System clock rate up to 33 MHz (MK50H25 33), 25 MHz (MK50H25 - 25), or 16 MHz
(MK50H25 - 16).
Data rate up to 20 Mbps continuous
(MK50H25 - 33) or up to 51 Mbps bursted
On chip DMA control with programmable burst
length.
DMA transfer rate of up to 13.3 Mbytes/sec using optional 5 SYSCLK DMA cycle (150 nS) at
33 MHz SYSCLK.
Complete Level 2 implementation compatible
with X.25 LAPB, ISDN LAPD, X.32, and X.75
Protocols.
Handles all error recovery, sequencing, and S
and U frame control.
Pin-for-pin and architecturally compatible with
MK5025 (X.25/LAPD), MK5027 (CCS#7) and
MK5029(SDLC).
Buffer Management includes:
- Initialization Block
- Separate Receive and Transmit Rings
- Variable Descriptor Ring and Window Sizes.
Separate 64-byte Transmit and Receive FIFO.
Programmable Transmit FIFO hold-off watermark.
Handles all HDLC frame formatting:
- Zero bit insertion and deletion
- FCS (CRC) generation and detection
- Frame delimiting with flags
Programmable Single or Extended Address
and Control fields.
Five programmable timer/counters: T1, T3,
TP, N1, N2
Programmable minimum frame spacing on
transmission (number of flags between
frames).
- Programmable from 1 to 62 flags between
frames
Selectable FCS (CRC) of 16 or 32 bits, and
passing of entire FCS to buffer.
Testing Facilities:
- Internal Loopback
- Silent Loopback
- Optional Internal Data Clock Generation
- Self Test.
Programmable for full or half duplex operation
July 1994
DIP48
PLCC 52
Programmable Watchdog Timers for RCLK
and TCLK (to detect absence of data clocks)
Option causing received data to effectively be
odd-byte aligned, in addition to standard evenbyte alignment.
Available in 52 pin PLCC, 84 pin PLCC(for use
with external ROM), or 48 pin DIP packages.
SECTION 2 - INTRODUCTION
The SGS - Thomson MK502H5 Link Level Controller is a VLSI semiconductor device which provides complete link level data communications
control conforming to the 1984 and 1988 CCITT
versions of X.25. The MK50H25 will perform
frame formating including: frame delimiting with
flags, transparency (so-called ”bit-stuffing”), error
recovery by retransmission, sequence number
control, S (supervisory) and U (unnumbered)
frame control, plus FCS (CRC) generation and
detection. The MK50H25 also supports X.75 and
X.32 (with its XID frame support), as well as single channel ISDN LAPD (with its support of UI
frames and extended addressing capabilities).
1/64
MK50H25
DESCRIPTION (Continued)
For added flexibility a transparent mode provides
an HDLC transport mechanism without link layer
support. This flexible transparent mode may be
easily entered and exited without affecting the
X.25 link status or the link state variables kept by
the MK50H25. In this mode no protocol processing is done and it is up to the user to take care of
the upper level software. Single or extended Address field filtering and Control field handling are
optionally supported within the transparent mode.
One of the outstanding features of the MK50H25
is its buffer management which includes on-chip
dual channel DMA. This feature allows users to
receive and transmit multiple data frames at a
time. (A conventional serial communications control chip plus a separate DMA chip would handle
data for only a single block at a time.) The
MK50H25 will move multiple blocks of receive
and transmit data directly into and out of memory
through the Host’s bus. A possible system configuration for the MK50H25 is shown in figure 1.
The MK50H25 may be used with any of several
popular 16 and 8 bit microprocessors, such as
68020, 68000, 6800, Z8000, Z80, 8086, 8088,
80186, 80286, 80386SX, etc.
The MK50H25 may be operated in either full or
half duplex mode. In half duplex mode, the RTS
and CTS modem control pins are provided. In full
duplex mode, these pins become user programmable I/O pins. All signal pins on the MK50H25
are TTL compatible. This has the advantage of
making the MK50H25 independent of the physical
interface. As shown in figure 1, line drivers and
receivers are used for electrical connection to the
physical layer.
DIP48 PIN CONNECTION (Top view)
1
48
VCC (+5V)
DAL07
2
47
DAL08
DAL06
3
46
DAL09
DAL05
4
45
DAL10
DAL04
5
44
DAL11
DAL03
6
43
DAL12
DAL02
7
42
DAL13
DAL01
8
41
DAL14
DAL00
9
M
40
DAL15
READ
10
K
39
A16
INTR
11
A17
DALI
12
5
38
37
A18
36
A19
35
A20
34
A21
33
A22
32
A23
RD
VSS-GND
DALO
DAS
BMO, BYTE , BUSRE L
BMI, BUSAKO
HOLD, BUSRQ
14
15
H
2
16
17
5
ALE, AS
18
31
HLDA
19
30
DSR, CTS
CS
20
29
TD
ADR
21
28
SYSCLK
READY
22
27
RCLK
RESET
23
26
DTR, RTS
24
25
TCLK
VSS-GND
2/64
13
0
MK50H25
No Connect
DAL03
DAL04
DAL05
DAL06
DAL07
VSS
VCC
DAL08
DAL09
DAL10
DAL11
DAL12
PLCC52 PIN CONNECTION (Top view)
DAL02
DAL01
DAL00
READ
INTR
DALI
DALO
8 7
1 52
47 46
MK50H25Q
DAS
BMO/BYTE/BUSREL
No Connect
BM1/BUSAKO
HOLD/BUSRQ
20
21
34
TCLK
DTR/RTS
RCLK
SYSCLK
TD
DSR/CTS
VSS(GND)
No Connect
RESET
33
ADR
READY
HLDA
CS
ALE/AS
DAL13
DAL14
DAL15
A16
A17
A18
A19
A20
A21
A22
No Connect
A23
RD
3/64
MK50H25
TAble 1: PIN DESCRIPTION
LEGEND:
I
Input only
IO
Input / Output
OD
Open Drain (no internal pull-up)
Note:
O
3S
Output only
3-State
Pin out for 52 pin PLCC is shown in brackets.
SIGNAL NAME
PIN(S)
TYPE
DESCRIPTION
DAL<15:00>
2-9
40-47
[2-10
44-51]
IO/3S
The time multiplexed Data/Address bus. During the address portion of a
memory transfer, DAL<15:00> contains the lower 16 bits of the memory
address.
During the data portion of a memory transfer, DAL<15:00> contains the read
or write data, depending on the type of transfer.
READ
10
[11]
IO/3S
READ indicates the type of operation that the bus controller is performing
during a bus transaction. READ is driven by the MK50H25 only while it is the
BUS MASTER. READ is valid during the entire bus transaction and is
tristated at all other times.
MK50H25 as a Bus Slave :
READ = HIGH - Data is placed on the DAL lines by the chip.
READ = LOW - Data is taken off the DAL lines by the chip.
MK50H25 as a Bus Master :
READ = HIGH - Data is taken off the DAL lines by the chip.
READ = LOW - Data is placed on the DAL lines by the chip.
INTR
11
[12]
O/OD
INTERRUPT is an attention interrupt line that indicates that one or more of
the following CSR0 status flags is set: MISS, MERR, RINT, TINT or PINT.
INTERRUPT is enabled by CSR0<09>, INEA=1.
DALI
12
[13]
O/3S
DAL IN is an external bus transceiver control line. DALI is driven by the
MK50H25 only while it is the BUS MASTER. DALI is asserted by the
MK50H25 when it reads from the DAL lines during the data portion of a
READ transfer. DALI is not asserted during a WRITE transfer.
DALO
13
[14]
O/3S
DAL OUT is an external bus transceiver control line. DALO is driven by the
MK50H25 only while it is the BUS MASTER. DALO is asserted by the
MK50H25 when it drives the DAL lines during the address portion of a READ
transfer or for the duration of a WRITE transfer.
DAS
14
[15]
IO/3S
DATA STROBE defines the data portion of a bus transaction. By definition,
data is stable and valid at the low to high transition of DAS. This signal is
driven by the MK50H25 while it is the BUS MASTER. During the BUS
SLAVE operation, this pin is used as an input. At all other times the signal is
tristated.
BMO
BYTE
BUSREL
15
[16]
IO/3S
I/O pins 15 and 16 are programmable through CSR4. If bit 06 of CSR4 is set
to a one, pin 15 becomes input BUSREL and is used by the host to signal
the MK50H25 to terminate a DMA burst after the current bus transfer has
completed. If bit 06 is clear then pin 15 is an output and behaves as
described below for pin 16.
BM1
BUSAKO
16
[18]
O/3S
Pins 15 and 16 are programmable through bit 00 of CSR4 (BCON).
If CSR4<00> BCON = 0,
I/O PIN 15 = BMO (O/3S)
I/O PIN 16 = BM1 (O/3S)
BYTE MASK<1:0> Indicates the byte(s) on the DAL to be read or written
during this bus transaction. MK50H25 drives these lines only as a Bus
Master. MK50H25 ignores the BM lines when it is a Bus Slave.
Byte selection is done as outlined in the following table.
BM1
BM0
TYPE OF TRANSFER
LOW
LOW
ENTIRE WORD
LOW
HIGH
UPPER BYTE
(DAL<15:08>)
HIGH
LOW
LOWER BYTE
(DAL<07:00>)
HIGH
HIGH
NONE
4/64
MK50H25
Table 1: PIN DESCRIPTION (continued)
SIGNAL NAME
PIN(S)
TYPE
DESCRIPTION
If CSR4<00> BCON = 1,
I/O PIN 15 = BYTE (O/3S)
I/O PIN 16 = BUSAKO(O)
Byte selection is done using the BYTE line and DAL<00> latched during the
address portion of the bus transaction. MK50H25 drives BYTE only as a Bus
Master and ignores it when a Bus Slave. Byte selection is done as outlined
in the following table.
BYTE
DAL<00>
TYPE OF TRANSFER
LOW
LOW
ENTIRE WORD
LOW
HIGH
ILLEGAL CONDITION
HIGH
LOW
LOWER BYTE
HIGH
HIGH
UPPER BYTE
BUSAKO is a bus request daisy chain output. If MK50H25 is not requesting
the bus and it receives HLDA, BUSAKO will be driven low. If MK50H25 is
requesting the bus when it receives HLDA, BUSAKO will remain high
Note: All transfers are entire word unless the MK50H25 is configured for 8 bit
operation.
HOLD
BUSRQ
17
[19]
IO/OD
Pin 17 is configured through bit 0 of CSR4.
If CSR4<00> BCON = 0,
I/O PIN 17 = HOLD
HOLD request is asserted by MK50H25 when it requires a DMA cycle, if
HLDA is inactive, regardless of the previous state of the HOLD pin. HOLD is
held low for the entire ensuing bus transaction.
If CSR4<00> BCON = 1,
I/O PIN 17 = BUSRQ
BUSRQ is asserted by MK50H25 when it requires a DMA cycle if the prior
state of the BUSRQ pin was high and HLDA is inactive. BUSRQ is held low
for the entire ensuing bus transaction.
ALE
AS
18
[20]
O/3S
The active level of ADDRESS STROBE is programmable through CSR4.
The address portion of a bus transfer occurs while this signal is at its
asserted level. This signal is driven by MK50H25 while it is the BUS
MASTER. At all other times, the signal is tristated.
If CSR4<01> ACON = 0,
I/O PIN 18 = ALE
ADDRESS LATCH ENABLE is used to demultiplex the DAL lines and define
the address portion of the transfer. As ALE, the signal transitions from high
to low during the address portion of the transfer and remains low during the
data portion.
If CSR4<01> ACON = 1,
I/O PIN 18 = AS
As AS, the signal pulses low during the address portion of the bus transfer.
The low to high transition of AS can be used by a slave device to strobe the
address into a register.
AS is effectively the inversion of ALE.
HLDA
19
[21]
I
HOLD ACKNOWLEDGE is the response to HOLD. When HLDA is low in
response to MK50H25’s assertion of HOLD, the MK50H25 is the Bus
Master. HLDA should be deasserted ONLY after HOLD has been released
by the MK50H25.
CS
20
[22]
I
CHIP SELECT indicates, when low, that the MK50H25 is the slave device
for the data transfer. CS must be valid throughout the entire transaction.
ADR
21
[23]
I
ADDRESS selects the Register Address Port or the Register Data Port. It
must be valid throughout the data portion of the transfer and is only used by
the chip when CS is low.
ADR
PORT
LOW
REGISTER DATA PORT
HIGH
REGISTER ADDRESS PORT
READY
22
[24]
IO/OD
When the MK50H25 is a Bus Master, READY is an asynchronous
acknowledgement from the bus memory that memory will accept data in a
WRITE cycle or that memory has put data on the DAL lines in a READ cycle.
5/64
MK50H25
Table 1: PIN DESCRIPTION (continued)
SIGNAL NAME
PIN(S)
TYPE
DESCRIPTION
As a Bus Slave, the MK50H25 asserts READY when it has put data on the
DAL lines during a READ cycle or is about to take data from the DAL lines
during a WRITE cycle. READY is a response to DAS and it will be released
after DAS or CS is negated.
RESET
23
[25]
I
RESET is the Bus signal that will cause MK50H25 to cease operation, clear
its internal logic and enter an idle state with the Power Off bit of CSR0 set.
TCLK
25
[28]
I
TRANSMIT CLOCK. A 1x clock input for transmitter timing. TD changes on
the falling edge of TCLK. The frequency of TCLK may not be greater than
the frequency of SYSCL
DTR
RTS
26
[29]
IO
DATA TERMINAL READY, REQUEST TO SEND. Modem control pin. Pin
26 is configurable through CSR5. This pin can be programmed to behave as
output RTS or as programmable IO pin DTR. If configured as RTS, the
MK50H25 will assert this pin if it has data to send and throughout the
transmission of a signal unit.
RCLK
27
[30]
I
RECEIVE CLOCK. A 1x clock input for receiver timing. RD is sampled on
the rising edge of RCLK. The frequency of RCLK may not be greater than
the frequency of SYSCLK.
SYSCLK
28
[31]
I
SYSTEM CLOCK. System clock used for internal timing of the MK50H25.
SYSCLK should be a square wave, of frequency up to 33 MHz.
TD
29
[32]
O
TRANSMIT DATA. Transmit serial data output.
DSR
CTS
30
[33]
IO
DATA SET READY, CLEAR TO SEND. Modem Control Pin. Pin 30 is
configurable through CSR5. This pin can be programmed to behave as input
CTS or as programmable IO pin DSR. If configured as CTS, the MK50H25
will transmit all ones while CTS is high.
RD
31
[34]
I
A<23:16>
32-39
[37-43]
o/3s
VSS-GND
1,24
[1,26]
VCC
48
[52]
RECEIVE DATA. Received serial data input.
Address bits <23:16> used in conjunction with DAL<15:00> to produce a 24
bit address. MK50H25 drives these lines only as a Bus Master. A23-A20
may be driven continuously as described in the CSR4<7> BAE bit.
Ground Pins
Power Supply Pin
+5.0 VDC + 5%
SECTION 3
OPERATIONAL DESCRIPTION
The SGS-Thomson MK50H25 Multi-Logical Link
Communications Controller device is a VLSI product intended for high performance data communication applications requiring X.25 link level control. The MK50H25 will perform all frame
formatting, such as: frame delimiting with flags,
FCS (CRC) generation and detection, and zero
bit insertion and deletion for transparency. The
MK50H25 also handles all supervisory (S) and
unnumbered (U) frames (see Tables A & B). The
MK50H25 also includes a buffer management
mechanism that allows the user to transmit and/or
receive multiple frames for each active channel
or DLCI. Contained in the buffer management is
an on-chip dual channel DMA: one channel for receive and one channel for transmit.
6/64
The MK50H25 can be used with any popular 16
or 8 bit microprocessor. A possible system configuration for the MK50H25 is shown in Figure 1.
This document assumes that the processor has a
byte addressable memory organization.
The MK50H25 will move multiple blocks of receive and transmit data directly in and out of
memory through the Host’s bus.
The MK50H25 may be operated in full or half duplex mode. In half duplex mode the RTS and
CTS modem control pins are provided. In full duplex mode, these pins become user programmable I/O pins.
All signal pins on the MK50H25 are TTL compatible. This has the advantage of making the
MK50H25 independent of the physical interface.
As shown in Fig. 1, line drivers and receivers are
used for electrical connection to the physical
layer.
MK50H25
Figure 1: Possible System Configuration for thr MK50H25
HOST PROCESSOR
(68000, 80186, Z8000, ETC)
MEMORY
(MULTIPLE
DATA BLOCKS)
16-BIT DATA BUS INCLUDING
24-BIT ADDRESS AND BUS CONTROL
TD
TCLK
RD
RCLK
DSR, CTS
DTR, RTS
MK50H25
LINE DRIVERS
AND RECEIVERS
ELECTRICAL I/O
(SUCH AS RS-232C, RS-423, RS-422)
DATA COMM. CONNECTOR
(SUCH AS RS-449, RS-232C, V.35)
7/64
MK50H25
INTR
DSR, CTS
ADR
DTR, RTS
CS
BM0
BM1
ALE, AS
HOLD
HLDA
DALO
DALI
A <23:16>
DAL <15:00>
Figure 2: MK50H25 Simplified Block Diagram
READY
READ
DAS
FIRMWARE
ROM
CONTROL / STATUS
REGISTERS 0 - 5
DMA
CONTROLLER
MICRO
CONTROLLER
SYSCLK
INTERNAL BUS
TRANSMITTER
FIFO
RECEIVER
FIFO
VCC
VSS - GND
RESET
RCLK
RECEIVER
TRANSMITTER
RD
TD
LOOPBACK
TEST
8/64
TCLK
TIMERS
MK50H25
3.1 Functional Blocks
Refer to the block diagram in Figure 2.
The MK50H25 is primarily initialized and controlled through six 16-bit Control and Status Registers (CSR0 thru CSR5). The CSR’s are accessed
through two bus addressable ports, the Register
Address Port (RAP), and the Register Data Port
(RDP). The MK50H25 may also generate an interrupt(s) to the Host. These interrupts are enabled and disabled through CSR0.
The on-chip microcontroller is used to control the
movement of parallel receive and transmit data,
and to handle the Address field filtering.
3.1.1 Microcontroller
The microcontroller controls all of the other blocks
of the MK50H25. The microcontroller performs
frame processing and protocol processing. All
primitive processing and generation is also done
here. The microcode ROM contains the control
program of the microcontroller.
3.1.2 Receiver
Serial receive data comes into the Receiver (Figure 2). The Receiver is responsible for:
1. Leading and trailing flag detection.
2. Deletion of zeroes inserted for transparency.
3. Detection of idle and abort sequences.
4. Detection of good and bad FCS (CRC).
5. Monitoring Receiver FIFO status.
6. Detection of Receiver Over-Run.
7. Odd byte detection.
NOTE: If frames are received that have an odd
number of bytes then the last byte of the
frame is said to be an odd byte.
8. Detection of non-octet aligned frames. Such
frames are treated as invalid (CCITT X.25 sec
2.3.5.3)
3.1.3 Transmitter
The Transmitter is responsible for:
1. Serialization of outgoing data.
2. Generating and appending the FCS (CRC).
3. Framing outgoing frame with flags.
4. Zero bit insertion for transparency.
5. Transmitter Under-Run detection.
6. Transmission of odd byte.
7. RTS/CTS control.
3.1.4 Frame Check Sequence or Cyclic
Redundancy Check
The FCS (CRC) on the transmitter or receiver
may be either 16 bit or 32 bit, and is user selectable. For full duplex operation, both the receiver
and transmitter have individual FCS computation
circuits. The characteristics of the FCS are:
Transmitted Polarity: Inverted
Transmitted Order: High Order Bit First
Pre-set Value: All 1’s
Polynomial 16 bit:
X16 + X12 + X5 + 1
Remainder 16 bit (if received correctly):
High order bit-->0001 1101 0000 1111
Polynomial 32 bit:
X32 + X26 + X23 + X22 + X16 + X12 + X11 + X10 +
X8 + X7 + X5 + X4 + X2 + X + 1
Remainder 32 bit (if received correctly):
high order bit-->1100 0111 0000 0100
1101 1101 0111 1011
3.1.5 Receive FIFO
The Receive FIFO buffers the data received by
the receiver. This performs two major functions.
First, it resynchronizes the data from the receive
clock to the system clock. Second, it allows the
microcontroller time to finish whatever it may be
doing before it has to process the received data.
The receive FIFO holds the data from the receiver
without interrupting the microcontroller for service
until it contains enough data to reach the watermark level, or an end of frame is received. This
watermark level can be programmed in CSR4
(FWM) to occur when the FIFO contains at least
18 or more bytes; 34 or more bytes; or 50 or
more bytes. This programmability , along with the
programmable burst length of the DMA controller,
enables the user to define how often and for how
long the MK50H25 must use the host bus. For
more information, see CSR4.
For example, if the watermark level is set at 34
bytes and the burst length is limited to 8 word
transfers at a time, the MK50H25 will request
control of the host bus as soon as 34 bytes are
received and again after every 16 subsequent
bytes.
3.1.6 Transmit FIFO
The Transmit FIFO buffers the data to be transmitted by the MK50H25. This also performs two
major functions. First, it resynchronizes the data
from the system clock to the transmit clock. Second, it allows the microcontroller and DMA controller to burst read data from the host’s memory
buffers; making both the MK50H25 and the host
bus more efficient.
The transmit FIFO has a watermark scheme similar to the one described for the receive FIFO
above, and uses the same FWM value selections
in CSR4 for the watermark. Once filled to within
9/64
MK50H25
FWM of being full (by DMA from TX buffer in
shared memory), the transmit FIFO will not interrupt the microcontroller until it empties enough to
fall below the watermark level.
The transmit FIFO also has a selectable Transmit
Hold-Off watermark mechanism to determine
when data transmission will begin once data has
been put in the transmit FIFO. The Transmit
Hold-Off watermark is enabled by setting bit 10
(XHOLD) in CSR4. The selection of FWM (FIFO
WaterMark) also in CSR4 determines corresponding appropriate values of Transmit Hold-Off
so that the device cannot be inadvertently programmed to have conflicting watermarks. For
FWM settings of 9, 17, and 25 words, the Transmit Hold-Off watermarks are 19, 11, and 3 words
respectively.
For example, if FWM is set at 9 words and the
Transmit Hold-Off watermark is enabled, the
MK50H25 will not begin transmitting until more
than 19 words have been placed in the Transmit
FIFO or an end-of-frame has been transmitted.
This greatly reduces the chances of Transmitter
Underrun that could be possible at high data rates
(ie: TCLK > 0.15 x SYSCLK) if Transmit Hold-Off
is not selected (causing transmission to begin as
soon as 1 byte is transferred to the TX FIFO).
3.1.7 DMA Controller
The MK50H25 has an on-chip DMA Controller circuit. This allows it to access memory without requiring host software intervention. Whenever the
MK50H25 requires access to the host memory it
will negotiate for mastership of the bus. Upon
gaining control of the bus the MK50H25 will begin
transferring data to or from memory.
The
MK50H25 will perform memory transfers until
either it has nothing more to transfer, it has
reached its DMA burst limit (user programmable),
or the BUSREL pin is driven low. In any case, it
will complete all bus transfers before releasing
bus mastership back to the host. If during a
memory transfer, the memory does not respond
within 256 SCLK cycles, the MK50H25 will release ownership of the bus immediately and the
MERR bit will be set in CSR0. The DMA burst
limit can be programmed by the user through
CSR4. In 16 bit mode the limit can be set to 1
word, 8 words, or unlimited word transfers. In 8
bit mode,it can be set to 2 bytes, 16 bytes, or unlimited byte transfers. For high speed data lines
(i.e. > 1 Mbps) a burst limit of 8 words or 16 bytes
is suggested to allow maximum throughput.
The byte ordering of the DMA transfers can be
programmed to account for differences in processor architectures or host programming languages.
Byte ordering can be programmed separately for
data and control information. Data information is
defined as all contents of data buffers; control information is defined as anything else in the
shared memory space (i.e. initialization block, descriptors, etc). For more information see section
10/64
4.1.2.5 on control status register 4.
3.1.8 Bus Slave Circuitry
The MK50H25 contains a bank of internal control/status registers (CSR0-5) which can be accessed by the host as a peripheral. The host can
read or write to these registers like any other bus
slave. The contents of these registers are listed
in Section 4 and bus signal timing is described in
Figures 9 and 10.
3.2 Buffer Management Overview
Refer to Fig. 3.
3.2.1 Initalization Block
Chip initialization information is located in a block
of memory called the Initialization Block. The Initialization Block consists of 25 contiguous words
of memory starting on a word boundary. This
memory is assembled by the HOST, and is accessed by the MK50H25 during initialization. The
Initialization Block is comprised of:
A. Mode of Operation.
B. Frame Address Values.
C. N1 Counter (Max Frame Length) Value.
D. Timer Preset Values
E. Location and size of Receive and Transmit Descriptor Rings.
F. Location and size of XID/TEST Buffers.
G. Location of Status Buffer.
H. Error Counters.
3.2.2 The Circular Queue
The basic organization of the buffer management
is a circular queue of tasks in memory called descriptor rings. There are separate rings to describe the transmit and receive operations. Up to
128 buffers may be queued-up on a descriptor
ring awaiting execution by the MK50H25. The
descriptor ring has a descriptor assigned to each
buffer. Each descriptor holds a pointer for the
starting address of the buffer, and holds a value
for the length of the buffer in bytes.
Each descriptor also contains two control bits
called OWNA and OWNB, which denote whether
the MK50H25, the HOST, or the I/O ACCELERATION PROCESSOR ( if present ) ”owns” the buffer. For transmit, when the MK50H25 owns the
buffer, the MK50H25 is allowed and commanded
to transmit the buffer. When the MK50H25 does
not own the buffer, it will not transmit that buffer.
For receive, when the MK50H25 owns a buffer, it
may place received data into that buffer. Conversely, when the MK50H25 does not own a receive buffer, it will not place received data into
that buffer.
The MK50H25 buffer management mechanism
will handle frames which are longer than the
length of an individual buffer. This is done by a
chaining method which utilizes multiple buffers.
The MK50H25 tests the next descriptor in the de-
MK50H25
scriptor ring in a ”look ahead” manner. If the
frame is too long for one buffer, the next buffer
will be used after filling the first buffer; that is,
”chained”. The MK50H25 will then ”look ahead”
to the next buffer, and chain that buffer if necessary, and so on.The operational parameters for
the buffer management are defined by the user in
the initialization block. The parameters defined
include the basic mode of operation, the number
of entries for the transmitter and receiver descriptor rings, frame Address field, etc. The starting
address for the Initialization block, IADR, is defined in the CSR2 and CSR3 registers inside the
MK50H25.
3.2.3 Frame Format
The frame format supported by the MK50H25 is
shown below. Each frame may consist of a programmable number of leading flag patterns
(01111110), an address field, a control field, an
information field, an FCS (CRC) of either 16 or 32
bits, and a trailing flag pattern. The number of
leading flags transmitted is programmable
through the Mode Register in the Initialization
Block. Received frames may have as few as one
flag between adjacent frames
TRANSMITTED FIRST
F
A
C
INFO
8
8/16
8/16
8*n
FCS
F
16/32
8
3.2.4 The Command/Response Repertoire
The command/response repertoire of the
MK50H25 is shown in Tables A and B. This set
conforms to the 1984 & 1988 CCITT X.25, plus
support of XID, Test, and UI frames conforming to
ISDN LAPD. The MK50H25 will process the Information, Supervisory, and Unnumbered frames
shown in Tables A and B, and will handle the A
and C fields for all I and UI frames.
The symbols and definitions for the frame types
are:
Name
Definition
I
Information frame
UI
Unnumbered Information frame
RR
Receiver Ready
RNR
Receiver Not Ready
REJ
Reject
FRMR
Frame Reject
UA
Unnumbered Acknowledge
SABM
Set Asynchronous Balance Mode
DISC
Disconnect
DM
Disconnect Mode
TEST
Link Test Frame
XID
Exchange Identification
11/64
MK50H25
Table A - MK50H25 Command/Response Repertoire
Modulo 8 Operation
FORMAT
COMMAND
RESPONSE
ENCODING
LSB
MSB
1
2
3
4
5
6
7
8
P
← N(R) →
Information Transfer
I
I
0
← N(S) →
Supervisory
RR
RR
1
0
0
0
P/F ← N(R) →
RNR
RNR
1
0
1
0
P/F ← N(R) →
REJ
REJ
1
0
0
1
P/F ← N(R) →
*
*
1
1
0
0
P/F 0
0
0
1
1
1
1
P
1
0
0
1
1
1
1
F
0
0
0
1
1
0
0
P
0
1
0
UA
1
1
0
0
F
1
1
0
FRMR
1
1
1
0
F
0
0
1
*
XID
1
1
1
1
P/F 1
0
1
TEST
1
1
0
0
P/F 1
1
1
Unnumbered
UI
UI
SABM
DM
DISC
*
XID
TEST
Table B - MK50H25 Command/Response Repertoire
Modulo 128 Operation
FORMAT
COMMAND
RESPONSE ENCODING
LSB
1
MSB
2
3
4
5
6
7
8
9
10-16
P
N(R)
Information
Transfer
I
I
0
Supervisory
RR
RR
1
0
0
0
0
0
0
0
P/F N(R)
RNR
RNR
1
0
1
0
0
0
0
0
P/F N(R)
REJ
REJ
1
0
0
1
0
0
0
0
P/F N(R)
1
1
1
1
P
1
1
0
N/A
Unnumbered
SABME
All Others
All Others
N(S)
Same Repertoire and Encoding as for Modulo 8
Notes:
1. N(S) = Transmitter Send Sequence Number
2. N(R) = Transmitter Receive Sequence Number
3. P/F = Poll bit when issued as a command. Final bit when issued as a response.
4. N/A = Not Applicable. All Unnumbered frames have only an 8 bit Control Field for Modulo 128 or Modulo 8 operation.
*XID and UI frames can be enabled individually by setting the appropriate bits in CSR2.
12/64
MK50H25
Figure 3: MK50H25 Memory Management Structure
RECEIVE BUFFER
CSR 2, CSR3
POINTER TO
RECEIVER DESCRIPTOR RINGS
BUFFER
0
INITIALIZATI ON BLOCK
DESCRIPTOR 0
BUFFER STAT US
BUFFER ADDRESS
BUFF ER SIZE
BUFFER
1
BUFFER MSG COUNT
DESCRIPTOR 1
INITIALIZATI ON BLOCK
BUFFER
M
MODE
FRAME ADDRESS
FIELDS
DESCRIPTOR M
TIMER VALUES
RX DESCRIPTOR
POINTER
TRANSMIT DESCRIPTOR RINGS
TX DESCRIPTOR
POINT ER
DESCRIPTOR 0
BUFFER STATUS
TRAN SMIT BUFFER
BUFFER
0
XID/TEST TRANSMIT
DESCRIPTOR POINTER
XID/TEST RECEIVE
BUFFER ADDRESS
BUFF ER SIZE
DESCRIPTOR POINTER
STATUS
BUFFER ADDRESS
BUFFER MSG COUNT
BUFFER
1
DESCRIPTOR 1
ERROR COUNTERS
STATUS BUFFER
BUFFER
N
XID/T EST
DESCRIPTOR N
RECEIVE BUFFER
XID/TEST
TRANSMIT BUFFER
13/64
MK50H25
SECTION 4
PROGRAMMING SPECIFICATION
This section defines the Control and Status Registers and the memory data structures required to
program the MK50H25.
4.1 Control and Status Registers
There are six Control and Status Registers
(CSR’s) resident within the MK50H25. The
CSR’s are accessed through two bus addressable ports, an address port (RAP), and a data
port (RDP), thus requiring only two locations in
the system memory or I/O map.
4.1.1 Accessing the Control & Status Registers
The CSR’s are read (or written) in a two step operation. The address of the CSR is written into the
address port (RAP) during a bus slave transaction. During a subsequent bus slave transaction,
the data being read from (or written into) the data
port (RDP) is read from (or written into) the CSR
selected in the RAP. Once written, the address in
RAP remains unchanged until rewritten or upon a
bus reset. A control I/O pin (ADR) is provided to
distinguish the address port from the data port.
ADR Port
L Register Data Port (RDP)
H Register Address Port (RAP)
4.1.1.1 Register Address Port (RAP)
1
5
0
1
4
0
1
3
0
1
2
0
1
1
0
1
0
0
0
9
0
0
8
0
0
7
B
M
8
0
6
0
0
5
0
0
4
0
0
3
0
2
CSR
<2:0>
0
1
0
0
H
B
Y
T
E
BIT
NAME
15:08
RESERVED
07
BM8
06:04
RESERVED
03:01
CS3<2:0>
CSR address select bits. READ/WRITE. Selects the CSR to be accessed through the
RDP. RAP is cleared by Bus RESET.
CSR<2:0> CSR
0
CSR0
1
CSR1
2
CSR2
3
CSR3
4
CSR4
5
CSR5
00
HBYTE
Determines which byte is addressed for 8 bit mode. If set, the high byte of the register
referred to by CSR<2:0> is addressed, otherwise the low byte is addressed. This bit is
only meaningful in 8 bit mode and must be written as zero if BM8=0. HBYTE is
READ/WRITE and cleared on bus reset.
14/64
DESCRIPTION
Must be written as zeroes
When set, places chip into 8 bit mode. CSR’s, Init Block, and data transfers are all 8 bit
transfers; this provides compatibility with 8 bitmicroprocessors. When clear, all transfers
are 16 bit transfers. This bit must be set to the same value each time it is written,
changing this bit during normal operation will achieve unexpected results. BM8 is
READ/WRITE and cleared on Bus RESET.
Must be written as zeroes
MK50H25
4.1.1.2 Register Data Port (RDP)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
CSR
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
DATA
BIT
NAME
DESCRIPTION
15:00
CSR DATA
Writing data to the RDP loads data into the CSR selected by RAP. Reading the data from
RDP reads the data from the CSR selected in RAP.
15/64
MK50H25
4.1.2 Control and Status Register Definition
4.1.2.1 Control and Status Register 0 (CSR0)
RAP<3:1> = 0
BIT
15
NAME
TDMD
14
STOP
13
DTX
12
DRX
11
TXON
10
RXON
16/64
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
P
T
D
M
D
S
T
O
P
D
T
X
D
R
X
T
X
O
N
R
X
O
N
I
N
E
A
I
N
T
R
M
E
R
R
M
I
S
S
R
O
R
T
U
R
P
I
N
T
T
I
N
T
R
I
N
T
0
DESCRIPTION
TRANSMIT DEMAND, when set, causes the MK50H25 access the
Transmit Descriptor Ring without waiting for the Transmit poll time interval to lapse. TDMD need not be set to transmit a frame, it merely
hastens the MK50H25’s response to a Transmit Descriptor Ring entry
insertion by the host. TDMD is written with ONE ONLY and cleared by
the MK50H25 microcode after it is used. It may read as a ”1” for a
short time after it is written because the microcode may have been
busy when TDMD was set. It is also cleared by Bus RESET. Writing a
”0” in this bit has no effect.
STOP, when set, indicates that MK50H25 is operating in the Stopped
phase of operation. All external activity is disabled and internal logic is
reset. MK50H25 remains inactive except for primitive processing until
a START primitive is issued. STOP IS READ ONLY and set by Bus
RESET or a STOP primitive. Writing to this bit has no effect.
Disable Transmitter ring prevents the MK50H25 from further access to
the Transmitter Descriptor Ring. No transmissions are attempted after
finishing transmission of any frame in transmission at the time of DTX
being set. TXON acknowledges changes to DTX, see below. DTX is
READ/WRITE.
Disable the Receiver prevents the MK50H25 from further access to the
Receiver Descriptor Ring. No received frames are accepted after finishing reception of any frame in reception at the time of DRX being set.
If DRX is set while a data link is established, the MK50H25 will go into
the Local Busy state and will send an RNR response frame to the remote station. Upon clearing DRX the MK50H25 will send a RR response frame. RXON acknowledges changes to DRX, see description
of RXON. DRX is READ/WRITE.
TRANSMITTER ON indicates that the transmit ring access is enabled.
TXON is set as the Start primitive is issued if the DTX bit is ”0” or afterward as DTX is cleared. TXON is cleared upon recognition of DTX being set, by sending a Stop primitive in CSR1, or by a Bus RESET. If
TXON is clear, the host may modify the Transmit Descriptor Ring entries regardless of the state of the OWNA bits. TXON is READ ONLY;
writing to this bit has no effect.
RECEIVER ON indicates that the receive ring access is enabled.
RXON is set as the Start primitive is issued if the DRX bit is ”0” or afterward as DRX is cleared. RXON is cleared upon recognition of DRX
being set, by sending a Stop primitive in CSR1, or by a Bus RESET. If
RXON is clear, the host may modify the Receive Descriptor Ring entries regardless of the state of the OWNA bits. RXON is READ ONLY;
writing to this bit has no effect.
MK50H25
09
INEA
08
INTR
07
MERR
06
MISS
05
ROR
04
TUR
03
PINT
02
TINT
INTERRUPT ENABLE allows the INTR I/O pin to be driven low when
the Interrupt Flag is set. If INEA = 1 and INTR = 1 the INTR I/O pin will
be low. If INEA = 0 the INTR I/O pin will be high, regardless of the
state of the Interrupt Flag. INEA is READ/WRITE set by writing a
”1” into this bit and is cleared by writing a ”0” into this bit, by Bus RESET, or by issuing a Stop primitive. INEA may not be set while in the
Stopped phase.
INTERRUPT FLAG indicates that one or more of the following interrupt
causing conditions has occurred: MISS, MERR, RINT, TINT, PINT,
TUR or ROR. If INEA = 1 and INTR = 1 the INTR I/O pin will be low.
INTR is READ ONLY, writing this bit has no effect. INTR is cleared as
the specific interrupting condition bits are cleared. INTR is also
cleared by Bus RESET or by issuing a Stop primitive.
MEMORY ERROR is set when the MK50H25 is the Bus Master and
READY has not been asserted within 256 SYSCLKs (25.6 usec @
10MHz) after asserting the address on the DAL lines. When a Memory Error is detected, the MK50H25 releases the bus, the receiver
and transmitter are turned off, and an interrupt is generated if INEA =
1. MERR is READ/CLEAR ONLY and is set by the chip and cleared by
writing a ”1” into the bit. Writing a ”0” has no effect. It is cleared by
Bus RESET or by issuing a Stop primitive.
MISSED frame is set when the receiver loses a frame because it does
not own a receive buffer indicating loss of data. When MISS is set,
RXON is cleared and an interrupt will be generated if INEA = 1. If
MISS is set while a data link is established, the MK50H25 will go into
the Local Busy state and will send an RNR response frame to the remote station. Upon clearing MISS the MK50H25 will send a RR response frame. MISS is READ/CLEAR ONLY and is set by MK50H25
and cleared by writing a ”1” into the bit. Writing a ”0” has no effect. It
is also cleared by Bus RESET or by issuing a Stop primitive.
RECEIVER OVERRUN indicates that the Receiver FIFO was full when
the receiver was ready to input data to the Receiver FIFO. When ROR
occurs, the receive FIFO will be flushed and the buffer(s) containing
any part of the frame already received will be re-used by the next incomming frame. Therefore, the frame being received is lost, but is typically recoverable through the protocol used. When ROR is set, an interrupt is generated if INEA = 1. ROR is READ/CLEAR ONLY and
is set by MK50H25 and cleared by writing a ”1” into the bit. Writing a
”0” has no effect. It is also cleared by Bus RESET or by issuing a Stop
primitive.
TRANSMITTER UNDERRUN indicates that the MK50H25 has aborted
a frame since data was late from memory. This condition is reached
when the transmitter and transmitter FIFO both become empty while
transmitting a frame. The frame in transmission at the time will be
aborted. When TUR is set, an interrupt is generated if INEA = 1. TUR
is READ/CLEAR ONLY and is set by MK50H25 and cleared by writing
a ”1” into the bit. Writing a ”0” has no effect. It is also cleared by Bus
RESET or by issuing a Stop primitive.
PRIMITIVE INTERRUPT is set after the chip updates the primitive
register to issue a provider primitive. When PINT is set, an interrupt is
generated if INEA =1. PINT is READ/CLEAR ONLY and is set by
MK50H25 and cleared by writing a ”1” into the bit. Writing a ”0” has no
effect. It is also cleared by Bus RESET or by issuing a Stop primitive.
TRANSMITTER INTERRUPT is set after the chip updates an entry in
the Transmit Descriptor Ring. This occurrs when a transmitted I frame
has been acknowledged by the remote station. When transmitting UI
frames, or in Transparent Mode, TINT is set upon completing transmission of the frame. When TINT is set, an interrupt is generated if INEA
= 1. TINT is READ/CLEAR ONLY and is set by the MK50H25 and
17/64
MK50H25
01
RINT
00
0
cleared by writing a ”1” into the bit. Writing a ”0” has no effect. It is
also cleared by Bus RESET or by issuing a Stop primitive.
RECEIVER INTERRUPT is set after the MK50H25 updates an entry in
the Receive Descriptor Ring. This occurs when the MK50H25 has successfuly received an I, UI, or FRMR frame, and any good frame in
Transparent Mode. When RINT is set, an interrupt is generated if
INEA = 1. RINT is READ/CLEAR ONLY and is set by the MK50H25
and cleared by writing a ”1” into the bit. Writing a ”0” has no effect. It is
cleared by Bus RESET or by issuing a Stop primitive.
This bit is READ ONLY and will always read as a zero.
4.1.2.2 Control and Status Register 1 (CSR1)
RAP <3:1> = 1
BIT
15
NAME
UERR
14
UAV
13
UPARM
12:08
1
4
U
E
R
R
U
A UPARM
<1:0>
V
UPRIM
0
1
18/64
1
5
1
3
1
2
1
1
1
0
0
9
UPRIM
< 3:0 >
0
8
0
7
0
6
0
5
0
4
P
L
O
S
T
P
A
V
P
P
A
R
M
1
:
0
0
3
0
2
0
1
0
0
PPRIM
< 3:0 >
DESCRIPTION
USER PRIMITIVE ERROR is set by the MK50H25 when a primitive is
issued by the user which is in conflict with the current status of the
chip. UERR is READ/CLEAR ONLY and is set by MK50H25 and
cleared by writing a ”1” into the bit. Writing a ”0” in this bit has no
effect. It is also cleared by Bus RESET.
USER PRIMITIVE AVAILABLE is set by the user when a primitive is
written into UPRIM. It is cleared by the MK50H25 after the primitive
has been processed. This bit is also cleared by a Bus RESET.
USER PARAMETER is written by the host in conjunction with the user
primitives in UPRIM. This User Parameter field provides information to
the MK50H25 concerning the corresponding user primitive. For connect and reset primitives this field determines what the MK50H25 will
do with frames in the transmit descriptor ring which have previously
been sent but not acknowledged. If UPARM = 0, these frames will be
resent when the new link is established. If UPARM = 1, these frames
will be discarded and their OWNA bits cleared, releasing ownership
back to the host. For other primitives UPARM = 0 unless otherwise indicated.
USER PRIMITIVE is written by the user, in conjunction with setting
UAV, to control the MK50H25 link procedures. The following primitives
are available:
Stop: Causes MK50H25 to enter the Stopped mode or phase. All DMA
activity ceases, the transmitter transmits all ones, and all received data
is ignored. A Stop primitive issued during transmission of a frame will
cause the frame to be aborted as the Transmitter outputs 1’s. A Stop
primitive issued with UPARM=1 will cause a software Reset of the
MK50H25 (equivalent to asserting the RESET pin).
Start: Instructs the MK50H25 to exit the Stopped Mode and enter the
Disconnected phase, if UPARM = 0. The descriptor Rings are reset.
The transmitter begis to output flags. If issued with UPARM = 1 the
MK50H25 will directly enter the Information Transfer phase (link connected).Valid only in Stopped Mode or Transparent Mode.
MK50H25
2
3
4
5
6
7
8
9
10
11
12
13
14
07
PLOST
06
PAV
Init: Instructs the MK50H25 to read the Initialization Block from memory.
Valid only in the Stopped mode or phase. This should be performed
prior to the Start primitive after a bus reset or power-up.
Trans: Instructs MK50H25 to enter the Transparent Mode of operation.
Data frames are transmitted and received out of the descriptor rings
with no Address and Control fields prepended to the frames. If the
PROM bit is set in the Protocol Parameters register, then no address
filtering is performed on received frames. Transparent Mode may be
exited with a Stop primitive or by a bus reset. Exiting from Transparent
Mode to the information transfer phase (link connected) is possible by
issuing a Start primitive with UPARM = 1, or to the Disconnected phase
by issuing Start with UPARM = 0.
Status Request: Instructs the MK50H25 to write the current chip status
into the STATUS BUFFER. Valid in all states, but only after the Init
primitive has been previously issued.
Self-Test Request: Instructs the MK50H25 to perform the built in internal
self test. Valid only in the Stopped phase. A Self Test primitive issued
with UPARM=3 will cause the device to identify itself by returning a
Provider primitive of 5 (or 7 for the MK50H27, etc). See section 4.4.12
for the self test procedure.
Connect Request: Instructs the MK50H25 to attempt to establish a logical
link with the remote station. Valid only in Disconnected phase .
Connect Response: Indicates willingness to establish a logical link with
the remote station. Valid only in Disconnected phase after receiving a
Connect Indication primitive.
Reset Request: If a logical link has been established, it instructs the
MK50H25 to attempt to reset the current link with the remote station. In
Transparent Mode or Disconnected Phase, it instructs the MK50H25 to
start the T1 timer (to be used as a general purpose timer).
Reset Response: If a logical link has been established, it indicates
willingness to reset the current logical link with remote station. Valid
only after receiving Reset Indication primitive. In Transparent Mode or
Disconnected Phase, it instructs the MK50H25 to stop the T1 timer.
XID Request: Instructs the MK50H25 to send a XID frame to the remote
station. Data in the XID/Test Transmit buffer is used for the Data Field.
Invalid in Stopped Mode.
XID Response: Instructs the MK50H25 to send an XID response frame to
the remote station. Data in the XID/TEST Transmit buffer is used for
the data field. Valid only after receiving an XID Indication primitive.
TEST Request: Instructs MK50H25 to send a TEST command to the
remote station. Data in the XID/TEST Transmit buffer is used for the
data field. Invalid in Stopped mode.
TEST Response: Instructs MK50H25 to send a TEST response frame to
the remote station. Data in XID/TEST Transmit buffer is used for the
data field. Valid only after receiving TEST Indication primitive.
Disconnect Request: Instructs the MK50H25 to disconnect the current
logical link and enter the Normal Disconnected phase. If the link is currently disconnected, issuing Disconnect Request with UPARM=0 will
cause a DM/F=0 frame to be sent; issuing it with UPARM=1 will cause
a DISC/P=0 frame to be sent.
PROVIDER PRIMITIVE LOST is set by the MK50H25 when a provider
primitive cannot be issued because the PAV bit is still set from the previous provider primitive. PLOST is cleared when PAV is cleared or by
a Bus RESET. Writing to this bit has no effect.
PROVIDER PRIMITIVE AVAILABLE is set by the MK50H25 when a new
provider primitive has been placed in PPRIM. PAV is READ/CLEAR
19/64
MK50H25
05:04
PPRIM
PPARM
Disconnect
Indication
ONLY and is set by the chip and cleared by writing a ”1” to the bit or by
Bus RESET. Under normal operation the host should clear the PAV bit
after PPRIM is read.
PROVIDER PARAMETER provides additional information about the
reason for the receipt of certain primitives. The following table shows
the parameters for the applicable provider primitives. This field is undefined for other provider primitives.
Disconnect
Confirmation
Reset
Indication
Error
Indication
Remote Busy
Indication
PPARM
0
Remotely
Initiated
UA or DM F=1
Received
1
SABM Timeout
DISC Timeout
2
FRMR Sent the
DISC or DM
Rcvd.
3
T3 Timeout
03:00
PPRIM
2
3
4
5
6
7
8
9
10
20/64
Remotely
Initiated
FRMR Sent
then SABM/E
Received
T3 Timeout
Unsolicited
DM/F=0 Rcvd
Remote Busy
RNR Received
Timer
Recovery
Timeout
Remote UnBusy RR or
REJ Rcvd.
FRMR
Received
Unsolicited Ua
or F bit
Received
PROVIDER PRIMITIVE is written by the MK50H25, in conjunction with
with setting the PAV bit, to inform the user of link control conditions.
Valid Provider Primitives are as follows:
Init Confirmation: Indicates MK50H25 Init Block reading has completed.
Watchdog Timer Expiry Indication: Indicates expiration of TCLK or RCLK
watchdog timer as determined by the value of PPARM. (PPARM=1indicates TCLK, PPARM=2 indicates RCLK If PLOST is set it indicates
both RCLK and TCLK watchdog timer expiry). Issued only if enabled.
Error Indication: Indicates an Error condition has occurred during the
Information Transfer phase that requires instruction by the Host for recovery. See the PPARM table for specific error conditions. Appropriate
Host responses are Connect Response or Disconnect Request.
Remote Busy Indication: Indicates change in the Remote Busy status of
the MK50H25. See PPARM table for specific conditions. This primitive
is only generated if RBSY (bit 11 of IADR+16) is set = 1.
Connect Indication: Indicates attempt by the Primary station to establish
a logical link (SABM received). Appropriate user responses are Connect Response or Disconnect Request.
Connect Confirmation: Indicates sucess of a previous Connect Request
by the user. A logical link is now established.
Reset Indication: If a logical link has been established, it indicates an
attempt by the Primary station to reset the current logical link (SABM
received). Appropriate user responses are Reset Response or Disconnect Request. In Transparent Mode or Disconnected Phase, it indicates expiry of timer T1.
Reset Confirmation: Indicates sucess of a previous Reset Request by
the user. The current logical link has now been reset.
XID Indication: Indicates the receipt of an XID command. The data field
MK50H25
of the XID command is located in the XID/TEST Receive buffer.
Valid only if XIDE bit in CSR2 is set.
11
XID Confirmation: Indicates the receipt of an XID response. The data
field of the XID command is located in the XID/TEST Receive buffer.
Valid only if XIDE bit in CSR2 is set.
12
TEST Indication: Indicates the receipt of TEST command. The data field
of the TEST command is located in the XID/TEST Receive buffer.
13
TEST Confirmation: Indicates the receipt of an TEST response. The data
field of the XID command is located in the XID/TEST Receive buffer.
Valid only if XIDE bit in CSR2 is set.
14
Disconnect Indication: Indicates request by the remote station to disconnect
the current logical link (DISC received), or the refusal of a previous
Connect or Reset Request. The chip is now in the Disconnected
phase.
15
Disconnect Confirmation: Indicates the completion of a previously
requested link disconnection.
4.1.2.3 Control and Status Register 2 (CSR2)
RAP<3:1> = 2
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
C
Y
C
L
E
E
I
B
E
N
F
R
M
R
D
T
2
0
3
E
X
7
5
E
P
R
O
M
U
I
E
X
I
D
E
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
IADR<23:16>
BIT
NAME
DESCRIPTION
15
CYCLE
14
EIBEN
13
FRMRD
12
T203E
11
X75E
10
PROM
9
UIE
8
XIDE
Setting this bit selects a shorter DMA cycle (5 vs 6 SYSCLKs for bursting
or 5 vs 7 SYSCLKs for single DMA). See Figures 7a and 8a for details.
Extended Initialization Block Enable. Setting this bit will cause the
MK50H25 to use an extended Initialization Block which uses all of
IADR+08 as a 16-bit scaler, moves N2 to the upper byte of IADR+40,
and extends the Init Block past IADR+55. This bit is READ/WRITE.
Setting this bit disables the sending of FRMR frames (used for LAPD
applications); otherwise the MK50H25 behaves as specified for X.25.
This bit is READ/WRITE.
If this bit is set, the T3 timer is reconfigured to behave as specified for
LAPD T203 timer; otherwise it behaves as specified for X.25. The operation of the T203 timer is that it expires after T203 time of not having
received any type of frame, and causes a RR/P=1 polling (Timer Recovery) procedure to begin. This bit is READ/WRITE.
X.75 mode of protocol operation is enabled if this bit is set to 1;
otherwise X.25 mode is enabled. This bit is READ/WRITE.
Address filtering is disabled for Transparent Mode if this bit is set. All
uncorrupted incomming frames are placed in the Receive Descriptor
Ring. This bit is READ/WRITE and should be set only in Transparent
Mode.
UI frames are recognized only if this bit is set. If UIE=0 all received UI
frames will not be recognized. This bit is READ/WRITE.
XID frames are recognized only if this bit is set. If XIDE=0 all received
XID frames will not be recognized. This bit is READ/WRITE.
21/64
MK50H25
07:00
IADR
The high order 8 bits of the address of the first word (lowest address)
in the Initialization Block. IADR must be written by the Host prior to
issuing an INIT primitive.
4.1.2.4 Control and Status Register 3 (CSR3)
RAP<3:1> = 3
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
IADR <15:00>
BIT
15:00
0
NAME
IADR
DESCRIPTION
The low order 16 bits of the address of the first word (lowest address)
in the Initialization Block. Must be written by the Host prior to issuing
an INIT primitive. The Initialization block must begin on an even byte
boundary.
4.1.2.5 Control and Status Register 4 (CSR4)
CSR4 allows redefinition of the bus master interface.
RAP<3:1> = 4
1
5
1
4
1
3
1
2
1
1
1
0
X
W
D
1
X
W
D
0
R
W
D
1
R
W
D
0
R
O
B
A
X
H
O
L
D
BIT
15:12
NAME
XWD0/1, RWD0/1
11
ROBA
10
XHOLD
22/64
0
9
0
8
F
W
M
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
B
A
E
B
U
S
R
B
S
W
P
C
B
U
R
S
T
1
:
0
B
S
W
P
D
A
C
O
N
B
C
O
N
DESCRIPTION
These bits enable and determine the timer values for the Transmit and
Receive Watchdog Timers. These timers are independently programmable and are reset by any transition on the TCLK and RCLK pins respectively. The Watchdog timers will expire after approximately Wn
SYSCLK cycles (if not reset by transition on TCLK / RCLK pins) and
Provider Primitive 3 will be issued. The following table shows the selections for Wn:
XWD1/RWD1
XWD0/RWD0
Wn
0
0
Disabled
0
1
218
1
0
219
1
1
220
Setting this bit will cause the MK50H25 to put the first byte of received
data into both the upper and lower bytes of the receive buffer to effectively cause the Receive data to be Odd-Byte Aligned. This feature is
particularly useful for extraction of odd-byte Level 3 headers from received frames leaving the remaining data even byte aligned.
Setting this bit enables the Transmit FIFO Hold-off mechansim of the
MK50H25. The Transmit FIFO Hold-off watermark is selected along
with the FIFO watermark so as to avoid possible conflicts.
MK50H25
09:08
07
06
05
FWM
These bits define the FIFO watermarks. FIFO watermarks prevent the
MK50H25 from performing DMA transfers to/from the data buffers until
the FIFOs contain a minimum amount of data or space for data. For receive, data will only be transferred to the buffers after the FIFO has at
least N 16-bit words or end of frame has been reached. Conversely, for
transmit, data will only be transferred from the data buffers when the
transmit FIFO has room for at least N words of data. The Transmit
Threshold FIFO Watermark is also defined by these bits. If enabled by
setting XHOLD=1, the transmitter will be held-off from transmitting a
new frame until the transmit FIFO has at least N words of data, or the
entire frame has been placed in the FIFO. The N is defined as follows:
FWM<1:0>
FWM N
XHOLD N
11
Not Allowed
Not Allowed
* Suggested setting
10*
9 words
19 words
01
17 words
11 words
00
25 words
3 words
BAE
Bus Address Enable: If BAE is set, the A23-A20 pins are driven by the
MK50H25 constantly providing the ability to use A23-A20 for memory
bus selection. If clear, A23-A20 behave identically to A19- A16.
BUSR
If this bit is set, pin 15 becomes input BUSREL. If this bit is clear
then pin 15 is either BM0 or BYTE depending on bit 00. For more information see the description for pin 15 in this document. BUSR is
READ/WRITE and cleared on bus Reset.
BSWPC
This bit determines the byte ordering of all ”non-data” DMA transfers.
This transfers refers to any DMA transfers that access memory other
than the data buffers themselves. This includes the Initialization Block,
Descriptors, and Status Buffer. It has no effect on data DMA transfers.
BSWPC allows the MK50H25 to operate with memory organizations
that have bits 07:00 at even addresses and with bits 15:08 at odd addressses or vice versa. BSWPC is Read/Write and cleared by BUS
RESET.
With BSWPC = 1:
Address
XX0
0
...
7
With BSWPC = 0:
Address
XX0
04:03
02
BURST
BSWPD
8
...
15
Address
XX1
8
...
15
...
7
Address
XX1
0
This field determines the maximum number of data transfers performed
each time control of the host bus is obtained. BURST is READ/WRITE
and cleared on bus Reset.
BURST <1:0>
8 bit mode
16 bit mode
00
2 bytes
1 words
10*
16 bytes
8 words
01
unlimited
unlimited
* Suggested setting
This bit determines the byte ordering of all data DMA transfers.
Data transfers are those to or from a data buffer. BSWPD has no effect on non-data transfers. The effect of BSWPD on data transfers is
the same as that of BSWPC on non-data transfers (see
above). For most applications, this bit should be set.
23/64
MK50H25
01
00
ACON
ALE CONTROL defines the assertive state of pin 18 when the
MK50H25 is a Bus Master. ACON is READ/ WRITE and cleared by
Bus RESET.
BCON
ACON
PIN18
NAME
0
ASSERTED HIGH
ALE
1
ASSERTED LOW
AS
BYTE CONTROL redefines the Byte Mask and Hold I/O pins.
BCON is READ/WRITE and cleared by Bus RESET.
BCON
PIN16
PIN15
0
BM1
BM0
PIN17
HOLD
1
BUSAKO
BYTE
BUSRQ
4.1.2.6 Control and Status Register 5 (CSR5)
CSR5 facilitates control and monitoring of modem controls.
RAP<3:1> = 5
1
5
0
BIT
15:06
5
NAME
0
XEDGE
4
RTSEN
3
DTRD
2
DSRD
1
DTR
24/64
1
4
0
1
3
0
1
2
0
1
1
0
1
0
0
0
9
0
0
8
0
0
7
0
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
X
E
D
G
E
R
T
S
E
N
D
T
R
D
D
S
R
D
D
T
R
D
S
R
DESCRIPTION
Reserved, must be written as zeroes.
Setting this bit causes the TD output to change on the rising edge of
TCLK rather than on the falling edge as indicated in the description of
pin 25. This may be useful at high TCLK rates where internal delays
may cause application required TD to TCLK setup times to otherwise
be violated.
RTS/CTS ENABLE is a READ/WRITE bit used to configure pins 26
and 30. If this bit is set, pin 26 becomes RTS and pin 30 becomes
CTS. RTS is driven low whenever the MK50H25 has data to transmit and is kept low during transmission. RTS will be driven high
after the closing flag of a signal unit is transmited if either no other
frames are in the FIFO or if the minimum signal unit spacing is higher
than 2 (see Mode Register). The MK50H25 will not begin transmission
and TD will remain HIGH if CTS is high. If RTSEN = 0 then pins 26
and 30 become programmable I/O pins DTR and DSR. The direction
and behavior of DSR and DTR are controlled by the following bits.
DTR DIRECTION is a READ/WRITE bit used to control the direction
of the DTR/RTS pin. If DTRD = 0, the DTR/RTS pin becomes an input
pin and the DTR bit reflects the current value of the pin; if DTRD = 1,
the DTR/RTS pin is an output pin controlled by the DTR bit below.
DSR DIRECTION is a READ/WRITE bit used to control the direction
of the DSR/CTS pin. If DSRD = 0, the DSR/CTS pin becomes an input
pin and the DSR bit reflects the current value of the pin; if DSRD = 1,
the DSR/CTS pin is an output pin controlled by the DSR bit below.
DATA TERMINAL READY is used to control or observe the DTR I/O
pin depending on the value of DTRD. If DTRD = 0, this bit becomes READ ONLY and always equals the current value of the
DTR/RTS pin. If DTRD = 1, this bit becomes READ/WRITE and
any value written to this bit appears on the DTR/RTS pin.
MK50H25
0
DSR
DATA SET READY is used to control or observe the DSR I/O
pin depending on the value of DSRD. If DSRD = 0, this bit becomes READ ONLY and always equals the current value of the
DSR/CTS pin. If DSRD = 1 this bit becomes READ/WRITE and
any value written to this bit appears on the DSR/CTS pin.
25/64
MK50H25
4.2 Initialization Block
MK50H25 initialization includes the reading of the Initialization Block in the off-chip memory to obtain the
operating parameters. The Initialization Block is defined below. Upon receiving an Init primitive, portions
of the Initialization block are read by the MK50H25. The remainder of the Initialization block will be read
as needed by the MK50H25.
Figure 8: Initialization
BASE ADDRESS
MODE
LOCAL STATION ADDRESS
IADR+02
REMOTE STATION ADDRESS
IADR+04
N1 - MAX FRAME LENGTH
HIGHER ADDR
IADR+00
IADR+06
N2 + SCALER
IADR+08
T1 TIMER
IADR+10
TP TIMER
IADR+12
T3 TIMER
IADR+14
RLEN - RDRA <23:16>
IADR+16
RDRA <15:00>
IADR+18
TLEN - TDRA <23:16>
IADR+20
TDRA <15:00>
IADR+22
XID/TEST TX DESCRIPTOR
IADR+24
XID/TEST RX DESCRIPTOR
IADR+32
STATUS BUFFER
ADDRESS
IADR+40
ERROR COUNTERS
IADR+44
THRU
IADR+57
26/64
MK50H25
4.2.1 Mode Register
The Mode Register allows alteration of the MK50H25’s operating parameters.
1
5
IADR + 00
BIT
15:11
NAME
MFS<4:0>
1
4
1
3
1
2
1
1
MFS
<4:0>
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
E
X
T
C
F
E
X
T
A
F
D
A
C
E
E
X
T
C
E
X
T
A
D
R
F
C
S
D
T
F
C
S
F
C
S
S
MFS<4:0>
1
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
1
0
2
4
9
18
5
11
22
12
25
19
7
15
31
30
EXTCF
09
EXTAF
08
DACE
07
EXTC
06
EXTA
05
DRFCS
0
1
0
0
LBACK
<2:0>
DESCRIPTION
Minimum Frame Spacing defines the minimum number of flag
sequences transmitted between adjacent frames transmitted by the
MK50H25. This only affects frames transmitted by the MK50H25
and does not restrict the spacing of the frames received by the
MK50H25. When using RTS/CTS control this field defines the
number of flags transmitted at the beginning of the frame after
CTS is driven low (minus one for the trailing flag). See the following
table for encoding of this field.
NUMBER OF FLAGS
10
0
2
NUMBER OF FLAGS
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
MFS<4:0>
28
24
17
3
6
13
27
23
14
29
26
21
10
20
8
16
Extended Control Force. If set along with EXTC, the receiver will assume
the control field to be two octets long regardless of the first two bits of
the control field. See EXTC below.
Extended Address Force. If set along with EXTA, the receiver will
assume the address to be two otets long regardless of the first bit of
the address. See EXTA below.
Address and control field extraction are disabled when DACE is set
Address and control fields are treated as data and placed in memory
as such. DACE must be written with ”1” for normal transparent data
transfer operation, but can be set to ”0” for doing address and control
field filtering.
Extended Control Field filtering is enabled when EXTC = 1 if DACE = 0
and PROM = 0 (PROM is in CSR2).
Extended Address Field filtering is enabled when EXTA = 1 if DACE = 0
and PROM = 0 (PROM is in CSR2).
Disable Receiver FCS (CRC). When DRFCS = 0, the receiver will extract
and check the FCS field at the end of each frame. When DRFCS = 1,
the receiver continues to extract the last 16 or 32 bits of each frame,
27/64
MK50H25
04
DTFCS
03
FCSS
02:00
LBACK
depending on FCSS, but no check is performed to determine
whether the FCS is correct. If the received frame has no FCS, then the
FCSEN bit (in IADR+16) should be set so that MCNT will reflect the
correct length of the received frame.
Disable Transmitter FCS. When DTFCS=0, the transmitter will generate
and append the FCS to each signal unit. When DTFCS = 1, the FCS
logic is disabled, and no FCS is generated with transmitted frames.
Setting DTFCS = 1 is useful in loopback testing for checking the ability
of the receiver to detect an incorrect FCS.
FCS Select. When FCSS = 1, a 16-bit FCS is selected otherwise a 32bit FCS is used.
Loopback Control puts MK50H25 into one of several loopback
configurations. (Note: If RTSEN (CSR5<04>) = 1, then RTS (pin 26)
must be connected to CTS (pin 30) for proper loopback operation.)
LBACK
DESCRIPTION
0
Normal operation. No loopback.
4
Simple loopback. Receive data and clock are driven internally
by transmit data and clock. Transmit clock must be supplied
externally
5
Clockless loopback. Receive data is driven internally by
transmit data. Transmit and receive clocks are driven by
SYSCLK divided by 8.
6
Silent loopback. Same as simple loopback with td pin forced to
all ones.
7
Silent clockless loopback. Combination of Silent and Clockless
loopbacks. Receive data is driven internally by transmit data,
transmit and receive clocks are driven by SYSCLK divided by
8. The TD pin is forced to all ones.
4.2.2 Station Addresses
The MK50H25 uses the values in Local and Remote Station Address fields of the Initialization Block for
filtering received frames and for the address field of transmitted frames. The MK50H25 transmits commands with the Remote Station Address in the frame address field, and it transmits responses with the
Local Station Address in the frame address field. The MK50H25 compares the received frame address to
the Local and Remote Station Address fields. If the received frame address matches the Local Station
Address field the MK50H25 will treat the received frame as a command. If the received frame address
matches the Remote Station Address field the MK50H25 will treat the received frame as a response. The
MK50H25 also supports the reception of frames with a global address of all 1’s, if the XIDE bit
(CSR2<08>) is set =1. In this case, it will treat a frame received with a global address as a comand,
whether or not it is an XID/TEST frame. The MK50H25 however, will transmit a frame with a global address if all 1’s have been placed in the appropriate Local/Remote Address fields prior to an Init primitive
(UPRIM=2, CSR1) being issued.
28/64
MK50H25
4.2.3 Station Address and Control Field Filtering
The Local and Remote frame addresses may be either one or two octets according to the EXTA control
bit described in the MODE register. If extended address mode filtering is selected, bit zero of the address field should be set to a zero if adherening to HDLC standards. If extended address filtering is not
selected, frame adresses should be located in the lower order byte of of their respective fields. The address filtering is a one octet compare if the extended address bit, EXTA is 0 (Mode register bit 06), or follows the HDLC rules for extended addressing if EXTA is 1. Frames not matching either address are ignored.
In the MK50H25, address filtering and control field handling applies only to octet aligned frames received
with good FCS. Any frame not meeting both of these conditions is discarded and the ”Bad Frames Received” error counter (located at IADR + 38 of the Initialization Block ) is incremented.
Extended control field filtering is also possible using the EXTC bit (Mode Register bit 07), as shown in
Table 2 and Table 3. If EXTC is 0 then the C-field is one octet for all frames. If however EXTC is set to
1, the MK50H25 will look to see if either of the two least significant bits of the C-field is 0. If so, the frame
is said to have an extended control field which is two octets. In addition, bits EXTAF and EXTCF (Mode
Register bit 09 & 10) are useful to force extended address and control. If EXTAF is set along with EXTA,
the receiver will assume the address field to be two bytes long regardless of the first bit of the address
field. If EXTCF is set along with EXTC, the receiver will assume the contol field to be two bytes long regardless of the first two bits of that field.
The following table shows the MK50H25 address filtering options and handling of the received Address
field.
Table 2: MK50H25 Address Filtering Options
EXTA
EXTAF
XIDE
PROM
DACE
ADDRESS FILTERING
0
X
0
0
1
1
1
0
0
X
0
X
0
0
1
1
0
X
1
X
0
0
0
X
0
1
0
X
0
0
0
X
0
1
0
1
0
1
0
0
Single octet filtering L&R (Local & Remote frame adresses)
No address filtering, all frames accepted
Single octet filtering L&R and global addresses
Not allowed
Double octet filtering L&R per HDLC rules
Double octet filtering L&R per HDLC rules
Double octet filtering L&R regardless of A-field LSB
Not allowed
NOTES:
1. PROM is defined in CSR2 bit 10. XIDE is defined in CSR2 bit 08.
2. DACE, EXTA, EXTAF, EXTC, and EXTCF are defined in the Mode register. X = Do not care.
3. DACE and PROM should be set =1 only in Transparent Mode operation.
In Transparent Mode, address filtering is supported if the PROM bit (CSR2, bit 10) is 0. In this case,
frames are accepted if the received Address field matches either the Send Frame Address or the Receive Frame Address as specified in the Initialization Block. The Send and Receive addresses may be
either one or two octets in length according to the EXTA control bit as described above. Frames not
matching either address are ignored. Bit RADR in the Receive Message Descriptor (RMD0 <09>)indicates which of the two programmable adresses the frame matched. If address filtering is not used, these
fields can just be written as zeroes.
For global adresses, the XIDE bit is valid in transparent mode, depending upon the settings of the other
bits in the Mode Register, as shown in Table 3 below. If bit XIDE (CSR2, bit 08) is set to 1, then all
frames with address ”11111111” are accepted.
The following table shows the MK50H25 address filtering options and the way in which it handles the received Address and Control fields in Transparent Mode.
29/64
MK50H25
Table 3: Address and Control Field Handling By The MK50H25 Receiver In Transparent Mode
DACE PROM EXTA EXTAF EXTC EXTCF
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
1
1
1
1
1
0
1
0
0
1
1
1
1
0
0
1
1
1
X
X
0
0
0
1
0
1
0
0
0
1
0
X
X
0
1
0
0
1
1
0
1
0
0
1
X
X
0
0
0
0
0
1
0
0
0
0
1
X
X
Address Field Handling
A filtered
A filtered
A or EA filtered
EA filtered
A or EA filtered
EA filtered
Not filtered, AA -> MEM1
Not filtered, AA ->MEM1
Not filtered, AA or EA -> MEM1
Not filtered, EA -> MEM1
Not filtered, AA or EA -> MEM1
First 2 octets always filtered
Total transparent mode
Control Field Handling
CC-> MEM1
CC or EC -> MEM1
CC -> MEM1
CC -> MEM1
CC or EC-> MEM1
EC -> MEM1
CC -> MEM2
CC or EC-> MEM2
CC-> MEM2
CC-> MEM2
EC-> MEM2
EC-> MEM1
All data after opening flag &
before FCS -> memory
NOTES:
1. MEM1 is the first location and MEM2 is the second location where received data is loaded. MEM1 and MEM2 are
each 16 bits wide.
2. C is the received, single octet, control field. CC ->MEMx means the single octet control field C is loaded into both
bytes of a 16 bit memory location. Similarly, A is a single octet address field, and AA ->MEMx means the single octet
address field A is loaded into both bytes of a 16 bit memory location.
3. EC is an extended control field (2 octets). If EXTC=1 and either of the 2 LSB’s of the control filed is 0, the control field
is considered extended, This determines whether CC or EC ->MEMx. However, when EXTCF is set to 1, the control
field is always extended
4. EA is an extended address field (2 octets). ”A or EA filtered” means that one octet of the A-field is filtered if the LSB =
1, or two octets are filtered if the LSB = 0. Similarly ”AA or EA -> MEM1” means that AA is loaded into memory if the
LSB = 0; else, EA is loaded. This conforms to HDLC rules for extended address. However, if EXTAF is set to 1, two
octets are filtered regardless of the LSB, and EA will be loaded into memory.
5. .PROM is defined in CSR2 bit 10.
6. DACE, EXTA, EXTAF, EXTC, and EXTCF are as defined in the Mode register. X = Do not care.
30/64
MK50H25
4.2.4 Timer/Counters
1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
IADR + 06
COUNTER N1
IADR + 08
COUNTER N2
SCALER
IADR + 10
TIMER T1
IADR + 12
TIMER T3
IADR + 14
TIMER TP
There are 5 independent counter-timers. The Host will write the value of these to the Initialization Block.
COUNTER
DESCRIPTION
N1
MAXIMUM FRAME LENGTH. This field must contain the t wo’s complement of one
less than the maximum allowable frame length, in bytes. Any frame that exceeds this
count will be discarded.
N2
MAXIMUM RETRANSMISSION COUNT. This field must contain the two’s complement
of one less than the maximum number of retransmissions that will be made following
the expiration of T1. If CSR2<14> bit EIBEN=1 then the MK50H25 will expect the value
for counter N2 to be located in the upper byte of IADR + 40.
SCALER TIMER PRESCALER. Timers T1, T3, and TP are scaled by this number. The prescaler is
incremented once every 32 system clock pulses. When it reaches the timers are incremented and the prescaler is reset. This field is interpreted as two’s complement of the
prescaler period. If CSR2<14> bit EIBEN=1 then the MK50H25 will use the entire 16-bit
value at IADR+08 as the prescaler value. This may be required to achieve long timer
values when operating a high SYSCLK speeds. Note: a prescale value of 1 gives the
smallest amount of scalling to the timers (64 clock pulses); zero gives the largest (8224
clock pulses if EIBEN=0, or 2,097,184 clock pulses if EIBEN=1).
T1
RETRANSMISSION TIMER. Link control frames will be retransmitted upon expiration of
the T1 timer if the appropriate response is not received. This field must contain the two’s
complement of the period of timer T1. The scaled value of T1 should be made large
enough to allow the remote station to receive the control frame and send its response.
T3/T203
LINK IDLE TIMER. The link idle timer determines the amount of link idle time necessary
to consider the link disconnected. If CSR2<12> bit T203E=1 it determines the amount of
link idle time or time without receiving a valid frame before it begins a RR/P=1 polling sequence to determine if the link is still connected. This field must contain the two’s complement of the period of T3 or T203. T3 is disabled if CSR5<04> RTSEN = 1 or if the
MK50H25 is in Transparent mode.
31/64
MK50H25
TP
32/64
TRANSMIT POLLING TIMER. This scaled timer determines the length of time between
polls of the Transmit Descriptor Ring to determine if there is a frame awaiting transmission (i.e. OWNA bit has been set plus other appropriate information placed in the current
Transmit Descriptor). Unless TDMD (see CSR0) is set, or a frame is received (in protocol mode) on the link, no attempt is made to transmit a frame in the Transmit Descriptor
Ring until TP expires. At TP expiration all frames available in the Transmit Descriptor
Ring will be sent. This field must contain the two’s complement of the period of timer
TP.
MK50H25
4.2.5 Receive Descriptor Ring Pointer
1
5
IADR + 16
R
I
N
T
D
1
4
1
3
1
2
RLEN
1
1
1
0
0
9
0
8
R
B
S
Y
R
B
F
C
S
F
C
S
E
R
F
C
S
E
N
IADR + 18
BIT
15
NAME
RINTD
14:12
RLEN
11
RBSY
10
RBFCS
09
FCSER
08
FCSEN
07:00/15:00
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
RDRA<23:16>
RDRA<15:00>
0
DESCRIPTION
RECEIVE INTERRUPT DISABLE. Setting this bit will cause no Receive
Interrupt (RINT) to be generated upon the reception of any frame.
RECEIVE RING LENGTH is the number of entries in the Receive
Ring expressed as a power of two.
Remote Busy indication enable. Setting this bit will enable the issuance
of Remote Busy Indication primitives (PPRIM=5) upon reception of
RNR or RR frame indicating a change in the busy status of the remote.
Receive frames with Bad FCS. Setting this bit causes the MK50H25 to
receive frames with bad FCS when in Transparent Mode. The FRMRR
bit in RMD0 will be set to indicate the received frame had a bad FCS.
This bit should be set only for Transparent Mode
FCSER. Setting this bit enables a separate Error Counter at IADR + 56
that will count aborted frames separately from Bad Frames Received.
Setting this bit will cause the MK50H25 to append the entire FCS of
received frames to the receive data buffer, and MCNT will reflect the
additional FCS bytes.
RECEIVE DESCRIPTOR RING ADDRESS is the base address
(lowest address) of the Receive Descriptor Ring. The Receive Descriptor Address must begin on a word boundary.
RDRA
4.2.6 Transmit Descriptor Ring Pointer
1
5
IADR + 20
IADR + 22
BIT
15
NAME
0
0
1
4
1
3
TLEN
1
2
1
1
0
1
0
0
9
0
8
0
7
TWD
0
6
0
5
0
4
0
3
0
2
0
1
0
0
TDRA<23:16>
TDRA<15:00>
0
DESCRIPTION
Reserved, must be written as a zero.
33/64
MK50H25
14:12
TLEN
11
10:08
0
TWD
07:00/15:00
TDRA
TRANSMIT RING LENGTH is the number of entries in the Transmit
Ring expressed as a power of two.
TLEN
NUMBER
OF
ENTRIES
TWD
0
1
2
3
4
5
6
7
1
2
4
8
16
32
64
128
0
1
2
3
4
5
6
7
WINDOW SIZE
EXTC = 0 EXTC = 1
NA
1
2
3
4
5
6
7
1
3
7
15
31
63
127
127
Reserved, must be written as a zero.
Transmit Window is the window size of the Transmitter expressed as a
power of two less one. TWD is the maximum number of I frames which
may be transmitted without an acknowledgement. TWD is not allowed
to be greater than 127. For Transparent Mode set TWD = 1 or more.
TRANSMIT DESCRIPTOR RING ADDRESS is the base address
(lowest address) of the Transmit Descriptor Ring. The Transmit Descriptor Ring Address must begin on a word boundary.
4.2.7 XID/TEST Descriptors
The XID/TEST Descriptors contain pointers to the buffers used to receive and transmit XID, and TEST
frames, as well as buffer lengths. The exact format of these descriptors can be seen in the following Receive and Transmit Message Descriptor Entry descriptions. They are used the same as other descriptors
except that no data chaining is allowed (i.e., SLF and ELF must be set to 1).
4.2.8 Status Buffer Address
1
5
IADR + 40
IADR + 42
BIT
15:08
07:00/15:00
34/64
NAME
0
SBA
1
4
1
3
1
2
1
1
0
0
0
9
0
8
0
7
N2
(If CSR2 EIBEN =1)
SBA<15:00>
0
6
0
5
0
4
0
3
0
2
0
1
0
0
SBA<23:16>
0
DESCRIPTION
Reserved, must be written as zeroes.
STATUS BUFFER ADDRESS points to a 7 word status
buffer into which status information is placed upon the issuance of the
Status Request primitive by the HOST. The status buffer must begin
on a word boundary.
MK50H25
4.2.9 Error Counters Seven locations in the Initialization buffer are reserved for use as error counters
which the MK50H25 will increment. These counters are intended for use by the host CPU for statistical
analysis. The MK50H25 will only increment the counters; it is up to the user to clear and preset them.
The error counters are:
Memory Address
Error Counter
IADR + 44
Bad Frames Received
- Bad FCS
- Non-Octet Aligned
IADR + 46
Number of FRMR frames received.
IADR + 48
Number of T1 timeouts.
IADR + 50
Number of REJ frames received.
IADR + 52
Number of REJ frames transmitted.
IADR + 54
Frames shorter than minimum length received.
IADR + 56
Number of Aborted frames received. Enabled only if FCSER = 1
IADR + 58 thru IADR + 60 Reserved. Must be programmed as zeroes only if EIBEN = 1.
4.3 Receive and Transmit Descriptor Rings
Each descriptor ring in memory is a 4 word entry. The following is the format of the receive and transmit
descriptors.
4.3.1 Receive Message Descriptor Entry
4.3.1.1 Receive Message Descriptor 0 (RMD0)
BIT
15
NAME
OWNA
14
OWNB
13
SLF
12
ELF
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
O
W
N
A
O
W
N
B
S
L
F
E
L
F
U
I
R
F
R
M
R
R
R
A
D
R
R
P
F
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
RBADR<23:16>
DESCRIPTION
When this bit is a zero either the HOST or the I/O ACCELERATION
PROCESSOR owns this descriptor. When this bit is a one the
MK50H25 owns this descriptor. The chip clears the OWNA bit after filling the buffer pointed to by the descriptor entry provided a valid
frame has been received. The Host sets the OWNA bit after emptying the buffer. Once the MK50H25, Host, or I/O acceleration
processor has relinquished ownership of a buffer, it may not change
any field in the four words that comprise the descriptor entry.
This bit determines whether the HOST or a Slave Processor or Process
owns the buffer when OWNA is a zero. The MK50H25 never uses
this bit.
Start of Long Frame indicates that this is the first buffer used by the
MK50H25 for this frame. It is used for data chaining buffers. SLF is
set by the MK50H25. NOTE: A ”Long Frame” is any frame which
needs chaining.
End of Long Frame indicates that this the last buffer used by MK50H25
for this frame. It is used for data chaining buffers. If both SLF and ELF
were set, the frame would fit into one buffer and no data chaining
would be required. ELF is set by the MK50H25.
35/64
MK50H25
11
10
UIR
FRMRR
UI Received indicates a UI frame has been received and is in this buffer.
FRMR Received indicates the I-field of a FRMR is stored in this buffer.
In Transparent mode with RBFCS=1 (IADR+16) it indicates received
frame referenced by this Message Descriptor has a bad FCS.
09
RADR
Valid only in Transparent Mode with address filtering enabled, RADR
indicates which of the 2 programmable addresses the frame matched.
If set, the received address field matched the value in the Local Address field of the Initialization Block. Otherwise it matched the value in
the Remote Address field.
08
RPF
Valid only for UI, XID, and TEST frames. RPF equals the state of the P
or F bit for the received frame.
07:00
RBADR
The High Order 8 address bits of the buffer pointed to by this descriptor.
This field is written by the Host and unchanged by MK50H25.
4.3.1.2 Receive Message Descriptor 1 (RMD1)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
RBADR<15:00>
BIT
15:01
NAME
RBADR
0
0
DESCRIPTION
The low order 16 address bits of the receive buffer pointed to by this
descriptor. RBADR is written by the Host CPU and unchanged by
MK50H25. The receive buffers must be word aligned.
4.3.1.3 Receive Message Descriptor 2 (RMD2)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
BCNT<15:00>
BIT
15:00
36/64
NAME
BCNT
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
DESCRIPTION
Buffer Byte Count is the length of the buffer pointed to by this
descriptor expressed in two’s complement. This field is written to by
the Host and unchanged by MK50H25. The value of BCNT must be
an even number.
MK50H25
4.3.1.4 Receive Message Descriptor 3 (RMD3)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
MCNT<15:00>
BIT
15:00
NAME
MCNT
DESCRIPTION
Message Byte Count is the length, in bytes, of the received frame
MCNT is valid only when ELF is set to a one. MCNT is written by
MK50H25 and read by the Host. If ELF is set to a zero the entire
buffer has been utilized and the message byte count is given in
BCNT above. The value of this field is expressed in two’s complement. MCNT also reflects additional FCS bytes if FCSEN = 1.
4.3.2 Transmit Message Descriptor Entry
4.3.2.1 Transmit Message Descriptor 0 (TMD0)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
O
W
N
A
O
W
N
B
S
L
F
E
L
F
T
U
I
T
I
N
T
D
0
X
P
F
BIT
15
NAME
OWNA
14
OWNB
13
SLF
12
ELF
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
TBADR<23:16>
DESCRIPTION
When this bit is a zero either the HOST or an I /O Acceleration Processor
owns this descriptor. When this bit is a one the MK50H25 owns this
descriptor. The host sets the OWNA bit after filling the buffer pointed
to by the descriptor entry. The MK50H25 releases the descriptor after
transmitting the buffer and receiving the proper acknowledgement
from the receiver. After the MK50H25, Host, or I/O Acceleration Processor has relinquished ownership of a buffer, it may not change any
field in the four words that comprise the descriptor entry.
This bit determines whether the HOST or an I /O Acceleration Processor
owns the buffer when OWNA is a zero. The MK50H25 never uses this
bit. This bit is provided to facilitate use of I/O Acceleration processors.
Start of Long Frame indicates that this is the first buffer used by the
MK50H25 for this frame. It is used for data chaining buffers. SLF is set
by the Host. When not chaining, SLF should be set to a one.
NOTE: A ”Long Frame” is any frame which needs data chaining.
End of Long Frame indicates that this is the last buffer used by the
MK50H25 for this frame. It is used for data chaining buffers. If both
SLF and ELF were set the frame would fit into one buffer and no
data chaining would be required. ELF is set by the Host. When not
chaining, ELF should be set to a one.
37/64
MK50H25
11
TUI
10
TINTD
09
08
0
XPF
07:00
TBADR
Transmit a UI frame indicates that a UI frame is to be transmitted from
the transmit buffer instead of a normal I frame. This bit must be set
for anything transmitted in Transparent Mode.
Transmit Interrupt Disable. If this bit is set, no transmit interrupt is
generated when ownership of this descriptor is released back to the
host.
Reserved, must be written as zeroes.
Transmit P/F bit instructs the MK50H25 to send the corresponding frame
with the respective value for the P/F bit. This bit is valid is valid only for
UI, XID and TEST frames and should be written zero otherwise.
The High Order 8 address bits of the buffer pointed to by this descriptor.
This field is written by the Host and unchanged by MK50H25.
4.3.2.2 Transmit Message Descriptor 1 (TMD1)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
TBADR<15:00>
BIT
15:00
NAME
TBADR
0
0
0
DESCRIPTION
The Low Order 16 address bits of the buffer pointed to by this descriptor.
TBADR is written by the Host and unchanged by MK50H25. The least
significant bit is zero since the descriptor must be word aligned.
4.3.2.3 Transmit Message Descriptor 2 (TMD2)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
BCNT<15:00>
BIT
15:00
38/64
NAME
BCNT
DESCRIPTION
Buffer Byte Count is the usable length of the buffer pointed to by this
descriptor expressed in two’s complement. This field is not used by
the MK50H25.
MK50H25
4.3.2.4 Transmit Message Descriptor 3 (TMD3)
1
5
1
4
1
3
1
2
1
1
1
0
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
MCNT<15:00>
BIT
15:00
NAME
MCNT
DESCRIPTION
Message byte count is the length, in octets, of the data contained in the
corresponding buffer. The value of this field is expressed in two’s complement.
4.3.3 Status Buffer
1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
SBA + 00
V(r)
V(s)
SBA + 02
Local State
Remote State
Phase
V(A)
Revision Indicator
CURRD <23:16>
SBA + 04
SBA + 06
SBA + 08
CURRD <15:00>
SBA + 10
Reserved
CURXD <23:16>
SBA + 12
CURXD <15:00>
39/64
MK50H25
MK50H25 STATUS BUFFER
FIELD
V(r)
V(s)
V(A)
LOCAL STATE
REMOTE STATE
PHASE
Revision Indicator
CURRD<23:0>
CURRXD<23:0>
DESCRIPTION
Current value of the Receive Count Variable. 0 < V(r) < 7
(0 < V(r) < 127 for extended control).
Current value of the Transmit Count Variable. 0 < V(s) < 7
(0 < V(s) < 127 for extended control).
Current value of Transmit Acknowledge Count. This field contains the
value of the N(r) of the most recently received S or I frame. The
modulo difference between V(A) and V(s) determines the number of
outstanding I frames that have not been acknowledged by the remote
station.
Indicates the current state of operation for the local (secondary) station.
0:
Normal Data Transfer State
1:
Local Busy State
2:
REJ Sent State
3:
DISC Sent State
4:
Normal Disconnected State
5:
SABM/E sent for link connection
6:
FRMR Sent State
7:
SABM/E sent for link reset
8:
Error Indication issued
Indicates the current state of operation for the remote station.
0:
Remote Not Busy
1:
Remote Busy
Indicates the current phase of operation for the local station.
-1:
Stopped, TD is held at 1’s, RD is ignored
0:
Information Transfer State
1:
Disconnected Phase, TD transmits flags
2:
Resetting Phase
3:
Transparent Data Transfer Phase
4:
MERR reset phase
Indicates Firmware Revision of the device. This closely corresponds
to the ”REV XXX” label branded on the package of the device.
Current Receive Descriptor. This pointer indicates the position of the
descriptor for the next receive buffer to be filled.
Current Transmit Descriptor. This pointer indicates the position of the
descriptor for the next transmit buffer to be transmitted.
4.4 Detailed Programming Procedures
4.4.1 Initialization (Reading of Initialization Block)
The following procedure should be followed to intialize the MK50H25:
1. Setup bus control information in CSR4.
2. Setup the Initialization Block and Desciptor Rings.
3. Load the address of the initialization block information into CSR’s 2 and 3.
4. Issue the INIT primitive through CSR1 (write 4200H to CSR1) instructing the MK50H25 to read the
initialization block pointed to by CSR’s 2 and 3.
5. Wait for the INIT confirmation primitive (CSR1 = 0242H) from the MK50H25.
Then clear the PAV bit in CSR1 (write 0040H to CSR1).
6. Issue the Start primitive through CSR1 (write 4300H to CSR1).
Flags will now be continously transmitted.
7. Enable interrupts in CSR0 if desired.
40/64
MK50H25
4.4.2 Active Link Setup
The following procedure should be followed to actively establish a link.
1. Issue Connect Request primitive (UPRIM=6) through CSR1. The MK50H25 will attempt to establish a
logical link. It does this by sending a SABM/P=1 frame, and repeats sending it at T1 timer intervals until a response is received or N2 have been sent (in which case it would issue PPRIM=14 with
PPARM=1).
2. Wait for a Connect Confirmation primitive (PPRIM=7) from the MK50H25 (indicating reception of UA
frame in response to SABM sent).
3. If a Connect Confirmation primitive is received, a link has been established.
4. If a Disconnect Indication primitive (PPRIM=14) is received, the MK5025 has been unable to establish
a link. The reason will be in the PPARM field of CSR1.
4.4.3 Passive Link Setup
The following procedure should be followed for passively establishing a link.
1. Issue a Disconnect Request primitive (UPRIM=14). If issued with UPARM=0, a DM/F=0 frame will be
sent; if issued with UPARM=1, a DISC/P=0 frame will be sent to the remote station requesting link
setup. This step is optional in many cases, but some networks require either a DM or DISC be sent to
initiate passive link setup.
2. Wait for a Connect Indication primitive (PPRIM=6) from the MK50H25.
3. If a Connect Indication primitive is received (indicating SABM frame has been received), issue a Connect Response primitive to indicate willingness to establish the link (causes MK50H25 to respond with
a UA frame). The link is now established.
4. If no Connect Indication primitive is received, the remote station is not trying to establish a link.
4.4.4 Refusing Link Setup
The following procedure should be followed when refusing link establishment.
1. A Connect Indication primitive received indicates a request by the remote station to establish a link.
2. Issue a Disconnect Request primitive to refuse to establish the link (causes MK50H25 to respond with
a DM or DISC frame depending on value of UPARM).
4.4.5 Sending Data
Use the following procedure to send a frame:
1. Wait for the OWNA bit of the current transmit descriptor to be cleared, if it is not already.
2. Fill the buffer associated with the current transmit descriptor with the data to be sent, or set the descriptor buffer address to any already filled buffer.
3. Repeat steps 1 & 2 for next buffer if chaining is necessary, setting SLF, ELF and MCNT appropriately.
4. Set the OWNA bit for each descriptor used.
5. Go on to next descriptor. The OWNA bits will be cleared when data has been sent successfully and
acknowledged. In Transparent Mode, OWNA bits are cleared immediately after frame transmission.
4.4.6 Receiving Data
The following procedure should be followed when receiving a frame:
1. Make sure the OWNA bit of the current receive descriptor is clear.
2. Read data out of the buffer associated with the current receive descriptor.
3. Set the OWNA bit of the current receive descriptor.
4. If the ELF bit of the current receive descriptor is clear, then go on to the next descriptor and repeat
the above steps appending data from each buffer until a descriptor with the ELF bit set is reached.
4.4.7 Link Disconnect
The following procedure should be followed to disconnect an established link.
1. Issue the Disconnect Request primitive to the MK50H25.
2. A Disconnect Confirmation primitive (PPRIM=15) will be issued after successful disconnection, and the
MK50H25 will go into Normal Disconnected state.
41/64
MK50H25
4.4.8 Link Reset
The following procedure should be followed to reset an established link.
1. Issue a Reset Request primitive (UPRIM=8).
2. Wait for a Reset Confirmation primitive (PPRIM=9) from the MK50H25 (indicating reception of UA
frame in response to SABM sent).
3. If a Reset Confirmation primitive is received, a link has been reset.
4. If a Disconnect Indication primitive (PPRIM=14) is received, the MK5025 was unable to reset the link.
The reason will be in the PPARM field of CSR1. Link connection procedures now must be performed
to re-establish the link.
4.4.9 Receiving Link Reset
The following procedure should be followed when receiving a request for link reset:
1. A Reset Indication primitive (PPRIM=8) will be received from the MK50H25 indicating the remote station has requested a resetting of the link.
2. If able to reset, issue a Reset Response primitive (UPRIM=9) to indicate willingness to reset the link.
3. If unable to reset, issue a Disconnect Request primitive (UPRIM=14) to disconnect the link.
4.4.10 Receiving FRMR Frame
The following procedure should be followed when receiving a FRMR frame:
1. An Error Indication primitive (PPRIM=4) will be received from the MK50H25 indicating an error condition. PPARM=2 will indicate a FRMR has been received. The I-field of the FRMR has been placed in
the receive buffer pointed to by the next available Receive Descriptor.
2. If able to reset the link, issue a Reset Response primitive (UPRIM=9) and wait for either a Reset Indication or a Disconnect Indication as described previously for Link Reset.
3. If unable to reset, issue a Disconnect Request primitive (UPRIM=14) to disconnect the link. Link connection procedures now must be performed to re-establish the link.
4.4.11 Exchanging Identification
The following procedure should be followed to exchange identification with the remote station:
1. The XIDE bit in CSR2 must be set prior to any identification exchange.
2. Place appropriate identification information in the XID/TEST Transmit buffer.
3. Issue an XID Request primitive (UPRIM=10)
4. If an XID Confirmation primitive (PPRIM=11) is received, the identification exchange has been performed, and the remote response is located in the XID/TEST Receive buffer.
4.4.12 Receiving XID/TEST Frames
The following procedure should be performed when receiving XID/TEST frames:
1. A XID Indication primitive (PPRIM=10) or TEST Indication Primitive (PPRIM=12) will be received from
the MK50H25 to indicate the reception of a XID or TEST frame. The information field of the received
XID or TEST frame will be located in the XID/TEST receive buffer.
2. To respond, place the appropriate information in the XID/TEST transmit buffer and issue a XID/TEST
Response Primitive (UPRIM=11/13).
3. To refuse, issue a Disconnect Request primitive (UPRIM=14).
NOTE: A XID or TEST Indication primitive will only be issued if the XIDE bit is set in CSR2. Otherwise all
XID/TEST frames will automatically be refused and not recognized.
4.4.13 Disabling the MK50H25
The following procedure should be followed to disable the MK50H25:
1. Issue the STOP primitive through CSR1. This will disable the MK50H25 from receiving or transmitting.
The TD pin will be held high while the MK50H25 is in the Stopped mode. The STOP bit in CSR0 will
be set and interrupts will be disabled. If reception or transmission of a frame is in progress, then received data may be lost, and the transmitted frame will be aborted.
4.4.14 Re-enabling the MK50H25
The same procedure should be followed for re-enabling the MK50H25 as was used to initalize upon
power up. If the Initialization Block and the hardware configuration have not changed, then steps 1,2,3,
4 and 5 of the intialization sequence may be omitted.
42/64
MK50H25
4.4.15 MK50H25 Internal Self Test
The MK50H25 contains an easy to use internal self test designed to test, with a high fault coverage, all
of the major blocks of the device except the DMA controller. It is suggested that a loopback test also be
performed to more completely test the DMA controller.
The following procedure should be followed to execute the internal self test:
1. Reset the device using the RESET pin.
2. Set bit 04 of CSR4.
3. Issue a Self Test Request (UPRIM=5) through CSR1.
4. Poll CSR1, waiting for the PAV bit in CSR1 to be set by the MK50H25.
5. After the PAV bit is set, read CSR1. If bit 04 is clear, the self test passed. If bit 04 is set, it failed. The
success or failure of the test is futher indicated in the PPRIM field as follows:
PPRIM
RESULT
0
Passed self test.
1
Failed the reset test of the self test.
2
Failed the self test in the micro controller RAM.
3
Failed the self test in the ALU.
4
Failed the self test in the timers.
5
Failed the self test in the transmitter and/or receiver.
6
Failed the self test in the CSR’s and/or bus master.
Otherwise
Failed device.
6. If the PAV bit is not set within 75 msec (SYSCLK = 10MHZ), then the MK50H25 is unable to respond
to the Self Test Request and will not complete successfully.
If the self test passes, then after clearing the PAV bit it may be immediately reexecuted from step 3, otherwise re-execution should proceed from step 1.
After executing Self-Test, the MK50H25 should be reset before continuing with other testing or operation
of the device. This is recommended because the Self-Test leaves some of the timers and registers in
different states than after reset. To not reset the device after Self-Test may cause unexpected results in
further operation of the device.
USER NOTES:
43/64
MK50H25
SECTION 5
ELECTRICAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
T UB
Temperature Under Bias
Tstg
Storage Temperature
VG
Voltage on any pin with respect to ground
Ptot
Power Dissipation
Value
Unit
-25 to +100
°C
-65 to +150
°C
-0.5 to VCC+0.5
V
0.5
W
Stresses above those listed under ”Absolute Maximum Rating” may cause permanent damage to the above device.
This is a stress rating only and functional operation of the device at these or any other condition above those indicated
in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
DC CHARACTERISTICS
TA=0 °C to 70 °C, VCC = +5 V ±5 percent unless otherwise specified.
Symbol
Max.
Units
VIL
Parameter
-0.5
+0.8
V
VIH
+2.0
VCC +0.5
V
+0.5
V
+10
mA
VOL
@ IOL = 3.2 mA
VOH
@ IOH= -0.4 mA
Min.
Typ.
+2.4
IIL
@ VIN = 0.4 to VCC
ICC
@ TSCT = 100 ns
V
µA
50
CAPACITANCE
f = 1MHz
Symbol
CIN
COUT
C IO
Parameter
Min.
Typ.
Max.
Units
Capacitance on Input pins
10
pF
Capacitance on Output Pins
10
pF
Capacitance on I/O pins
20
pF
AC TIMING SPECIFICATIONS
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
MK50H25
Parameter
Test Condition
-16
-25
-33
-16/25/33
No
Signal
Symbol
Min.
Min.
Min.
Max.
1
SYSCLK
TSCT
SYSCLK period
60
40
30
10000
2
SYSCLK
TSCL
SYSCLK low time
24
16
12
ns
3
SYSCLK
TSCH
SYSCLK high time
24
16
12
ns
4
SYSCLK
TSCR
Rise time of SYSCLK
0
0
0
8
ns
5
SYSCLK
TSCF
Fall time of SYSCLK
0
0
0
8
ns
6
TCLK
TTCT
TCLK period
20
20
20
ns
7
TCLK
TTCL
TCLK low time
8
8
8
ns
8
TCLK
TTCH
TCLK high time
9
TCLK
TTCR
Rise time of TCLK
10
TCLK
TTCF
Fall time of TCLK
11
TD
TTDP
TD data propagation
delay after the falling
edge of TCLK
12
TD
TTDH
TD data hold time after
the falling edge of TCLK
CL = 50 pF
Units
ns
8
8
8
0
0
0
8
ns
0
0
0
8
ns
13
ns
CL = 50 pF
5
5
5
ns
ns
44/64
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -16
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
No
Signal
Symbol
13
RCLK
TRCT
RCLK period
20
ns
14
RCLK
TRCH
RCLK high time
8
ns
15
RCLK
TRCL
RCLK low time
8
16
RCLK
TRCR
Rise time of RCLK
0
8
ns
17
RCLK
TRCF
Fall time of RCLK
0
8
ns
18
RD
TRDR
RD data rise time
0
8
ns
19
RD
TRDF
RD data fall time
0
8
20
RD
TRDH
RD hold time after rising edge of RCLK
2
ns
21
RD
TRDS
RD setup time prior to rising edge of
RCLK
8
ns
22 ALE/DAS
TDOFF
Bus Master driver disable
Output Delay
0
40
ns
23 ALE/DAS
TDON
Bus Master driver enable after rising
edge T1 SYSCLK
Output Delay
0
40
ns
24
THHA
Delay to falling edge of HLDA from
falling edge of HOLD (Bus Master)
HLDA
Parameter
Notes
MK50H25 -16
Min.
Typ.
Max.
Units
ns
0
ns
ns
25
HLDA
THLAH
HLDA input setup time
20
ns
26
HLDA
THLAS
Delay to rising edge HLDA from rising
edge HOLD
20
ns
27
A
TXAS
Address setup time
Output Delay
30
ns
28
A
TXAH
Address hold time
Output Delay
25
ns
29
DAL
TAS
Address setup time
Output Delay
35
ns
30
DAL
TAH
Address hold time
Output Delay
31
DAL
TRDAS
Data setup time (Bus Master read)
20
ns
32
DAL
TRDAH
Data hold time (Bus Master read)
10
ns
33
DAL
TWAH
Address hold time (Bus Master write)
Output Delay
15
34
DAL
TWDS
Data setup time (Bus Master write)
Output Delay
25
ns
35
DAL
TWDH
Data hold time (Bus Master write)
Output Delay
25
ns
36
DAL
TSRDS
Data setup time (Bus Slave read)
25
ns
37
DAL
TSRDH
Data hold time (Bus slave read)
25
ns
38
DAL
TSWDH
Data hold time (Bus slave write)
10
39
DAL
TSWDS
Data setup time (Bus slave write)
10
40
ALE
TALES
ALE setup time
Output Delay
30
ns
41
ALE
TALHB
ALE hold time (asserted to deasserted) (DMA Burst)
Output Delay
20
ns
42
ALE
TALHS
ALE hold time (asserted to 3-State)
(Single DMA cycle)
Output Delay
20
ns
43
DAS
TDASS
DAS setup time from falling edge of T2
SYSCLK (Bus Master)
Output Delay
25
ns
44
DAS
TDASH
DAS hold time from rising edge of
SYSCLK (Bus Master)
Output Delay
15
ns
TBMDE
Bus Master driver enable (from 3State to driven) (Bus Master)
Output Delay
25
ns
45 DALI/DALO
BM)/BM1
46
DALI
TRIS
DALI setup time (Bus Master read)
Output Delay
47
DALI
TRIH
DALI hold time (Bus Master read)
Output Delay
48
DALI
TBMDD
Bus Master driver disable (from driven
to 3-State) (Bus Master)
Output Delay
45/64
0
5
5
25
ns
ns
ns
ns
15
ns
25
ns
20
ns
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -16
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
Parameter
Notes
MK50H25 -16
No
Signal
Symbol
49
DALO
TROS
DALO setup time (Bus Master read)
Output Delay
Min.
50
DALO
TROH
DALO hold time (Bus Master read)
Output Delay
52
CS
TCSH
CS hold time
10
ns
53
CS
TCSS
CS setup time
10
ns
54
ADR
TSAH
ADR hold time
10
ns
55
ADR
TSAS
ADR setup time
10
ns
56
DAS
TSDAS
DAS input setup time (Bus slave)
10
ns
57
DAS
TSDSH
DAS input hold time (Bus slave)
10
ns
58
READY
TRDYS
READY setup time (Bus slave)
59
READY
TSRYH
READY hold time after rising edge of
DAS (Bus slave read)
60
READY
TRSH
READY setup time (Bus Master)
20
61
READY
TSRS
READY hold time (Bus Master)
12
ns
62
READ
TREDS
READ setup time (Bus slave)
10
ns
63
READ
TREDH
READ hold time (Bus slave)
10
ns
64
HOLD
THLDS
HOLD setup time (Bus Master)
Output Delay
20
ns
65
HOLD
THLDH
HOLD hold time (Bus Master)
Output Delay
40
ns
Output Delay
Typ.
Max.
Units
30
ns
30
ns
15
ns
20
ns
ns
46/64
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -25
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
No
Signal
Symbol
13
RCLK
TRCT
RCLK period
20
ns
14
RCLK
TRCH
RCLK high time
8
ns
15
RCLK
TRCL
RCLK low time
8
16
RCLK
TRCR
Rise time of RCLK
0
8
ns
17
RCLK
TRCF
Fall time of RCLK
0
8
ns
18
RD
TRDR
RD data rise time
0
8
ns
19
RD
TRDF
RD data fall time
0
8
20
RD
TRDH
RD hold time after rising edge of RCLK
2
ns
21
RD
TRDS
RD setup time prior to rising edge of
RCLK
8
ns
22 ALE/DAS
TDOFF
Bus Master driver disable
Output Delay
0
20
ns
23 ALE/DAS
TDON
Bus Master driver enable after rising
edge T1 SYSCLK
Output Delay
0
20
ns
24
THHA
Delay to falling edge of HLDA from
falling edge of HOLD (Bus Master)
HLDA
Parameter
Notes
MK50H25 -25
Min.
Typ.
Max.
Units
ns
0
ns
ns
25
HLDA
THLAH
HLDA input setup time
10
ns
26
HLDA
THLAS
Delay to rising edge HLDA from rising
edge HOLD
10
ns
27
A
TXAS
Address setup time
Output Delay
30
ns
28
A
TXAH
Address hold time
Output Delay
20
ns
29
DAL
TAS
Address setup time
Output Delay
35
ns
30
DAL
TAH
Address hold time
Output Delay
31
DAL
TRDAS
Data setup time (Bus Master read)
15
ns
32
DAL
TRDAH
Data hold time (Bus Master read)
10
ns
33
DAL
TWAH
Address hold time (Bus Master write)
Output Delay
15
34
DAL
TWDS
Data setup time (Bus Master write)
Output Delay
25
ns
35
DAL
TWDH
Data hold time (Bus Master write)
Output Delay
25
ns
36
DAL
TSRDS
Data setup time (Bus Slave read)
25
ns
37
DAL
TSRDH
Data hold time (Bus slave read)
25
ns
38
DAL
TSWDH
Data hold time (Bus slave write)
10
39
DAL
TSWDS
Data setup time (Bus slave write)
10
40
ALE
TALES
ALE setup time
Output Delay
30
ns
41
ALE
TALHB
ALE hold time (asserted to deasserted) (DMA Burst)
Output Delay
15
ns
42
ALE
TALHS
ALE hold time (asserted to 3-State)
(Single DMA cycle)
Output Delay
20
ns
43
DAS
TDASS
DAS setup time from falling edge of T2
SYSCLK (Bus Master)
Output Delay
25
ns
44
DAS
TDASH
DAS hold time from rising edge of
SYSCLK (Bus Master)
Output Delay
15
ns
TBMDE
Bus Master driver enable (from 3State to driven) (Bus Master)
Output Delay
25
ns
45 DALI/DALO
BM)/BM1
0
5
20
ns
ns
ns
ns
46
DALI
TRIS
DALI setup time (Bus Master read)
Output Delay
15
ns
47
DALI
TRIH
DALI hold time (Bus Master read)
Output Delay
25
ns
48
DALI
TBMDD
Bus Master driver disable (from driven
to 3-State) (Bus Master)
Output Delay
20
ns
47/64
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -25
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
Parameter
Notes
MK50H25 -25
No
Signal
Symbol
49
DALO
TROS
DALO setup time (Bus Master read)
Output Delay
Min.
50
DALO
TROH
DALO hold time (Bus Master read)
Output Delay
52
CS
TCSH
CS hold time
10
ns
53
CS
TCSS
CS setup time
10
ns
54
ADR
TSAH
ADR hold time
10
ns
55
ADR
TSAS
ADR setup time
10
ns
56
DAS
TSDAS
DAS input setup time (Bus slave)
10
ns
57
DAS
TSDSH
DAS input hold time (Bus slave)
10
ns
58
READY
TRDYS
READY setup time (Bus slave)
59
READY
TSRYH
READY hold time after rising edge of
DAS (Bus slave read)
60
READY
TRSH
READY setup time (Bus Master)
18
61
READY
TSRS
READY hold time (Bus Master)
10
ns
62
READ
TREDS
READ setup time (Bus slave)
10
ns
63
READ
TREDH
READ hold time (Bus slave)
10
ns
64
HOLD
THLDS
HOLD setup time (Bus Master)
Output Delay
15
ns
65
HOLD
THLDH
HOLD hold time (Bus Master)
Output Delay
35
ns
Output Delay
Typ.
Max.
Units
30
ns
30
ns
15
ns
15
ns
ns
48/64
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -33
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
No
Signal
Symbol
13
RCLK
TRCT
RCLK period
20
ns
14
RCLK
TRCH
RCLK high time
8
ns
15
RCLK
TRCL
RCLK low time
8
16
RCLK
TRCR
Rise time of RCLK
0
8
ns
17
RCLK
TRCF
Fall time of RCLK
0
8
ns
18
RD
TRDR
RD data rise time
0
8
ns
19
RD
TRDF
RD data fall time
0
8
20
RD
TRDH
RD hold time after rising edge of RCLK
2
ns
21
RD
TRDS
RD setup time prior to rising edge of
RCLK
8
ns
22 ALE/DAS
TDOFF
Bus Master driver disable
Output Delay
0
20
ns
23 ALE/DAS
TDON
Bus Master driver enable after rising
edge T1 SYSCLK
Output Delay
0
20
ns
24
THHA
Delay to falling edge of HLDA from
falling edge of HOLD (Bus Master)
HLDA
Parameter
Notes
MK50H25 -33
Min.
Typ.
Max.
Units
ns
0
ns
ns
25
HLDA
THLAH
HLDA input setup time
10
ns
26
HLDA
THLAS
Delay to rising edge HLDA from rising
edge HOLD
10
ns
27
A
TXAS
Address setup time
Output Delay
25
ns
28
A
TXAH
Address hold time
Output Delay
20
ns
29
DAL
TAS
Address setup time
Output Delay
30
ns
30
DAL
TAH
Address hold time
Output Delay
31
DAL
TRDAS
Data setup time (Bus Master read)
13
ns
32
DAL
TRDAH
Data hold time (Bus Master read)
8
ns
33
DAL
TWAH
Address hold time (Bus Master write)
Output Delay
15
34
DAL
TWDS
Data setup time (Bus Master write)
Output Delay
25
ns
35
DAL
TWDH
Data hold time (Bus Master write)
Output Delay
25
ns
36
DAL
TSRDS
Data setup time (Bus Slave read)
25
ns
37
DAL
TSRDH
Data hold time (Bus slave read)
25
ns
38
DAL
TSWDH
Data hold time (Bus slave write)
10
39
DAL
TSWDS
Data setup time (Bus slave write)
10
40
ALE
TALES
ALE setup time
Output Delay
25
ns
41
ALE
TALHB
ALE hold time (asserted to deasserted) (DMA Burst)
Output Delay
15
ns
42
ALE
TALHS
ALE hold time (asserted to 3-State)
(Single DMA cycle)
Output Delay
20
ns
43
DAS
TDASS
DAS setup time from falling edge of T2
SYSCLK (Bus Master)
Output Delay
20
ns
44
DAS
TDASH
DAS hold time from rising edge of
SYSCLK (Bus Master)
Output Delay
15
ns
TBMDE
Bus Master driver enable (from 3State to driven) (Bus Master)
Output Delay
20
ns
45 DALI/DALO
BM)/BM1
0
5
20
ns
ns
ns
ns
46
DALI
TRIS
DALI setup time (Bus Master read)
Output Delay
15
ns
47
DALI
TRIH
DALI hold time (Bus Master read)
Output Delay
20
ns
48
DALI
TBMDD
Bus Master driver disable (from driven
to 3-State) (Bus Master)
Output Delay
20
ns
49/64
MK50H25
AC TIMING SPECIFICATIONS (Continued) - MK50H25 -33
TA = 0 °C to 70 °C, VCC = +5 V ±5 percent, unless otherwise specified.
Parameter
Notes
MK50H25 -33
No
Signal
Symbol
49
DALO
TROS
DALO setup time (Bus Master read)
Output Delay
Min.
50
DALO
TROH
DALO hold time (Bus Master read)
Output Delay
52
CS
TCSH
CS hold time
10
ns
53
CS
TCSS
CS setup time
10
ns
54
ADR
TSAH
ADR hold time
10
ns
55
ADR
TSAS
ADR setup time
10
ns
56
DAS
TSDAS
DAS input setup time (Bus slave)
10
ns
57
DAS
TSDSH
DAS input hold time (Bus slave)
10
ns
58
READY
TRDYS
READY setup time (Bus slave)
59
READY
TSRYH
READY hold time after rising edge of
DAS (Bus slave read)
60
READY
TRSH
READY setup time (Bus Master)
15
61
READY
TSRS
READY hold time (Bus Master)
10
ns
62
READ
TREDS
READ setup time (Bus slave)
10
ns
63
READ
TREDH
READ hold time (Bus slave)
10
ns
64
HOLD
THLDS
HOLD setup time (Bus Master)
Output Delay
15
ns
65
HOLD
THLDH
HOLD hold time (Bus Master)
Output Delay
30
ns
Output Delay
Typ.
Max.
Units
25
ns
25
ns
15
ns
15
ns
ns
50/64
MK50H25
Figure 5a: TTL Output Load Diagram
Figure 5b: Open Drain Output Load Diagram
TEST
POINT
Vcc
Vcc
R1 = 1.2K
FROM
OUTPUT
UNDER
TEST
R1 = 1.4K
FROM
OUTPUT
UNDER
TEST
CR1 - CR4 = 1N914 or EQUIV
CR 1
C
CR
0.4 mA
2
L
C
CR 3
L
C L = 50pF min @ 1 MHz
CR 4
NOTE: This load is used on open
NOTE: This load is used on all outputs except INTR, HOLD, READY.
drain outputs INTR, HOLD, READY.
Figure 6: MK50H25 Serial Link Timing Diagram
13
14
15
RCLK
16
21
19
17
20
RD
18
6
8
7
TCLK
10
9
11
12
TD
TIMING MEASUREMENTS ARE MADE AT THE FOLLOWING VOLTAGES,
UNLESS OTHERWISE SPECIFIED:
”1”
51/64
”0”
OUTPUT
2.0 V
O.8 V
INPUT
2.0 V
O.8 V
FLOAT
10 %
90 %
MK50H25
Figure 7: MK50H25 BUS Master Timing (Read) (for CYCLE = 0, CSR2<15>)
T0
T1
T2
T3
T4
T5
T6
SYSCLK
65
64
HOLD
24
26
25
HLDA
28
27
A 16-23
ADDRESS
40
23
41
ALE
43
23
42
44
DAS
22
60
61
READY
29
30
DAL0-15
ADDR
31
32
DATA IN
48
50
49
DALO
45
46
47
DALI
READ
48
BM0,1
NOTES:
1. The shaded SYSCLK periods T0 and T5 will be removed when setting CSR2 bit 15,
CYCLE =1 to select the shorter DMA cycle as shown in Figure 7a.
2. Output delay times are the maximum delay from the specifed edge to a valid output.
3. The Bus Master cycle time will increase from a minimum, in 1 SYSCLK increments
until the slave device returns READY.
52/64
MK50H25
Figure 7a: MK50H25 Reduced Cycle BUS Master Timing (Read) (for CYCLE = 1, CSR2<15>)
T1
T2
T3
T4
T5
SYSCLK
65
64
HOLD
24
26
25
HLDA
28
27
A 16-23
ADDRESS
40
23
41
ALE
42
43
23
44
DAS
22
60
61
READY
29
31
30
DAL0-15
ADDR
32
DATA IN
50
48
49
DALO
45
46
47
DALI
READ
48
BM0,1
NOTES:
1. This reduced DMA Cycle Time is selected by setting CSR2 bit 15, CYCLE =1.
2. Output delay times are the maximum delay from the specifed edge to a valid output.
3. The Bus Master cycle time will increase from a minimum, in 1 SYSCLK increments
until the slave device returns READY.
53/64
MK50H25
Figure 8: MK50H25 BUS Master Timing Diagram (Write) (for CYCLE = 0, CSR2<15>)
T0
T1
T2
T3
T4
T5
T6
SYSCLK
65
64
HOLD
24
26
25
HLDA
28
27
A 16-23
ADDRESS
40
23
41
ALE
43
23
42
44
DAS
22
60
61
READY
29
35
34
DAL0-15
ADDR
DATA
33
48
DALO
45
DALI
READ
48
BM0,1
NOTES:
1. The shaded SYSCLK periods T0 and T5 will be removed when setting CSR2 bit 15,
CYCLE =1 to select the shorter DMA cycle as shown in Figure 8a.
2. Output delay times are the maximum delay from the specifed edge to a valid output.
3. The Bus Master cycle time will increase from a minimum, in 1 SYSCLK increments
until the slave device returns READY.
54/64
MK50H25
Figure 8a: MK50H25 Reduced Cycle BUS Master Timing (Write) (for CYCLE = 1, CSR2<15>)
T1
T2
T3
T4
T5
SYSCLK
65
64
HOLD
24
26
25
HLDA
28
27
A 16-23
ADDRESS
40
23
41
ALE
42
43
23
44
DAS
22
60
61
READY
29
DAL0-15
35
34
ADDR
DATA
33
48
DALO
45
DALI
READ
48
BM0,1
NOTES:
1. This Reduced DMA Cycle Time is selected by setting CSR2 bit 15, CYCLE = 1.
Times T0 and T5 from the standard DMA Cycle are removed for this reduced timing.
2. Output delay times are the maximum delay from the specifed edge to a valid output.
3. The Bus Master cycle time will increase from a minimum, in 1 SYSCLK increments
until the slave device returns READY.
55/64
MK50H25
Figure 8b: BUS Master BURST Timing (Reduced Cycle - Write)
T1
T2
T3
T4
T5
T1
T2
T3
T4
T5
SYSCLK
65
64
HOLD
24
26
25
HLDA
27
27
A 16-23
28
ADDRESS
ADDRESS
40
23
40
41
41
ALE
43
23
43
44
42
44
DAS
60
60
61
22
61
READY
29
DAL0-15
ADDR
34
29
34
DATA
ADDR
35
DATA
33
48
DALO
45
DALI
READ
48
BM0,1
56/64
MK50H25
Figure 9: MK50H25 BUS Slave Timing Diagram (Read)
SYSCLK
53
52
55
54
CS
ADR
56
57
DAS
58
59
READY
62
63
READ
(Read)
36
DAL
0-15
37
DATA OUT
NOTES:
1. Input setup and hold times are in minimum values required to or from the
particular edge specified in order to be recognized in that cycle.
2. Output delay times are from the specified edge to a valid output.
57/64
MK50H25
Figure 10: MK50H25 BUS Slave Timing Diagram (Write)
SYSCLK
53
52
55
54
CS
ADR
56
57
DAS
58
59
READY
62
63
39
38
READ
(Write)
DAL0-15
DATA IN
NOTES:
1. Input setup and hold times are the minimum values required to or from the
particular edge specified in order to be recognized in that cycle.
2. Output delay times are from the specified edge to a valid output.
58/64
MK50H25
ORDERING INFORMATION
MK50H25 Q XX
SPEED SORT
16 = 16MHz SYSCLK
25 = 25MHz SYSCLK
33 = 33MHz SYSCLK
PACKAGE
N = Plastic DIP (48 Pins)
Q = Plastic J-Leaded Cip Carrier (52 Pins)
-84Q = 84 PLCC for use with external ROM
PART# PROTOCOL
50H25 = LAPB
59/64
MK50H25
DIP48 PACKAGE MECHANICAL DATA
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
a1
0.63
0.025
b
0.45
0.018
b1
0.23
b2
0.31
1.27
D
E
0.009
0.012
0.050
62.74
15.2
16.68
2.470
0.598
0.657
e
2.54
0.100
e3
58.42
2.300
F
MAX.
14.1
0.555
I
4.445
0.175
L
3.3
0.130
60/64
MK50H25
PLCC52 PACKAGE MECHANICAL DATA
DIM.
mm
MAX.
A
4.20
5.08
A1
0.51
A3
2.29
3.30
0.090
0.13
B
0.33
0.53
0.013
0.021
B1
0.66
0.81
0.026
0.032
MIN.
TYP.
MAX.
0.165
0.20
0.020
0.25
0.01
D
19.94
20.19
0.785
0.795
D1
19.05
19.20
0.750
0.756
D2
17.53
18.54
0.690
0.730
D3
15.24
0.60
E
19.94
20.19
0.785
0.795
E1
19.05
19.20
0.750
0.756
17.53
18.54
0.690
0.730
E2
61/64
inch
TYP.
C
MIN.
E3
15.24
0.60
e
1.27
0.05
L
0.64
0.025
L1
1.53
M
1.07
1.22
0.042
0.048
M1
1.07
1.42
0.042
0.056
0.060
MK50H25
PLCC84 PACKAGE MECHANICAL DATA
See following page for PLCC84 pin description
mm
DIM.
MIN.
inch
TYP.
MAX.
A
4.20
5.08
A1
0.51
A3
2.29
3.30
0.090
0.13
B
0.33
0.53
0.013
0.021
B1
0.66
0.81
0.026
0.032
C
MIN.
TYP.
MAX.
0.165
0.20
0.020
0.25
0.01
D
30.10
30.35
1.185
1.195
D1
29.21
29.41
1.150
1.158
D2
27.69
28.70
1.090
1.130
D3
25.40
1.00
E
30.10
30.35
1.185
1.195
E1
29.21
29.41
1.150
1.158
E2
27.69
28.70
1.090
1.130
E3
25.40
1.00
e
1.27
0.05
L
0.64
0.025
L1
1.53
0.060
M
1.07
1.22
0.042
0.048
M1
1.07
1.42
0.042
0.056
62/64
MK50H25
MK50H25 PLCC84 Pin Description
PIN
SIGNAL NAME
PIN
SIGNAL NAME
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Vss
EROMEN - External ROM Enable
DAL07
NC
DAL06
EROMD11
DAL05
DAL04
DAL03
EROMD10
DAL02
DAL01
DAL00
EROMD09
READ
EROMD08
INTR
DALI
DALO
NC
Vss
NC
EROMD07
DAS
EROMD06
BM0
EROMD05
BM1
HOLD
EROMD04
ALE
HLDA
EROMD03
CS
EROMD02
ADR
EROMD01
READY
EROMD00
RESET
Vcc
Vss
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
NC
TCLK
DTR
EROMA0
RCLK
EROMA1
SYSCLK
TD
EROMA2
DSR/CTS
RD
EROMA3
A23
EROMA4
A22
EROMA5
A21
NC
A20
NC
A19
Vss
A18
A17
EROMA6
A16
EROMA7
DAL15
DAL14
EROMA8
DAL13
DAL12
EROMA9
DAL11
EROMA10
DAL10
EROMA11
DAL09
EROMA12 (EITest)
DAL08
EROMAEN - Ext. ROM Address Enable
Vcc
63/64
MK50H25
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsibility for the
consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No
license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
SGS-THOMSON Microelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of SGS-THOMSON Microelectronics.
 1996 SGS-THOMSON Microelectronics All Rights Reserved
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands - Singapore Spain - Sweden - Switzerland - Taiwan - Thaliand - United Kingdom - U.S.A.
64/64
Similar pages