The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. Miniature Waterproof Shielded Connectors LF Series Mated dimensions (Example : LF07) 8.9 mm max. (3 pos.) Ø13 36.4 Receptacle Plug Short turn bayonet lock Mating: Insert the plug, and then turn the locking collar clockwise, as indicated by the coupling direction marking. ■Features 2 1. Ease of shielded termination and connector assembly All components are self-aligning and do not require complex assembly tooling. The shield of the cable is connected with the metal housing of the connector using simple shielding clamp, supplied with the connector. 1 Receptacle Locking collar Coupling direction marking Un-mating: Turn the locking collar counter-clockwise than pull off the plug. 1 2. Water and dust protected IP68 protection rating. Complete protection against dust penetration and against water penetration when mated assembly is submerged at the depth of 1.8 meter for 48 hours. Plug 2 Coupling direction marking 3. Bayonet lock Short turn bayonet lock assures secure vibration resistant mating of the connectors. 4. Acquired safety standard 4 pos. is 10A and meets safety standards (TÜV) Also 3- and 4-pos. have acquired the UL standard. Shielding Connection - Plug Built-in shield connection spring Cable shielding connection clamp Cable 5. High current rating capacity Number of contacts Current rating 3 5A max. 4 10A max. 6, 12 and 20 11 2A max. 10A max. 2A max. 2011.5 1 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors ■Product Specifications Voltage rating Rating Current rating Operating temperature range Storage temperature range Item 125V AC, 175V DC (3 pos.) 125V AC, 125V DC (4 pos.) 30V AC, 42V DC (6 pos. , 12pos. , 20pos.) 125V AC, DC (11 pos. A to D) 30V AC, 42V DC (11 pos. 1 to 7) 5A max. (3 pos.) 10A max. (4 pos.) 2A max. (6 pos. , 12pos. , 20pos.) 10A(11 pos. A to D), 2A(11 pos. 1 to 7) –25ç to +85ç (Note 1) –10ç to +60ç (Note 2) Specification Conditions 11.Contact resistance 15 mø max. (3, 6, 12, 20 pos.) 15 mø max. (4 pos.) 15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.) 12.Insulation resistance 1000 Mø min. 13.Withstanding voltage No flashover or insulation breakdown. 14.Vibration No electrical discontinuity for 10µs max. 15.Shock No electrical discontinuity for 10µs max. 16.Durability 16.(Mating/un-mating) 30 mø max. (3, 6, 12, 20 pos.) 10 mø max. (4 pos.) 10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.) 17.Temperature cycle Insulation resistance: 100 Mø min. 500V DC (3, 4 pos.) 100V DC (6, 12, 20 pos.) 500V DC (A to D), 100V DC (1 to 7)(11pos.) 1250V AC/one minute (3, 4 pos.) 300V AC/one minute (6, 12, 20 pos.) 1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.) Frequency: 10 to 55Hz, single amplitude of 0.75mm, acceleration of 98 m/s2 for 3 hours in 3 axis. Acceleration of 490m/s2, 11ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. Insulation resistance: 100 Mø min. (Dray state) 19.Water / dust protection When mated with corresponding connector. 1000 cycles Temperature: -55ç ➝ Room temperature ➝ +125ç ➝ Room temperature Time: 30 ➝ 2 to 3 ➝ 30 ➝ 2 to 3 (minutes) 5 cycles Insulation resistance: 110 Mø min. (When temperature high) 18.Humidity 1A DC 96 hours at temperature of 40ç and humidity of 90% to 95%. Complete dust protection. No water penetration when submerged for 48 hours at the depth of 1.8 meter. Note 1: Includes temperature rise caused by the current flow. Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature range and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation. ■Materials / Finish Components Material Finish / Color Remarks Body / back shell Zinc alloy Nickel plated –––––––––– Insulator PPS Black UL94V-0 Contacts Copper alloy Gold plated –––––––––– Gasket Chloroprene rubber Black –––––––––– ■Ordering Information Please determine the specific product. If listed needed, please select and order the product No. LF 07 - W B P * - 6 S 1 2 3 4 5 6 7 1 Series name 2 Shell size 3 Waterproof 4 Lock Mechanism 5 Connector type 6 Number of contacts 7 Contact type 2 : LF 07 10 13 W : Waterproof type B : Bayonet lock P : Plug R : Receptacle J : Jack (*:Form change zoning symbols in an identical class) : 3, 4, 6, 11, 12, 20 P : Male contact S : Female contact The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors (Cable dia.) ■Plugs ØA ØC B (Shown one example) Unit:mm Part number CL No. Contact LF07WBP-3S LF07WBP-3P LF07WBP-6S LF07WBP-6P LF10WBP-4S LF10WBP-4P LF10WBP-12S LF10WBP-12P LF13WBP-20S LF13WBP-20P LF13WBP-11S LF13WBP-11P 136-0003-7 136-0004-0 136-0001-1 136-0002-4 136-0005-2 136-0006-5 136-0007-8 136-0008-0 136-0009-3 136-0010-2 136-0011-5 136-0012-8 Female Male Female Male Female Male Female Male Female Male Female Male Number of contacts ØA B ØC Weight 12.3 35.8 5 11g 14.8 41.8 7.3 17g 17.9 51.9 8.7 29g 3 6 4 12 20 11 ■Plugs ØA B ØC(Cable dia.) ●Lock ease type Unit:mm Part number LF10WBPD-4S LF10WBPD-4P LF10WBPD-12S LF10WBPD-12P CL No. Contact 136-0014-3-00 136-0017-1-00 136-0015-6-00 136-0018-4-00 Male Female Male Female Number of contacts ØA ØB 16.8 41.8 ØC C Weight 4 7.3 19g 12 3 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors ■Receptacles C ØB ØA D E F(HEX) Unit:mm Part number CL No. Contact LF07WBR-3P LF07WBR-3S LF07WBR-6P LF07WBR-6S LF10WBR-4P LF10WBR-4S LF10WBR-12P LF10WBR-12S LF13WBR-20P LF13WBR-20S LF13WBR-11P LF13WBR-11S 136-1003-2 136-1004-5 136-1001-7 136-1002-0 136-1005-8 136-1006-0 136-1007-3 136-1008-6 136-1009-9 136-1010-8 136-1011-0 136-1012-3 Male Female Male Female Male Female Male Female Male Female Male Female Number of contacts ØA ØB 3 ØC C D E F Weight 7.65 1M9∞0.75 11 4g 7.75 M11∞0.75 13 7.75 M14∞0.75 17 16.55 10.3 13 12.8 15.3 6 4 15.05 15.25 19.05 12 6g 17.25 20 17.25 15.9 18.3 11 19.05 Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.) ■Receptacles ●Rear panel mount type · Solder Type C ØB ØA D E Unit:mm Part number LF10WBRB-4P LF10WBRB-12P LF10WBRB-12S 4 CL No. Contact Number of contacts 136-1118-4-00 136-1013-6-00 136-1014-9-00 Male Male Female 4 12 ØA ØB ØC C D E Weight 17 M14∞0.75 10g 19.05 12.8 18.3 17.25 5g 6g 9g 10g 9g 10g The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors ●Rear panel mount type · Through hole Type C ØB ØA D E Unit:mm Part number CL No. LF10WBRB-12PD 136-1015-1-00 LF10WBRB-12SD 136-1016-4-00 Contact Number of contacts ØA ØB ØC C D E Weight Male Female 12 12.8 18.3 17.5 17 M14∞0.75 10g ØD (Cable dia.) ■Jacks ØB ØA C (Shown one example) Unit:mm Part number CL No. Contact LF07WBJ-3P 136-2003-8 Male LF07WBJ-3S 136-2004-0 Female LF07WBJ-6P 136-2001-2 Male LF07WBJ-6S 136-2002-5 Female LF10WBJ-4P 136-2005-3 Male LF10WBJ-4S 136-2006-6 Female LF10WBJ-12P 136-2007-9 Male LF10WBJ-12S 136-2008-1 Female LF13WBJ-20P 136-2009-4 Male LF13WBJ-20S 136-2010-3 Female LF13WBJ-11P 136-2011-6 Male LF13WBJ-11S 136-2012-9 Female Number of contacts ØA ØB C ØD Weight 10.3 11.5 36.3 5.0 11g 12.8 13.8 42.4 7.3 16g 3 6 4 12 29g 20 15.9 11 16.9 52.4 8.7 30g 29g 30g 5 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors ■CAP ●For Receptacles ØA B Unit:mm Part number CL No. Applicable connector ØA B Weight 14.8 8.8 5g 17.9 8.75 7g LF10EBR-4P LF10WBR-4S LF10WBR-12P LF10WBR-12S LF10WBR-C 136-3001-8-00 LF10WBRB-4P LF10WBRB-12P LF10WBRB-12S LF10WBRB-12PD LF10WBRB-12SD LF13WBR-20P LF13WBR-C 136-3003-3-00 LF13WBR-20S LF13WBR-11P LF13WBR-11S 6 The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors ■Applicable tools Unit:mm Description Part number Manual cable clamp crimp CL No. LF series Applicable cable dia. HR10A-TC-02 150-0041-2 5 (Note) 150-0234-6 7.3 · 8.7 LF-TC-01 Note: Applicable cable dia. is only 5mm for LF series. ■Solder termination fixture (Shown one example) Part number CL No. LF07BP-T01 LF07BJ-T01 LF10BP-T01 LF10BJ-T01 LF13BP-T01 LF13BJ-T01 150-0232-0 150-0233-3 150-0235-9 150-0236-1 150-0237-4 150-0238-7 (Shown one example) Applicable connectors LF07WBP-6S,6P,3S,3P LF07WBJ-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF10WBJ-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF13WBJ-20S,20P,11S,11P unit (mm) 5 .0 +0 0 A ■Panel Cutout Alignment guide Shell size B +0.05 0 A B Panel thickness LF07WBR-ππ Ø9.05 8.1 0.7 to 2 LF10WBR-ππ Ø11.05 10.2 0.7 to 2 LF13WBR-ππ Ø14.05 13.1 0.7 to 2 LF10WBRB-ππ Ø14.05 13.1 0.7 to 2 ■Contact position arrangement and specifications Shell size LF07 LF10 LF13 Contact configuration 3 1 5 2 1 8 3 3 2 7 12 11 3 6 5 4 10 Number of contacts 3 6 4 12 Withstanding voltage 1250V AC 300V AC 1250V AC 300V AC Current rating 5A 2A 10A 2A Insulation resistance 1000Mø 1000Mø 1000Mø Contact resistance 15mø 5mø 15mø 1.7mm 0.8mm Solder pot inner diameter 1.15mm 0.8mm B 2 4 2 4 1 1 9 1 6 C A 2 D 2 1 5 3 6 4 7 11 4 AC1250V 4 10A 7 4 8 5 9 10 11 12 13 14 15 16 17 18 19 20 20 7 AC300V 7 2A 1000Mø 4 5mø 4 Ø1.7 6 3 7 15mø 7 Ø0.8 AC300V 2A 1000Mø 4mø 0.8mm Note 1: The contact configuration as viewed from the female contact connector mating side. Note 2: The ▼ symbol indicates polarizing key position. Note 3: Withstanding voltages are test voltage values. 7 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors ■Termination and Assembly Instructions The connectors are delivered with pre-assembed condition and the disassembly as shown No.1. 1 Operation Illustration No. Solder termination fixture 1 Plug Plug disassembly 1 Fixture Part No. Applicable connector LF07BP-T01 LF07WBP-6S,6P,3S,3P LF10BP-T01 LF10WBP-4S,4P,12S,12P LF13BP-T01 LF13WBP-20S,20P,11S,11P Locking collar Insertion direction 2 1 Body / insulator assembly 2 Backshell Solder termination fixture Jack Body / insulator assembly 1 1 2 Threaded section Tightening collar 8 Loosen the backshell turning it counterclockwise. Connector Assembly Backshell 1 Threaded section Insert the jack into the securely held solder termination fixture as shown. Fixture Part No. Applicable connector LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF10WBJ-4S,4P,12S,12P LF13BJ-T01 LF13WBJ-20S,20P,11S,11P Backshell 2 Loosen the backshell turning it counter clockwise and remove it from the body/ insulator assembly. Jack Disassembly Insertion direction 2 Insert the plug into securely held solder termination fixture as shown. Apply a coating of Loctite 7649 (Manufactured by Henckel Japan, Ltd,) primer to the threaded sections of the backshell and the tightening collar. Completely dry the coated surfaces. Notes (1) Drying time at room temperature is approximately 30 to 70 seconds. (2) Ensure sufficient ventilation of the area at time of drying. (3) Take necessary steps to protect the coated surfaces from contamination. The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors 2 Operation Illustration No. 2 2 Strain relief collar Backshell Tightening collar Thread the tightening collar, strain relief collar, seal bushing and the backshell over the cable as illustrated. Notes Threading the components may not be possible after the cable-end finishing process Cable Seal bushing Cable preparation end Stripping dimensions 3 A 1 Cable preparation Cable outer jacket 1 Shielding mesh Notes Table 1. Stripping Dimensions Number of Conductors 3 6 4 12 11 20 A mm 8 to 9 13 to 14 14 to 15 22 to 23 (No.A to D) 23 to 24 (No.1 to 7) 23 to 24 2 Shielding mesh Wires Strip the cable’s outer jacket to the dimensions illustrated in the table 1. (1) Exercise caution not to damage the shielding mesh. (2) Any damage to the cable’s outer jacket may affect the waterproof performance of the assembled connector. 2 Fold back the shielding mesh over the cable’s outer jacket assuring that it is uniform on its diameter. 3 Strip the wires to the dimensions illustrated in the Table 2. Cable outer jacket Shielding mesh (Folded back) 4 to 5mm Wires Cable outer jacket Stripping dimensions 3 Cable outer jacket B Wires Notes When stripping the wires exercise caution not to damage it’s insulation, folded over shielding mesh or cable’s outer jacket. It may cause deffects in insulation, conduction, and waterproof performance. Conductors Table 2. Stripping Dimensions Number of Conductors 3 6 4 12 11 20 B mm 2.5±0.5 2±0.5 3±0.5 2±0.5 3±0.5 (No.A to D) 2±0.5 (No.1 to 7) 2±0.5 9 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors Operation Illustration No. Soldering 4 1 Soldering conditions Soldering iron tip temperature: 350±10ç Soldering time: within 5 sec. Notes (1) Assure that the solder compound is sufficiently melted on the soldering iron tip. (2) When applying, make sure that the solder will flow correctly at all the contact surfaces between the conductor and the contact. 2 Cmm –1 2 Wire Insulator Contact Table 3 Heat shrink tubing Dimensions Number of Conductors Number of contacts C mm 6 1 to 6 1 to 9 10 to 12 1 to 5,16 to 20 6 to 15 1 to 4 5 to 7 4 4 6 4 6 6 4 12 Heat-shrink tubing 20 11 2 Insulator –2 Insulator Insulator wall Contact Contact Insulator wall Wire insulation – 1 6, 12, 20, 11(No.1〜7) Conductors (1) Place a heat-shrink tubing (inside diameter of 1.1 mm min.) over every other wire. Perform the soldering of the contact and the (2) conductor, with the wire’s insulation touching the contact as shown. After soldering, slide the heat shrink tubing (3) over the soldered joint and shrink it. The tubing should touch the insulator as shown. 2 – 2 3, 4, 11(No.A〜D) Conductors (1) Perform the soldering of the contact and the conductor, with the wire’s insulation touching the contact as illustrated. (2) When soldering, to maintain the insulation between adjacent contacts. Make sure that the wire’s insulation remains below the edge of the insulator’s wall 0.5 mm min., as illustrated. Wire insulation Solder 3 0.5 mm min. D Cable outer jacket 3 After the soldering, keep a distance of D between the contact end and the cable’s outer jacket as illustrated. Note Shielding mesh (Folded back) Table 4. Wire Dimensions Number of Conductors 3 6 4 12 11 20 10 D mm 6 to 7 10 to 11 13 to 14 18 to 19 The distance of D is required in order to assure correct assembly of the backshell. The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors Crimping of the Shielding Clamp 1 Solder termination fixture Body / insulator assembly 1 After completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture. Note Soldered joints 2 Cable outer jacket Exercise caution not to damage or deform the solder joints. 2 Cable outer jacket Wires Shielding mesh Copper tape 2 mm max. 5 Operation Illustration No. Note 5 to 6mm Copper tape After wrapping the copper tape, the tape should overlap itself by 2 mm max. 3 3 Cable outer jacket Ground clamp Wrap the folded over shielding mesh with 5 to 6 mm wide copper tape to assure that it will not become loose. Apply the copper tape so that the shielding mesh does not protrude from under it. 1±0.5mm Copper tape Cable outer jacket Copper tape Insert the “U” shaped shielding clamp over the copper tape as shown on the illustration. It is critical that the overlap of the copper tape is located inside the shielding clamp as shown on the illustration. Note Wires When the end of the copper tape wrapping is positioned at the open side of the ground fitting, the end portion of the copper tape wrapping will no longer be covered by the ground fitting when the ground fitting is crimped. Shielding clamp Shielding mesh Overlap of the copper tape 4 4 Commercially available pliers E Table 5 Shell size Shielding clamp Overlap of the copper tape LF07 LF10 LF13 Using commercially available pliers bend the open ends of the shielding clamp as illustrated, assuring that it stays in place. The dimension of E. between opposing edges of the shielding clamp is necessary to assure correct final crimp. E 5mm max. 7mm max. 11 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors 5 Operation Illustration No. 5 Crimping tool Forming cavity 5 Both sides of the shielding clamp must be placed in the forming cavity of the tool (as shown on the illustration) and crimped over the cable by closing the tool completely. Crimping tool Forming cavity 6 1 , 7.0 5.3 HR10A-TC-02 LF-TC-01 5.3 Applicable cable diameter Shielding clamp diameter after crimping 5mm 5.3mm to 5.5mm 7.0 ––– ––– 7.9 7.3mm 9.1 8.7mm 7.9mm to 8.1mm 9.1mm to 9.3mm Connector Assembly 2 Threaded section 1 Backshell Place the body/insulator assembly in the applicable solder termination fixture. For plug assembly Fixture Part No. LF07BP-T01 LF10BP-T01 LF13BP-T01 Applicable connector LF07WBP-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P For jack assembly Fixture Part No. LF07BJ-T01 LF10BJ-T01 LF13BJ-T01 2 Wrench width : D Table 6 (Recommend tightening torgue) Shell size Tightening torque Wrench width LF07 LF10 LF13 3 , 4 1N·m~1.5N·m 1N·m~1.5N·m 10mm 1.5N·m~2N·m 16mm 13mm Groove Protrusion Tightening collar 5 Threaded section Tightening collar 12 Coat the thread section of the body/insulator assembly with Loctite 271 compound (manufactured by Henckel Japan, Ltd.) or equivalent, tightening it with a torque specified in the table 6. Note It is critical that the cable itself will not turn or twist during this operation. It may cause breakage at the soldered area. 3 Slide forward the seal bushing and insert it in the backshell until fully seated. 4 Slide forward the strain relief collar and insert it in the backshell, making sure that the opposing protrusions fit inside the corresponding grooves, as shown on the illustration. Seal bushing Strain relief collar Applicable connector LF07WBJ-6S,6P,3S,3P LF10WBJ-4S,4P,12S,12P LF13WBJ-20S,20P,11S,11P Note It is critical that the protrusions are inside the corresponding grooves. It may cause breakage, when a tightening collar is assembled. 5 Verify that the Locktite 7649 primer (or equivalent) on the threaded sections of the backshell and tightening collar are dry. Apply the Locktite 271 compound to the tightening collar’s threaded section and attach it to the backshell. The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors 6 Operation Illustration No. 6 Tightening collar 6 Remove the connector from the solder termination fixture, holding it by the locking collar. Do not pull on the cable. It may cause breakage. Recommended tightening torgue Wrench width Shell size Tightening torque Wrench width LF07 LF10 LF13 0.8N·m~1N·m 0.7N·m~1N·m 10mm 1 N·m~1.5 N·m 16mm 13mm 1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter. 2. Consult HRS representative when using different cables. ■Cable Specifications (Reference) Jacket Shield Insulator Conductor No. of contact 4 pos. 3 pos. 12 pos. 6 pos. 11 pos. 20 pos. Material Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Size (mm) Ø0.18 Ø0.26 Ø0.16 Ø0.16 Ø0.16 Ø0.26 Construction 20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. Size (AWG) AWG #20 AWG #16 AWG #26 AWG #26 AWG #26 AWG #16 AWG #26 Sectional area 0.5 1.25 0.14 0.14 0.14 1.25 0.14 Diameter (mm) Ø0.98 Ø1.5 Ø0.48 Ø0.48 Ø0.48 Ø1.5 Ø0.48 Diameter (mm) Ø1.5 (Standard) Ø2.1 (Standard) Ø0.88 (Standard) Ø0.9 (Standard) Ø0.9 (Standard) Ø2.1 (Standard) Ø0.95 (Standard) Ø0.16 0.3 0.2 0.21 0.21 0.3 Material Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Density 85% 80% 85% 80% 80% 80% Diameter (mm) Ø3.6 Ø5.5 Ø3.4 Ø4.2 Ø5.1 Ø6.7 Diameter (mm) Ø5±0.2 Ø7.3±0.2 Ø5±0.2 Ø7.3±0.2 Ø8.7±0.2 Thickness (mm) 0.26 0.24 Ø8.7±0.2 13 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors NOTES : 14 The product information in this catalog is for reference only. Please request the Engineering Drawing forLF theSeries●Miniature most current and accurate designShielded information. Waterproof Connectors NOTES : 15 The product information in this catalog is for reference Please request the Engineering Drawing for the most current and accurate design information. LF Series●Miniature Waterproof Shieldedonly. Connectors USA: HIROSE ELECTRIC (U.S.A.), INC. Headquarters 2688 Westhills Court, Simi Valley, CA 93065-6235 Phone : 1-805-522-7958 Fax : 1-805-522-3217 http://www.hiroseusa.com USA: HIROSE ELECTRIC (U.S.A.), INC. North California Office 20400 Stevens Creek Blvd., Ste 250, Cupertino, CA 95014 Phone : 1-408-253-9640 Fax : 1-408-253-9641 http://www.hiroseusa.com USA: HIROSE ELECTRIC (U.S.A.), INC. Detroit Office (Automotive) 37677 Professional Center Drive, Suite #100C Livonia, MI 48154 Phone : 1-734-542-9963 Fax : 1-734-542-9964 http://www.hiroseusa.com GERMANY: HIROSE ELECTRIC EUROPE B.V. GERMAN BRANCH Herzog-Carl-Strasse 4 D-73760 Ostfildern (Scharnhauser Park) Phone : 49-711-4560-02-1 Fax : 49-711-4560-02-299 http://www.hirose.de THE NETHERLANDS: HIROSE ELECTRIC EUROPE B.V. Hogehillweg #8 1101 CC Amsterdam Z-O Phone : 31-20-6557460 Fax : 31-20-6557469 http://www.hiroseeurope.com UK: HIROSE ELECTRIC EUROPE B.V. UK BRANCH First Floor, St Andrews House, Caldecotte Lake Business Park, Milton Keynes MK7 8LE Phone : 44-1908-369060 Fax : 44-1908-369078 http://www.hirose.co.uk CHINA: HIROSE ELECTRIC (SHANGHAI) CO., LTD. BEIJING BRANCH A1001, Ocean International Center, Building 56# East 4th Ring Middle Road, Chao Yang District, Beijing, 100025 Phone : 86-10-5165-9332 Fax : 86-10-5908-1381 http://www.hirose-china.com.cn CHINA: CHINA: HIROSE ELECTRIC TECHNOLOGIES (SHENZHEN) CO., LTD. HIROSE ELECTRIC (SHANGHAI) CO., LTD. 1601,Henderson Metropolitan,NO.300 ,East Nanjing Room 09-13, 19/F, Office Tower Shun Hing Square, Di Wang Commercial Centre Road,Huangpu District, Shanghai,China 200001 5002, ShenNanDong Road, ShenZhen City, Guangdong Province, 518008 Phone : 86-21-6391-3355 Phone : 86-755-8207-0851 Fax : 86-21-6391-3335 Fax : 86-755-8207-0873 http://www.hirose-china.com.cn http://www.hirose-china.com.cn HONG KONG: HIROSE ELECTRIC HONGKONG TRADING CO., LTD. Room 1001, West Wing, Tsim Sha Tsui Centre, 66 Mody Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone : 852-2803-5338 Fax : 852-2591-6560 http://www.hirose-hongkong.com.hk TAIWAN: HIROSE ELECTRIC TAIWAN CO., LTD. 103 8F, No.87, Zhengzhou Rd., Taipei Phone : 886-2-2555-7377 Fax : 886-2-2555-7350 http://www.hirose-taiwan.com.tw SINGAPORE: HIROSE ELECTRIC SINGAPORE PTE. LTD. 10 Anson Road #26-16 International Plaza 079903 Phone : 65-6324-6113 Fax : 65-6324-6123 http://www.hirose-singapore.com.sg KOREA: HIROSE KOREA CO., LTD. 1261-10, Jeoungwhang-Dong, Shihung-City, Kyunggi-Do 429-450 Phone : 82-31-496-7000,7124 Fax : 82-31-496-7100 http://www.hirose.co.kr ® 16 5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN PHONE: 81-3-3491-5300, FAX: 81-3-3495-5230 http://www.hirose.com http://www.hirose-connectors.com The contents of this catalog are current as of date of 05/2011. Contents are subject to change without notice for the purpose of improvements.