Rev. 5/10 20 TO 250 MHz TO-8 GAIN CONTROL AMPLIFIER AGC230 AGC230 Typical Values Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High AGC Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HighControl Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Noise Figure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Performance Thin Film Standard Size TO-8 Package 46 dB 50.0 dB 0 to +5 Volts 5.0 dB AGC230Package TO-8 Attenuator TO-8 Package for Gain Control Amplifiers SPECIFICATIONS* Parameter Typical Frequency (Min.) 10-300 MHz Gain (Min.) @ V contr. = 0 Volts 46.0 dB Gain (Max.) @ V contr.=+5 Volts — Guaranteed 0 to 50 °C -55 to +85 °C 20-250 MHz 20-250 MHz 42.0 dB 40.0 dB -5.0 dB -1.0 dB Gain Flatness (Max.) @ V contr. = 0 Volts 20-100 MHz 100-250 MHz ±0.5 dB ±1.5 dB ±1.0 dB ±2.0 dB ±1.5 dB ±2.5 dB Noise Figure (Max.) @ V contr. = 0 Volts 5.0 dB 6.0 dB 6.5 dB SWR (Max.) < 1.6:1 2.0:1 2.0:1 +8.5 dBm +7.5 dBm +7.0 dBm 10 µsec 5 µsec — — Input/Output Power Output (Min.) @1dB comp. @V contr. = 0 Volts Response Time Full AGC 20 dB AGC Connectorized attenuator case available. DIMENSIONS ARE IN INCHES [MILLIMETERS] SWITCHING SPEED * Measured in a 50-ohm system at +15 Vdc unless otherwise specified. ^ AGC Voltage: 0 to +5 Volts Typical Switching Speed at 25 °C Teledyne Cougar • 408-522-3838 • 408-522-3839 fax www.teledyne-cougar.com • [email protected] INTERMODULATION PERFORMANCE Typical @ 25 °C Vcontrol = 0 Volts Second Order Harmonic Intercept Point . . . . . . . . . . . . . . . Second Order Two Tone Intercept Point . . . . . . . . . . . . . . . Third Order Two Tone Intercept Point . . . . . . . . . . . . . . . . . AGC230 +39 dBm +33 dBm +21 dBm ABSOLUTE MAXIMUM RATINGS Full AGC, 100 MHz Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -62 to +125 °C Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . . +125 °C Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +18 Volts Maximum Continuous RF Input Power . . . . . . . . . . . . . . . . +13 dBm Maximum Short Term Input Power (1 Minute Max.) . . . . . . . 50 Milliwatts Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . . 0.5 Watt Maximum Control Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . +7.0 Volts Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +125 °C Thermal Resistance1 (θjc) . . . . . . . . . . . . . . . . . . . . . . . . . . . +12 °C/Watt Junction Temperature Rise Above Case (Tjc) . . . . . . . . . . . +12.0 °C 1 Thermal resistance is based on total power dissipation. 20 dB AGC, 100 MHz 650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • [email protected] AGC230 TYPICAL PERFORMANCE TYPICAL AUTOMATIC TEST DATA KEY: +25 °C +85 °C -55 °C Gain vs Frequency vs Control Voltage 50 Vc=0 40 Vc=1 20 Vc=2 10 Vc=3 Vc=4 Vc=5 0 -10 -20 10 20 50 100 150 200 250 FREQUENCY - MHz 300 350 Phase vs Frequency 210 190 PHASE - DEGREES 170 150 Vc=5 130 Vc=4 Icc = 61.00 mA MODEL: AGC230 VSWR FREQ MHZ IN 10 1.4 1.3 20 50 1.2 100 1.2 1.3 150 200 1.3 250 1.3 1.2 300 Vcc = +15V VSWR GAIN OUT DB 1.5 22.8 1.6 21.3 1.6 19.8 1.6 18.6 1.6 17.9 1.6 17.3 1.6 16.3 1.6 15.7 Icc = 61.01 mA MODEL: AGC230 FREQ VSWR MHZ IN 10 1.8 1.7 20 50 1.8 100 1.7 1.8 150 200 1.9 250 1.7 1.8 300 Vcc = +15V VSWR GAIN OUT DB 1.7 -3.8 1.7 -5.1 1.7 -7.8 1.7 -8.2 1.7 -7.8 1.7 -7.4 1.7 -7.0 1.7 -6.6 Icc = 61.02 mA Vcontrol = 0.0V S21 ANG -154.6 -177.9 159.6 134.6 107.3 88.9 69.6 52.8 S21 MAG 13.9 11.6 9.8 8.5 7.9 7.4 6.5 6.1 Vcontrol = 2.0 V S21 ANG -167.9 169.0 153.1 135.9 113.4 98.9 81.6 67.0 S21 MAG 0.6 0.6 0.4 0.4 0.4 0.4 0.4 0.5 Vcontrol = 5.0 V S21 ANG -167.1 168.8 164.8 165.9 146.5 149.0 139.8 135.9 Vc=3 90 Vc=2 Vc=1 Vc=0 50 30 10 20 50 100 150 200 250 FREQUENCY - MHz 300 350 Power vs. Attenuation vs. Voltage 10 70 MHz 0 - 10 - 20 0 1 Noise Figure Vcc= +15 2 3 4 VDC CONTROL VOLTAGE 5 6 5 6 Gain vs. Control Voltage 7.0 50 GAIN - dB 6.0 Vc=0 5.0 4.0 10 20 50 100 150 200 250 FREQUENCY - MHz 300 350 30 100 MHz 10 - 10 0 1 Power Output at 1 dB Compression INTERCEPT POINT - dBm 10.0 +15v, Vc=0 9.0 8.0 7.0 6.0 5.0 +12v, Vc=0 3.0 10 20 50 100 150 200 250 FREQUENCY - MHz 300 350 2 3 4 VDC CONTROL VOLTAGE Intercept Point Vcc= +15, Vc= 1.5 40 30 20 2nd HAR IP 2 IP 3 10 0 10 4.0 INTERCEPT POINT - dBm OUTPUT POWER - dBm S21 MAG 243.8 240.9 239.7 220.8 200.7 183.3 159.7 148.3 110 70 NOISE FIGURE - dB Vcc = +15V VSWR GAIN OUT DB 1.1 47.7 1.0 47.6 1.1 47.6 1.1 46.9 1.1 46.1 1.1 45.3 1.1 44.1 1.1 43.4 OUTPUT POWER - dBm GAIN - dB 30 MODEL: AGC230 VSWR FREQ MHZ IN 1.3 10 20 1.2 50 1.1 1.1 100 150 1.1 200 1.1 1.1 250 300 1.1 20 50 100 150 200 250 FREQUENCY - MHz 300 350 Intercept Point Vcc= +15, Vc= 0 50 2nd HAR 40 IP 2 30 IP 3 20 10 10 20 50 100 150 200 250 FREQUENCY - MHz 650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • [email protected] 300 350