XP Power ECL25US12 Pcb mount Datasheet

AC-DC
25 Watts
xppower.com
ECL25 Series
•
Ultra Compact Size
•
Low Cost
•
Single Outputs from 3.3 to 48 V
•
PCB Mount & Open Frame
•
Encapsulated PCB Mount
•
Class II
•
Peak Load Capability
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Input Protection
General
•
•
•
•
•
•
85-264 VAC (120-370 VDC)
47-63 Hz
0.4 A rms at 230 VAC
20 A at 115 VAC, 40 A at 230 VAC,
Class II construction no earth
Internal 2 A fuse
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
See tables
±5% (not encapsulated units)
±1%
No minimum load required
2 s max
14 ms max
16 ms typical at full load & 115 VAC
±0.5% max
±1% max
4% max deviation, recovery to within
1% in 500 µs for a 25% load change
3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
20 MHz BW
115-135% Vnom, recycle input to reset
120-170%
Trip and restart (Hiccup mode)
0.05%/°C
Output
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
•
•
•
•
•
See tables
3000 VAC Input to Output
70 kHz typical
5.6 W/In3 (PCB Mount version)
>400 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • -20 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
• Convection-cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 2 g, 10 Hz to 500 kHz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
•
•
•
•
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
•
•
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, 10 Vrms Perf Criteria A
EN61000-4-8, 10 A/m Perf Criteria A
EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
EN60950, UL60950,
CSA22.2 No. 234 per cUL
Output
Power
20 W
25 W
25 W
25 W
25 W
25 W
25 W
Output Current
Output
Voltage
3.3 VDC
5.0 VDC
9.0 VDC
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
Nominal
6.00 A
5.00 A
2.80 A
2.10 A
1.67 A
1.04 A
0.52 A
Model
Number(2)
ECL25US03
ECL25US05
ECL25US09
ECL25US12
ECL25US15
ECL25US24
ECL25US48
Efficiency
Peak(1)
7.80 A
6.50 A
3.64 A
2.73 A
2.17 A
1.35 A
0.68 A
75%
78%
80%
80%
80%
82%
82%
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
2. Add suffix to model number to define type: add ‘-P’ for PCB mount, add ‘-T’ for chassis mount, add ‘-E’ for encapsulated.
Mechanical Details
Open Frame - PCB Mount (-P)
3.00
(76.2)
ACN
-Vo
1.18
(30.0)
1.40
(35.6)
ACL
+Vo
0.08
(1.9)
0.11
(2.8)
0.17
(4.4)
Encapsulated (-E)
0.59
(15.0)
2.85
(72.4)
0.11
(2.8)
1.10
(27.9)
0.88
(22.3) MAX
4 x ø0.04 (ø1.00)
0.15
(3.8)
0.39
(10.0)
1.50
(38.1)
ø0.04 (ø1.0)
0.59 (15.0)
ø0.07 (ø 1.8)
+Vo
-Vo
Open Frame - Chassis Mount (-T)
3.50
(88.9)
3.10
(78.7)
4- 0.15 (3.81)
1.40
(35.6)
1.10
(27.9)
BOTTOM VIEW
2.85
(72.4)
-Vo
ACN
ACL
+Vo
ACL
0.15
(3.8)
0.15
(3.8)
ACN
3.20 (81.3)
0.16 (4.1)
0.13
(3.2)
1.18 (30.0)
0.12
0.88
(3.0) (22.4) MAX
Notes
1. Dimensions in inches (mm).
2. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5)
x.xxx = ± 0.01 (x.xx = ± 0.25)
Mating Connectors (Chassis mount only)
Input Connector: JST XHP-3
Output Connector: JST XHP-6
Crimps: SXH-002T-P0.6
Cable harness with 300 mm wire available, order part no. ECL25 LOOM KIT
10-Oct-08
AC-DC
ECL25
Models and Ratings
Similar pages