XP Power AKM36US18C2 Ac-dc power supply Datasheet

AKM36 Series
AC-DC Power Supplies
36 Watt
xxx Series
• Energy Efficiency Level VI
• European CoC Tier 2
• Medical and ITE Approvals
• Class II Construction
• Optional White Versions
• Output Voltages from 9 V to 36 V
• 3 Years Warranty
The AKM36 series of desktop adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and
medical applications while maintaining industry leading performance.
Dimensions:
AKM:
4.25 x 1.97 x 1.33” (108.0 x 50.0 x 33.8 mm)
Models & Ratings
Output Power
36 W
Output Voltage
Output Current
Total Regulation(1)
Efficiency(2)
Model Number(3)
AKM36US09C2
9.0 V
4.0 A
5%
88.9%
12.0 V
3.0 A
5%
89.3%
AKM36US12C2
15.0 V
2.4 A
5%
88.4%
AKM36US15C2
18.0 V
2.0 A
5%
89.5%
AKM36US18C2
24.0 V
1.5 A
5%
89.4%
AKM36US24C2
30.0 V
1.2 A
5%
89.9%
AKM36US30C2
36.0 V
1.0 A
5%
89.2%
AKM36US36C2
Notes
1. Total regulation includes initial set accuracy, line and load regulation.
2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC.
3. For white case version add suffix ‘-W’ e.g. AKM36US12C2-W. MOQ applies,
contact sales for details.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
90
47
Typical
Maximum
264
63
1.0
70
Units
VAC
Hz
A
A
75
mW
Maximum
36
5
Units
V
A
s
ms
ms
%
4
% deviation
Ripple & Noise
200
mV pk-pk
Short Circuit Protection
Temperature Coefficient
0.05
%/ ˚C
Notes & Conditions
90 VAC
230 VAC, cold start at 25 °C
EN61000-3-2, class A
Internal fuse in line
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Transient Response
1
Minimum
9
0
Typical
4
30
10
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Continuous, trip and restart (hiccup mode) with auto recovery
www.xppower.com
AKM36 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Notes & Conditions
Units
Typical average of efficiencies measured at 25%, 50%, 75%
and 100% load and 115 VAC input
%
89.5
Energy Efficiency
Level VI
4000
Isolation
Leakage Current
24
Mean Time Between Failure
200
70
0.53 (240)
Weight
Input to Output, 2 x MOPP
kHz
kHrs
264 VAC, 60 Hz
µA
50
Switching Frequency
VAC
Variable
MIL-HDBK-217F at 25 °C GB
lb (g)
Environmental
Characteristic
Minimum
Maximum
Units
0
+40
°C
Storage Temperature
-20
+70
°C
Operating Humidity
5
90
%
5000
m
Operating Temperature
Typical
Operating Altitude
Notes & Conditions
RH, non-condensing
Cooling
Natural convection
Shock
1 m drop onto concrete on each of 6 axes, non operating
10
Vibration
Hz
300
2 g, 0.3 decades/min, 15 mins for each of 3 axes
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Level B
Radiated
EN55032
Level B
Harmonic Current
EN61000-3-2
Class A
Voltage Flicker
EN61000-3-3
Notes & Conditions
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
as below
EN61204-3
High severity level
ESD Immunity
EN61000-4-2
±8 kV contact, ±15 kV air
A
Radiated Immunity
EN61000-4-3
10 V/m
A
A
EFT/Burst
EN61000-4-4
Level 3
Surge
EN61000-4-5
Level 2
A
Conducted Immunity
EN61000-4-6
6V
A
Magnetic Fields
EN61000-4-8
30 A/m
Int: 100% 10 ms
Dip: 30% 500 ms
A
A
A/B
Int: 100% 5000 ms
B
Dip: 30% 25 AC Cycles
A/B
Int: 100% 0.5 AC Cycle
A
Int: 100% 1 AC Cycle
A/B
Int.: >95% 5000 ms
B
EN61000-4-11
Dips and Interruptions
EN60601-1-2
Notes & Conditions
High Line/Low Line
High Line/Low Line
At 8 angles
High Line/Low Line
Safety Approvals
Safety Agency
UL
Safety Standard
Notes & Conditions
UL60950-1
TUV
EN60950-1
CB
IEC60950-1
CE
LVD
UL
ANSI/AAMI ES 60601-1
CSA
CSA C22.2 No. 60601
TUV
EN60601-1
CB
IEC60601-1
Information Technology
Medical, 2 x MOPP
www.xppower.com
2
AKM36 Series
AC-DC Power Supplies
Mechanical Details
AKM36USXXC2
ø0.21 ±0.001 (ø5.5 ±0.05)
ø0.09 ±1.5 (ø2.5 ±0.1)
0.05 ±0.003 (1.5 ±0.1)
1.33 ±0.02
(33.8 ±0.6)
0.43 ±0.01 (11.0 ±0.3)
59.0 ±3.93 (1500 ±100)
4.25 ±0.03 (108.0 ±0.8)
1.96 ±0.02
(50.0 ±0.6)
Notes
1. Dimensions in inches (mm).
3
2. Weight: 0.53 lbs (240 g).
www.xppower.com