Issue: 01 Date: 2005-12-08 Specification AXHV5010 Oscillator type : VCO – Voltage Controlled Oscillator in TO-8 package Parameter min. typ. max. Unit Condition 9500 10400 MHz @ 25°C Frequency tuning range Frequency adjustment range EFC voltage VC 0 15 V 35 85 MHz/V Tuning sensitivity (∆f / ∆VC) EFC slope positive RF output Signal waveform SINUS Amplitude +8.5 +11 dBm RL = 50 Ω Harmonics -15 dBc -85 dBc/Hz @ 100 kHz Phase Noise Supply voltage VS 4.75 5 5.25 V Current consumption (steady state) 100 mA -40 +85 °C Operating temperature range -45 +90 °C Operable temperature range -55 +95 °C Storage temperature range 12.7 Ø x 5.5 mm “TO-8” Enclosure (see drawing) DiameterxH 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXHV5010 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Frequency Range [MHz] 9500-10400 AXHV5010 page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Pin connections Enclosure drawing Pin # 1 2 3 4 Symbol RF OUT VS VC GND Function RF Output Supply Voltage (Bias) Control Voltage (EFC) Ground bottom view Typical Performance HV5010 f/GHz 10,6 10,4 10,2 10 9,8 9,6 9,4 0 5 10 15 Vtune/V GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV5010 page 2(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Sensivitiy(MHz/V) HV5010 150 100 50 0 0 5 10 15 10 15 Vtune/V HV5010 Pout/dBm 12 10 8 6 4 2 0 0 5 Vtune/V GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV5010 page 3(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV5010 page 4(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]