AZETTLER AZ900 30 amp heavy duty power relay Datasheet

AZ900
30 AMP HEAVY DUTY
POWER RELAY
FEATURES
•
•
•
•
1 Form C contacts, 2 Form C contacts
AC and DC coils available
UL Class F (155°C) molded construction
UL, CUL file E44211
CONTACTS
Arrangement
Ratings
UL, CUR
Material
Resistance
GENERAL DATA
SPDT (1 Form C) DPDT (2 Form C)
Resistive load:
Max. switched power: 840 W or 12000 VA
Max. switched current: 30 A
Max. switched voltage: 600 VAC, 28 VDC
30 A at 240 VAC
1.5 HP at 120 VAC
2.0 HP at 240 VAC
3600 VA at 120 VAC / 240 VAC ballast
30 A at 240 VAC Res., 100k cycles
20 A at 600 VAC
30 A at 28 VDC
Silver cadmium oxide
< 50 milliohms initially
(24 V, 1 A voltage drop method)
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 107
1 x 105 at 30 A 240 VAC Res.
Operate Time (typical)
30 msec at nominal coil voltage
Release Time (typical)
30 msec at nominal coil voltage
(without suppression)
Dielectric Strength
2200 Vrms contact to contact
2200 Vrms contact to coil
(at sea level for 1 min.)
Insulation Resistance
100 megohms min. at 20°C, 500 VDC
50% RH
Dropout
DC: > 10% of nominal coil voltage
AC: > 20% of nominal coil voltage
Ambient Temperature
Operating
Weight
-45°C (-49°F) to 80°C (176°F) AC coil, 30A
-45°C (-49°F) to 115°C (239°F) DC coil, 30A
227 grams
COIL
Power
At Pickup Voltage
(typical)
DC: 1.12 mW
AC: 6.9 VA
Max. Continuous
Dissipation
DC: 3.3 W at 20°C
AC: 12.5 VA at 20°C
Temperature Rise
70°C at nominal coil voltage (AC)
35°C at nominal coil voltage (DC)
1. All values at 25°C (77°F).
155°C (311°F)
3. Specifications subject to change without notice.
Max. Temperature
NOTES
2. Relay may pull in with less than “Must Operate” value.
9/12/05
AZ900
RELAY ORDERING DATA
COIL SPECIFICATIONS – DC Coil
Nominal Current
mA ± 10%
333
Coil Resistance
± 10%
18
ORDER NUMBER*
Nominal Coil
VDC
6
Must Operate
VDC
4.50
Max. Continuous
VDC
7.8
12
9.1
15.4
166
72
AZ900–1C–12D
24
18.0
32.0
83
290
AZ900–1C–24D
48
36.0
62.6
42
1150
AZ900–1C–48D
110
82.5
143.0
18.2
6050
AZ900–1C–110D
AZ900–1C–6D
COIL SPECIFICATIONS – AC Coil 50/60 Hz
Nominal Coil
VAC
6
Must Operate
VAC
5.1
Max. Continuous
VAC
6.9
Nominal Coil
Power VA
9.5
12
10.2
13.8
9.5
Coil Resistance
± 10%
0.85
ORDER NUMBER*
2.85
AZ900–1C–6A
AZ900–1C–12A
24
20.4
27.6
9.5
11.5
AZ900–1C–24A
120
102.0
138.0
9.5
295.0
AZ900–1C–120A
240
204.0
276.0
9.5
1170.0
AZ900–1C–240A
480
408.0
552.0
9.5
4860.0
AZ900–1C–480A
*For double pole version replace ‘-1C’ with ‘-2C.’
MECHANICAL DATA
WIRING DIAGRAM
8
6
4
7
5
3
2
1
2 Form C
7
5
3
2
1
1 Form C
2 Form C
1 Form C
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
9/12/05
Similar pages