ACDC 90150 Watts AMM Series xppower.com • CEC2008 & EISA2007 Compliant • Worldwide Medical Approvals • Class I and Class II Versions • High Power Density • High Efficiency • Operating Temperature up to +60 °C • 3 Year Warranty Specification Input General • 90 W: 80-264 VAC, derate output power 10% <90 VAC & 15% <85 VAC, 120/150 W: 80-264 VAC, derate output power 15% <90 VAC & 20% <85 VAC Input Frequency • 47-63 Hz Input Current • 90 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC 120 W: 1.6 A at 115 VAC, 0.8 A at 230 VAC 150 W: 2 A at 115 VAC, 1.0 A at 230 VAC Inrush Current • 60 A max at 115 VAC, 120 A max at 230 VAC, cold start +25 °C Power Factor • 0.98 typical Earth Leakage Current • 90 µA max at 115 VAC/60 Hz, (Class I Versions) 150 µA max at 230 VAC/50 Hz Input Protection • 90 W: Internal T2.5 A/250 V fuse in line and neutral lines, 120 W: Internal T3.15 A/250 V fuse in line and neutral lines, 150 W: Internal T4 A/250 V fuse in line and neutral lines No Load Input Power • <0.5 W Input Voltage Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay • • • • • Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • Ripple & Noise • Overvoltage Protection • Overtemperature • Protection Overload Protection • Short Circuit Protection • Temperature • Coefficient See tables Not user-adjustable ±2%, set at 60% load No minimum load required 90/120 W: 2 s max at 115 VAC, 150 W: 3 s max at 115 VAC <80 ms at 115 VAC 15 ms minimum at full load & 115 VAC 0.5% maximum See tables 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change 2% max pk-pk (see note 1) 110-140% Vnom, recycle input to reset 90/150 W: Unit shuts down, auto recovery 120 W: Unit shuts down, recycle input to reset 110-180%, auto recovery Trip and restart (Hiccup mode) 0.04%/°C Efficiency Isolation Switching Frequency Power Density MTBF • 85% typical • 4000 VAC Input to Output 1500 VAC Input to Ground (Class I only) 500 VAC Output to Ground (Class I only) • 50-110 kHz variable • 90 W: 3.4 W/In3, 120 W: 3.7 W/In3 150 W: 2.9 W/In3 • 150 kHrs typical to MIL-HDBK-217F at 25 şC, GB Environmental Operating Temperature • 0 °C to +60 °C, derate linearly from 100% power at +40 °C to 50% power at +60 °C Cooling • Convection-cooled Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 şC to +85 şC Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55011/FCC/VCCI, Class B conducted EN55011/FCC/VCCI, Class B radiated • EN61000-3-2, Class A • EN61000-3-3 • EN61000-4-2, level 3 Perf Criteria A • EN61000-4-3, level 2 Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN61000-4-6, 3 V Perf Criteria A • EN61000-4-8, 3 A/m Perf Criteria A • EN61000-4-11 90/120 W: 70% 10 ms, 40% 100 ms, <5% 5000 ms, Perf Criteria A, B, B (Perf Criteria A, A, B with 70% load) 150 W: >95% 10 ms, 60% 100 ms, <30% 500 ms, Perf Criteria A, B, B • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL Output Power 60 W 60 W 70 W 80 W 85 W 85 W 90 W 90 W 90 W 90 W 90 W Output Voltage 5.0 V 6.0 V 9.0 V 12.0 V 13.5 V 15.0 V 18.0 V 19.0 V 24.0 V 30.0 V 48.0 V Total Regulation(2) 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Output Current 12.00 A 10.00 A 7.78 A 6.67 A 6.30 A 5.67 A 5.00 A 4.74 A 3.75 A 3.00 A 1.87 A Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For class II versions, add ‘ C2’ to model number e.g. AMM90PS24C2. Model Number(3, 4) AMM90PS05(5) AMM90PS06(5) AMM90PS09(5) AMM90PS12 AMM90PS13 AMM90PS15 AMM90PS18 AMM90PS19 AMM90PS24 AMM90PS30 AMM90PS48 4. For optional Barrel Jack Connector, add ‘ B1’ to model number e.g. AMM90PS24C2B1 (not available on 5 V or 6 V models). 5. Not CEC2008 or EISA2007 compliant. Mechanical Details 1 3 Cable length approx 48” (1219mm) 2 4 1.72 PIN CONNECTIONS PS05 - PS06 Pin Function 1 Return 2 Return 3 Output+ 4 Return 5 Output+ (43.7) 3 Rubber foot (4 places.) 5 2 1 1 4 PIN CONNECTIONS PS09 - PS48 Pin Function 1 Return 2 Output+ 3 Return 4 Output+ 3 5.12 (130.0) 2 3.00 (76.2) 4 Optional Barrel Jack Connector 0.02 (0.5) 0.433 (11.0) 0.083 (2.1) 0.217 (5.5) 0.413 (10.5) AC Input IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 1.46 lb (660 g). 3. Maximum load per pin on output connector is 7.5 A. 4. Output connector for AMM90PS05 and PS06 is 5 pin 180° DIN. 5. Output connector for AMM90PS09-PS13 is 4 Pin DC Power Plug non locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6. Output connector for AMM90PS15-PS48 is 4 Pin DC Power Plug locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 7. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 8. For European mains lead order part: EU-MAINS-IEC 9. For UK mains lead order part: UK-MAINS-IEC 10. For US mains lead order part: US-MAINS-IEC 11. Mains lead length is 76“ (1930 mm) approx ACDC AMM90 Models and Ratings Output Power 96 W 105 W 120 W 120 W 120 W 120 W 120 W 120 W 120 W Output Voltage 12 V 15 V 18 V 19 V 20 V 24 V 30 V 36 V 48 V Output Current 8.00 A 7.00 A 6.67 A 6.32 A 6.00 A 5.00 A 4.00 A 3.34 A 2.50 A Total Regulation(2) 5% 5% 5% 5% 5% 5% 5% 5% 5% Model Number(3, 4) AMM120PS12 AMM120PS15 AMM120PS18 AMM120PS19 AMM120PS20 AMM120PS24 AMM120PS30 AMM120PS36 AMM120PS48 Notes 1. 2. 3. 4. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. Total regulation includes initial set accuracy, line and load regulation. For Class II versions, add ‘ C2’ to model number e.g. AMM120PS24C2. For optional barrel jack connector add suffix ‘ B1’ to model number e.g. AMM120PS24C2B1. Mechanical Details 1 3 Cable length approx 48” (1220mm) 2 4 1.72 Power On Indicator (43.7) Rubber foot (4 places.) 6.30 (160.0) 1 3 2 4 Pin 1 2 3 4 Function Return Output+ Return Output+ Optional Barrel Jack Connector 0.433 (11.0) 0.217 (5.5) 3.00 (76.2) 0.083 (2.1) 0.413 (10.5) 0.02 (0.5) ACDC AMM120 Models and Ratings AC Input IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight 1.72 lbs (780 g). 3. Maximum load per pin on output connector is 5 A. 4. Output connector for AMM120PS12 & PS15 is 4 Pin DC Power Plug, non-locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 5. Output connector for AMM120PS18-PS48 is 4 Pin DC Power Plug, locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 7. For European mains lead order part: EU-MAINS-IEC 8. For UK mains lead order part: UK-MAINS-IEC 9. For US mains lead order part: US-MAINS-IEC 10. Mains lead length is 76“ (1930 mm) approx Output Power 132 W 144 W 150 W 150 W 150 W 150 W Output Voltage 12 V 15 V 19 V 24 V 27 V 48 V Total Regulation(2) 5% 5% 5% 5% 5% 5% Output Current 11.00 A 9.60 A 7.90 A 6.25 A 5.56 A 3.13 A Model Number(4,5) AMM150PS12 AMM150PS15 AMM150PS19(6) AMM150PS24(3,6) AMM150PS27(3,6) AMM150PS48(3,6) Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic capacitor connected at the measurement point. 2. Total regulation includes set accuracy, line and load regulation. 3. For optional barrel jack connector, add suffix ‘ B1’ to the model number e.g. AMM150PS24B1 (not available on 12 V models) 4. For optional AC cable restraint on the Class I Version, add suffix ‘ A’ to the model number e.g. AMM150PS24A or AMM150PS24B1A. AC mains lead must be Interpower Corporation, part number: 70006020300. Optional AC cable restraint is not available on the Class II Version. 5. For Class II Versions, and ‘ C2’ to model number, eg. AMM150PS24C2. 6. Energy Star Level V. Mechanical Details 1 3 Cable length approx 48” (1219 mm) 2 4 1.96 Power On Indicator (49.7) Rubber foot (4 places.) 8.17 (207.6) 1 3 2 4 Pin 1 2 3 4 Function Return Output+ Return Output+ Optional Barrel Jack Connector 0.433 (11.0) 3.23 (82.0) 0.413 (10.5) 0.02 (0.5) 0.083 (2.1) 0.217 (5.5) Notes AC Input IEC 320/C14 Inlet - For Class I Version IEC 320/C18 Inlet - For Class II Version 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 2.16 lbs (980 g). 3. Output connector is 4 Pin DC Power Plug, locking type. For mating half, use KYCON KPJX-4S-S or equivalent. 4. For Class I versions shell is connected to ground. For Class II Versions shell is capacitively coupled to input. 5. 6. 7. 8. For European mains lead order part: EU-MAINS-IEC For UK mains lead order part: UK-MAINS-IEC For US mains lead order part: US-MAINS-IEC Mains lead length is 78“ (2000 mm) approx 31-Jan-12 ACDC AMM150 Models and Ratings