AD AD7147PACPZ-1500R7 Captouch programmable controller Datasheet

FEATURES
FUNCTIONAL BLOCK DIAGRAM
APPLICATIONS
ACSHIELD VCC
8
GND
BIAS
10
9
11
POWER-ON
RESET LOGIC
CIN0 19
CIN1 20
CIN2 21
EXCITATION
SOURCE
CIN3 22
CIN4 23
CIN5 24
CIN6 1
CIN7 2
CIN8 3
CIN9
CALIBRATION
RAM
AD7147/
AD7147-1
16-BIT
Σ-∆
CDC
4
CALIBRATION
ENGINE
CIN10 5
CIN11 6
CONTROL
AND DATA
REGISTERS
CIN12 7
VDRIVE 12
INTERRUPT
AND GPIO
LOGIC
SERIAL INTERFACE
AND CONTROL LOGIC
13
14
15
16
18
GPIO
17
SDO/ SDI/ SCLK CS/
SDA ADD0
ADD1
INT
06663-001
Programmable capacitance-to-digital converter (CDC)
Femtofarad resolution
13 capacitance sensor inputs
9 ms update rate, all 13 sensor inputs
No external RC components required
Automatic conversion sequencer
On-chip automatic calibration logic
Automatic compensation for environmental changes
Automatic adaptive threshold and sensitivity levels
Register map is compatible with the AD7142
On-chip RAM to store calibration data
SPI-compatible (serial-peripheral-interface-compatible)
serial interface (AD7147)
I2C-compatible serial interface (AD7147-1)
Separate VDRIVE level for serial interface
Interrupt output and general-purpose input/output (GPIO)
24-lead, 4 mm × 4 mm LFCSP
2.6 V to 3.3 V supply voltage
Low operating current
Full power mode: 1 mA
Low power mode: 21.5 μA
Qualified for automotive applications
SWITCH
MATRIX
Data Sheet
CapTouch Programmable Controller for
Single-Electrode Capacitance Sensors
AD7147
Figure 1.
Cell phones
Personal music and multimedia players
Smart handheld devices
Television, A/V, and remote controls
Gaming consoles
Digital still cameras
The AD7147 is designed for single electrode capacitance sensors
(grounded sensors). There is an active shield output to
minimize noise pickup in the sensor.
GENERAL DESCRIPTION
The AD7147 CapTouch™ controller is designed for use with
capacitance sensors implementing functions such as buttons,
scroll bars, and wheels. The sensors need only one PCB layer,
enabling ultrathin applications.
The AD7147 is an integrated CDC with on-chip environmental
calibration. The CDC has 13 inputs channeled through a switch
matrix to a 16-bit, 250 kHz sigma-delta (∑-Δ) converter. The CDC
is capable of sensing changes in the capacitance of the external
sensors and uses this information to register a sensor activation.
By programming the registers, the user has full control over the
CDC setup.
The AD7147 has on-chip calibration logic to compensate for
changes in the ambient environment. The calibration sequence
is performed automatically and at continuous intervals as long
as the sensors are not touched. This ensures that there are no
false or nonregistering touches on the external sensors due to
a changing environment.
The AD7147 has an SPI-compatible serial interface, and the
AD7147-1 has an I2C®-compatible serial interface. Both parts have
an interrupt output, as well as a GPIO. There is a VDRIVE pin to set
the voltage level for the serial interface independent of VCC.
The AD7147 is available in a 24-lead, 4 mm × 4 mm LFCSP and
operates from a 2.6 V to 3.6 V supply. The operating current consumption in low power mode is typically 26 μA for 13 sensors.
High resolution sensors require minor software to run on the
host processor.
Rev. E
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2007–2015 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
AD7147* PRODUCT PAGE QUICK LINKS
Last Content Update: 02/23/2017
COMPARABLE PARTS
REFERENCE MATERIALS
View a parametric search of comparable parts.
Technical Articles
• MS-2210: Designing Power Supplies for High Speed ADC
EVALUATION KITS
• EVAL-AD7147 & EVAL-AD7147-1 Evaluation Boards
DESIGN RESOURCES
• AD7147 Material Declaration
DOCUMENTATION
• PCN-PDN Information
Application Notes
• Quality And Reliability
• AN-925: Sensors for the AD7147 and AD7148 CapTouch®
Controllers
• Symbols and Footprints
• AN-929: Tuning the AD714x for CapTouch® Applications
DISCUSSIONS
• AN-957: Layout Guidelines for the AD7147 and AD7148
CapTouch® Controllers
View all AD7147 EngineerZone Discussions.
Data Sheet
SAMPLE AND BUY
• AD7147: CapTouch Programmable Controller for SingleElectrode Capacitance Sensors Data Sheet
Visit the product page to see pricing options.
Product Highlight
• Leading Inside Advertorials: Providing an Edge in
Capacitive Sensor Applications
SOFTWARE AND SYSTEMS REQUIREMENTS
• AD714X Input CapTouch® Programmable Controller
Linux Driver
TECHNICAL SUPPORT
Submit a technical question or find your regional support
number.
DOCUMENT FEEDBACK
Submit feedback for this data sheet.
This page is dynamically generated by Analog Devices, Inc., and inserted into this data sheet. A dynamic change to the content on this page will not
trigger a change to either the revision number or the content of the product data sheet. This dynamic page may be frequently modified.
AD7147
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Capacitance Sensor Behavior Without Calibration ............... 24
Applications ....................................................................................... 1
Threshold Equations .................................................................. 25
General Description ......................................................................... 1
Capacitance Sensor Behavior with Calibration ...................... 25
Functional Block Diagram .............................................................. 1
Slow FIFO .................................................................................... 25
Revision History ............................................................................... 3
SLOW_FILTER_UPDATE_LVL .............................................. 26
Specifications..................................................................................... 4
Adaptive Threshold and Sensitivity ............................................. 27
Average Current Specifications .................................................. 5
Interrupt Output ............................................................................. 29
SPI Timing Specifications (AD7147) ......................................... 6
CDC Conversion-Complete Interrupt .................................... 29
I C Timing Specifications (AD7147-1) ...................................... 7
Sensor-Touch Interrupt ............................................................. 29
Absolute Maximum Ratings ............................................................ 8
GPIO INT Output Control ....................................................... 31
ESD Caution .................................................................................. 8
Outputs ............................................................................................ 33
Pin Configurations and Function Descriptions ........................... 9
ACSHIELD Output .......................................................................... 33
Typical Performance Characteristics ........................................... 10
General-Purpose Input/Output (GPIO) ................................. 33
Theory of Operation ...................................................................... 12
Using the GPIO to Turn On/Off an LED ................................ 33
Capacitance Sensing Theory ..................................................... 12
Serial Interface ................................................................................ 34
BIAS Pin ....................................................................................... 13
SPI Interface ................................................................................ 34
Operating Modes ........................................................................ 13
I2C-Compatible Interface .......................................................... 36
Capacitiance-to-Digital Converter............................................... 15
VDRIVE Input ................................................................................. 38
Oversampling the CDC Output ............................................... 15
PCB Design Guidelines ................................................................. 39
Capacitance Sensor Offset Control .......................................... 15
Capacitive Sensor Board Mechanical Specifications ............. 39
Conversion Sequencer ............................................................... 15
Chip Scale Packages ................................................................... 39
CDC Conversion Sequence Time ............................................ 17
Power-Up Sequence ....................................................................... 40
CDC Conversion Results ........................................................... 17
Typical Application Circuits ......................................................... 41
Capacitance Sensor Input Configuration .................................... 18
Register Map ................................................................................... 42
CINx Input Multiplexer Setup .................................................. 18
Detailed Register Descriptions ..................................................... 43
Single-Ended Connections to the CDC .................................. 18
Bank 1 Registers ......................................................................... 43
Noncontact Proximity Detection ................................................. 19
Bank 2 Registers ......................................................................... 53
Recalibration ............................................................................... 19
Bank 3 Registers ......................................................................... 58
Proximity Sensitivity .................................................................. 19
Outline Dimensions ....................................................................... 70
FF_SKIP_CNT ............................................................................ 22
Ordering Guide .......................................................................... 70
Environmental Calibration ........................................................... 24
Automotive Products ................................................................. 70
2
Rev. E | Page 2 of 70
Data Sheet
AD7147
REVISION HISTORY
1/15—Rev. D to Rev. E
Updated Outline Dimensions ........................................................70
Changes to Ordering Guide ...........................................................70
7/09—Rev. A to Rev. B
Changes to BIAS Pin Description ................................................... 8
Changes to BIAS Pin Section ......................................................... 12
9/11—Rev. C to Rev. D
Changes to Ordering Guide ...........................................................70
8/08—Rev. 0 to Rev. A
Changes to Table 3 ............................................................................ 4
Added Figure 3, Renumbered Sequentially ................................... 6
Changes to Low Power Mode Section .......................................... 13
Added Latency from Touch to Response Section ....................... 13
Added Low Latency from Touch to Response Section .............. 13
Changes to Figure 60 and Figure 61 ............................................. 40
Changes to Figure 62 ...................................................................... 41
Added Exposed Pad Notation to Outline Dimensions .............. 68
5/11—Rev. B to Rev. C
Changes to Features Section ............................................................ 1
Changes to Ordering Guide ...........................................................70
Added Automotive Products Section ...........................................70
9/07—Revision 0: Initial Version
Rev. E | Page 3 of 70
AD7147
Data Sheet
SPECIFICATIONS
VCC = 2.6 V to 3.6 V, TA = −40oC to +85°C, unless otherwise noted.
Table 1.
Parameter
CAPACITANCE-TO-DIGITAL CONVERTER
Update Rate
Resolution
CINx Input Range
No Missing Codes
Min
Typ
Max
Unit
Test Conditions/Comments
8.73
17.46
34.9
9
18
36
16
±8
9.27
18.54
37.1
ms
ms
ms
Bits
pF
Bits
12 conversion stages, decimation = 64
12 conversion stages, decimation = 128
12 conversion stages, decimation = 256
16
CINx Input Leakage
Maximum Output Load
Total Unadjusted Error
Output Noise (Peak-to-Peak)
25
20
±20
12
7
3
1.1
0.8
0.5
20
0.32
Output Noise (RMS)
CSTRAY Offset Range
CSTRAY Offset Resolution
Low Power Mode Delay Accuracy
ACSHIELD
Frequency
Output Voltage
Short-Circuit Source Current
Short-Circuit Sink Current
Maximum Output Load
LOGIC INPUTS (SDI, SCLK, CS, SDA, GPIO)
VIH Input High Voltage
VIL Input Low Voltage
IIH Input High Current
IIL Input Low Current
Hysteresis
OPEN-DRAIN OUTPUTS (SCLK, SDA, INT)
VOL Output Low Voltage
IOH Output High Leakage Current
LOGIC OUTPUTS (SDO, GPIO)
VOL Output Low Voltage
VOH Output High Voltage
GPIO, SDO Floating State Leakage
Current
POWER
VCC
VDRIVE
ICC
4
250
0
VCC
10
10
150
0.7 × VDRIVE
0.4
−1
1
150
kHz
V
mA
mA
pF
V
V
µA
µA
mV
Capacitance load on CINx to ground
Decimation rate = 64
Decimation rate = 128
Decimation rate = 256
Decimation rate = 64
Decimation rate = 128
Decimation rate = 256
Percentage of 200 ms, 400 ms, 600 ms,
or 800 ms
Oscillating
Capacitance load on ACSHIELD to ground
VIN = VDRIVE
VIN = GND
0.4
±1
V
µA
ISINK = −1 mA
VOUT = VDRIVE
0.4
±1
V
V
µA
ISINK = 1 mA, VDRIVE = 1.65 V to 3.6 V
ISOURCE = 1 mA, VDRIVE = 1.65 V to 3.6 V
Pin three-state, leakage measured to
GND and VCC
0.9
15.5
3.6
3.6
1
21.5
V
V
mA
µA
2.3
7.5
µA
±0.1
VDRIVE − 0.6
2.6
1.65
nA
pF
%
Codes
Codes
Codes
Codes
Codes
Codes
pF
pF
%
Guaranteed by design, but not production
tested
3.3
Rev. E | Page 4 of 70
Serial interface operating voltage
In full power mode, VCC + VDRIVE
Low power mode, converter idle, VCC + VDRIVE,
decimation = 256
Full shutdown, VCC + VDRIVE
Data Sheet
AD7147
AVERAGE CURRENT SPECIFICATIONS
Table 2. Typical Average Current in Low Power Mode1
Low Power
Mode Delay
200 ms
400 ms
600 ms
800 ms
1
Decimation
Rate
64
128
256
64
128
256
64
128
256
64
128
256
1
20.83
25.3
34.11
18.17
20.43
24.9
17.28
18.79
21.79
16.84
17.97
20.23
2
24.18
31.92
46.99
19.86
23.79
31.53
18.41
21.04
26.25
17.69
19.66
23.59
3
27.52
38.45
59.51
21.55
27.12
38.06
19.54
23.28
30.67
18.53
21.35
26.93
Current Values of Conversion Stages (μA)
5
6
7
8
9
34.11 37.37 40.6
43.81
46.99
51.21 57.45 63.6
69.66
75.63
83.47 94.94 106.1
116.96 127.52
24.9
26.57 28.23
29.88
31.53
33.72 36.98 40.22
43.43
46.62
50.83 57.08 63.23
69.3
75.28
21.79 22.91 24.03
25.14
26.25
27.73 29.94 32.13
34.32
36.49
39.37 43.66 47.9
52.11
56.27
20.23 21.07 21.91
22.75
23.59
24.7
26.37 28.03
29.69
31.34
33.53 36.79 40.03
43.24
46.43
10
50.16
81.52
137.81
33.17
49.78
81.17
27.36
38.65
60.39
24.43
32.98
49.6
11
53.3
87.33
147.82
34.81
52.93
86.98
28.47
40.81
64.47
25.26
34.62
52.74
12
56.41
93.05
157.58
36.44
56.05
92.71
29.57
42.95
68.51
26.09
36.25
55.86
Current Values of Conversion Stages (μA)
5
6
7
8
9
44.16
48.12
52.06
55.97
59.85
64.97
72.55
80.02
87.37
94.61
104.09 117.97 131.45 144.53 157.25
32.95
34.99
37.01
39.03
41.04
43.71
47.68
51.62
55.53
59.41
64.54
72.12
79.6
86.96
94.2
29.17
30.53
31.89
33.25
34.61
36.41
39.1
41.78
44.44
47.09
50.6
55.82
60.98
66.09
71.15
27.26
28.29
29.32
30.34
31.36
32.72
34.76
36.79
38.8
40.81
43.48
47.46
51.4
55.31
59.19
10
63.69
101.74
169.61
43.04
63.26
101.34
35.96
49.72
76.15
32.38
42.81
63.04
11
67.51
108.77
181.63
45.03
67.08
108.37
37.31
52.34
81.1
33.4
44.81
66.86
12
71.29
115.69
193.33
47.02
70.87
115.3
38.66
54.95
86.01
34.42
46.79
70.66
4
30.82
44.87
71.66
23.23
30.43
44.5
20.67
25.51
35.04
19.38
23.03
30.24
VCC = 3.3 V, TA = 25°C, load = 50 pF.
Table 3. Maximum Average Current in Low Power Mode1
Low Power
Mode Delay
200 ms
400 ms
600 ms
800 ms
1
Decimation
Rate
64
128
256
64
128
256
64
128
256
64
128
256
1
27.96
33.41
44.16
24.74
27.49
32.95
23.66
25.5
29.17
23.12
24.5
27.26
2
32.06
41.49
59.85
26.8
31.59
41.04
25.04
28.25
34.61
24.16
26.57
31.36
3
36.12
49.44
75.05
28.86
35.66
49
26.42
30.99
40
25.19
28.63
35.44
4
40.15
57.26
89.79
30.91
39.7
56.83
27.79
33.71
45.33
26.23
30.68
39.47
VCC = 3.6 V, TA = −40°C to +85°C, load = 50 pF.
Rev. E | Page 5 of 70
AD7147
Data Sheet
SPI TIMING SPECIFICATIONS (AD7147)
TA = −40°C to +85°C, sample tested at 25°C to ensure compliance. VDRIVE = 1.65 V to 3.6 V, and VCC = 2.6 V to 3.6 V, unless otherwise
noted. All input signals are specified with tR = tF = 5 ns (10% to 90% of VCC) and timed from a voltage level of 1.6 V.
Table 4. SPI Timing Specifications
Parameter
fSCLK
t1
t2
t3
t4
t5
t6
t7
t8
Limit
5
5
20
20
15
15
20
16
15
Unit
MHz max
ns min
ns min
ns min
ns min
ns min
ns max
ns max
ns min
Description
SCLK frequency
CS falling edge to first SCLK falling edge
SCLK high pulse width
SCLK low pulse width
SDI setup time
SDI hold time
SDO access time after SCLK falling edge
CS rising edge to SDO high impedance
SCLK rising edge to CS high
SPI Timing Diagram
CS
t1
t2
1
SCLK
t8
t3
2
3
15
16
1
2
15
16
t4
t5
LSB
t6
SDO
MSB
Figure 2. SPI Detailed Timing Diagram
Rev. E | Page 6 of 70
t7
LSB
06663-002
SDI
MSB
Data Sheet
AD7147
I2C TIMING SPECIFICATIONS (AD7147-1)
TA = −40°C to +85°C, sample tested at 25°C to ensure compliance. VDRIVE = 1.65 V to 3.6 V, and VCC = 2.6 V to 3.6 V, unless otherwise
noted. All input signals timed from a voltage level of 1.6 V.
Table 5. I2C Timing Specifications1
Parameter
fSCLK
t1
t2
t3
t4
t5
t6
t7
t8
tR
tF
1
Limit
400
0.6
1.3
0.6
100
300
0.6
0.6
1.3
300
300
Unit
kHz max
μs min
μs min
μs min
ns min
ns min
μs min
μs min
μs min
ns max
ns max
Description
Start condition hold time, tHD; STA
Clock low period, tLOW
Clock high period, tHIGH
Data setup time, tSU; DAT
Data hold time, tHD; DAT
Stop condition setup time, tSU; STO
Start condition setup time, tSU; STA
Bus-free time between stop and start conditions, tBUF
Clock/data rise time
Clock/data fall time
Guaranteed by design, not production tested.
I2C Timing Diagram
tR
t2
tF
t1
SCLK
t3
t1
t5
t7
t6
t4
SDA
STOP START
START
STOP
Figure 3. I2C Detailed Timing Diagram
200µA
1.6V
CL
50pF
200µA
IOH
06663-004
TO OUTPUT
PIN
IOL
Figure 4. Load Circuit for Digital Output Timing Specifications
Rev. E | Page 7 of 70
06663-003
t8
AD7147
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 6.
Parameter
VCC to GND
Analog Input Voltage to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Input Current to Any Pin Except Supplies1
ESD Rating (Human Body Model)
Operating Temperature Range
Storage Temperature Range
Junction Temperature
LFCSP
Power Dissipation
θJA Thermal Impedance
IR Reflow Peak Temperature
Lead Temperature (Soldering 10 sec)
1
Rating
−0.3 V to +3.6 V
−0.3 V to VCC + 0.3 V
−0.3 V to VDRIVE + 0.3 V
−0.3 V to VDRIVE + 0.3 V
10 mA
2.5 kV
−40°C to +105°C
−65°C to +150°C
150°C
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION
450 mW
135.7°C/W
260°C (±0.5°C)
300°C
Transient currents of up to 100 mA do not cause SCR latch-up.
Rev. E | Page 8 of 70
Data Sheet
AD7147
PIN 1
INDICATOR
AD7147
TOP VIEW
(Not to Scale)
18
17
16
15
14
13
GPIO
INT
CS
SCLK
SDI
SDO
CIN6
CIN7
CIN8
CIN9
CIN10
CIN11
PIN 1
INDICATOR
AD7147-1
18
17
16
15
14
13
GPIO
INT
ADD1
SCLK
ADD0
SDA
7
8
9
10
11
12
TOP VIEW
(Not to Scale)
CIN12
ACSHIELD
BIAS
GND
VCC
VDRIVE
06663-005
CIN12
ACSHIELD
BIAS
GND
VCC
VDRIVE
1
2
3
4
5
6
06663-006
1
2
3
4
5
6
7
8
9
10
11
12
CIN6
CIN7
CIN8
CIN9
CIN10
CIN11
24
23
22
21
20
19
24
23
22
21
20
19
CIN5
CIN4
CIN3
CIN2
CIN1
CIN0
CIN5
CIN4
CIN3
CIN2
CIN1
CIN0
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
NOTES
1. THE EXPOSED PAD IS NOT CONNECTED INTERNALLY. FOR INCREASED
RELIABILITY OF THE SOLDER JOINTS AND MAXIMUM THERMAL CAPABILITY
IT IS RECOMMENDED THAT THE PAD BE SOLDERED TO THE GROUND PLANE.
NOTES
1. THE EXPOSED PAD IS NOT CONNECTED INTERNALLY. FOR INCREASED
RELIABILITY OF THE SOLDER JOINTS AND MAXIMUM THERMAL CAPABILITY
IT IS RECOMMENDED THAT THE PAD BE SOLDERED TO THE GROUND PLANE.
Figure 5. AD7147 Pin Configuration
Figure 6. AD7147-1 Pin Configuration
Table 7. Pin Function Descriptions
AD7147
1
2
3
4
5
6
7
8
9
10
11
12
13
N/A
14
N/A
15
16
N/A
17
18
19
20
21
22
23
24
Pin No.
AD7147-1
1
2
3
4
5
6
7
8
9
10
11
12
N/A
13
N/A
14
15
N/A
16
17
18
19
20
21
22
23
24
Mnemonic
CIN6
CIN7
CIN8
CIN9
CIN10
CIN11
CIN12
ACSHIELD
BIAS
GND
VCC
VDRIVE
SDO
SDA
SDI
ADD0
SCLK
CS
ADD1
INT
GPIO
CIN0
CIN1
CIN2
CIN3
CIN4
CIN5
Description
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
CDC Active Shield Output. Connect to external shield or plane.
Bias Node for Internal Circuitry. Requires 100 nF capacitor to ground.
Ground Reference Point for All Circuitry.
Supply Voltage.
Serial Interface Operating Voltage Supply.
SPI Serial Data Output.
I2C Serial Data Input/Output. SDA requires pull-up resistor.
SPI Serial Data Input.
I2C Address Bit 0.
Clock Input for Serial Interface.
SPI Chip Select Signal.
I2C Address Bit 1.
General-Purpose Open-Drain Interrupt Output. Programmable polarity; requires pull-up resistor.
Programmable GPIO.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Capacitance Sensor Input.
Rev. E | Page 9 of 70
AD7147
Data Sheet
TYPICAL PERFORMANCE CHARACTERISTICS
935
70
915
60
895
200ms
50
875
ICC (μA)
ICC (µA)
DECIMATION = 64
DECIMATION = 128
DECIMATION = 256
855
40
400ms
600ms
30
815
10
795
2.6
06663-007
20
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
06663-060
800ms
835
0
2.5
3.7
3.3
3.1
2.9
2.7
VCC (V)
3.5
3.7
VCC (V)
Figure 7. Supply Current vs. Supply Voltage
Figure 10. Low Power Supply Current vs. Supply Voltage,
Decimation Rate = 64
180
2.5
200ms
160
2.0
140
100
ICC (µA)
ICC (μA)
120
400ms
80
600ms
1.5
1.0
60
800ms
40
0
2.5
2.7
2.9
3.1
3.3
3.5
0
2.7
3.7
06663-010
06663-061
0.5
20
2.8
2.9
3.0
VCC (V)
3.1
3.2
3.3
3.4
3.5
3.6
VCC (V)
Figure 8. Low Power Supply Current vs. Supply Voltage,
Decimation Rate = 256
Figure 11. Shutdown Supply Current vs. Supply Voltage
0.12
1150
0.10
200ms
1100
ICC (µA)
0.06
400ms
600ms
1050
1000
0.04
800ms
0
2.5
2.7
2.9
3.1
3.3
3.5
3.7
06663-062
950
0.02
06663-009
ICC (mA)
0.08
900
0
VCC (V)
100
200
300
400
500
ACSHIELD CAPACITIVE LOAD (pF)
Figure 9. Low Power Supply Current vs. Supply Voltage,
Decimation Rate = 128
Figure 12. Supply Current vs. Capacitive Load on ACSHIELD
Rev. E | Page 10 of 70
Data Sheet
AD7147
160
58000
56000
140
54000
75mV
100mV
125mV
150mV
175mV
200mV
CDC NOISE p-p (LSB)
120
52000
50000
48000
46000
100
80
60
40
44000
SINE WAVE FREQUENCY (Hz)
Figure 13. Output Code vs. Capacitive Load on ACSHIELD
1640000
409600
819200
102400
204800
25600
51200
6400
12800
ACSHIELD CAPACITIVE LOAD (pF)
1600
0
500
3200
400
400
300
800
200
200
100
25
0
50
40000
06663-064
20
06663-063
42000
100
CDC CODE (d)
25mV
50mV
Figure 16. Power Supply Sine Wave Rejection, VCC = 3.6 V
960
120
25mV
50mV
940
3.6V
75mV
100mV
125mV
150mV
175mV
200mV
100
CDC NOISE p-p (LSB)
920
900
ICC (µA)
3.3V
880
860
840
820
80
60
40
2.6V
SQUARE WAVE FREQUENCY (Hz)
Figure 14. Supply Current vs. Temperature
Figure 17. Power Supply Square Wave Rejection, VCC = 3.6 V
35
10
30
INPUT CAPACITANCE (pF)
12
6
3.6V
3.3V
2.6V
2
–25
–5
15
35
55
75
95
115
20
15
10
06663-016
0
–45
25
5
06663-014
ICC (µA)
8
4
1640000
819200
409600
204800
102400
51200
25600
TEMPERATURE (°C)
6400
0
120
12800
100
3200
80
1600
60
800
40
400
20
200
0
100
–20
50
–40
25
780
–60
06663-065
06663-013
20
800
0
135
0
TEMPERATURE (°C)
10000
20000
30000
40000
50000
CDC OUTPUT CODE
Figure 15. Shutdown Supply Current vs. Temperature
Figure 18. CDC Linearity, VCC = 3.3 V
Rev. E | Page 11 of 70
60000
AD7147
Data Sheet
THEORY OF OPERATION
The AD7147 interfaces with up to 13 external capacitance
sensors. These sensors can be arranged as buttons, scroll bars,
or wheels, or as a combination of sensor types. The external
sensors consist of an electrode on a single- or multiple-layer
PCB that interfaces directly to the AD7147.
require low power operation to provide the user with significant
power savings and full functionality.
The AD7147 has an interrupt output, INT, to indicate when
new data has been placed into the registers. INT is used to
interrupt the host on sensor activation. The AD7147 operates
from a 2.6 V to 3.6 V supply and is available in a 24-lead, 4 mm ×
4 mm LFCSP.
CAPACITANCE SENSING THEORY
The AD7147 measures capacitance changes from single electrode
sensors. The sensor electrode on the PCB comprises one plate
of a virtual capacitor. The other plate of the capacitor is the user’s
finger, which is grounded with respect to the sensor input.
The AD7147 first outputs an excitation signal to charge the plate
of the capacitor. When the user comes close to the sensor, the
virtual capacitor is formed, with the user acting as the second
capacitor plate.
The AD7147 can be set up to implement any set of input sensors
by programming the on-chip registers. The registers
can also be programmed to control features such as averaging,
offsets, and gains for each of the external sensors. There is an
on-chip sequencer that controls how each of the capacitance
inputs is polled.
PLASTIC COVER
SENSOR PCB
The AD7147 requires a companion algorithm that runs on the
host or another microcontroller to implement high resolution
sensor functions, such as scroll bars or wheels. However, no
companion algorithm is required to implement buttons. Button
sensors are implemented on chip, entirely in digital logic.
The AD7147 can be programmed to operate in either full power
mode or low power automatic wake-up mode. The automatic
wake-up mode is particularly suited for portable devices that
MUX
The AD7147 has on-chip digital logic and 528 words of RAM
that are used for environmental compensation. The effects of
humidity, temperature, and other environmental factors can
affect the operation of capacitance sensors. Transparent to the
user, the AD7147 performs continuous calibration to compensate for these effects, allowing the AD7147 to consistently
provide error-free results.
AD7147
Σ-Δ
ADC
16-BIT
DATA
EXCITATION
SIGNAL
250kHz
06663-017
The AD7147 and AD7147-1 are CDCs with on-chip environmental compensation. They are intended for use in portable
systems requiring high resolution user input. The internal
circuitry consists of a 16-bit, ∑-∆ converter that can change a
capacitive input signal into a digital value. There are 13 input
pins, CIN0 to CIN12, on the AD7147 or AD7147-1. A switch
matrix routes the input signals to the CDC. The result of each
capacitance-to-digital conversion is stored in on-chip registers.
The host subsequently reads the results over the serial interface.
The AD7147 has an SPI interface, and the AD7147-1 has an I2C
interface, ensuring that the parts are compatible with a wide
range of host processors. AD7147 refers to both the AD7147 and
AD7147-1, unless otherwise noted, from this point forward in
this data sheet.
Figure 19. Capacitance-Sensing Method
A square wave excitation signal is applied to CINx during
the conversion, and the modulator continuously samples the
charge going through CINx. The output of the modulator is
processed via a digital filter, and the resulting digital data is
stored in the CDC_RESULT_Sx registers for each conversion
stage, at Address 0x00B to Address 0x016.
Rev. E | Page 12 of 70
Data Sheet
AD7147
Registering a Sensor Activation
Complete Solution for Capacitance Sensing
When a user approaches a sensor, the total capacitance associated
with that sensor changes and is measured by the AD7147. If
the change causes a set threshold to be exceeded, the AD7147
interprets this as a sensor activation.
Analog Devices, Inc., provides a complete solution for
capacitance sensing. The two main elements to the solution are
the sensor PCB and the AD7147.
If the application requires high resolution sensors such as scroll
bars or wheels, software is required that runs on the host
processor. The memory requirements for the host depend on
the sensor and are typically 10 kB of code and 600 bytes of data
memory, depending on the sensor type.
SENSOR PCB
AD7147
STAGEx_HIGH_THRESHOLD
SPI OR I2C
HOST PROCESSOR
1 MIPS
10kB ROM
600 BYTES RAM
CDC_RESULT_Sx
AMBIENT OR
NO-TOUCH VALUE
Figure 21. Three-Part Capacitance Sensing Solution
STAGEx_LOW_THRESHOLD
06663-018
CDC OUTPUT CODES
SENSOR ACTIVE (A)
06663-019
On-chip threshold limits are used to determine when a sensor
activation occurs. Figure 20 shows the change in CDC_RESULT_Sx
when a user activates a sensor. The sensor is deemed to be active
only when the value of CDC_RESULT_Sx is either greater than the
value of STAGEx_HIGH_THRESHOLD or less than the value
of STAGEx_LOW_THRESHOLD.
SENSOR ACTIVE (B)
Analog Devices supplies the sensor PCB footprint design
libraries to the customer and supplies any necessary software on
an open source basis.
BIAS PIN
Figure 20. Sensor Activation Thresholds
In Figure 20, two sensor activations are shown. Sensor Active A
occurs when a sensor is connected to the positive input of the
converter. In this case, when a user activates the sensor, there is an
increase in CDC code, and the value of CDC_RESULT_Sx exceeds
that of STAGEx_HIGH_THRESHOLD. Sensor Active B occurs
when the sensor is connected to the negative input of the converter.
In this case, when a user activates the sensor, there is a decrease
in CDC code, and the value of CDC_RESULT_Sx becomes less
than the value of STAGEx_LOW_THRESHOLD.
For each conversion stage, the STAGEx_HIGH_THRESHOLD
and STAGEx_LOW_THRESHOLD registers are in Register
Bank 3. The values in these registers are updated automatically
by the AD7147 due to its environmental calibration and
adaptive threshold logic.
At power-up, the values in the STAGEx_HIGH_THRESHOLD
and STAGEx_LOW_THRESHOLD registers are the same as those
in the STAGEx_OFFSET_HIGH and STAGEx_OFFSET_LOW
registers in Bank 2. The user must program the STAGEx_OFFSET
_HIGH and STAGEx_OFFSET_LOW registers on device powerup. See the Environmental Calibration section of the data sheet
for more information.
This pin is connected internally to a bias node of the AD7147.
To ensure correct operation of the AD7147, connect a 100 nF
capacitor between the BIAS pin and ground. The voltage seen at
the BIAS pin is VCC/2.
OPERATING MODES
The AD7147 has three operating modes. Full power mode, where
the device is always fully powered, is suited for applications where
power is not a concern (for example, game consoles that have an
ac power supply). Low power mode, where the part automatically
powers down when no sensor is active, is tailored to provide
significant power savings compared with full power mode and
is suited for mobile applications, where power must be
conserved. In shutdown mode, the part shuts down completely.
The POWER_MODE bits (Bit 0 and Bit 1) of the control
register set the operating mode on the AD7147. The control
register is at Address 0x000. Table 8 shows the POWER_MODE
settings for each operating mode. To put the AD7147 into
shutdown mode, set the POWER_MODE bits to either 01 or 11.
Table 8. POWER_MODE Settings
POWER_MODE Bits
00
01
10
11
Operating Mode
Full power mode
Shutdown mode
Low power mode
Shutdown mode
The power-on default setting of the POWER_MODE bits is 00,
full power mode.
Rev. E | Page 13 of 70
AD7147
Data Sheet
Full Power Mode
In full power mode, all sections of the AD7147 remain fully
powered and converting at all times. While a sensor is being
touched, the AD7147 processes the sensor data. If no sensor is
touched, the AD7147 measures the ambient capacitance level
and uses this data for the on-chip compensation routines. In full
power mode, the AD7147 converts at a constant rate. See the
CDC Conversion Sequence Time section for more information.
Low Power Mode
When AD7147 is in low power mode, the POWER_MODE bits
are set to 10 upon device initialization. If the external sensors
are not touched, the AD7147 reduces its conversion frequency,
thereby greatly reducing its power consumption. The part remains
in a reduced power state while the sensors are not touched. The
AD7147 performs a conversion after a delay defined by the
LP_CONV_DELAY bits, and it uses this data to update the
compensation logic and check if the sensors are active. The
LP_CONV_DELAY bits set the delay between conversions to
200 ms, 400 ms, 600 ms, or 800 ms.
In low power mode, the total current consumption of the AD7147
is an average of the current used during a conversion and the
current used while the AD7147 is waiting for the next conversion
to begin. For example, when LP_CONV_DELAY is 400 ms, the
AD7147 typically uses 0.85 mA of current for 36 ms and 14 μA
of current for 400 ms during the conversion interval. (Note that
these conversion timings can be altered through the register
settings. See the CDC Conversion Sequence Time section for
more information.)
The time for the AD7147 to transition from a full power state to
a reduced power state after the user stops touching the external
sensors is configurable. The PWR_DOWN_TIMEOUT bits (in
the Ambient Compensation Control 0 (AMB_COMP_CTRL0)
Register at Address 0x002) control the time delay before the
AD7147 transitions to the reduced power state after the user
stops touching the sensors.
Latency from Touch to Response
In low power mode, the AD7147 remains in a low power state
until any one of the external sensors are touched. When a
sensor is touched, the AD7147 begins a conversion sequence
every 36 ms to read back data from the sensors. This means that
the latency between the user touching the sensor, and the AD7147
responding, is a maximum of LP_CONV_DELAY ms.
Low Latency from Touch to Response
In low power mode, the AD7147P model remains in a low power
state until proximity is detected on any one of the external sensors.
When proximity is detected, the AD714P begins a conversion
sequence every 36 ms, or 18 ms, or 9 ms to read back data from the
sensors. The latency between first touch and the AD7147P
responding is much reduced, compared to the AD7147, because
the part is already in a full power state by the time the user has
touched the sensor.
AD7147P SETUP
AND INITIALIZATION
POWER_MODE = 10
AD7147 SETUP
AND INITIALIZATION
POWER_MODE = 10
ANY
SENSOR
TOUCHED?
CONVERSION SEQUENCE
EVERY LP_CONV_DELAY
UPDATE COMPENSATION
LOGIC DATA PATH
NO
YES
CONVERSION SEQUENCE
EVERY 9/18/36ms FOR
SENSOR READBACK
YES
USER IN
PROXIMITY
TO SENSOR?
CONVERSION SEQUENCE
EVERY LP_CONV_DELAY
UPDATE COMPENSATION
LOGIC DATA PATH
YES
CONVERSION SEQUENCE
EVERY 9/18/36ms FOR
SENSOR READBACK
YES
ANY SENSOR
TOUCHED?
NO
06663-020
NO
PROXIMITY TIMER TIMEOUT
COUNTDOWN
USER IN
PROXIMITY
TO SENSOR?
PROXIMITY TIMER TIMEOUT
COUNTDOWN
Figure 23. Low Power Mode Operation, AD7147P
Figure 22. Low Power Mode Operation, AD7147
Rev. E | Page 14 of 70
06663-066
NO
Data Sheet
AD7147
CAPACITIANCE-TO-DIGITAL CONVERTER
from midscale, decrease the POS_AFE_OFFSET or
NEG_AFE_OFFSET value by 1.
The capacitance-to-digital converter on the AD7147 has a Σ-Δ
architecture with 16-bit resolution. There are 13 possible inputs to
the CDC that are connected to the input of the converter through a
switch matrix. The sampling frequency of the CDC is 250 kHz.
The goal is to ensure that the CDC_RESULT_Sx is as close
to midscale as possible. This process is only required once
during the initial capacitance sensor characterization.
OVERSAMPLING THE CDC OUTPUT
The decimation rate, or oversampling ratio, is determined by
Bits[9:8] of the power control (PWR_CONTROL) register
(Address 0x000), as listed in Table 9.
+DAC
(20pF RANGE)
Table 9. CDC Decimation Rate
Decimation Rate
256
128
64
64
The decimation process on the AD7147 is an averaging process,
where a number of samples are taken and the averaged result is
output. Due to the architecture of the digital filter employed, the
number of samples taken (per stage) is equal to 3× the decimation
rate. So 3 × 256 or 3 × 128 samples are averaged to obtain each
stage result.
The decimation process reduces the amount of noise present in
the final CDC result. However, the higher the decimation rate,
the lower the output rate per stage; therefore, there is a trade-off
possible between the amount of noise in the signal and the
speed of sampling.
CAPACITANCE SENSOR OFFSET CONTROL
There are two programmable DACs on board the AD7147 to null
the effect of any stray capacitances on the CDC measurement.
These offsets are due to stray capacitance to ground.
A simplified block diagram in Figure 24 shows how to apply the
STAGEx_AFE_OFFSET registers to null the offsets. The 6-bit
POS_AFE_OFFSET and NEG_AFE_OFFSET bits program the
offset DAC to provide 0.32 pF resolution offset adjustment over
a range of 20 pF.
The best practice is to ensure that the CDC output for any stage
is approximately equal to midscale (~32,700) when all sensors
are inactive. To correctly offset the stray capacitance to ground for
each stage, use the following procedure:
1.
Read back the CDC value from the CDC_RESULT_Sx register.
2.
If this value is not close to midscale, increase the value of
POS_AFE_OFFSET or NEG_AFE_OFFSET (depending
on if the CINx input is connected to the positive or negative
input of the converter) by 1. The CINx connections are
determined by the STAGEx_CONNECTION registers.
3.
If the CDC value in CDC_RESULT_Sx is now closer
to midscale, repeat Step 2. If the CDC value is further
POS_AFE_OFFSET
POS_AFE_OFFSET_SWAP BIT
CINx
+
16-BIT
_ CDC
16
NEG_AFE_OFFSET_SWAP BIT
–DAC
(20pF RANGE)
6
NEG_AFE_OFFSET
CINx_CONNECTION_SETUP
06663-021
Decimation Bits
00
01
10
11
CDC Output Rate
Per Stage (ms)
3.072
1.536
0.768
0.768
6
Figure 24. Analog Front-End Offset Control
CONVERSION SEQUENCER
The AD7147 has an on-chip sequencer to implement conversion
control for the input channels. Up to 12 conversion stages can be
performed in one sequence. Each of the 12 conversions stages can
measure the input from a different sensor. By using the Bank 2
registers, each stage can be uniquely configured to support multiple
capacitance sensor interface requirements. For example, a slider
sensor can be assigned to STAGE1 through STAGE8, with a
button sensor assigned to STAGE0. For each conversion stage,
the input mux that connects the CINx inputs to the converter
can have a unique setting.
The AD7147 on-chip sequence controller provides conversion
control, beginning with STAGE0. Figure 25 shows a block diagram
of the CDC conversion stages and CINx inputs. A conversion
sequence is defined as a sequence of CDC conversions starting
at STAGE0 and ending at the stage determined by the value
programmed in the SEQUENCE_STAGE_NUM bits. Depending
on the number and type of capacitance sensors that are used, not all
conversion stages are required. Use the SEQUENCE_STAGE_NUM
bits to set the number of conversions in one sequence. This number
depends on the sensor interface requirements. For example, the
register should be set to 5 if the CINx inputs are mapped to only six
conversion stages. In addition, the STAGE_CAL_EN register
should be set according to the number of stages that are used.
The number of required conversion stages depends solely on
the number of sensors attached to the AD7147. Figure 26 shows
how many conversion stages are required for each sensor and
how many inputs to the AD7147 each sensor requires.
Rev. E | Page 15 of 70
AD7147
Data Sheet
A wheel sensor requires eight stages, whereas a slider requires two
stages. The result from each stage is used by the host software to
determine the user’s position on the slider or wheel. The algorithms
that perform this process are available from Analog Devices and are
free of charge, but require signing a software license.
A button sensor generally requires one sequencer stage; this is
shown in Figure 26 as B1. However, it is possible to configure
two button sensors to operate differentially for one conversion
stage. Only one button can be activated at a time; pressing both
buttons simultaneously results in neither button being activated.
The configuration with two button sensors operating differentially
requires one conversion stage and is shown in Figure 26, with
B2 and B3 representing the differentially configured button sensors.
STAGE11
STAGE10
STAGE9
STAGE8
STAGE7
STAGE6
STAGE5
STAGE4
STAGE3
STAGE2
STAGE1
STAGE0
CIN0
CIN1
CIN6
CIN7
CIN8
CIN9
SEQ
UEN
CE
CIN5
Σ-∆
16-BIT
ADC
I ON
CIN4
CO
NVE
RS
CIN3
SWITCH MATRIX
CIN2
CIN10
06663-022
CIN11
CIN12
Figure 25. CDC Conversion Stages
AD7147
SEQUENCER
STAGE0
+
CDC
–
STAGE1
+
CDC
–
STAGE2
+ CDC
–
SEQUENCER
B1
STAGE8
+ CDC
–
B2
STAGE9
+ CDC
–
B3
STAGE3
+ CDC
–
STAGE4
+ CDC
–
SEQUENCER
STAGE5
+
CDC
–
STAGE10
+ CDC
–
AD7147
SLIDER
STAGE6
+ CDC
–
STAGE7
+ CDC
–
Figure 26. Sequencer Setup for Sensors
Rev. E | Page 16 of 70
STAGE11
+ CDC
–
06663-023
SCROLL
WHEEL
AD7147
BUTTONS
Data Sheet
AD7147
CDC CONVERSION SEQUENCE TIME
Table 10. CDC Conversion Times for Full Power Mode
Conversion Time (ms)
Decimation = 128
1.536
3.072
4.608
6.144
7.68
9.216
10.752
12.288
13.824
15.36
16.896
18.432
Decimation = 64
0.768
1.536
2.304
3.072
3.84
4.608
5.376
6.144
6.912
7.68
8.448
9.216
The time required for the CDC to complete the measurement of
all 12 stages is defined as the CDC conversion sequence time. The
SEQUENCE_STAGE_NUM and DECIMATION bits determine
the conversion time, as listed in Table 10.
For example, if the device is operated with a decimation rate
of 128 and the SEQUENCE_STAGE_NUM bit is set to 5 for the
conversion of six stages in a sequence, the conversion sequence
time is 9.216 ms.
Full Power Mode CDC Conversion Sequence Time
The full power mode CDC conversion sequence time for all
12 stages is set by configuring the SEQUENCE_STAGE_NUM
and DECIMATION bits as outlined in Table 10.
Figure 27 shows a simplified timing diagram of the full power
mode CDC conversion time. The full power mode CDC conversion time (tCONV_FP) is set using the values shown in Table 10.
the AD7147 automatically wakes up, performing a conversion
every 800 ms.
Table 11. LP_CONV_DELAY Settings
LP_CONV_DELAY Bits
00
01
10
11
tCONV_LP
tCONV_FP
CDC
CONVERSION
CONVERSION
SEQUENCE N
LP_CONV_DELAY
CONVERSION
SEQUENCE N + 1
Figure 28. Low Power Mode CDC Conversion Sequence Time
CONVERSION
CONVERSION
SEQUENCE N + 1 SEQUENCE N + 2
06663-024
CONVERSION
SEQUENCE N
Delay Between Conversions (ms)
200
400
600
800
Figure 28 shows a simplified timing example of the low power
mode CDC conversion time. As shown, the low power mode CDC
conversion time is set by tCONV_FP and the LP_CONV_DELAY bits.
tCONV_FP
CDC
CONVERSION
Decimation = 256
3.072
6.144
9.216
12.288
15.36
18.432
21.504
24.576
27.648
30.72
33.792
36.864
06663-025
SEQUENCE_STAGE_NUM
0
1
2
3
4
5
6
7
8
9
10
11
Figure 27. Full Power Mode CDC Conversion Sequence Time
Low Power Mode CDC Conversion Sequence Time
with Delay
The frequency of each CDC conversion while operating in the
low power automatic wake-up mode is controlled by using the
LP_CONV_DELAY bits located at Address 0x000[3:2] in
addition to the registers listed in Table 10. This feature provides
some flexibility for optimizing the tradeoff between the conversion
time needed to meet system requirements and the power
consumption of the AD7147.
CDC CONVERSION RESULTS
Certain high resolution sensors require the host to read back the
CDC conversion results for processing. The registers required
for host processing are located in the Bank 3 registers. The host
processes the data read back from these registers using a software
algorithm in order to determine position information.
In addition to the results registers in the Bank 3 registers, the
AD7147 provides the 16-bit CDC output data directly, starting
at Address 0x00B of Bank 1. Reading back the CDC 16-bit
conversion data register allows for customer-specific application
data processing.
For example, maximum power savings is achieved when the
LP_CONV_DELAY bits are set to 11. With a setting of 11,
Rev. E | Page 17 of 70
AD7147
Data Sheet
CAPACITANCE SENSOR INPUT CONFIGURATION
Each input connection from the external capacitance sensors to
the converter of the AD7147 can be uniquely configured by
using the registers in Bank 2 (see Table 38). These registers are
used to configure the input pin connection setups, sensor offsets,
sensor sensitivities, and sensor limits for each stage. Each sensor
can be individually optimized. For example, a button sensor
connected to STAGE0 can have different sensitivity and offset
values than a button with another function that is connected to a
different stage.
CINx INPUT MULTIPLEXER SETUP
Table 34 and Table 35 list the available options for the
CINx_CONNECTION_SETUP bits when the sensor input
pins are connected to the CDC.
The AD7147 has an on-chip multiplexer that routes the input
signals from each CINx pin to the input of the converter. Each
input pin can be tied to either the negative or positive input of
the CDC, or it can be left floating. Each input can also be
internally connected to the BIAS signal to help prevent cross
coupling. If an input is not used, always connect it to the BIAS.
Connecting a CINx input pin to the positive CDC input results
in an increase in CDC output code when the corresponding
sensor is activated. Connecting a CINx input pin to the negative
CDC input results in a decrease in CDC output code when the
corresponding sensor is activated.
The AD7147 performs a sequence of 12 conversions. The multiplexer can have different settings for each of the 12 conversions.
For example, CIN0 is connected to the negative CDC input for
conversion STAGE1, left floating for conversion STAGE1, and
so on, for all 12 conversion stages.
For each CINx input for each conversion stage, two bits control
how the input is connected to the converter, as shown in Figure 29.
Examples
To connect CIN3 to the positive CDC input on Stage 0 use the
following setting:
STAGE0_CONNECTION[6:0] = 0xFFBF
STAGE0_CONNECTION[12:7] = 0x2FFF
CIN CONNECTION SETUP BITS
STAGE5_CONNECTION[6:0] = 0xFFFE
STAGE5_CONNECTION[12:7] = 0x37FF
SINGLE-ENDED CONNECTIONS TO THE CDC
A single-ended connection to the CDC is defined as one CINx
input connected to either the positive or negative CDC input
for one conversion stage. A differential connection to the CDC is
defined as one CINx input connected to the positive CDC input
and a second CINx input connected to the negative input of the
CDC for one conversion stage.
For any stage, if a single-ended connection to the CDC is made
in that stage, the SE_CONNECTION_SETUP bits (Bits[13:12] in
the STAGEx_CONNECTION[12:7] register) should be applied as
follows:
•
•
•
•
SE_CONNECTION_SETUP = 00: do not use.
SE_CONNECTION_SETUP = 01: single-ended connection.
For this stage, there is one CINx connected to the positive
CDC input.
SE_CONNECTION_SETUP = 10: single-ended connection.
For this stage, there is one CINx connected to the negative
CDC input.
SE_CONNECTION_SETUP = 11: differential connection.
For this stage, there is one CINx connected to the nega
tive CDC input and one CINx connected to the positive
CDC input.
These bits ensure that during a single-ended connection to the
CDC, the input paths to both CDC terminals are matched,
which in turn improves the power-supply rejection of the
converter measurement.
These bits should be applied in addition to setting the other bits
in the STAGEx_CONNECTION registers, as outlined in the
CINx Input Multiplexer Setup section.
If more than one CINx input is connected to either the positive
or negative input of the converter for the same conversion, set
SE_CONNECTION_SETUP to 11. For example, if CIN0 and
CIN3 are connected to the positive input of the CDC, set
SE_CONNECTION_SETUP to 11.
CIN SETTING
00
CINx FLOATING
01
CINx CONNECTED TO
NEGATIVE CDC INPUT
+
10
CINx CONNECTED TO
POSITIVE CDC INPUT
–
11
CINx CONNECTED TO
BIAS
CDC
Figure 29. Input Mux Configuration Options
Rev. E | Page 18 of 70
06663-026
CIN0
CIN1
CIN2
CIN3
CIN4
CIN5
CIN6
CIN7
CIN8
CIN9
CIN10
CIN11
CIN12
To connect CIN0 to the positive CDC input and CIN12 to the
negative CIN input on Stage 5 use the following settings:
Data Sheet
AD7147
NONCONTACT PROXIMITY DETECTION
The AD7147 internal signal processing continuously monitors
all capacitance sensors for noncontact proximity detection. This
feature provides the ability to detect when a user is approaching
a sensor, at which time all internal calibration is immediately
disabled while the AD7147 is automatically configured to detect
a valid contact.
The proximity control register bits are described in Table 12. The
FP_PROXIMITY_CNT and LP_PROXIMITY_CNT register
bits control the length of the calibration disable period after
the user stops touching the sensor and is not in close proximity
to the sensor during full or low power mode. The calibration is
disabled during this period and then enabled again. Figure 30
and Figure 31 show examples of how these registers are used to set
the calibration disable periods for the full and low power modes.
by the PROXIMITY_RECAL_LVL bits for a set period of time
known as the recalibration timeout. In full power mode, the recalibration timeout is controlled by FP_PROXIMITY_RECAL; in
low power mode, by LP_PROXMTY_RECAL.
The recalibration timeout in full power mode is the value of
the FP_PROXIMITY_RECAL multiplied by the time for one
conversion sequence in full power mode. The recalibration timeout in low power mode is the value of the LP_PROXIMITY_
RECAL multiplied by the time for one conversion sequence in
low power mode.
The calibration disable period in full power mode is the value
of the FP_PROXIMITY_CNT multiplied by 16 multiplied by
the time for one conversion sequence in full power mode. The
calibration disable period in low power mode is the value of the
LP_PROXIMITY_CNT multiplied by 4 multiplied by the time
for one conversion sequence in low power mode.
Figure 32 and Figure 33 show examples of how the
FP_PROXIMITY_RECAL and LP_PROXIMITY_RECAL
register bits control the timeout period before a recalibration
while operating in the full and low power modes. In these
examples, a user approaches a sensor and then leaves, but the
proximity detection remains active. The measured CDC value
exceeds the stored ambient value by the amount set in the
PROXIMITY_RECAL_LVL bits for the entire timeout period.
The sensor is automatically recalibrated at the end of the
timeout period.
RECALIBRATION
PROXIMITY SENSITIVITY
In certain situations (for example, when a user hovers over a
sensor for a long time), the proximity flag can be set for a long
period. The environmental calibration on the AD7147 is suspended while proximity is detected, but changes may occur
to the ambient capacitance level during the proximity event.
This means that the ambient value stored on the AD7147 no
longer represents the actual ambient value. In this case, even
when the user is not in close proximity to the sensor, the proximity flag may still be set. This situation can occur if the user
interaction creates some moisture on the sensor, causing the
new sensor ambient value to be different from the expected
value. In this situation, the AD7147 automatically forces a
recalibration internally. This ensures that the ambient values
are recalibrated, regardless of how long the user hovers over
the sensor. A recalibration ensures maximum AD7147 sensor
performance.
The fast filter in Figure 34 is used to detect when someone is close
to the sensor (proximity). Two conditions, detected by Comparator 1 and Comparator 2, set the internal proximity detection
signal: Comparator 1 detects when a user is approaching or
leaving a sensor, and Comparator 2 detects when a user hovers
over a sensor or approaches a sensor very slowly.
The AD7147 recalibrates automatically when the measured CDC
value exceeds the stored ambient value by an amount determined
The sensitivity of Comparator 1 is controlled by the
PROXIMITY_DETECTION_RATE bits. For example, if
PROXIMITY_DETECTION_RATE is set to 4, the Proximity 1
signal is set when the absolute difference between WORD1 and
WORD3 exceeds (4 × 16) LSB codes.
The PROXIMITY_RECAL_LVL bits (Address 0x003) control
the sensitivity of Comparator 2. For example, if PROXIMITY_
RECAL_LVL is set to 75, the Proximity 2 signal is set when the
absolute difference between the fast filter average value and the
ambient value exceeds (75 × 16) LSB codes.
Rev. E | Page 19 of 70
AD7147
Data Sheet
Table 12. Proximity Control Registers (See Figure 34)
Bit Name
FP_PROXIMITY_CNT
LP_PROXIMITY_CNT
FP_PROXIMITY_RECAL
LP_PROXIMITY_RECAL
PROXIMITY_RECAL_LVL
Length
(Bits)
4
4
8
6
8
Register Address
0x002[7:4]
0x002[11:8]
0x004[9:0]
0x004[15:10]
0x003[7:0]
PROXIMITY_DETECTION_RATE
6
0x003[13:8]
USER APPROACHES
SENSOR
Description
Calibration disable time in full power mode.
Calibration disable time in low power mode.
Full power mode proximity recalibration time.
Low power mode proximity recalibration time.
Proximity recalibration level. This value multiplied by 16 controls the
sensitivity of Comparator 2 (see Figure 34).
Proximity detection rate. This value multiplied by 16 controls the
sensitivity of Comparator 1 (see Figure 34).
USER LEAVES
SENSOR AREA
tCONV_FP
CDC CONVERSION
SEQUENCE
(INTERNAL)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
tCALDIS
CALIBRATION
(INTERNAL)
CALIBRATION DISABLED
CALIBRATION ENABLED
06663-027
PROXIMITY
DETECTION
(INTERNAL)
Figure 30. Example of Full Power Mode Proximity Detection (FP_PROXIMITY_CNT = 1)
USER APPROACHES
SENSOR
USER LEAVES
SENSOR AREA
tCONV_LP
CDC CONVERSION
SEQUENCE
(INTERNAL)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
tCALDIS
PROXIMITY
DETECTION
(INTERNAL)
CALIBRATION DISABLED
CALIBRATION ENABLED
NOTES
1. SEQUENCE CONVERSION TIME tCONV_LP = tCONV_FP + LP_CONV_DELAY.
2. PROXIMITY IS SET WHEN USER APPROACHES THE SENSOR, AT WHICH TIME THE INTERNAL CALIBRATION IS DISABLED.
3. tCALDIS = (tCONV_LP × LP_PROXIMITY_CNT × 4).
Figure 31. Example of Low Power Mode Proximity Detection (LP_PROXIMITY_CNT = 4)
Rev. E | Page 20 of 70
06663-028
CALIBRATION
(INTERNAL)
Data Sheet
AD7147
USER APPROACHES
SENSOR
tRECAL
MEASURED CDC VALUE > STORED AMBIENT
BY PROXIMITY_RECAL _LVL
USER LEAVES
SENSOR AREA
tCONV_FP
16
CDC CONVERSION
SEQUENCE
(INTERNAL)
30
70
tCALDIS
PROXIMITY
DETECTION
(INTERNAL)
CALIBRATION
(INTERNAL)
CALIBRATION DISABLED
RECALIBRATION TIMEOUT
CALIBRATION ENABLED
tRECAL_TIMEOUT
RECALIBRATION
COUNTER
(INTERNAL)
06663-029
NOTES
1. SEQUENCE CONVERSION TIME tCONV_FP (SEE TABLE 10).
2. tCALDIS = tCONV_FP × FP_PROXIMITY_CNT × 16.
3. tRECAL_TIMEOUT = tCONV_FP × FP_PROXIMITY_RECAL.
4. tRECAL = 2 × tCONV_FP .
Figure 32. Example of Full Power Mode Proximity Detection with Forced Recalibration (FP_PROXIMITY_CNT = 1 and FP_PROXIMITY_RECAL = 40)
USER APPROACHES
SENSOR
tRECAL
MEASURED CDC VALUE > STORED AMBIENT
BY PROXIMITY_RECAL _LVL
USER LEAVES
SENSOR AREA
tCONV_LP
16
30
PROXIMITY
DETECTION
(INTERNAL)
tCALDIS
CALIBRATION
(INTERNAL)
CALIBRATION DISABLED
70
RECALIBRATION TIMEOUT
CALIBRATION ENABLED
tRECAL_TIMEOUT
RECALIBRATION
(INTERNAL)
NOTES
1. SEQUENCE CONVERSION TIME tCONV_LP = tCONV_FP + LP_CONV_DELAY.
2. tCALDIS = tCONV_LP × LP_PROXIMITY_CNT × 4.
3. tRECAL_TIMEOUT = tCONV_LP × LP_PROXIMITY_RECAL.
4. tRECAL = 2 × tCONV_LP .
Figure 33. Example of Low Power Mode Proximity Detection with Forced Recalibration (LP_PROXIMITY_CNT = 4 and LP_PROXIMITY_RECAL = 40)
Rev. E | Page 21 of 70
06663-030
CDC CONVERSION
SEQUENCE
(INTERNAL)
AD7147
Data Sheet
FF_SKIP_CNT
The proximity detection fast FIFO is used by the on-chip logic
to determine if proximity is detected. The fast FIFO expects to
receive samples from the converter at a set rate. FF_SKIP_CNT
is used to normalize the frequency of the samples going into the
FIFO, regardless of how many conversion stages are in a sequence.
In Register 0x002, Bits[3:0] are the fast filter skip control,
FF_SKIP_CNT. This value determines which CDC samples
are not used (skipped) by the proximity detection fast FIFO.
Determining the FF_SKIP_CNT value is required only once
during the initial setup of the capacitance sensor interface.
Table 13 shows how FF_SKIP_CNT controls the update rate of
the fast FIFO. The recommended value for the setting when
using all 12 conversion stages on the AD7147 is 0000, or no
samples skipped.
Table 13. FF_SKIP_CNT Settings
FF_SKIP
_CNT
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Decimation = 64
0.768 × (SEQUENCE_STAGE_NUM + 1) ms
1.536 × (SEQUENCE_STAGE_NUM + 1) ms
2.3 × (SEQUENCE_STAGE_NUM + 1) ms
3.072 × (SEQUENCE_STAGE_NUM + 1) ms
3.84 × (SEQUENCE_STAGE_NUM + 1) ms
4.6 × (SEQUENCE_STAGE_NUM + 1) ms
5.376 × (SEQUENCE_STAGE_NUM + 1) ms
6.144 × (SEQUENCE_STAGE_NUM + 1) ms
6.912 × (SEQUENCE_STAGE_NUM + 1) ms
7.68 × (SEQUENCE_STAGE_NUM + 1) ms
8.448 × (SEQUENCE_STAGE_NUM + 1) ms
9.216 × (SEQUENCE_STAGE_NUM + 1) ms
9.984 × (SEQUENCE_STAGE_NUM + 1) ms
10.752 × (SEQUENCE_STAGE_NUM + 1) ms
11.52 × (SEQUENCE_STAGE_NUM + 1) ms
12.288 × (SEQUENCE_STAGE_NUM + 1) ms
FAST FIFO Update Rate
Decimation = 128
1.536 × (SEQUENCE_STAGE_NUM + 1) ms
3.072 × (SEQUENCE_STAGE_NUM + 1) ms
4.608 × (SEQUENCE_STAGE_NUM + 1) ms
6.144 × (SEQUENCE_STAGE_NUM + 1) ms
7.68 × (SEQUENCE_STAGE_NUM + 1) ms
9.216 × (SEQUENCE_STAGE_NUM + 1) ms
10.752 × (SEQUENCE_STAGE_NUM + 1) ms
12.288 × (SEQUENCE_STAGE_NUM + 1) ms
13.824 × (SEQUENCE_STAGE_NUM + 1) ms
15.36 × (SEQUENCE_STAGE_NUM + 1) ms
16.896 × (SEQUENCE_STAGE_NUM + 1) ms
18.432 × (SEQUENCE_STAGE_NUM + 1) ms
19.968 × (SEQUENCE_STAGE_NUM + 1) ms
21.504 × (SEQUENCE_STAGE_NUM + 1) ms
23.04 × (SEQUENCE_STAGE_NUM + 1) ms
24.576 × (SEQUENCE_STAGE_NUM + 1) ms
Rev. E | Page 22 of 70
Decimation = 256
3.072 × (SEQUENCE_STAGE_NUM + 1) ms
6.144 × (SEQUENCE_STAGE_NUM + 1) ms
9.216 × (SEQUENCE_STAGE_NUM + 1) ms
12.288 × (SEQUENCE_STAGE_NUM + 1) ms
15.36 × (SEQUENCE_STAGE_NUM + 1) ms
18.432 × (SEQUENCE_STAGE_NUM + 1) ms
21.504 × (SEQUENCE_STAGE_NUM + 1) ms
24.576 × (SEQUENCE_STAGE_NUM + 1) ms
27.648 × (SEQUENCE_STAGE_NUM + 1) ms
30.72 × (SEQUENCE_STAGE_NUM + 1) ms
33.792 × (SEQUENCE_STAGE_NUM + 1) ms
36.864 × (SEQUENCE_STAGE_NUM + 1) ms
39.936 × (SEQUENCE_STAGE_NUM + 1) ms
43.008 × (SEQUENCE_STAGE_NUM + 1) ms
46.08 × (SEQUENCE_STAGE_NUM + 1) ms
49.152 × (SEQUENCE_STAGE_NUM + 1) ms
Data Sheet
CDC
AD7147
FP_PROXIMITY_CNT
REGISTER 0x002
16
LP_PROXIMITY_CNT
REGISTER 0x002
STAGEx_FF_WORD0
STAGEx_FF_WORD1
STAGEx_FF_WORD2
COMPARATOR 1
|WORD0 – WORD3|
PROXIMITY 1
PROXIMITY
STAGEx_FF_WORD3
STAGEx_FF_WORD4
STAGEx_FF_WORD5
STAGEx_FF_WORD6
STAGEx_FF_WORD7
PROXIMITY_DETECTION_RATE
REGISTER 0x003
7
WORD(N)
Σ
N=0
FP_PROXIMITY_RECAL
REGISTER 0x004
LP_PROXIMITY_RECAL
REGISTER 0x004
PROXIMITY 2
BANK 3 REGISTERS
PROXIMITY TIMING
CONTROL LOGIC
STAGEx_FF_AVG
BANK 3 REGISTERS
8
COMPARATOR 2
|AVERAGE – AMBIENT|
STAGEx_FF_WORDx
PROXIMITY
SLOW_FILTER_UPDATE_LVL
REGISTER 0x003
STAGEx_SF_WORD0
STAGEx_SF_WORD1
STAGEx_SF_WORD2
STAGEx_SF_WORD3
PROXIMITY_RECAL_LVL
REGISTER 0x003
STAGEx_SF_AMBIENT
BANK 3 REGISTERS
STAGEx_SF_WORD4
STAGEx_SF_WORD5
STAGEx_SF_WORD6
AMBIENT
VALUE
STAGEx_SF_WORDx
SENSOR
CONTACT
t
STAGEx_SF_WORD7
BANK 3 REGISTERS
NOTES
1. SLOW_FILTER_EN, WHICH IS THE NAME OF THE OUTPUT OF COMPARATOR 3, IS SET AND SW1 IS CLOSED WHEN |STAGEx_SF_WORD0 – CDC VALUE|
EXCEEDS THE VALUE PROGRAMMED IN THE SLOW_FILTER_UPDATE_LVL REGISTER PROVIDING PROXIMITY IS NOT SET.
2. PROXIMITY 1 IS SET WHEN |STAGEx_FF_WORD0 – STAGEx_FF_WORD3| EXCEEDS THE VALUE PROGRAMMED IN THE
PROXIMITY_DETECTION_RATE REGISTER.
3. PROXIMITY 2 IS SET WHEN |AVERAGE – AMBIENT| EXCEEDS THE VALUE PROGRAMMED IN THE PROXIMITY_RECAL_LVL REGISTER.
4. DESCRIPTION OF COMPARATOR FUNCTIONS:
COMPARATOR 1: USED TO DETECT WHEN A USER IS APPROACHING OR LEAVING A SENSOR.
COMPARATOR 2: USED TO DETECT WHEN A USER IS HOVERING OVER A SENSOR OR APPROACHING A SENSOR VERY SLOWLY.
ALSO USED TO DETECT IF THE SENSOR AMBIENT LEVEL HAS CHANGED AS A RESULT OF THE USER INTERACTION.
FOR EXAMPLE, HUMIDITY OR DIRT LEFT BEHIND ON SENSOR.
COMPARATOR 3: USED TO ENABLE THE SLOW FILTER UPDATE RATE. THE SLOW FILTER IS UPDATED WHEN SLOW_FILTER_EN IS SET AND
PROXIMITY IS NOT SET.
Figure 34. AD7147 Proximity-Detection Logic
Rev. E | Page 23 of 70
06663-031
COMPARATOR 3
WORD0 – CDC VALUE
CDC OUTPUT CODE
SLOW_FILTER_EN
SW1
AD7147
Data Sheet
ENVIRONMENTAL CALIBRATION
The ambient compensation control registers provide the host
with access to general setup and controls for the compensation
algorithm. On-chip RAM stores the compensation data for each
conversion stage, as well as setup information specific for each stage.
Figure 35 shows an example of the ideal behavior of a capacitance sensor, where the CDC ambient level remains constant
regardless of the environmental conditions. The CDC output
shown is for a pair of differential button sensors, where one
sensor caused an increase and the other caused a decrease in
measured capacitance when activated. The positive and negative
sensor threshold levels are calculated as a percentage of the
STAGEx_OFFSET_HIGH and STAGEx_OFFSET_LOW values
and are based on the threshold sensitivity settings and the
ambient value. These values are sufficient to detect a sensor
contact and result in the AD7147 asserting the INT output
when the threshold levels are exceeded.
CDC AMBIENT VALUE
STAGEx_LOW_THRESHOLD
06663-032
SENSOR 2 INT
ASSERTED
t
CHANGING ENVIRONMENTAL CONDITIONS
Figure 35. Ideal Sensor Behavior with a Constant Ambient Level
CAPACITANCE SENSOR BEHAVIOR WITHOUT
CALIBRATION
Figure 36 shows the typical behavior of a capacitance sensor
when calibration is not applied. This figure shows ambient
levels drifting over time as environmental conditions change. As
a result of the initial threshold levels remaining constant while
the ambient levels drift upward, Sensor 2 fails to detect a user
contact in this example.
The Capacitance Sensor Behavior with Calibration section
describes how the AD7147 adaptive calibration algorithm
prevents such errors from occurring.
SENSOR 1 INT
ASSERTED
STAGEx_HIGH_THRESHOLD
CDC AMBIENT
VALUE DRIFTING
STAGEx_LOW_THRESHOLD
SENSOR 2 INT
NOT ASSERTED
t
CHANGING ENVIRONMENTAL CONDITIONS
Figure 36. Typical Sensor Behavior Without Calibration
Rev. E | Page 24 of 70
06663-033
After the AD7147 is configured, the compensation logic runs
automatically with each conversion when the AD7147 is not
being touched. This allows the AD7147 to compensate for
rapidly changing environmental conditions.
STAGEx_HIGH_THRESHOLD
CDC OUTPUT CODES
The AD7147 achieves optimal and reliable sensor performance
by continuously monitoring the CDC ambient levels and compensating for any environmental changes by adjusting the values of
the STAGEx_HIGH_THRESHOLD register and the STAGEx_
LOW_THRESHOLD registers as described in the Threshold
Equations section. The CDC ambient level is defined as the
output level of the capacitance sensor during periods when the
user is not approaching or in contact with the sensor.
SENSOR 1 INT
ASSERTED
CDC OUTPUT CODES
The AD7147 provides on-chip capacitance sensor calibration to
automatically adjust for environmental conditions that have an
effect on the ambient levels of the capacitance sensor. The output
levels of the capacitance sensor are sensitive to temperature,
humidity, and, in some cases, dirt.
Data Sheet
AD7147
THRESHOLD EQUATIONS
On-Chip Logic Stage High Threshold
 STAGEx _ OFFSET _ HIGH 

4


STAGEx _ OFFSET _ HIGH  

  STAGEx _ OFFSET _ HIGH 

4
   POS _ THRESHOLD_ SENSITIVITY



16




STAGEx _ HIGH _ THRESHOLD  STAGEx _ SF _ AMBIENT  
(1)
On-Chip Logic Stage Low Threshold
 STAGEx _ OFFSET _ LOW 
STAGEx _ LOW _ THRESHOLD  STAGEx _ SF _ AMBIENT  

4


STAGEx _ OFFSET _ LOW  

  STAGEx _ OFFSET _ LOW 

4
   NEG _ THRESHOLD _ SENSITIVITY



16




SLOW FIFO
CAPACITANCE SENSOR BEHAVIOR WITH
CALIBRATION
The AD7147 on-chip adaptive calibration algorithm prevents
sensor detection errors such as the one shown in Figure 36.
This is achieved by monitoring the CDC ambient levels
and readjusting the initial STAGEx_OFFSET_HIGH and
STAGEx_OFFSET_LOW values according to the amount of
ambient drift measured on each sensor. Based on the new
stage offset values, the internal STAGEx_HIGH_THRESHOLD
and STAGEx_LOW_THRESHOLD values described in
Equation 1 and Equation 2 are automatically updated.
This closed-loop routine ensures the reliability and repeatable
operation of every sensor connected to the AD7147 when they
are subjected to dynamic environmental conditions. Figure 37
shows a simplified example of how the AD7147 applies the
adaptive calibration process, resulting in no interrupt errors
even with changing CDC ambient levels due to dynamic
environmental conditions.
SENSOR 1 INT
ASSERTED
CDC OUTPUT CODES
AVG_FP_SKIP and AVG_LP_SKIP
In Register 0x001, Bits[13:12] are the slow FIFO skip control for
full power mode, AVG_FP_SKIP. Bits[15:14] in the same
register are the slow FIFO skip control for low power mode,
AVG_LP_SKIP, and determine which CDC samples are not
used (skipped) in the slow FIFO. Changing the values of the
AVG_FP_SKIP and AVG_LP_SKIP bits slows down or speeds
up the rate at which the ambient capacitance value tracks the
measured capacitance value read by the converter:

STAGEx_HIGH_THRESHOLD
(POSTCALIBRATED
REGISTER VALUE)
1
CDC AMBIENT
VALUE DRIFTING
STAGEx_LOW_THRESHOLD
(POSTCALIBRATED
REGISTER VALUE)
4
SENSOR 2 INT
ASSERTED
t
Determining the AVG_FP_SKIP and AVG_LP_SKIP values is
required only once during the initial setup of the capacitance
sensor interface. The recommended values for these settings
when using all 12 conversion stages on the AD7147 are as follows:
06663-034
1INITIAL STAGEx_OFFSET_HIGH REGISTER VALUE.
2POSTCALIBRATED REGISTER STAGEx_HIGH_THRESHOLD.
3POSTCALIBRATED REGISTER STAGEx_HIGH_THRESHOLD.
4INITIAL STAGEx_LOW_THRESHOLD.
5POSTCALIBRATED REGISTER STAGEx_LOW_THRESHOLD.
6POSTCALIBRATED REGISTER STAGEx_LOW_THRESHOLD.
Slow FIFO update rate in full power mode = AVG_FP_SKIP ×
[(3 × Decimation Rate) × (SEQUENCE_STAGE_NUM + 1) ×
(FF_SKIP_CNT + 1) × 4 × 10−7].
Slow FIFO update rate in low power mode = (AVG_LP_SKIP
+ 1) × [(3 × Decimation Rate) × (SEQUENCE_STAGE_NUM
+ 1) × (FF_SKIP_CNT + 1) × 4 x 10−7]/[(FF_SKIP_CNT + 1)
+ LP_CONV_DELAY].
The slow FIFO is used by the on-chip logic to track the ambient
capacitance value. The slow FIFO expects to receive samples from
the converter at a rate between 33 ms and 40 ms. AVG_FP_SKIP
and AVG_LP_SKIP are used to normalize the frequency of the
samples going into the FIFO, regardless of how many conversion
stages are in a sequence.
6
5
CHANGING ENVIRONMENTAL CONDITIONS
As shown in Figure 34, there are a number of FIFOs
implemented on the AD7147. These FIFOs are located in
Bank 3 of the on-chip memory. The slow FIFOs are used by the
on-chip logic to monitor the ambient capacitance level from
each sensor.

3
2
(2)
Figure 37. Typical Sensor Behavior with Calibration Applied on the Data Path


Rev. E | Page 25 of 70
AVG_FP_SKIP = 00 = skip three samples
AVG_LP_SKIP = 00 = skip zero samples
AD7147
Data Sheet
SLOW_FILTER_UPDATE_LVL
The SLOW_FILTER_UPDATE_LVL controls whether the most
recent CDC measurement goes into the slow FIFO (slow filter).
The slow filter is updated when the difference between the
current CDC value and the last value of the slow FIFO is greater
than the value of SLOW_FILTER_UPDATE_LVL. This variable
is in Ambient Control Register 1 (AMB_COMP_CTRL1)
(Address 0x003).
Rev. E | Page 26 of 70
Data Sheet
AD7147
ADAPTIVE THRESHOLD AND SENSITIVITY
The AD7147 provides an on-chip, self-adjusting adaptive
threshold and sensitivity algorithm. This algorithm continuously monitors the output levels of each sensor and automatically
rescales the threshold levels in proportion to the sensor area
covered by the user. As a result, the AD7147 maintains optimal
threshold and sensitivity levels for all users regardless of their
finger sizes.
The threshold level is always referenced from the ambient level
and is defined as the CDC converter output level that must be
exceeded before a valid sensor contact can occur. The sensitivity
level is defined as how sensitive the sensor must be before a
valid contact can be registered.
Figure 38 provides an example of how the adaptive threshold
and sensitivity algorithm works. The positive and negative
sensor threshold levels are calculated as a percentage of the
STAGEx_OFFSET_HIGH and STAGEx_OFFSET_LOW
values and are based on the threshold sensitivity settings and
the ambient value. After the AD7147 is configured, initial
estimates are supplied for both STAGEx_OFFSET_HIGH
and STAGEx_OFFSET_LOW, and then the calibration engine
automatically adjusts the STAGEx_HIGH_THRESHOLD and
STAGEx_LOW_THRESHOLD values for sensor response.
The AD7147 tracks the average maximum and minimum values
measured from each sensor. These values provide an indication
of how the user is interacting with the sensor. A large finger
results in a large average maximum or minimum value, whereas
a small finger results in smaller values. When the average
maximum or minimum value changes, the threshold levels are
rescaled to ensure that the threshold levels are appropriate for
the current user. Figure 39 shows how the minimum and
maximum sensor responses are tracked by the on-chip logic.
Reference A in Figure 38 shows a less sensitive threshold level
for a user with small fingers and demonstrates the disadvantages
of a fixed threshold level.
By enabling the adaptive threshold and sensitivity algorithm, the
positive and negative threshold levels are determined by the
POS_THRESHOLD_SENSITIVITY and NEG_THRESHOLD_
SENSITIVITY bit values and by the most recent average maximum sensor output value. These bits can be used to select 16
different positive and negative sensitivity levels ranging between
25% and 95.32% of the most recent average maximum output
level referenced from the ambient value. The smaller the sensitivity
percentage setting, the easier it is to trigger a sensor activation.
Reference B shows that the positive adaptive threshold level is
set at almost mid-sensitivity with a 62.51% threshold level by
setting POS_THRESHOLD_ SENSITIVITY = 1000. Figure 38
also provides a similar example for the negative threshold level,
with NEG_THRESHOLD_SENSITIVITY = 0011.
AVERAGE MAXIMUM VALUE
STAGEx_OFFSET_HIGH
IS UPDATED
AVERAGE MAXIMUM VALUE
62.51% =
POS_THRESHOLD
_SENSITIVITY
A
STAGEx_OFFSET_HIGH
95.32%
STAGEx_OFFSET_HIGH
IS UPDATED
62.51% =
POS_THRESHOLD
_SENSITIVITY
25%
25%
B
AMBIENT LEVEL
25%
NEG_THRESHOLD_SENSITIVITY = 39.08%
STAGEx_OFFSET_LOW
IS UPDATED
STAGEx_OFFSET_LOW
25%
NEG_THRESHOLD_SENSITIVITY = 39.08%
95.32%
STAGEx_OFFSET_LOW
IS UPDATED
95.32%
SENSOR CONTACTED
BY LARGE FINGER
SENSOR CONTACTED
BY SMALL FINGER
Figure 38. Example of Threshold Sensitivity (POS_THRESHOLD_SENSITIVITY = 1000, NEG_THRESHOLD_SENSITIVITY = 0011)
Rev. E | Page 27 of 70
06663-035
CDC OUTPUT CODES
95.32%
AD7147
Data Sheet
STAGEx_MAX_WORD0
STAGEx_MAX_WORD1
STAGEx_MAX_WORD2
BANK 3 REGISTERS
STAGEx_MAX_WORD3
Σ-∆
16-BIT
CDC
16
MAXIMUM
LEVEL
DETECTION
LOGIC
STAGEx_MAX_AVG
BANK 3 REGISTERS
STAGEx_MAX_TEMP
BANK 3 REGISTERS
STAGEx_HIGH_THRESHOLD
BANK 3 REGISTERS
STAGEx_MIN_WORD0
STAGEx_MIN_WORD1
STAGEx_MIN_WORD2
BANK 3 REGISTERS
STAGEx_MIN_WORD3
MINIMUM
LEVEL
DETECTION
LOGIC
STAGEx_MIN_AVG
BANK 3 REGISTERS
STAGEx_LOW_THRESHOLD
BANK 3 REGISTERS
06663-036
STAGEx_MIN_TEMP
BANK 3 REGISTERS
Figure 39. Tracking the Minimum and Maximum Average Sensor Values
Table 14. Additional Information About Environmental Calibration and Adaptive Threshold Registers
Register/Bit
NEG_THRESHOLD_SENSITIVITY
NEG_PEAK_DETECT
Register
Location
Bank 2
Bank 2
POS_THRESHOLD_SENSITIVITY
POS_PEAK_DETECT
Bank 2
Bank 2
STAGEx_OFFSET_LOW
Bank 2
STAGEx_OFFSET_HIGH
Bank 2
STAGEx_OFFSET_HIGH_CLAMP
Bank 2
STAGEx_OFFSET_LOW_CLAMP
Bank 2
STAGEx_SF_AMBIENT
Bank 3
STAGEx_HIGH_THRESHOLD
STAGEx_LOW_THRESHOLD
Bank 3
Bank 3
Description
Used in Equation 2. This value is programmed once at startup.
Used by internal adaptive threshold logic only.
The NEG_PEAK_DETECT is set to a percentage of the difference between the ambient
CDC value and the minimum average CDC value. If the output of the CDC approaches the
NEG_PEAK_DETECT percentage of the minimum average, the minimum average value is updated.
Used in Equation 1. This value is programmed once at startup.
Used by internal adaptive threshold logic only.
The POS_PEAK_DETECT is set to a percentage of the difference between the ambient
CDC value and the maximum average CDC value. If the output of the CDC approaches the
POS_PEAK_DETECT percentage of the maximum average, the maximum average value is updated.
Used in Equation 2. An initial value (based on sensor characterization) is programmed into
this register at startup. The AD7147 on-chip calibration algorithm automatically updates this
register based on the amount of sensor drift due to changing ambient conditions. Set this
register to 80% of the STAGEx_OFFSET_LOW_CLAMP value.
Used in Equation 1. An initial value (based on sensor characterization) is programmed into
this register at startup. The AD7147 on-chip calibration algorithm automatically updates this
register based on the amount of sensor drift due to changing ambient conditions. Set this
register to 80% of the STAGEx_OFFSET_HIGH_CLAMP value.
Used by internal environmental calibration and adaptive threshold algorithms only.
An initial value (based on sensor characterization) is programmed into this register at startup.
The value in this register prevents a user from causing the output value of a sensor to exceed
the expected nominal value.
Set this register to the maximum expected sensor response or the maximum change in CDC
output code.
Used by internal environmental calibration and adaptive threshold algorithms only.
An initial value (based on sensor characterization) is programmed into this register at startup.
The value in this register prevents a user from causing the output value of a sensor to exceed
the expected nominal value.
Set this register to the minimum expected sensor response or the minimum change in CDC
output code.
Used in Equation 1 and Equation 2. This is the ambient sensor output when the sensor is not
touched, as calculated using the slow FIFO.
Equation 1 value.
Equation 2 value.
Rev. E | Page 28 of 70
Data Sheet
AD7147
INTERRUPT OUTPUT
The AD7147 has an interrupt output that triggers an interrupt
service routine on the host processor. The INT signal is on
Pin 17 and is an open-drain output. There are three types of
interrupt events on the AD7147: a CDC conversion-complete
interrupt, a sensor touch interrupt, and a GPIO interrupt. Each
interrupt has enable and status registers. The conversioncomplete and sensor-touch (sensor-activation) interrupts can be
enabled on a per-conversion-stage basis. The status registers
indicate what type of interrupt triggered the INT pin. Status
registers are cleared, and the INT signal is reset high during a
read operation. The signal returns high as soon as the read
address has been set up.
CDC CONVERSION-COMPLETE INTERRUPT
The AD7147 interrupt signal asserts low to indicate the completion
of a conversion stage and that new conversion result data is
available in the registers.
The interrupt can be independently enabled for each conversion
stage. Each conversion-stage-complete interrupt can be enabled via
the STAGEx_COMPLETE_INT_ENABLE register (Address 0x007).
This register has a bit that corresponds to each conversion stage.
Setting this bit to 1 enables the interrupt for that stage. Clearing this
bit to 0 disables the conversion-complete interrupt for that stage.
The AD7147 interrupt should be enabled only for the last stage
in a conversion sequence. For example, if there are five conversion stages, only the conversion-complete interrupt for STAGE4
is enabled. Therefore, INT only asserts when all five conversion
stages are complete and the host can read new data from all five
result registers. The interrupt is cleared by reading the STAGEx_
COMPLETE_INT_STATUS register located at Address 0x00A.
SENSOR-TOUCH INTERRUPT
The sensor-touch interrupt mode is implemented when the host
processor requires an interrupt only when a sensor is contacted.
Configuring the AD7147 into this mode results in the interrupt
being asserted when the user makes contact with the sensor and
again when the user stops touching the sensor. The second
interrupt is required to alert the host processor that the user is
no longer contacting the sensor.
The registers located at Address 0x005 and Address 0x006 are
used to enable the interrupt output for each stage. The registers
located at Address 0x008 and Address 0x009 are used to read
back the interrupt status for each stage.
Figure 40 shows the interrupt output timing during contact with
one of the sensors connected to STAGE0 while operating in the
sensor-touch interrupt mode. For a low limit configuration, the
interrupt output is asserted as soon as the sensor is contacted and
again after the user has stopped contacting the sensor. (Note that
the interrupt output remains low until the host processor reads
back the interrupt status registers located at Address 0x008 and
Address 0x009.)
The interrupt output is asserted when there is a change in the
interrupt status bits. This can indicate that a user is touching the
sensor(s) for the first time, the number of sensors being touched
has changed, or the user is no longer touching the sensor(s).
Reading the status bits in the interrupt status register shows the
current sensor activations.
FINGER ON SENSOR
FINGER OFF SENSOR
Register 0x00A is the conversion-complete interrupt status
register. Each bit in this register corresponds to a conversion
stage. If a bit is set, it means that the conversion-complete
interrupt for the corresponding stage was triggered. This
register is cleared upon a read if the underlying condition
that triggered the interrupt is not present.
1
3
CONVERSION
STAGE
STAGE0
2
STAGE1
4
SERIAL
READBACK
1USER TOUCHING SENSOR.
2ADDRESS 0x008 IS READ BACK TO
3USER STOPS TOUCHING SENSOR.
4ADDRESS 0x008 IS READ BACK TO
CLEAR INTERRUPT.
CLEAR INTERRUPT.
Figure 40. Example of Sensor-Touch Interrupt
Rev. E | Page 29 of 70
06663-037
INT OUTPUT
AD7147
CONVERSIONS
Data Sheet
STAGE0
STAGE1
STAGE2
STAGE3
STAGE4
STAGE5
STAGE6
STAGE7
STAGE8
STAGE9
STAGE10
STAGE11
INT
1
2
3
SERIAL
READS
NOTES
THIS IS AN EXAMPLE OF A CDC CONVERSION-COMPLETE INTERRUPT.
THIS TIMING EXAMPLE SHOWS THAT THE INTERRUPT OUTPUT HAS BEEN ENABLED TO BE ASSERTED AT THE END OF A CONVERSION CYCLE FOR
STAGE0, STAGE5, AND STAGE9. THE INTERRUPTS FOR ALL OTHER STAGES HAVE BEEN DISABLED.
STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE0, STAGE5, AND STAGE9 (x = 0, 5, 9):
STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0
STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0
STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 1
SERIAL READBACK REQUIREMENTS FOR STAGE0, STAGE5, AND STAGE9 (THIS READBACK OPERATION IS REQUIRED TO CLEAR THE INTERRUPT OUTPUT.):
1READ THE STAGE0_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT
2READ THE STAGE5_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT
3READ THE STAGE9_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT
06663-038
STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE1 THROUGH STAGE8, STAGE10, AND STAGE11 (x = 1, 2, 3, 4, 5, 6, 7, 8, 10, 11):
STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0
STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0
STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0
Figure 41. Example of Configuring the Registers for Conversion-Complete Interrupt Setup
CONVERSIONS
STAGE0
STAGE1
STAGE2
STAGE3
STAGE4
STAGE5
STAGE6
STAGE7
STAGE8
STAGE9
STAGE10
STAGE11
INT
1
4
2
SERIAL
READS
NOTES
THIS IS AN EXAMPLE OF A SENSOR-TOUCH INTERRUPT FOR A CASE WHERE THE LOW THRESHOLD LEVELS WERE EXCEEDED.
FOR EXAMPLE, THE SENSOR CONNECTED TO STAGE0 AND STAGE9 WERE CONTACTED, AND THE LOW THRESHOLD LEVELS WERE EXCEEDED, RESULTING
IN THE INTERRUPT BEING ASSERTED. THE STAGE6 INTERRUPT WAS NOT ASSERTED BECAUSE THE USER DID NOT CONTACT THE SENSOR CONNECTED TO
STAGE6.
STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE0, STAGE6, AND STAGE9 (x = 0, 6, 9):
STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 1
STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0
STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0
SERIAL READBACK REQUIREMENTS FOR STAGE0 AND STAGE9 (THIS READBACK OPERATION IS REQUIRED TO CLEAR THE INTERRUPT OUTPUT.):
1READ THE STAGE0_LOW_INT_STATUS (ADDRESS 0x008) BIT
2READ THE STAGE5_LOW_INT_STATUS (ADDRESS 0x008) BIT
Figure 42. Example of Configuring the Registers for Sensor-Touch Interrupt Setup
Rev. E | Page 30 of 70
06663-039
STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE1 THROUGH STAGE7, STAGE8, STAGE10, AND STAGE11 (x = 1, 2, 3, 4, 5, 6, 7, 8, 10, 11):
STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0
STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0
STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0
Data Sheet
AD7147
GPIO INT OUTPUT CONTROL
The INT output signal can be controlled by the GPIO pin when
the GPIO is configured as an input. The GPIO is con-figured as
an input by setting the GPIO_SETUP bits in the interrupt configuration register to 01. See the General-Purpose Input/Output
(GPIO) section for more information on configuring the GPIO.
Enable the GPIO interrupt by setting the GPIO_INT_ENABLE
bit in Register 0x007 to 1, or disable the GPIO interrupt by
clearing this bit to 0. The GPIO status bit in the conversioncomplete interrupt status register reflects the status of the GPIO
interrupt. This bit is set to 1 when the GPIO has triggered INT.
The bit is cleared upon reading the GPIO_INT_STATUS bit if the
condition that caused the interrupt is no longer present.
The GPIO interrupt can be set to trigger on a rising edge, falling
edge, high level, or low level at the GPIO input pin. Table 15 shows
how the settings of the GPIO_INPUT_CONFIG bits in the interrupt enable (STAGE_LOW_INT_ENABLE) register affect the
behavior of INT.
Figure 43 to Figure 46 show how the interrupt output is cleared
upon a read from the GPIO_INT_STATUS bit.
1
1
SERIAL
READBACK
SERIAL
READBACK
GPIO INPUT HIGH WHEN REGISTER IS READ BACK
GPIO INPUT HIGH WHEN REGISTER IS READ BACK
GPIO
INPUT
GPIO
INPUT
INT
OUTPUT
INT
OUTPUT
GPIO INPUT LOW WHEN REGISTER IS READ BACK
GPIO INPUT LOW WHEN REGISTER IS READ BACK
GPIO
INPUT
GPIO
INPUT
INT
OUTPUT
1READ GPIO_INT_STATUS BIT TO RESET INT OUTPUT.
Figure 43. Example of INT Output Controlled by the GPIO Input
(GP IO_SETUP = 01, GPIO_INPUT_CONFIG = 00)
Figure 44. Example of INT Output Controlled by the GPIO Input
(GPIO_SETUP = 01, GPIO_INPUT_CONFIG = 01)
Rev. E | Page 31 of 70
06663-041
06663-040
1READ GPIO_INT_STATUS BIT TO RESET INT OUTPUT.
INT
OUTPUT
AD7147
Data Sheet
1
1
SERIAL
READBACK
SERIAL
READBACK
GPIO INPUT LOW WHEN REGISTER IS READ BACK
GPIO INPUT LOW WHEN REGISTER IS READ BACK
GPIO
INPUT
GPIO
INPUT
INT
OUTPUT
INT
OUTPUT
GPIO INPUT HIGH WHEN REGISTER IS READ BACK
GPIO INPUT HIGH WHEN REGISTER IS READ BACK
GPIO
INPUT
GPIO
INPUT
06663-042
1READ
GPIO_INT_STATUS BIT TO RESET INT OUTPUT.
NOTES
1READ GPIO_INT_STATUS BIT TO RESET INT OUTPUT.
Figure 46. Example of INT Output Controlled by the GPIO Input
(GPIO_SETUP = 01, GPIO_INPUT_CONFIG = 11)
Figure 45. Example of INT Output Controlled by the GPIO Input
(GPIO_SETUP = 01, GPIO_INPUT_CONFIG = 10)
Table 15. GPIO Interrupt Behavior
GPIO_INPUT_CONFIG
00 = Negative Level Triggered
00 = Negative Level Triggered
01 = Positive Edge Triggered
01 = Positive Edge Triggered
10 = Negative Edge Triggered
10 = Negative Edge Triggered
11 = Positive Level Triggered
11 = Positive Level Triggered
GPIO Pin
1
0
1
0
1
0
1
0
GPIO_INT_STATUS
0
1
1
0
0
1
1
0
INT
INT Behavior
1
0
0
1
1
0
0
1
Not triggered
Asserted while signal on GPIO pin is low
Pulses low at low-to-high GPIO transition
Not triggered
Pulses low at high-to-low GPIO transition
Not triggered
Asserted while signal on GPIO pin is high
Not triggered
Rev. E | Page 32 of 70
06663-043
INT
OUTPUT
INT
OUTPUT
Data Sheet
AD7147
OUTPUTS
ACSHIELD OUTPUT
The AD7147 measures capacitance between CINx and ground.
Any capacitance to ground on the signal path between the CINx
pins and the sensor is included in the AD7147 conversion result.
To eliminate stray capacitance to ground, the ACSHIELD signal should
be used to shield the connection between the sensor and CINx,
as shown in Figure 47. The plane around the sensors should also
be connected to ACSHIELD.
When the GPIO is configured as an output, the voltage level on
the pin is set to either a low level or a high level, as defined by
the GPIO_SETUP bits (see Table 16).
The GPIO_INPUT_CONFIG bits in the interrupt enable
register determine the response of the AD7147 to a signal on the
GPIO pin when the GPIO is configured as an input. The GPIO
can be configured as either active high or active low, as well as
either edge triggered or level triggered (see Table 17).
Table 17. GPIO_INPUT_CONFIG Bits
06663-044
Figure 47. ACSHIELD
The ACSHIELD output is the same signal waveform as the
excitation signal on CINx. Therefore, there is no ac current
between CINx and ACSHIELD, and any capacitance between these
pins does not affect the CINx charge transfer.
Using ACSHIELD eliminates capacitance-to-ground pickup, which
means that the AD7147 can be placed up to 10 cm away from
the sensors. This allows the AD7147 to be placed on a separate
PCB than that of the sensors if the connections between the
sensors and the CINx inputs are correctly shielded using
ACSHIELD.
GPIO_INPUT_CONFIG
00
01
10
11
When GPIO is configured as an input, it triggers the interrupt
output on the AD7147. Table 15 lists the interrupt output
behavior for each of the GPIO configuration setups.
USING THE GPIO TO TURN ON/OFF AN LED
The GPIO on the AD7147 can be used to turn on and off an
LED by setting the GPIO as either output high or low. Setting
the GPIO output high turns on the LED; setting the GPIO
output low turns off the LED. The GPIO pin connects to a
transistor that provides the drive current for the LED. Suitable
transistors include the KTC3875 from Korea Electronics Co.,
Ltd. (KEC).
GENERAL-PURPOSE INPUT/OUTPUT (GPIO)
V
KTC3875 CC
OR SIMILAR
AD7147
The AD7147 has one GPIO pin. It can be configured as an input or
an output. The GPIO_SETUP Bits[13:12] in the interrupt enable
register determine how the GPIO pin is configured.
Table 16. GPIO_SETUP Bits
GPIO_SETUP
00
01
10
11
GPIO Configuration
Triggered on negative level (active low)
Triggered on positive edge (active high)
Triggered on negative edge (active low)
Triggered on positive level (active high)
GPIO
06663-045
SENSOR PCB
CIN0 AD7147
CIN1
CIN2
CIN3
ACSHIELD GND
Figure 48. Controlling an LED Using the GPIO
GPIO Configuration
GPIO disabled
Input
Output low
Output high
Rev. E | Page 33 of 70
AD7147
Data Sheet
SERIAL INTERFACE
The AD7147 is available with an SPI-compatible interface. The
AD7147-1 is available with an I2C-compatible interface. Both
parts are the same, with the exception of the serial interface.
Bits[15:11] of the command word must be set to 11100 to
successfully begin a bus transaction.
Bit 10 is the read/write bit; 1 indicates a read, and 0 indicates
a write.
SPI INTERFACE
Bits[9:0] contain the target register address. When reading or
writing to more than one register, this address indicates the
address of the first register to be written to or read from.
The AD7147 has a 4-wire serial peripheral interface (SPI). The
SPI has a data input pin (SDI) for inputting data to the device, a
data output pin (SDO) for reading data back from the device,
and a data clock pin (SCLK) for clocking data into and out of
the device. A chip select pin (CS) enables or disables the serial
interface. CS is required for correct operation of the SPI. Data is
clocked out of the AD7147 on the negative edge of SCLK and
data is clocked into the device on the positive edge of SCLK.
Writing Data
Data is written to the AD7147 in 16-bit words. The first word
written to the device is the command word, with the read/write
bit set to 0. The master then supplies the 16-bit input data-word
on the SDI line. The AD7147 clocks the data into the register
addressed in the command word. If there is more than one
word of data to be clocked in, the AD7147 automatically increments the address pointer and clocks the subsequent data-word
into the next register.
SPI Command Word
All data transactions on the SPI bus begin with the master
taking CS from high to low and sending out the command
word. This indicates to the AD7147 whether the transaction is a
read or a write and provides the address of the register from
which to begin the data transfer. The following bit map shows
the SPI command word.
MSB
15
1
14
1
13
1
12
0
11
0
The AD7147 continues to clock in data on the SDI line until
either the master finishes the write transition by pulling CS high
or the address pointer reaches its maximum value. The AD7147
address pointer does not wrap around. When it reaches its
maximum value, any data provided by the master on the SDI
line is ignored by the AD7147.
LSB
9:0
Register address
10
R/W
16-BIT COMMAND WORD
ENABLE WORD
SDI
CW
15
CW
14
CW
13
R/W
CW
12
CW
11
t2
SCLK
CW
10
REGISTER ADDRESS
CW
9
CW
8
t4
1
t1
2
3
4
5
CW
7
CW
6
CW
5
CW
4
16-BIT DATA
CW
3
CW
2
CW
1
CW
0
D15
D14
D13
D2
D1
D0
t5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
30
31
32
t8
t3
NOTES
1. SDI BITS ARE LATCHED ON SCLK RISING EDGES. SCLK CAN IDLE HIGH OR LOW BETWEEN WRITE OPERATIONS.
2. ALL 32 BITS MUST BE WRITTEN: 16 BITS FOR THE CONTROL WORD AND 16 BITS FOR THE DATA.
3. 16-BIT COMMAND WORD SETTINGS FOR SERIAL WRITE OPERATION:
CW [15:11] = 11100 (ENABLE WORD)
CW [10] = 0 (R/W)
CW [9:0] = [AD9, AD8, AD7, AD6, AD5, AD4, AD3, AD2, AD1, AD0] (10-BIT MSB-JUSTIFIED REGISTER ADDRESS)
Figure 49. Single Register Write SPI Timing
Rev. E | Page 34 of 70
06663-046
CS
Data Sheet
AD7147
16-BIT COMMAND WORD
ENABLE WORD
SDI
CW
15
CW
14
CW
13
CW
12
CW
11
SCLK
1
2
3
4
5
CW
10
DATA FOR STARTING
REGISTER ADDRESS
STARTING REGISTER ADDRESS
R/W
CW
9
6
CW
8
7
8
CW
7
9
CW
6
CW
5
CW
4
11
10
CW
3
12
CW
2
13
CW
1
14
CW
0
15
D15 D14
16
17
D1
18
DATA FOR NEXT
REGISTER ADDRESS
D0
31
32
D15 D14
33
D1
34
D0
47
D15
48
49
CS
06663-047
NOTES
1. MULTIPLE SEQUENTIAL REGISTERS CAN BE LOADED CONTINUOUSLY.
2. THE FIRST (LOWEST ADDRESS) REGISTER ADDRESS IS WRITTEN, FOLLOWED BY MULTIPLE 16-BIT DATA-WORDS.
3. THE ADDRESS AUTOMATICALLY INCREMENTS WITH EACH 16-BIT DATA-WORD (ALL 16 BITS MUST BE WRITTEN).
4. CS IS HELD LOW UNTIL THE LAST DESIRED REGISTER HAS BEEN LOADED.
5. 16-BIT COMMAND WORD SETTINGS FOR SEQUENTIAL WRITE OPERATION:
CW [15:11] = 11100 (ENABLE WORD)
CW [10] = 0 (R/W)
CW [9:0] = [AD9, AD8, AD7, AD6, AD5, AD4, AD3, AD2, AD1, AD0] (STARTING MSB-JUSTIFIED REGISTER ADDRESS)
Figure 50. Sequential Register Write SPI Timing
16-BIT COMMAND WORD
ENABLE WORD
SDI
CW
15
CW
14
CW
13
R/W
CW
12
CW
11
t2
SCLK
CW
10
REGISTER ADDRESS
CW
9
CW
7
CW
8
t4
1
2
t1
3
4
5
CW
6
CW
5
CW
4
CW
3
CW
2
CW
1
CW
0
X
X
X
X
X
X
t5
6
7
8
9
10
11
12
13
14
15
16
17
18
30
19
t3
31
32
t8
CS
t6
SDO
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
D15
D14
t7
D13
D2
D1
D0
XXX
NOTES
1. SDI BITS ARE LATCHED ON SCLK RISING EDGES. SCLK CAN IDLE HIGH OR LOW BETWEEN WRITE OPERATIONS.
2. THE 16-BIT CONTROL WORD MUST BE WRITTEN ON SDI: 5 BITS FOR ENABLE WORD, 1 BIT FOR R/W, AND 10 BITS FOR REGISTER ADDRESS.
3. THE REGISTER DATA IS READ BACK ON THE SDO PIN.
4. X DENOTES DON’T CARE.
5. XXX DENOTES HIGH IMPEDANCE THREE-STATE OUTPUT.
6. CS IS HELD LOW UNTIL ALL REGISTER BITS HAVE BEEN READ BACK.
7. 16-BIT COMMAND WORD SETTINGS FOR SINGLE READBACK OPERATION:
CW [15:11] = 11100 (ENABLE WORD)
CW [10] = 1 (R/W)
CW [9:0] = [AD9, AD8, AD7, AD6, AD5, AD4, AD3, AD2, AD1, AD0] (10-BIT MSB-JUSTIFIED REGISTER ADDRESS)
06663-048
16-BIT READBACK DATA
Figure 51. Single Register Readback SPI Timing
Reading Data
A read transaction begins when the master writes the command
word to the AD7147 with the read/write bit set to 1. The master
then supplies 16 clock pulses per data-word to be read, and the
AD7147 clocks out data from the addressed register on the SDO
line. The first data-word is clocked out on the first falling edge
of SCLK following the command word, as shown in Figure 51.
The AD7147 continues to clock out data on the SDO line if the
master continues to supply the clock signal on SCLK. The read
transaction finishes when the master takes CS high. If the AD7147
address pointer reaches its maximum value, the AD7147 repeatedly
clocks out data from the addressed register. The address pointer
does not wrap around.
Rev. E | Page 35 of 70
AD7147
Data Sheet
16-BIT COMMAND WORD
ENABLE WORD
R/W
REGISTER ADDRESS
SDI
CW
15
CW
14
CW
13
CW
12
CW
11
CW
10
CW
9
CW
8
CW
7
SCLK
1
2
3
4
5
6
7
8
9
CW
6
10
CW
5
11
CW
4
12
CW
3
13
CW
2
14
CW
1
15
CW
0
X
X
16
17
18
XXX XXX XXX
D15
D14
X
31
X
32
X
X
33
34
X
X
47
48
X
49
CS
XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX
XXX XXX XXX
D1
D0
READBACK DATA FOR
STARTING REGISTER ADDRESS
D15
D14
D1
D0
D15
READBACK DATA FOR
NEXT REGISTER ADDRESS
NOTES
1. MULTIPLE REGISTERS CAN BE READ BACK CONTINUOUSLY.
2. THE 16-BIT CONTROL WORD MUST BE WRITTEN ON SDI: 5 BITS FOR ENABLE WORD, 1 BIT FOR R/W, AND 10 BITS FOR REGISTER ADDRESS.
3. THE ADDRESS AUTOMATICALLY INCREMENTS WITH EACH 16-BIT DATA-WORD BEING READ BACK ON THE SDO PIN.
4. CS IS HELD LOW UNTIL ALL REGISTER BITS HAVE BEEN READ BACK.
5. X DENOTES DON’T CARE.
6. XXX DENOTES HIGH IMPEDANCE THREE-STATE OUTPUT.
7. 16-BIT COMMAND WORD SETTINGS FOR SEQUENTIAL READBACK OPERATION:
CW [15:11] = 11100 (ENABLE WORD)
CW [10] = 1 (R/W)
CW [9:0] = [AD9, AD8, AD7, AD6, AD5, AD4, AD3, AD2, AD1, AD0] (STARTING MSB-JUSTIFIED REGISTER ADDRESS)
06663-049
SDO
Figure 52. Sequential Register Readback SPI Timing
I2C-COMPATIBLE INTERFACE
The AD7147-1 supports the industry standard 2-wire I2C serial
interface protocol. The two wires associated with the I2C timing
are the SCLK and SDA inputs. The SDA is an I/O pin that allows
both register write and register readback operations. The AD7147-1
is always a slave device on the I2C serial interface bus.
It has a 7-bit device address, Address 0101 1XX. The lower two
bits are set by tying the ADD0 and ADD1 pins high or low. The
AD7147-1 responds when the master device sends its device
address over the bus. The AD7147-1 cannot initiate data transfers on the bus.
Table 18. AD7147-1 I2C Device Address
ADD1
0
0
1
1
I2C Address
0101 100
0101 101
0101 110
0101 111
ADD0
0
1
0
1
Data Transfer
2
Data is transferred over the I C serial interface in 8-bit bytes.
The master initiates a data transfer by establishing a start condition, defined as a high-to-low transition on the serial data
line, SDA, while the serial clock line, SCLK, remains high. This
indicates that an address/data stream follows.
All slave peripherals connected to the serial bus respond to the
start condition and shift in the next eight bits, consisting of a
7-bit address (MSB first) plus an R/W bit that determines the
direction of the data transfer. The peripheral whose address
corresponds to the transmitted address responds by pulling the
data line low during the ninth clock pulse. This is known as the
acknowledge bit. All other devices on the bus then remain idle
while the selected device waits for data to be read from or written
to it. If the R/W bit is 0, the master writes to the slave device. If
the R/W bit is 1, the master reads from the slave device.
Data is sent over the serial bus in a sequence of nine clock
pulses—eight bits of data followed by an acknowledge bit from
the slave device. Transitions on the data line must occur during
the low period of the clock signal and remain stable during the
high period, because a low-to-high transition when the clock is
high can be interpreted as a stop signal. The number of data
bytes transmitted over the serial bus in a single read or write
operation is limited only by what the master and slave devices
can handle.
When all data bytes are read or written, a stop condition is
established. A stop condition is defined by a low-to-high
transition on SDA while SCLK remains high. If the AD7147
encounters a stop condition, it returns to its idle condition, and
the address pointer register resets to Address 0x00.
Rev. E | Page 36 of 70
Data Sheet
AD7147
START
AD7147-1 DEVICE ADDRESS
REGISTER ADDRESS [A15:A8]
REGISTER ADDRESS [A7:A0]
SDA
DEV
A6
DEV
A5
DEV
A4
DEV DEV DEV
A3
A2
A1
t1
DEV
A0
R/W ACK
A15
A14
A9
A8
ACK
A7
A6
A1
A0
t3
SCLK
1
2
3
4
5
6
7
8
9
10
11
16
17
18
19
20
25
26
t2
ACK
D15
D14
D9
REGISTER DATA [D7:D0]
ACK
D8
D7
D6
t4
27
28
29
34
D1
36
37
D0
ACK
t6
38
43
AD7147-1 DEVICE ADDRESS
t8
t5
35
START
44
45
DEV
A6
DEV
A5
1
2
DEV
A4
t7
46
NOTES
1. A START CONDITION AT THE BEGINNING IS DEFINED AS A HIGH-TO-LOW TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
2. A STOP CONDITION AT THE END IS DEFINED AS A LOW-TO-HIGH TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
3. 7-BIT DEVICE ADDRESS [DEV A6:DEV A0] = [0 1 0 1 1 X X], WHERE X IS A DON’T CARE BIT.
4. 16-BIT REGISTER ADDRESS [A15:A0] = [X, X, X, X, X, X, A9, A8, A7, A6, A5, A4, A3, A2, A1, A0], WHERE X IS A DON’T CARE BIT.
5. REGISTER ADDRESS [A15:A8] AND REGISTER ADDRESS [A7:A0] ARE ALWAYS SEPARATED BY A LOW ACK BIT.
6. REGISTER DATA [D15:D8] AND REGISTER DATA [D7:D0] ARE ALWAYS SEPARATED BY A LOW ACK BIT.
3
06663-050
STOP
REGISTER DATA [D15:D8]
Figure 53. Example of I2C Timing for Single Register Write Operation
Writing Data over the I2C Bus
The process for writing to the AD7147-1 over the I2C bus is
shown in Figure 53 and Figure 55. The device address is sent
over the bus, followed by the R/W bit being set to 0 and then
two bytes of data that contain the 10-bit address of the internal
data register to be written. The following bit map shows the
upper register address bytes. Note that Bit 7 to Bit 2 in the upper
address byte are don’t care bits. The address is contained in the
10 LSBs of the register address bytes.
MSB
7
X
LSB
6
X
5
X
4
X
3
X
2
X
1
Register
Address
Bit 9
0
Register
Address
Bit 8
The following bit map shows the lower register address bytes.
MSB
7
Reg
Add
Bit 7
6
Reg
Add
Bit 6
5
Reg
Add
Bit 5
4
Reg
Add
Bit 4
3
Reg
Add
Bit 3
2
Reg
Add
Bit 2
1
Reg
Add
Bit 1
LSB
0
Reg
Add
Bit 0
The third data byte contains the eight MSBs of the data to be
written to the internal register. The fourth data byte contains
the eight LSBs of data to be written to the internal register.
The AD7147-1 address pointer register automatically increments
after each write. This allows the master to sequentially write to all
registers on the AD7147-1 in the same write transaction. However,
the address pointer register does not wrap around after the last
address. Therefore, any data written to the AD7147-1 after the
address pointer has reached its maximum value is discarded.
All registers on the AD7147-1 are 16 bits. Two consecutive 8-bit
data bytes are combined and written to the 16-bit registers. To
avoid errors, all writes to the device must contain an even
number of data bytes.
To finish the transaction, the master generates a stop condition
on SDO, or generates a repeat start condition if the master is to
maintain control of the bus.
Reading Data over the I2C Bus
To read from the AD7147-1, the address pointer register must
first be set to the address of the required internal register. The
master performs a write transaction, and then writes to the
AD7147-1 to set the address pointer. Next, the master outputs a
repeat start condition to keep control of the bus, or if this is not
possible, ends the write transaction with a stop condition. A read
transaction is initiated, with the R/W bit set to 1.
The AD7147-1 supplies the upper eight bits of data from the
addressed register in the first readback byte, followed by the
lower eight bits in the next byte. This is shown in Figure 54 and
Figure 55.
Because the address pointer automatically increments after each
read, the AD7147-1 continues to output readback data until the
master sends a no acknowledge and stop condition to the bus. If
the address pointer reaches its maximum value and the master
continues to read from the part, the AD7147-1 repeatedly sends
data from the last register that was addressed.
Rev. E | Page 37 of 70
AD7147
Data Sheet
START
AD7147-1 DEVICE ADDRESS
REGISTER ADDRESS [A15:A8]
REGISTER ADDRESS [A7:A0]
SDA
DEV
A6
DEV
A5
DEV DEV DEV
A2
A1
A3
DEV
A4
t1
DEV
A0
R/W
ACK
7
8
9
A15
A14
A9
A8
A7
ACK
A6
A1
A0
ACK
t3
SCLK
1
2
3
5
4
6
10
11
16
17
18
19
20
25
26
27
t2
P
REGISTER DATA [D7:D0]
AD7147-1 DEVICE ADDRESS
SR
DEV
A6
DEV
A5
DEV
A1
USING
REPEATED START
DEV
A0
ACK
R/W
D7
D6
t4
28
29
P
34
30
D1
DEV
A6
DEV
A5
35
36
DEV
A1
37
38
34
30
ACK
t6
44
39
R/W ACK
D7
D6
45
DEV
A5
DEV
A4
1
2
3
t7
46
D1
DEV
A6
P
D0
ACK
t5
t4
29
AD7147-1 DEVICE ADDRESS
REGISTER DATA [D7:D0]
DEV
A0
SEPARATE READ AND
WRITE TRANSACTIONS
28
D0
t5
AD7147-1 DEVICE ADDRESS
S
t8
36
35
37
38
44
39
45
46
06663-051
NOTES
1. A START CONDITION AT THE BEGINNING IS DEFINED AS A HIGH-TO-LOW TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
2. A STOP CONDITION AT THE END IS DEFINED AS A LOW-TO-HIGH TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
3. THE MASTER GENERATES THE ACK AT THE END OF THE READBACK TO SIGNAL THAT IT DOES NOT WANT ADDITIONAL DATA.
4. 7-BIT DEVICE ADDRESS [DEV A6:DEV A0] = [0 1 0 1 1 X X], WHERE THE TWO LSB Xs ARE DON'T CARE BITS.
5. 16-BIT REGISTER ADDRESS [A15:A0] = [X, X, X, X, X, X, A9, A8, A7, A6, A5, A4, A3, A2, A1, A0], WHERE THE UPPER LSB Xs ARE DON’T CARE BITS.
6. REGISTER ADDRESS [A15:A8] AND REGISTER ADDRESS [A7:A0] ARE ALWAYS SEPARATED BY LOW ACK BITS.
7. REGISTER DATA [D15:D8] AND REGISTER DATA [D7:D0] ARE ALWAYS SEPARATED BY A LOW ACK BIT.
8. THE R/W BIT IS SET TO A1 TO INDICATE A READBACK OPERATION.
Figure 54. Example of I2C Timing for Single Register Readback Operation
WRITE DATA
HIGH BYTE [15:8]
WRITE DATA
LOW BYTE [7:0]
ACK
WRITE DATA
LOW BYTE [7:0]
ACK
ACK
REGISTER ADDR
LOW BYTE
WRITE DATA
HIGH BYTE [15:8]
ACK
REGISTER ADDR
[7:0]
ACK
SR
REGISTER ADDR
[15:8]
ACK
6-BIT DEVICE
W
ADDRESS
ACK
S
ACK
WRITE
P
6-BIT DEVICE
ADDRESS
READ DATA
HIGH BYTE [15:8]
READ DATA
LOW BYTE [7:0]
READ DATA
HIGH BYTE [15:8]
ACK
REGISTER ADDR
HIGH BYTE
ACK
6-BIT DEVICE
W
ADDRESS
R
ACK
S
ACK
READ (USING REPEATED START)
READ DATA
LOW BYTE [7:0]
ACK P
S = START BIT
P = STOP BIT
SR = REPEATED START BIT
READ DATA
HIGH BYTE [15:8]
READ DATA
LOW BYTE [7:0]
READ DATA
HIGH BYTE [15:8]
ACK
S 6-BIT DEVICE
ADDRESS
ACK
P
READ DATA
LOW BYTE [7:0]
ACK P
ACK = ACKNOWLEDGE BIT
ACK = NO ACKNOWLEDGE BIT
06663-052
OUTPUT FROM MASTER
OUTPUT FROM AD7147-1
REGISTER ADDR
LOW BYTE
R
ACK
REGISTER ADDR
HIGH BYTE
ACK
6-BIT DEVICE
W
ADDRESS
ACK
S
ACK
READ (WRITE TRANSACTION SETS UP REGISTER ADDRESS)
Figure 55. Example of Sequential I2C Write and Readback Operations
VDRIVE INPUT
The supply voltage for the pins (SDO, SDI, SCLK, SDA, CS,
INT, and GPIO) associated with both the I2C and SPI serial
interfaces is supplied from the VDRIVE pin and is separate from the
main VCC supply.
This allows the AD7147 to be connected directly to processors
whose supply voltage is less than the minimum operating
voltage of the AD7147 without the need for external levelshifters. The VDRIVE pin can be connected to voltage supplies as
low as 1.65 V and as high as VCC.
Rev. E | Page 38 of 70
Data Sheet
AD7147
PCB DESIGN GUIDELINES
CAPACITIVE SENSOR BOARD MECHANICAL SPECIFICATIONS
Table 19.
Parameter
Distance from Edge of Any Sensor to Edge of Grounded Metal Object
Distance Between Sensor Edges1
Distance Between Bottom of Sensor Board and Controller Board or Grounded
Metal Casing2
Symbol
D1
D2 = D3 = D4
D5
Min
0.1
0
Typ
Max
1.0
Unit
mm
mm
mm
1
The distance is dependent on the application and the position of the switches relative to each other and with respect to the user’s finger position and handling.
Adjacent sensors with no space between them are implemented differentially.
2
The 1.0 mm specification is intended to prevent direct sensor board contact with any conductive material. This specification, however, does not guarantee an absence
of EMI coupling from the controller board to the sensors. To avoid potential EMI-coupling issues, place a grounded metal shield between the capacitive sensor board
and the main controller board, as shown in Figure 58.
CAPACITIVE SENSOR BOARD
D5
METAL OBJECT
CAPACITIVE SENSOR
PRINTED CIRCUIT
8-WAY
SWITCH
CONTROLLER PRINTED CIRCUIT BOARD OR METAL CASING
06663-055
GROUNDED METAL SHIELD
Figure 58. Capacitive Sensor Board with Grounded Shield
CHIP SCALE PACKAGES
D4
SLIDER
BUTTONS
The lands on the chip scale package (CP-24-3) are rectangular.
The PCB pad for these should be 0.1 mm longer than the package
land length and 0.05 mm wider than the package land width.
Center the land on the pad to maximize the solder joint size.
D3
D2
06663-053
D1
Figure 56. Capacitive Sensor Board, Top View
CAPACITIVE SENSOR BOARD
CONTROLLER PRINTED CIRCUIT BOARD OR METAL CASING
Thermal vias can be used on the PCB thermal pad to improve
the thermal performance of the package. If vias are used, they
should be incorporated in the thermal pad at a 1.2 mm pitch
grid. The via diameter should be between 0.3 mm and 0.33 mm,
and the via barrel should be plated with 1 oz copper to plug the via.
Connect the PCB thermal pad to GND.
06663-054
D5
The bottom of the chip scale package has a central thermal pad.
The thermal pad on the printed circuit board should be at least
as large as this exposed pad. To avoid shorting, provide a clearance of at least 0.25 mm between the thermal pad and the inner
edges of the land pattern on the PCB.
Figure 57. Capacitive Sensor Board, Side View
Rev. E | Page 39 of 70
AD7147
Data Sheet
POWER-UP SEQUENCE
To power up the AD7147, use the following sequence when
initially developing the AD7147 and microprocessor serial
interface:
Address 0x004 = 832
1.
Turn on the power supplies to the AD7147.
2.
Write to the Bank 2 registers at Address 0x080 through
Address 0x0DF. These registers are contiguous; therefore, a
sequential register write sequence can be applied.
Address 0x006 = interrupt enable register (depends on
required interrupt behavior)
Address 0x005 = interrupt enable register (depends on
required interrupt behavior)
Address 0x007 = interrupt enable register (depends on
required interrupt behavior)
Note that the Bank 2 register values are unique for each
application. Register values come from characterization of
the sensor in the application.
3.
Write to the Bank 1 registers at Address 0x000 through
Address 0x007, outlined as follows. These registers are
contiguous; therefore, a sequential register write sequence
can be applied (see Figure 50 and Figure 55).
4.
Write to the Bank 1 register, Address 0x001 = 0x0FFF
(depends on number of conversion stages used).
5.
Read back the corresponding interrupt status register at
Address 0x008, Address 0x009, or Address 0x00A. This is
determined by the interrupt output configuration, as
explained in the Interrupt Output section.
Note that the specific registers required to be read back
depend on each application. For buttons, the interrupt
status registers are read back while other sensors read data
back from the AD7147 according to the slider or wheel
algorithm’s requirements. Analog Devices can provide this
information after the user develops the sensor board.
Caution: At this time, Address 0x001 must remain set to a
default value of 0x0000 during this contiguous write
operation.
Register values:
Address 0x000 = 0x82B2
6.
Address 0x001 = 0x000
Repeat Step 5 every time INT is asserted.
Address 0x002 = 0x3230 (depends on number of
conversion stages used)
Address 0x003 = 0x419
POWER
HOST
SERIAL
INTERFACE
CONVERSION STAGES DISABLED
0
1
2
3
4
5
6
7
8
9
10 11
0
1
2
9
10
11
0
1
2
9
10
AD7147 INT
FIRST CONVERSION SEQUENCE
SECOND CONVERSION
SEQUENCE
Figure 59. Recommended Start-Up Sequence
Rev. E | Page 40 of 70
THIRD CONVERSION
SEQUENCE
11
0
1
06663-056
CONVERSION
STAGE
Data Sheet
AD7147
19
CIN0
CIN11
7
SENSOR PCB
SDO
17
HOST WITH SPI
INTERFACE
INT
16
SS
15
SCK
14
MOSI
13
MISO
VHOST
100nF
PLANE AROUND SENSORS CONNECTED TO AC SHIELD
2.2kΩ
VCC 2.7V TO 3.6V
0.1μF
1μF TO 10μF
(OPTIONAL)
1.8V
06663-057
20
CIN1
21
CIN2
22
CIN3
23
SDI
CIN12
BUTTON
SCLK
CIN10
VDRIVE
6
CIN9
18
12
5
CS
AD7147
VCC
BUTTON
CIN8
11
4
GND
3
INT
BIAS
SCROLL
WHEEL
CIN7
9
2
10
BUTTON
GPIO
ACSHIELD
BUTTON
VDRIVE
CIN6
8
1
CIN4
CIN5
24
TYPICAL APPLICATION CIRCUITS
Figure 60. Typical Application Circuit with SPI Interface
VDRIVE
19
SDA
17
2.2kΩ
HOST WITH I2C
INTERFACE
INT
16
15
SCK
14
13
SDO
12
VCC
VDRIVE
ADD0
11
CIN11
18
100nF
0.1μF
VCC 2.7V TO 3.6V
1μF TO 10μF
(OPTIONAL)
Figure 61. Typical Application Circuit with I2C Interface
Rev. E | Page 41 of 70
06663-058
20
CIN1
21
CIN2
22
23
CIN3
CIN0
SCLK
CIN10
7
2-WAY
SWITCH
AD7147-1
CIN9
CIN12
6
ADD1
GND
5
CIN8
10
BUTTON
INT
BIAS
4
CIN7
ACSHIELD
3
2.2kΩ
GPIO
9
BUTTON
VDRIVE
2.2kΩ
CIN6
8
2
SLIDER
CONNECT PLANE AROUND
SENSORS TO ACSHIELD
BUTTON
1
CIN4
CIN5
24
VDRIVE
AD7147
Data Sheet
REGISTER MAP
The AD7147 address space is divided into three register banks,
referred to as Bank 1, Bank 2, and Bank 3. Figure 62 illustrates
the division of these banks.
Bank 1 registers contain control registers, CDC conversion
control registers, interrupt enable registers, interrupt status
registers, CDC 16-bit conversion data registers, device ID
registers, and proximity status registers.
Bank 2 registers contain the configuration registers used to
configure the individual CINx inputs for each conversion stage.
Initialize the Bank 2 configuration registers immediately after
power-up to obtain valid CDC conversion result data.
BANK 2 REGISTERS
ADDR 0x080
SETUP CONTROL
(1 REGISTER)
ADDR 0x088
ADDR 0x001
INTERRUPT ENABLE
(3 REGISTERS)
ADDR 0x0A0
ADDR 0x008
ADDR 0x017
96 REGISTERS
26 REGISTERS
ADDR 0x098
CDC 16-BIT CONVERSION DATA
(12 REGISTERS)
ADDR 0x088
STAGE2 CONFIGURATION
(8 REGISTERS)
STAGE4 CONFIGURATION
(8 REGISTERS)
STAGE5 CONFIGURATION
(8 REGISTERS)
ADDR 0x0B0
STAGE6 CONFIGURATION
(8 REGISTERS)
DEVICE ID REGISTER
(1 REGISTER)
ADDR 0x098
STAGE3 CONFIGURATION
(8 REGISTERS)
ADDR 0x0A8
ADDR 0x0B8
ADDR 0x090
STAGE7 CONFIGURATION
(8 REGISTERS)
ADDR 0x018
PROXIMITY STATUS REGISTER
(1 REGISTER)
STAGE5 RESULTS
(36 REGISTERS)
ADDR 0x0B0
ADDR 0x0B8
STAGE6 RESULTS
(36 REGISTERS)
STAGE7 RESULTS
(36 REGISTERS)
STAGE8 RESULTS
(36 REGISTERS)
STAGE9 RESULTS
(36 REGISTERS)
STAGE9 CONFIGURATION
(8 REGISTERS)
ADDR 0x0D0
STAGE10 RESULTS
(36 REGISTERS)
STAGE10 CONFIGURATION
(8 REGISTERS)
INVALID DO NOT ACCESS
STAGE4 RESULTS
(36 REGISTERS)
ADDR 0x0C8
ADDR 0x0C8
ADDR 0x0D0
ADDR 0x043
STAGE2 RESULTS
(36 REGISTERS)
ADDR 0x0A8
STAGE8 CONFIGURATION
(8 REGISTERS)
INVALID DO NOT ACCESS
STAGE1 RESULTS
(36 REGISTERS)
ADDR 0x0C0
ADDR 0x0C0
ADDR 0x042
STAGE0 RESULTS
(36 REGISTERS)
STAGE3 RESULTS
(36 REGISTERS)
ADDR 0x0A0
432 REGISTERS
ADDR 0x090
ADDR 0x005
ADDR 0x00B
BANK 3 REGISTERS
ADDR 0x0E0
STAGE0 CONFIGURATION
(8 REGISTERS)
STAGE1 CONFIGURATION
(8 REGISTERS)
CALIBRATION AND SETUP
(4 REGISTERS)
INTERRUPT STATUS
(3 REGISTERS)
Default values are undefined for Bank 2 registers and Bank 3
registers until after power-up and configuration of the Bank 2
registers.
ADDR 0x0D8
ADDR 0x28F
STAGE11 CONFIGURATION
(8 REGISTERS)
ADDR 0x7F0
Figure 62. Layout of Bank 1, Bank 2, and Bank 3 Registers
Rev. E | Page 42 of 70
STAGE11 RESULTS
(36 REGISTERS)
06663-059
BANK 1 REGISTERS
ADDR 0x000
Bank 3 registers contain the results of each conversion stage.
These registers automatically update at the end of each conversion
sequence. Although these registers are primarily used by the
AD7147 internal data processing, they are accessible by the host
processor for additional external data processing, if desired.
Data Sheet
AD7147
DETAILED REGISTER DESCRIPTIONS
BANK 1 REGISTERS
All addresses and default values are expressed in hexadecimal.
Table 20. PWR_CONTROL Register
Address
0x000
Data Bit
[1:0]
Default
Value
0
Type
R/W
Name
POWER_MODE
[3:2]
0
R/W
LP_CONV_DELAY
[7:4]
0
R/W
SEQUENCE_STAGE_NUM
[9:8]
0
R/W
DECIMATION
[10]
0
R/W
SW_RESET
[11]
0
R/W
INT_POL
[12]
0
R/W
EXT_SOURCE
[13]
[15:14]
0
0
R/W
Unused
CDC_BIAS
Rev. E | Page 43 of 70
Description
Operating modes
00 = full power mode (normal operation, CDC
conversions approximately every 36 ms)
01 = full shutdown mode (no CDC conversions)
10 = low power mode (automatic wake-up operation)
11 = full shutdown mode (no CDC conversions)
Low power mode conversion delay
00 = 200 ms
01 = 400 ms
10 = 600 ms
11 = 800 ms
Number of stages in sequence (N + 1)
0000 = 1 conversion stage in sequence
0001 = 2 conversion stages in sequence
…
Maximum value = 1011 = 12 conversion stages per
sequence
ADC decimation factor
00 = decimate by 256
01 = decimate by 128
10 = decimate by 64
11 = decimate by 64
Software reset control (self-clearing)
1 = resets all registers to default values
Interrupt polarity control
0 = active low
1 = active high
Excitation source control
0 = enable excitation source to CINx pins
1 = disable excitation source to CINx pins
Set to 0
CDC bias current control
00 = normal operation
01 = normal operation + 20%
10 = normal operation + 35%
11 = normal operation + 50%
AD7147
Data Sheet
Table 21. STAGE_CAL_EN Register
Address
0x001
Data Bit
[0]
Default
Value
0
Type
R/W
Name
STAGE0_CAL_EN
[1]
0
R/W
STAGE1_CAL_EN
[2]
0
R/W
STAGE2_CAL_EN
[3]
0
R/W
STAGE3_CAL_EN
[4]
0
R/W
STAGE4_CAL_EN
[5]
0
R/W
STAGE5_CAL_EN
[6]
0
R/W
STAGE6_CAL_EN
[7]
0
R/W
STAGE7_CAL_EN
[8]
0
R/W
STAGE8_CAL_EN
[9]
0
R/W
STAGE9_CAL_EN
[10]
0
R/W
STAGE10_CAL_EN
[11]
0
R/W
STAGE11_CAL_EN
[13:12]
0
R/W
AVG_FP_SKIP
[15:14]
0
R/W
AVG_LP_SKIP
Rev. E | Page 44 of 70
Description
STAGE0 calibration enable
0 = disable
1 = enable
STAGE1 calibration enable
0 = disable
1 = enable
STAGE2 calibration enable
0 = disable
1 = enable
STAGE3 calibration enable
0 = disable
1 = enable
STAGE4 calibration enable
0 = disable
1 = enable
STAGE5 calibration enable
0 = disable
1 = enable
STAGE6 calibration enable
0 = disable
1 = enable
STAGE7 calibration enable
0 = disable
1 = enable
STAGE8 calibration enable
0 = disable
1 = enable
STAGE9 calibration enable
0 = disable
1 = enable
STAGE10 calibration enable
0 = disable
1 = enable
STAGE11 calibration enable
0 = disable
1 = enable
Full power mode skip control
00 = skip 3 samples
01 = skip 7 samples
10 = skip 15 samples
11 = skip 31 samples
Low power mode skip control
00 = use all samples
01 = skip one sample
10 = skip two samples
11 = skip three samples
Data Sheet
AD7147
Table 22. AMB_COMP_CTRL0 Register
Address
0x002
Data Bit
[3:0]
Default
Value
0
Type
R/W
Name
FF_SKIP_CNT
[7:4]
F
R/W
FP_PROXIMITY_CNT
[11:8]
F
R/W
LP_PROXIMITY_CNT
[13:12]
0
R/W
PWR_DOWN_TIMEOUT
[14]
0
R/W
FORCED_CAL
[15]
0
R/W
CONV_RESET
Description
Fast filter skip control (N + 1)
0000 = no sequence of results is skipped
0001 = one sequence of results is skipped for every one
allowed into fast FIFO
0010 = two sequences of results are skipped for every
one allowed into fast FIFO
1011 = maximum value = 12 sequences of results are
skipped for every one allowed into fast FIFO
Calibration disable period in full power mode =
FP_PROXIMITY_CNT × 16 × time for one conversion
sequence in full power mode
Calibration disable period in low power mode =
LP_PROXIMITY_CNT × 4 × time for one conversion
sequence in low power mode
Full power to low power mode timeout control
00 = 1.25 × (FP_PROXIMITY_CNT)
01 = 1.50 × (FP_PROXIMITY_CNT)
10 = 1.75 × (FP_PROXIMITY_CNT)
11 = 2.00 × (FP_PROXIMITY_CNT)
Forced calibration control
0 = normal operation
1 = forces all conversion stages to recalibrate
Conversion reset control (self-clearing)
0 = normal operation
1 = resets the conversion sequence to STAGE0
Table 23. AMB_COMP_CTRL1 Register
Address
0x003
Data Bit
[7:0]
Default
Value
64
Type
R/W
Name
PROXIMITY_RECAL_LVL
[13:8]
1
R/W
PROXIMITY_DETECTION_RATE
[15:14]
0
R/W
SLOW_FILTER_UPDATE_LVL
Description
Proximity recalibration level; the value is multiplied by
16 to determine actual recalibration level
Proximity detection rate; the value is multiplied by 16 to
determine actual detection rate
Slow filter update level
Name
FP_PROXIMITY_RECAL
LP_PROXIMITY_RECAL
Description
Full power mode proximity recalibration time control
Low power mode proximity recalibration time control
Table 24. AMB_COMP_CTRL2 Register
Address
0x004
Data Bit
[9:0]
[15:10]
Default
Value
3FF
3F
Type
R/W
R/W
Rev. E | Page 45 of 70
AD7147
Data Sheet
Table 25. STAGE_LOW_INT_ENABLE Register
Address
0x005
Data Bit
[0]
Default
Value
0
Type
R/W
Name
STAGE0_LOW_INT_ENABLE
[1]
0
R/W
STAGE1_LOW_INT_ENABLE
[2]
0
R/W
STAGE2_LOW_INT_ENABLE
[3]
0
R/W
STAGE3_LOW_INT_ENABLE
[4]
0
R/W
STAGE4_LOW_INT_ENABLE
[5]
0
R/W
STAGE5_LOW_INT_ENABLE
[6]
0
R/W
STAGE6_LOW_INT_ENABLE
[7]
0
R/W
STAGE7_LOW_INT_ENABLE
[8]
0
R/W
STAGE8_LOW_INT_ENABLE
[9]
0
R/W
STAGE9_LOW_INT_ENABLE
[10]
0
R/W
STAGE10_LOW_INT_ENABLE
[11]
0
R/W
STAGE11_LOW_INT_ENABLE
[13:12]
0
R/W
GPIO_SETUP
[15:14]
0
R/W
GPIO_INPUT_CONFIG
Rev. E | Page 46 of 70
Description
STAGE0 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE0 low threshold is exceeded
STAGE1 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE1 low threshold is exceeded
STAGE2 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE2 low threshold is exceeded
STAGE3 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE3 low threshold is exceeded
STAGE4 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE4 low threshold is exceeded
STAGE5 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE5 low threshold is exceeded
STAGE6 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE6 low threshold is exceeded
STAGE7 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE7 low threshold is exceeded
STAGE8 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE8 low threshold is exceeded
STAGE9 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE9 low threshold is exceeded
STAGE10 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE10 low threshold is exceeded
STAGE11 low interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE11 low threshold is exceeded
GPIO setup
00 = disable GPIO pin
01 = configure GPIO as an input
10 = configure GPIO as an active low output
11 = configure GPIO as an active high output
GPIO input configuration
00 = triggered on negative level
01 = triggered on positive edge
10 = triggered on negative edge
11 = triggered on positive level
Data Sheet
AD7147
Table 26. STAGE_HIGH_INT_ENABLE Register
Address
0x006
Data Bit
[0]
Default
Value
0
Type
R/W
Name
STAGE0_HIGH_INT_ENABLE
[1]
0
R/W
STAGE1_HIGH_INT_ENABLE
[2]
0
R/W
STAGE2_HIGH_INT_ENABLE
[3]
0
R/W
STAGE3_HIGH_INT_ENABLE
[4]
0
R/W
STAGE4_HIGH_INT_ENABLE
[5]
0
R/W
STAGE5_HIGH_INT_ENABLE
[6]
0
R/W
STAGE6_HIGH_INT_ENABLE
[7]
0
R/W
STAGE7_HIGH_INT_ENABLE
[8]
0
R/W
STAGE8_HIGH_INT_ENABLE
[9]
0
R/W
STAGE9_HIGH_INT_ENABLE
[10]
0
R/W
STAGE10_HIGH_INT_ENABLE
[11]
0
R/W
STAGE11_HIGH_INT_ENABLE
[15:12]
Unused
Rev. E | Page 47 of 70
Description
STAGE0 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE0 high threshold is exceeded
STAGE1 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE1 high threshold is exceeded
STAGE2 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE2 high threshold is exceeded
STAGE3 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE3 high threshold is exceeded
STAGE4 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE4 high threshold is exceeded
STAGE5 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE5 high threshold is exceeded
STAGE6 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE6 high threshold is exceeded
STAGE7 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE7 high threshold is exceeded
STAGE8 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE8 high threshold is exceeded
STAGE9 sensor high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE9 high threshold is exceeded
STAGE10 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE10 high threshold is exceeded
STAGE11 high interrupt enable
0 = interrupt source disabled
1 = INT asserted if STAGE11 high threshold is exceeded
Set to 0
AD7147
Data Sheet
Table 27. STAGE_COMPLETE_INT_ENABLE Register
Address
0x007
Data Bit
[0]
Default
Value
0
Type
R/W
Name
STAGE0_COMPLETE_INT_ENABLE
[1]
0
R/W
STAGE1_COMPLETE_INT_ENABLE
[2]
0
R/W
STAGE2_COMPLETE_INT_ENABLE
[3]
0
R/W
STAGE3_COMPLETE_INT_ENABLE
[4]
0
R/W
STAGE4_COMPLETE_INT_ENABLE
[5]
0
R/W
STAGE5_COMPLETE_INT_ENABLE
[6]
0
R/W
STAGE6_COMPLETE_INT_ENABLE
[7]
0
R/W
STAGE7_COMPLETE_INT_ENABLE
[8]
0
R/W
STAGE8_COMPLETE_INT_ENABLE
[9]
0
R/W
STAGE9_COMPLETE_INT_ENABLE
[10]
0
R/W
STAGE10_COMPLETE_INT_ENABLE
[11]
0
R/W
STAGE11_COMPLETE_INT_ENABLE
[12]
0
R/W
GPIO_INT_ENABLE
[15:13]
Unused
Rev. E | Page 48 of 70
Description
STAGE0 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE0 conversion
STAGE1 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE1 conversion
STAGE2 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE2 conversion
STAGE3 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE3 conversion
STAGE4 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE4 conversion
STAGE5 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE5 conversion
STAGE6 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE6 conversion
STAGE7 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE7 conversion
STAGE8 conversion complete interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE8 conversion
STAGE9 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE9 conversion
STAGE10 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE10 conversion
STAGE11 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE11 conversion
Interrupt control when GPIO input pin changes level
0 = disabled
1 = enabled
Set to 0
Data Sheet
AD7147
Table 28. STAGE_LOW_INT_STATUS Register1
Address
0x008
Data Bit
[0]
Default
Value
0
Type
R
Name
STAGE0_LOW_INT_STATUS
[1]
0
R
STAGE1_LOW_INT_STATUS
[2]
0
R
STAGE2_LOW_INT_STATUS
[3]
0
R
STAGE3_LOW_INT_STATUS
[4]
0
R
STAGE4_LOW_INT_STATUS
[5]
0
R
STAGE5_LOW_INT_STATUS
[6]
0
R
STAGE6_LOW_INT_STATUS
[7]
0
R
STAGE7_LOW_INT_STATUS
[8]
0
R
STAGE8_LOW_INT_STATUS
[9]
0
R
STAGE9_LOW_INT_STATUS
[10]
0
R
STAGE10_LOW_INT_STATUS
[11]
0
R
STAGE11_LOW_INT_STATUS
[15:12]
1
Unused
Registers self-clear to 0 after readback if the limits are not exceeded.
Rev. E | Page 49 of 70
Description
STAGE0 CDC conversion low limit interrupt result
1 = indicates STAGE0_LOW_THRESHOLD value was
exceeded
STAGE1 CDC conversion low limit interrupt result
1 = indicates STAGE1_LOW_THRESHOLD value was
exceeded
STAGE2 CDC conversion low limit interrupt result
1 = indicates STAGE2_LOW_THRESHOLD value was
exceeded
STAGE3 CDC conversion low limit interrupt result
1 = indicates STAGE3_LOW_THRESHOLD value was
exceeded
STAGE4 CDC conversion low limit interrupt result
1 = indicates STAGE4_LOW_THRESHOLD value was
exceeded
STAGE5 CDC conversion low limit interrupt result
1 = indicates STAGE5_LOW_THRESHOLD value was
exceeded
STAGE6 CDC conversion low limit interrupt result
1 = indicates STAGE6_LOW_THRESHOLD value was
exceeded
STAGE7 CDC conversion low limit interrupt result
1 = indicates STAGE7_LOW_THRESHOLD value was
exceeded
STAGE8 CDC conversion low limit interrupt result
1 = indicates STAGE8_LOW_THRESHOLD value was
exceeded
STAGE9 CDC conversion low limit interrupt result
1 = indicates STAGE9_LOW_THRESHOLD value was
exceeded
STAGE10 CDC Conversion Low Limit Interrupt result
1 = indicates STAGE10_LOW_THRESHOLD value was
exceeded
STAGE11 CDC conversion low limit interrupt result
1 = indicates STAGE11_LOW_THRESHOLD value was
exceeded
Set to 0
AD7147
Data Sheet
Table 29. STAGE_HIGH_INT_STATUS Register1
Address
0x009
Data Bit
[0]
Default
Value
0
Type
R
Name
STAGE0_HIGH_INT_STATUS
[1]
0
R
STAGE1_HIGH_INT_STATUS
[2]
0
R
STAGE2_HIGH_INT_STATUS
[3]
0
R
STAGE3_HIGH_INT_STATUS
[4]
0
R
STAGE4_HIGH_INT_STATUS
[5]
0
R
STAGE5_HIGH_INT_STATUS
[6]
0
R
STAGE6_HIGH_INT_STATUS
[7]
0
R
STAGE7_HIGH_INT_STATUS
[8]
0
R
STAGE8_HIGH_INT_STATUS
[9]
0
R
STAGE9_HIGH_INT_STATUS
[10]
0
R
STAGE10_HIGH_INT_STATUS
[11]
0
R
STAGE11_HIGH_INT_STATUS
[15:12]
1
Unused
Registers self-clear to 0 after readback if the limits are not exceeded.
Rev. E | Page 50 of 70
Description
STAGE0 CDC conversion high limit interrupt result
1 = indicates STAGE0_HIGH_THRESHOLD value was
exceeded
STAGE1 CDC conversion high limit interrupt result
1 = indicates STAGE1_HIGH_THRESHOLD value was
exceeded
Stage2 CDC conversion high limit interrupt result
1 = indicates STAGE2_HIGH_THRESHOLD value was
exceeded
STAGE3 CDC conversion high limit interrupt result
1 = indicates STAGE3_HIGH_THRESHOLD value was
exceeded
STAGE4 CDC conversion high limit interrupt result
1 = indicates STAGE4_HIGH_THRESHOLD value was
exceeded
STAGE5 CDC conversion high limit interrupt result
1 = indicates STAGE5_HIGH_THRESHOLD value was
exceeded
STAGE6 CDC conversion high limit interrupt result
1 = indicates STAGE6_HIGH_THRESHOLD value was
exceeded
STAGE7 CDC conversion high limit interrupt result
1 = indicates STAGE7_HIGH_THRESHOLD value was
exceeded
STAGE8 CDC conversion high limit interrupt result
1 = indicates STAGE8_HIGH_THRESHOLD value was
exceeded
STAGE9 CDC conversion high limit interrupt result
1 = indicates STAGE9_HIGH_THRESHOLD value was
exceeded
STAGE10 CDC conversion high limit interrupt result
1 = indicates STAGE10_HIGH_THRESHOLD value was
exceeded
STAGE11 CDC conversion high limit interrupt result
1 = indicates STAGE11_HIGH_THRESHOLD value was
exceeded
Set to 0
Data Sheet
AD7147
Table 30. STAGE_COMPLETE_INT_STATUS Register1
Address
0x00A
Data Bit
[0]
Default
Value
0
Type
R
Name
STAGE0_COMPLETE_INT_STATUS
[1]
0
R
STAGE1_COMPLETE_INT_STATUS
[2]
0
R
STAGE2_COMPLETE_INT_STATUS
[3]
0
R
STAGE3_COMPLETE_INT_STATUS
[4]
0
R
STAGE4_COMPLETE_INT_STATUS
[5]
0
R
STAGE5_COMPLETE_INT_STATUS
[6]
0
R
STAGE6_COMPLETE_INT_STATUS
[7]
0
R
STAGE7_COMPLETE_INT_STATUS
[8]
0
R
STAGE8_COMPLETE_INT_STATUS
[9]
0
R
STAGE9_COMPLETE_INT_STATUS
[10]
0
R
STAGE10_COMPLETE_INT_STATUS
[11]
0
R
STAGE11_COMPLETE_INT_STATUS
[12]
0
R
GPIO_INT_STATUS
[15:13]
1
Unused
Description
STAGE0 conversion complete register interrupt status
1 = indicates STAGE0 conversion completed
STAGE1 conversion complete register interrupt status
1 = indicates STAGE1 conversion completed
STAGE2 conversion complete register interrupt status
1 = indicates STAGE2 conversion completed
STAGE3 conversion complete register interrupt status
1 = indicates STAGE3 conversion completed
STAGE4 conversion complete register interrupt status
1 = indicates STAGE4 conversion completed
STAGE5 conversion complete register interrupt status
1 = indicates STAGE5 conversion completed
STAGE6 conversion complete register interrupt status
1 = indicates STAGE6 conversion completed
STAGE7 conversion complete register interrupt status
1 = indicates STAGE7 conversion completed
STAGE8 conversion complete register interrupt status
1 = indicates STAGE8 conversion completed
STAGE9 conversion complete register interrupt status
1 = indicates STAGE9 conversion completed
STAGE10 conversion complete register interrupt status
1 = indicates STAGE10 conversion completed
STAGE11 conversion complete register interrupt status
1 = indicates STAGE11 conversion completed
GPIO input pin status
1 = indicates level on GPIO pin has changed
Set to 0
Registers self-clear to 0 after readback if the limits are not exceeded.
Table 31. CDC 16-Bit Conversion Data Registers
Address
0x00B
0x00C
0x00D
0x00E
0x00F
0x010
0x011
0x012
0x013
0x014
0x015
0x016
Data Bit
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
Default
Value
0
0
0
0
0
0
0
0
0
0
0
0
Type
R
R
R
R
R
R
R
R
R
R
R
R
Name
CDC_RESULT_S0
CDC_RESULT_S1
CDC_RESULT_S2
CDC_RESULT_S3
CDC_RESULT_S4
CDC_RESULT_S5
CDC_RESULT_S6
CDC_RESULT_S7
CDC_RESULT_S8
CDC_RESULT_S9
CDC_RESULT_S10
CDC_RESULT_S11
Rev. E | Page 51 of 70
Description
STAGE0 CDC 16-bit conversion data
STAGE1 CDC 16-bit conversion data
STAGE2 CDC 16-bit conversion data
STAGE3 CDC 16-bit conversion data
STAGE4 CDC 16-bit conversion data
STAGE5 CDC 16-bit conversion data
STAGE6 CDC 16-bit conversion data
STAGE7 CDC 16-bit conversion data
STAGE8 CDC 16-bit conversion data
STAGE9 CDC 16-bit conversion data
STAGE10 CDC 16-bit conversion data
STAGE11 CDC 16-bit conversion data
AD7147
Data Sheet
Table 32. Device ID Register
Address
0x017
Data Bit
[3:0]
[15:4]
Default
Value
0
147
Type
R
R
Name
REVISION_CODE
DEVID
Description
Revision code
Device ID = 0001 0100 0111
Description
STAGE0 proximity status register
1 = indicates proximity has been detected on STAGE0
STAGE1 proximity status register
1 = indicates proximity has been detected on STAGE1
STAGE2 proximity status register
1 = indicates proximity has been detected on STAGE2
STAGE3 proximity status register
1 = indicates proximity has been detected on STAGE3
STAGE4 proximity status register
1 = indicates proximity has been detected on STAGE4
STAGE5 proximity status register
1 = indicates proximity has been detected on STAGE5
STAGE6 proximity status register
1 = indicates proximity has been detected on STAGE6
STAGE7 proximity status register
1 = indicates proximity has been detected on STAGE7
STAGE8 proximity status register
1 = indicates proximity has been detected on STAGE8
STAGE9 proximity status register
1 = indicates proximity has been detected on STAGE9
STAGE10 proximity status register
1 = indicates proximity has been detected on STAGE10
STAGE11 proximity status register
1 = indicates proximity has been detected on STAGE11
Set to 0
Table 33. Proximity Status Register
Address
0x042
Data Bit
[0]
Default
Value
0
Type
R
Name
STAGE0_PROXIMITY_STATUS
[1]
0
R
STAGE1_PROXIMITY_STATUS
[2]
0
R
STAGE2_PROXIMITY_STATUS
[3]
0
R
STAGE3_PROXIMITY_STATUS
[4]
0
R
STAGE4_PROXIMITY_STATUS
[5]
0
R
STAGE5_PROXIMITY_STATUS
[6]
0
R
STAGE6_PROXIMITY_STATUS
[7]
0
R
STAGE7_PROXIMITY_STATUS
[8]
0
R
STAGE8_PROXIMITY_STATUS
[9]
0
R
STAGE9_PROXIMITY_STATUS
[10]
0
R
STAGE10_PROXIMITY_STATUS
[11]
0
R
STAGE11_PROXIMITY_STATUS
[15:12]
Unused
Rev. E | Page 52 of 70
Data Sheet
AD7147
BANK 2 REGISTERS
All address values are expressed in hexadecimal.
Table 34. STAGEx_CONNECTION[6:0] Register Description (x = 0 to 11)
Data Bit
[1:0]
Default
Value
X
Type
R/W
Name
CIN0_CONNECTION_SETUP
[3:2]
X
R/W
CIN1_CONNECTION_SETUP
[5:4]
X
R/W
CIN2_CONNECTION_SETUP
[7:6]
X
R/W
CIN3_CONNECTION_SETUP
[9:8]
X
R/W
CIN4_CONNECTION_SETUP
[11:10]
X
R/W
CIN5_CONNECTION_SETUP
[13:12]
X
R/W
CIN6_CONNECTION_SETUP
[15:14]
X
Unused
Description
CIN0 connection setup
00 = CIN0 not connected to CDC inputs
01 = CIN0 connected to CDC negative input
10 = CIN0 connected to CDC positive input
11 = CIN0 connected to BIAS (connect unused CINx inputs)
CIN1 connection setup
00 = CIN1 not connected to CDC inputs
01 = CIN1 connected to CDC negative input
10 = CIN1 connected to CDC positive input
11 = CIN1 connected to BIAS (connect unused CINx inputs)
CIN2 connection setup
00 = CIN2 not connected to CDC inputs
01 = CIN2 connected to CDC negative input
10 = CIN2 connected to CDC positive input
11 = CIN2 connected to BIAS (connect unused CINx inputs)
CIN3 connection setup
00 = CIN3 not connected to CDC inputs
01 = CIN3 connected to CDC negative input
10 = CIN3 connected to CDC positive input
11 = CIN3 connected to BIAS (connect unused CINx inputs)
CIN4 connection setup
00 = CIN4 not connected to CDC inputs
01 = CIN4 connected to CDC negative input
10 = CIN4 connected to CDC positive input
11 = CIN4 connected to BIAS (connect unused CINx inputs)
CIN5 connection setup
00 = CIN5 not connected to CDC inputs
01 = CIN5 connected to CDC negative input
10 = CIN5 connected to CDC positive input
11 = CIN5 connected to BIAS (connect unused CINx inputs)
CIN6 connection setup
00 = CIN6 not connected to CDC inputs
01 = CIN6 connected to CDC negative input
10 = CIN6 connected to CDC positive input
11 = CIN6 connected to BIAS (connect unused CINx inputs)
Set to 0
Rev. E | Page 53 of 70
AD7147
Data Sheet
Table 35. STAGEx_CONNECTION[12:7] Register Description (x = 0 to 11)
Data Bit
[1:0]
Default
Value
X
Type
R/W
Name
CIN7_CONNECTION_SETUP
[3:2]
X
R/W
CIN8_CONNECTION_SETUP
[5:4]
X
R/W
CIN9_CONNECTION_SETUP
[7:6]
X
R/W
CIN10_CONNECTION_SETUP
[9:8]
X
R/W
CIN11_CONNECTION_SETUP
[11:10]
X
R/W
CIN12_CONNECTION_SETUP
[13:12]
X
R/W
SE_CONNECTION_SETUP
[14]
X
R/W
NEG_AFE_OFFSET_DISABLE
[15]
X
R/W
POS_AFE_OFFSET_DISABLE
Description
CIN7 connection setup
00 = CIN7 not connected to CDC inputs
01 = CIN7 connected to CDC negative input
10 = CIN7 connected to CDC positive input
11 = CIN7 connected to BIAS (connect unused CINx inputs)
CIN8 connection setup
00 = CIN8 not connected to CDC inputs
01 = CIN8 connected to CDC negative input
10 = CIN8 connected to CDC positive input
11 = CIN8 connected to BIAS (connect unused CINx inputs)
CIN9 connection setup
00 = CIN9 not connected to CDC inputs
01 = CIN9 connected to CDC negative input
10 = CIN9 connected to CDC positive input
11 = CIN9 connected to BIAS (connect unused CINx inputs)
CIN10 connection setup
00 = CIN10 not connected to CDC inputs
01 = CIN10 connected to CDC negative input
10 = CIN10 connected to CDC positive input
11 = CIN10 connected to BIAS (connect unused CINx inputs)
CIN11 connection setup
00 = CIN11 not connected to CDC inputs
01 = CIN11 connected to CDC negative input
10 = CIN11 connected to CDC positive input
11 = CIN11 connected to BIAS (connect unused CINx inputs)
CIN12 connection setup
00 = CIN12 not connected to CDC inputs
01 = CIN12 connected to CDC negative input
10 = CIN12 connected to CDC positive input
11 = CIN12 connected to BIAS (connect unused CINx inputs)
Single-ended measurement connection setup
00 = do not use
01 = use when one CINx connected to CDC positive input,
single-ended measurements only
10 = use when one CINx connected to CDC negative input,
single-ended measurements only
11 = differential connection to CDC
Negative AFE offset enable control
0 = enable
1 = disable
Positive AFE offset enable control
0 = enable
1 = disable
Rev. E | Page 54 of 70
Data Sheet
AD7147
Table 36. STAGEx_AFE_OFFSET Register Description (x = 0 to 11)
Data Bit
[5:0]
Default
Value
X
Type
R/W
Name
NEG_AFE_OFFSET
[6]
[7]
X
X
R/W
Unused
NEG_AFE_OFFSET_SWAP
[13:8]
X
R/W
POS_AFE_OFFSET
[14]
[15]
X
X
R/W
Unused
POS_AFE_OFFSET_SWAP
Description
Negative AFE offset setting (20 pF range)
1 LSB value = 0.32 pF of offset
Set to 0
Negative AFE offset swap control
0 = NEG_AFE_OFFSET applied to CDC negative input
1 = NEG_AFE_OFFSET applied to CDC positive input
Positive AFE offset setting (20 pF range)
1 LSB value = 0.32 pF of offset
Set to 0
Positive AFE offset swap control
0 = POS_AFE_OFFSET applied to CDC positive input
1 = POS_AFE_OFFSET applied to CDC negative input
Table 37. STAGEx_SENSITIVITY Register Description (x = 0 to 11)
Data Bit
[3:0]
Default
Value
X
Type
R/W
Name
NEG_THRESHOLD_SENSITIVITY
[6:4]
X
R/W
NEG_PEAK_DETECT
[7]
[11:8]
X
X
R/W
R/W
Unused
POS_THRESHOLD_SENSITIVITY
[14:12]
X
R/W
POS_PEAK_DETECT
[15]
X
R/W
Unused
Description
Negative threshold sensitivity control
0000 = 25%, 0001 = 29.73%, 0010 = 34.40%, 0011 = 39.08%
0100 = 43.79%, 0101 = 48.47%, 0110 = 53.15%
0111 = 57.83%, 1000 = 62.51%, 1001 = 67.22%
1010 = 71.90%, 1011 = 76.58%, 1100 = 81.28%
1101 = 85.96%, 1110 = 90.64%, 1111 = 95.32%
Negative peak detect setting
000 = 40% level, 001 = 50% level, 010 = 60% level
011 = 70% level, 100 = 80% level, 101 = 90% level
Set to 0
Positive threshold sensitivity control
0000 = 25%, 0001 = 29.73%, 0010 = 34.40%, 0011 = 39.08%
0100 = 43.79%, 0101 = 48.47%, 0110 = 53.15%
0111 = 57.83%, 1000 = 62.51%, 1001 = 67.22%
1010 = 71.90%, 1011 = 76.58%, 1100 = 81.28%
1101 = 85.96%, 1110 = 90.64%, 1111 = 95.32%
Positive peak detect setting
000 = 40% level, 001 = 50% level, 010 = 60% level
011 = 70% level, 100 = 80% level, 101 = 90% level
Set to 0
Rev. E | Page 55 of 70
AD7147
Data Sheet
Table 38. STAGE0 to STAGE11 Configuration Registers
Address
0x080
0x081
0x082
0x083
0x084
0x085
0x086
0x087
0x088
0x089
0x08A
0x08B
0x08C
0x08D
0x08E
0x08F
0x090
0x091
0x092
0x093
0x094
0x095
0x096
0x097
0x098
0x099
0x09A
0x09B
0x09C
0x09D
0x09E
0x09F
0x0A0
0x0A1
0x0A2
0x0A3
0x0A4
0x0A5
0x0A6
0x0A7
0x0A8
0x0A9
0x0AA
0x0AB
0x0AC
0x0AD
0x0AE
0x0AF
Data Bit
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Name
STAGE0_CONNECTION[6:0]
STAGE0_CONNECTION[12:7]
STAGE0_AFE_OFFSET
STAGE0_SENSITIVITY
STAGE0_OFFSET_LOW
STAGE0_OFFSET_HIGH
STAGE0_OFFSET_HIGH_CLAMP
STAGE0_OFFSET_LOW_CLAMP
STAGE1_CONNECTION[6:0]
STAGE1_CONNECTION[12:7]
STAGE1_AFE_OFFSET
STAGE1_SENSITIVITY
STAGE1_OFFSET_LOW
STAGE1_OFFSET_HIGH
STAGE1_OFFSET_HIGH_CLAMP
STAGE1_OFFSET_LOW_CLAMP
STAGE2_CONNECTION[6:0]
STAGE2_CONNECTION[12:7]
STAGE2_AFE_OFFSET
STAGE2_SENSITIVITY
STAGE2_OFFSET_LOW
STAGE2_OFFSET_HIGH
STAGE2_OFFSET_HIGH_CLAMP
STAGE2_OFFSET_LOW_CLAMP
STAGE3_CONNECTION[6:0]
STAGE3_CONNECTION[12:7]
STAGE3_AFE_OFFSET
STAGE3_SENSITIVITY
STAGE3_OFFSET_LOW
STAGE3_OFFSET_HIGH
STAGE3_OFFSET_HIGH_CLAMP
STAGE3_OFFSET_LOW_CLAMP
STAGE4_CONNECTION[6:0]
STAGE4_CONNECTION[12:7]
STAGE4_AFE_OFFSET
STAGE4_SENSITIVITY
STAGE4_OFFSET_LOW
STAGE4_OFFSET_HIGH
STAGE4_OFFSET_HIGH_CLAMP
STAGE4_OFFSET_LOW_CLAMP
STAGE5_CONNECTION[6:0]
STAGE5_CONNECTION[12:7]
STAGE5_AFE_OFFSET
STAGE5_SENSITIVITY
STAGE5_OFFSET_LOW
STAGE5_OFFSET_HIGH
STAGE5_OFFSET_HIGH_CLAMP
STAGE5_OFFSET_LOW_CLAMP
Rev. E | Page 56 of 70
Description
STAGE0 CIN[6:0] connection setup (see Table 34)
STAGE0 CIN[12:7] connection setup (see Table 35)
STAGE0 AFE offset control (see Table 36)
STAGE0 sensitivity control (see Table 37)
STAGE0 initial offset low value
STAGE0 initial offset high value
STAGE0 offset high clamp value
STAGE0 offset low clamp value
STAGE1 CIN[6:0] connection setup (see Table 34)
STAGE1 CIN[12:7] connection setup (see Table 35)
STAGE1 AFE offset control (see Table 36)
STAGE1 sensitivity control (see Table 37)
STAGE1 initial offset low value
STAGE1 initial offset high value
STAGE1 offset high clamp value
STAGE1 offset low clamp value
STAGE2 CIN[6:0] connection setup (see Table 34)
STAGE2 CIN[12:7] connection setup (see Table 35)
STAGE2 AFE offset control (see Table 36)
STAGE2 sensitivity control (see Table 37)
STAGE2 initial offset low value
STAGE2 initial offset high value
STAGE2 offset high clamp value
STAGE2 offset low clamp value
STAGE3 CIN[6:0] connection setup (see Table 34)
STAGE3 CIN[12:7] connection setup (see Table 35)
STAGE3 AFE offset control (see Table 36)
STAGE3 sensitivity control (see Table 37)
STAGE3 initial offset low value
STAGE3 initial offset high value
STAGE3 offset high clamp value
STAGE3 offset low clamp value
STAGE4 CIN[6:0] connection setup (see Table 34)
STAGE4 CIN[12:7] connection setup (see Table 35)
STAGE4 AFE offset control (see Table 36)
STAGE4 sensitivity control (see Table 37)
STAGE4 initial offset low value
STAGE4 initial offset high value
STAGE4 offset high clamp value
STAGE4 offset low clamp value
STAGE5 CIN[6:0] connection setup (see Table 34)
STAGE5 CIN[12:7] connection setup (see Table 35)
STAGE5 AFE offset control (see Table 36)
STAGE5 sensitivity control (see Table 37)
STAGE5 initial offset low value
STAGE5 initial offset high value
STAGE5 offset high clamp value
STAGE5 offset low clamp value
Data Sheet
Address
0x0B0
0x0B1
0x0B2
0x0B3
0x0B4
0x0B5
0x0B6
0x0B7
0x0B8
0x0B9
0x0BA
0x0BB
0x0BC
0x0BD
0x0BE
0x0BF
0x0C0
0x0C1
0x0C2
0x0C3
0x0C4
0x0C5
0x0C6
0x0C7
0x0C8
0x0C9
0x0CA
0x0CB
0x0CC
0x0CD
0x0CE
0x0CF
0x0D0
0x0D1
0x0D2
0x0D3
0x0D4
0x0D5
0x0D6
0x0D7
0x0D8
0x0D9
0x0DA
0x0DB
0x0DC
0x0DD
0x0DE
0x0DF
Data Bit
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
AD7147
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Name
STAGE6_CONNECTION[6:0]
STAGE6_CONNECTION[12:7]
STAGE6_AFE_OFFSET
STAGE6_SENSITIVITY
STAGE6_OFFSET_LOW
STAGE6_OFFSET_HIGH
STAGE6_OFFSET_HIGH_CLAMP
STAGE6_OFFSET_LOW_CLAMP
STAGE7_CONNECTION[6:0]
STAGE7_CONNECTION[12:7]
STAGE7_AFE_OFFSET
STAGE7_SENSITIVITY
STAGE7_OFFSET_LOW
STAGE7_OFFSET_HIGH
STAGE7_OFFSET_HIGH_CLAMP
STAGE7_OFFSET_LOW_CLAMP
STAGE8_CONNECTION[6:0]
STAGE8_CONNECTION[12:7]
STAGE8_AFE_OFFSET
STAGE8_SENSITIVITY
STAGE8_OFFSET_LOW
STAGE8_OFFSET_HIGH
STAGE8_OFFSET_HIGH_CLAMP
STAGE8_OFFSET_LOW_CLAMP
STAGE9_CONNECTION[6:0]
STAGE9_CONNECTION[12:7]
STAGE9_AFE_OFFSET
STAGE9_SENSITIVITY
STAGE9_OFFSET_LOW
STAGE9_OFFSET_HIGH
STAGE9_OFFSET_HIGH_CLAMP
STAGE9_OFFSET_LOW_CLAMP
STAGE10_CONNECTION[6:0]
STAGE10_CONNECTION[12:7]
STAGE10_AFE_OFFSET
STAGE10_SENSITIVITY
STAGE10_OFFSET_LOW
STAGE10_OFFSET_HIGH
STAGE10_OFFSET_HIGH_CLAMP
STAGE10_OFFSET_LOW_CLAMP
STAGE11_CONNECTION[6:0]
STAGE11_CONNECTION[12:7]
STAGE11_AFE_OFFSET
STAGE11_SENSITIVITY
STAGE11_OFFSET_LOW
STAGE11_OFFSET_HIGH
STAGE11_OFFSET_HIGH_CLAMP
STAGE11_OFFSET_LOW_CLAMP
Rev. E | Page 57 of 70
Description
STAGE6 CIN[6:0] connection setup (see Table 34)
STAGE6 CIN[12:7]connection setup (see Table 35)
STAGE6 AFE offset control (see Table 36)
STAGE6 sensitivity control (see Table 37)
STAGE6 initial offset low value
STAGE6 initial offset high value
STAGE6 offset high clamp value
STAGE6 offset low clamp value
STAGE7 CIN[6:0] connection setup (see Table 34)
STAGE7 CIN[12:7] connection setup (see Table 35)
STAGE7 AFE offset control (see Table 36)
STAGE7 sensitivity control (see Table 37)
STAGE7 initial offset low value
STAGE7 initial offset high value
STAGE7 offset high clamp value
STAGE7 offset low clamp value
STAGE8 CIN[6:0] connection setup (see Table 34)
STAGE8 CIN[12:7]connection setup (see Table 35)
STAGE8 AFE offset control (see Table 36)
STAGE8 sensitivity control (see Table 37)
STAGE8 initial offset low value
STAGE8 initial offset high value
STAGE8 offset high clamp value
STAGE8 offset low clamp value
STAGE9 CIN[6:0] connection setup (see Table 34)
STAGE9 CIN[12:7]connection setup (see Table 35)
STAGE9 AFE offset control (see Table 36)
STAGE9 sensitivity control (see Table 37)
STAGE9 initial offset low value
STAGE9 initial offset high value
STAGE9 offset high clamp value
STAGE9 offset low clamp value
STAGE10 CIN[6:0] connection setup (see Table 34)
STAGE10 CIN[12:7]connection setup (see Table 35)
STAGE10 AFE offset control (see Table 36)
STAGE10 sensitivity control (see Table 37)
STAGE10 initial offset low value
STAGE10 initial offset high value
STAGE10 offset high clamp value
STAGE10 offset low clamp value
STAGE11 CIN[6:0] connection setup (see Table 34)
STAGE11 CIN[12:7] connection setup (see Table 35)
STAGE11 AFE offset control (see Table 36)
STAGE11 sensitivity control (see Table 37)
STAGE11 initial offset low value
STAGE11 initial offset high value
STAGE11 offset high clamp value
STAGE11 offset low clamp value
AD7147
Data Sheet
BANK 3 REGISTERS
All address values are expressed in hexadecimal.
Table 39. STAGE0 Results Registers
Address
0x0E0
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE0_CONV_DATA
0x0E1
0x0E2
0x0E3
0x0E4
0x0E5
0x0E6
0x0E7
0x0E8
0x0E9
0x0EA
0x0EB
0x0EC
0x0ED
0x0EE
0x0EF
0x0F0
0x0F1
0x0F2
0x0F3
0x0F4
0x0F5
0x0F6
0x0F7
0x0F8
0x0F9
0x0FA
0x0FB
0x0FC
0x0FD
0x0FE
0x0FF
0x100
0x101
0x102
0x103
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE0_FF_WORD0
STAGE0_FF_WORD1
STAGE0_FF_WORD2
STAGE0_FF_WORD3
STAGE0_FF_WORD4
STAGE0_FF_WORD5
STAGE0_FF_WORD6
STAGE0_FF_WORD7
STAGE0_SF_WORD0
STAGE0_SF_WORD1
STAGE0_SF_WORD2
STAGE0_SF_WORD3
STAGE0_SF_WORD4
STAGE0_SF_WORD5
STAGE0_SF_WORD6
STAGE0_SF_WORD7
STAGE0_SF_AMBIENT
STAGE0_FF_AVG
STAGE0_PEAK_DETECT_WORD0
STAGE0_PEAK_DETECT_WORD1
STAGE0_MAX_WORD0
STAGE0_MAX_WORD1
STAGE0_MAX_WORD2
STAGE0_MAX_WORD3
STAGE0_MAX_AVG
STAGE0_HIGH_THRESHOLD
STAGE0_MAX_TEMP
STAGE0_MIN_WORD0
STAGE0_MIN_WORD1
STAGE0_MIN_WORD2
STAGE0_MIN_WORD3
STAGE0_MIN_AVG
STAGE0_LOW_THRESHOLD
STAGE0_MIN_TEMP
Unused
Rev. E | Page 58 of 70
Description
STAGE0 CDC 16-bit conversion data
(copy of CDC_RESULT_S0 register)
STAGE0 fast FIFO WORD0
STAGE0 fast FIFO WORD1
STAGE0 fast FIFO WORD2
STAGE0 fast FIFO WORD3
STAGE0 fast FIFO WORD4
STAGE0 fast FIFO WORD5
STAGE0 fast FIFO WORD6
STAGE0 fast FIFO WORD7
STAGE0 slow FIFO WORD0
STAGE0 slow FIFO WORD1
STAGE0 slow FIFO WORD2
STAGE0 slow FIFO WORD3
STAGE0 slow FIFO WORD4
STAGE0 slow FIFO WORD5
STAGE0 slow FIFO WORD6
STAGE0 slow FIFO WORD7
STAGE0 slow FIFO ambient value
STAGE0 fast FIFO average value
STAGE0 peak FIFO WORD0 value
STAGE0 peak FIFO WORD1 value
STAGE0 maximum value FIFO WORD0
STAGE0 maximum value FIFO WORD1
STAGE0 maximum value FIFO WORD2
STAGE0 maximum value FIFO WORD3
STAGE0 average maximum FIFO value
STAGE0 high threshold value
STAGE0 temporary maximum value
STAGE0 minimum value FIFO WORD0
STAGE0 minimum value FIFO WORD1
STAGE0 minimum value FIFO WORD2
STAGE0 minimum value FIFO WORD3
STAGE0 average minimum FIFO value
STAGE0 low threshold value
STAGE0 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 40. STAGE1 Results Registers
Address
0x104
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE1_CONV_DATA
0x105
0x106
0x107
0x108
0x109
0x10A
0x10B
0x10C
0x10D
0x10E
0x10F
0x110
0x111
0x112
0x113
0x114
0x115
0x116
0x117
0x118
0x119
0x11A
0x11B
0x11C
0x11D
0x11E
0x11F
0x120
0x121
0x122
0x123
0x124
0x125
0x126
0x127
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE1_FF_WORD0
STAGE1_FF_WORD1
STAGE1_FF_WORD2
STAGE1_FF_WORD3
STAGE1_FF_WORD4
STAGE1_FF_WORD5
STAGE1_FF_WORD6
STAGE1_FF_WORD7
STAGE1_SF_WORD0
STAGE1_SF_WORD1
STAGE1_SF_WORD2
STAGE1_SF_WORD3
STAGE1_SF_WORD4
STAGE1_SF_WORD5
STAGE1_SF_WORD6
STAGE1_SF_WORD7
STAGE1_SF_AMBIENT
STAGE1_FF_AVG
STAGE1_PEAK_DETECT_WORD0
STAGE1_PEAK_DETECT_WORD1
STAGE1_MAX_WORD0
STAGE1_MAX_WORD1
STAGE1_MAX_WORD2
STAGE1_MAX_WORD3
STAGE1_MAX_AVG
STAGE1_HIGH_THRESHOLD
STAGE1_MAX_TEMP
STAGE1_MIN_WORD0
STAGE1_MIN_WORD1
STAGE1_MIN_WORD2
STAGE1_MIN_WORD3
STAGE1_MIN_AVG
STAGE1_LOW_THRESHOLD
STAGE1_MIN_TEMP
Unused
Rev. E | Page 59 of 70
Description
STAGE1 CDC 16-bit conversion data
(copy of CDC_RESULT_S1 register
STAGE1 fast FIFO WORD0
STAGE1 fast FIFO WORD1
STAGE1 fast FIFO WORD2
STAGE1 fast FIFO WORD3
STAGE1 fast FIFO WORD4
STAGE1 fast FIFO WORD5
STAGE1 fast FIFO WORD6
STAGE1 fast FIFO WORD7
STAGE1 slow FIFO WORD0
STAGE1 slow FIFO WORD1
STAGE1 slow FIFO WORD2
STAGE1 slow FIFO WORD3
STAGE1 slow FIFO WORD4
STAGE1 slow FIFO WORD5
STAGE1 slow FIFO WORD6
STAGE1 slow FIFO WORD7
STAGE1 slow FIFO ambient value
STAGE1 fast FIFO average value
STAGE1 peak FIFO WORD0 value
STAGE1 peak FIFO WORD1 value
STAGE1 maximum value FIFO WORD0
STAGE1 maximum value FIFO WORD1
STAGE1 maximum value FIFO WORD2
STAGE1 maximum value FIFO WORD3
STAGE1 average maximum FIFO value
STAGE1 high threshold value
STAGE1 temporary maximum value
STAGE1 minimum value FIFO WORD0
STAGE1 minimum value FIFO WORD1
STAGE1 minimum value FIFO WORD2
STAGE1 minimum value FIFO WORD3
STAGE1 average minimum FIFO value
STAGE1 low threshold value
STAGE1 temporary minimum value
Set to 0
AD7147
Data Sheet
Table 41. STAGE2 Results Registers
Address
0x128
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE2_CONV_DATA
0x129
0x12A
0x12B
0x12C
0x12D
0x12E
0x12F
0x130
0x131
0x132
0x133
0x134
0x135
0x136
0x137
0x138
0x139
0x13A
0x13B
0x13C
0x13D
0x13E
0x13F
0x140
0x141
0x142
0x143
0x144
0x145
0x146
0x147
0x148
0x149
0x14A
0x14B
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE2_FF_WORD0
STAGE2_FF_WORD1
STAGE2_FF_WORD2
STAGE2_FF_WORD3
STAGE2_FF_WORD4
STAGE2_FF_WORD5
STAGE2_FF_WORD6
STAGE2_FF_WORD7
STAGE2_SF_WORD0
STAGE2_SF_WORD1
STAGE2_SF_WORD2
STAGE2_SF_WORD3
STAGE2_SF_WORD4
STAGE2_SF_WORD5
STAGE2_SF_WORD6
STAGE2_SF_WORD7
STAGE2_SF_AMBIENT
STAGE2_FF_AVG
STAGE2_PEAK_DETECT_WORD0
STAGE2_PEAK_DETECT_WORD1
STAGE2_MAX_WORD0
STAGE2_MAX_WORD1
STAGE2_MAX_WORD2
STAGE2_MAX_WORD3
STAGE2_MAX_AVG
STAGE2_HIGH_THRESHOLD
STAGE2_MAX_TEMP
STAGE2_MIN_WORD0
STAGE2_MIN_WORD1
STAGE2_MIN_WORD2
STAGE2_MIN_WORD3
STAGE2_MIN_AVG
STAGE2_LOW_THRESHOLD
STAGE2_MIN_TEMP
Unused
Rev. E | Page 60 of 70
Description
STAGE2 CDC 16-bit conversion data
(copy of CDC_RESULT_S2 register)
STAGE2 fast FIFO WORD0
STAGE2 fast FIFO WORD1
STAGE2 fast FIFO WORD2
STAGE2 fast FIFO WORD3
STAGE2 fast FIFO WORD4
STAGE2 fast FIFO WORD5
STAGE2 fast FIFO WORD6
STAGE2 fast FIFO WORD7
STAGE2 slow FIFO WORD0
STAGE2 slow FIFO WORD1
STAGE2 slow FIFO WORD2
STAGE2 slow FIFO WORD3
STAGE2 slow FIFO WORD4
STAGE2 slow FIFO WORD5
STAGE2 slow FIFO WORD6
STAGE2 slow FIFO WORD7
STAGE2 slow FIFO ambient value
STAGE2 fast FIFO average value
STAGE2 peak FIFO WORD0 value
STAGE2 peak FIFO WORD1 value
STAGE2 maximum value FIFO WORD0
STAGE2 maximum value FIFO WORD1
STAGE2 maximum value FIFO WORD2
STAGE2 maximum value FIFO WORD3
STAGE2 average maximum FIFO value
STAGE2 high threshold value
STAGE2 temporary maximum value
STAGE2 minimum value FIFO WORD0
STAGE2 minimum value FIFO WORD1
STAGE2 minimum value FIFO WORD2
STAGE2 minimum value FIFO WORD3
STAGE2 average minimum FIFO value
STAGE2 low threshold value
STAGE2 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 42. STAGE3 Results Registers
Address
0x14C
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE3_CONV_DATA
0x14D
0x14E
0x14F
0x150
0x151
0x152
0x153
0x154
0x155
0x156
0x157
0x158
0x159
0x15A
0x15B
0x15C
0x15D
0x15E
0x15F
0x160
0x161
0x162
0x163
0x164
0x165
0x166
0x167
0x168
0x169
0x16A
0x16B
0x16C
0x16D
0x16E
0x16F
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE3_FF_WORD0
STAGE3_FF_WORD1
STAGE3_FF_WORD2
STAGE3_FF_WORD3
STAGE3_FF_WORD4
STAGE3_FF_WORD5
STAGE3_FF_WORD6
STAGE3_FF_WORD7
STAGE3_SF_WORD0
STAGE3_SF_WORD1
STAGE3_SF_WORD2
STAGE3_SF_WORD3
STAGE3_SF_WORD4
STAGE3_SF_WORD5
STAGE3_SF_WORD6
STAGE3_SF_WORD7
STAGE3_SF_AMBIENT
STAGE3_FF_AVG
STAGE3_PEAK_DETECT_WORD0
STAGE3_PEAK_DETECT_WORD1
STAGE3_MAX_WORD0
STAGE3_MAX_WORD1
STAGE3_MAX_WORD2
STAGE3_MAX_WORD3
STAGE3_MAX_AVG
STAGE3_HIGH_THRESHOLD
STAGE3_MAX_TEMP
STAGE3_MIN_WORD0
STAGE3_MIN_WORD1
STAGE3_MIN_WORD2
STAGE3_MIN_WORD3
STAGE3_MIN_AVG
STAGE3_LOW_THRESHOLD
STAGE3_MIN_TEMP
Unused
Rev. E | Page 61 of 70
Description
STAGE3 CDC 16-bit conversion data
(copy of CDC_RESULT_S3 register)
STAGE3 fast FIFO WORD0
STAGE3 fast FIFO WORD1
STAGE3 fast FIFO WORD2
STAGE3 fast FIFO WORD3
STAGE3 fast FIFO WORD4
STAGE3 fast FIFO WORD5
STAGE3 fast FIFO WORD6
STAGE3 fast FIFO WORD7
STAGE3 slow FIFO WORD0
STAGE3 slow FIFO WORD1
STAGE3 slow FIFO WORD2
STAGE3 slow FIFO WORD3
STAGE3 slow FIFO WORD4
STAGE3 slow FIFO WORD5
STAGE3 slow FIFO WORD6
STAGE3 slow FIFO WORD7
STAGE3 slow FIFO ambient value
STAGE3 fast FIFO average value
STAGE3 peak FIFO WORD0 value
STAGE3 peak FIFO WORD1 value
STAGE3 maximum value FIFO WORD0
STAGE3 maximum value FIFO WORD1
STAGE3 maximum value FIFO WORD2
STAGE3 maximum value FIFO WORD3
STAGE3 average maximum FIFO value
STAGE3 high threshold value
STAGE3 temporary maximum value
STAGE3 minimum value FIFO WORD0
STAGE3 minimum value FIFO WORD1
STAGE3 minimum value FIFO WORD2
STAGE3 minimum value FIFO WORD3
STAGE3 average minimum FIFO value
STAGE3 low threshold value
STAGE3 temporary minimum value
Set to 0
AD7147
Data Sheet
Table 43. STAGE4 Results Registers
Address
0x170
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE4_CONV_DATA
0x171
0x172
0x173
0x174
0x175
0x176
0x177
0x178
0x179
0x17A
0x17B
0x17C
0x17D
0x17E
0x17F
0x180
0x181
0x182
0x183
0x184
0x185
0x186
0x187
0x188
0x189
0x18A
0x18B
0x18C
0x18D
0x18E
0x18F
0x190
0x191
0x192
0x193
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE4_FF_WORD0
STAGE4_FF_WORD1
STAGE4_FF_WORD2
STAGE4_FF_WORD3
STAGE4_FF_WORD4
STAGE4_FF_WORD5
STAGE4_FF_WORD6
STAGE4_FF_WORD7
STAGE4_SF_WORD0
STAGE4_SF_WORD1
STAGE4_SF_WORD2
STAGE4_SF_WORD3
STAGE4_SF_WORD4
STAGE4_SF_WORD5
STAGE4_SF_WORD6
STAGE4_SF_WORD7
STAGE4_SF_AMBIENT
STAGE4_FF_AVG
STAGE4_PEAK_DETECT_WORD0
STAGE4_PEAK_DETECT_WORD1
STAGE4_MAX_WORD0
STAGE4_MAX_WORD1
STAGE4_MAX_WORD2
STAGE4_MAX_WORD3
STAGE4_MAX_AVG
STAGE4_HIGH_THRESHOLD
STAGE4_MAX_TEMP
STAGE4_MIN_WORD0
STAGE4_MIN_WORD1
STAGE4_MIN_WORD2
STAGE4_MIN_WORD3
STAGE4_MIN_AVG
STAGE4_LOW_THRESHOLD
STAGE4_MIN_TEMP
Unused
Rev. E | Page 62 of 70
Description
STAGE4 CDC 16-bit conversion data
(copy of CDC_RESULT_S4 register)
STAGE4 fast FIFO WORD0
STAGE4 fast FIFO WORD1
STAGE4 fast FIFO WORD2
STAGE4 fast FIFO WORD3
STAGE4 fast FIFO WORD4
STAGE4 fast FIFO WORD5
STAGE4 fast FIFO WORD6
STAGE4 fast FIFO WORD7
STAGE4 slow FIFO WORD0
STAGE4 slow FIFO WORD1
STAGE4 slow FIFO WORD2
STAGE4 slow FIFO WORD3
STAGE4 slow FIFO WORD4
STAGE4 slow FIFO WORD5
STAGE4 slow FIFO WORD6
STAGE4 slow FIFO WORD7
STAGE4 slow FIFO ambient value
STAGE4 fast FIFO average value
STAGE4 peak FIFO WORD0 value
STAGE4 peak FIFO WORD1 value
STAGE4 maximum value FIFO WORD0
STAGE4 maximum value FIFO WORD1
STAGE4 maximum value FIFO WORD2
STAGE4 maximum value FIFO WORD3
STAGE4 average maximum FIFO value
STAGE4 high threshold value
STAGE4 temporary maximum value
STAGE4 minimum value FIFO WORD0
STAGE4 minimum value FIFO WORD1
STAGE4 minimum value FIFO WORD2
STAGE4 minimum value FIFO WORD3
STAGE4 average minimum FIFO value
STAGE4 low threshold value
STAGE4 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 44. STAGE5 Results Registers
Address
0x194
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE5_CONV_DATA
0x195
0x196
0x197
0x198
0x199
0x19A
0x19B
0x19C
0x19D
0x19E
0x19F
0x1A0
0x1A1
0x1A2
0x1A3
0x1A4
0x1A5
0x1A6
0x1A7
0x1A8
0x1A9
0x1AA
0x1AB
0x1AC
0x1AD
0x1AE
0x1AF
0x1B0
0x1B1
0x1B2
0x1B3
0x1B4
0x1B5
0x1B6
0x1B7
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE5_FF_WORD0
STAGE5_FF_WORD1
STAGE5_FF_WORD2
STAGE5_FF_WORD3
STAGE5_FF_WORD4
STAGE5_FF_WORD5
STAGE5_FF_WORD6
STAGE5_FF_WORD7
STAGE5_SF_WORD0
STAGE5_SF_WORD1
STAGE5_SF_WORD2
STAGE5_SF_WORD3
STAGE5_SF_WORD4
STAGE5_SF_WORD5
STAGE5_SF_WORD6
STAGE5_SF_WORD7
STAGE5_SF_AMBIENT
STAGE5_FF_AVG
STAGE5_PEAK_DETECT_WORD0
STAGE5_PEAK_DETECT_WORD1
STAGE5_MAX_WORD0
STAGE5_MAX_WORD1
STAGE5_MAX_WORD2
STAGE5_MAX_WORD3
STAGE5_MAX_AVG
STAGE5_HIGH_THRESHOLD
STAGE5_MAX_TEMP
STAGE5_MIN_WORD0
STAGE5_MIN_WORD1
STAGE5_MIN_WORD2
STAGE5_MIN_WORD3
STAGE5_MIN_AVG
STAGE5_LOW_THRESHOLD
STAGE5_MIN_TEMP
Unused
Rev. E | Page 63 of 70
Description
STAGE5 CDC 16-bit conversion data
(copy of CDC_RESULT_S5 register)
STAGE5 fast FIFO WORD0
STAGE5 fast FIFO WORD1
STAGE5 fast FIFO WORD2
STAGE5 fast FIFO WORD3
STAGE5 fast FIFO WORD4
STAGE5 fast FIFO WORD5
STAGE5 fast FIFO WORD6
STAGE5 fast FIFO WORD7
STAGE5 slow FIFO WORD0
STAGE5 slow FIFO WORD1
STAGE5 slow FIFO WORD2
STAGE5 slow FIFO WORD3
STAGE5 slow FIFO WORD4
STAGE5 slow FIFO WORD5
STAGE5 slow FIFO WORD6
STAGE5 slow FIFO WORD7
STAGE5 slow FIFO ambient value
STAGE5 fast FIFO average value
STAGE5 peak FIFO WORD0 value
STAGE5 peak FIFO WORD1 value
STAGE5 maximum value FIFO WORD0
STAGE5 maximum value FIFO WORD1
STAGE5 maximum value FIFO WORD2
STAGE5 maximum value FIFO WORD3
STAGE5 average maximum FIFO value
STAGE5 high threshold value
STAGE5 temporary maximum value
STAGE5 minimum value FIFO WORD0
STAGE5 minimum value FIFO WORD1
STAGE5 minimum value FIFO WORD2
STAGE5 minimum value FIFO WORD3
STAGE5 average minimum FIFO value
STAGE5 low threshold value
STAGE5 temporary minimum value
Set to 0
AD7147
Data Sheet
Table 45. STAGE6 Results Registers
Address
0x1B8
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE6_CONV_DATA
0x1B9
0x1BA
0x1BB
0x1BC
0x1BD
0x1BE
0x1BF
0x1C0
0x1C1
0x1C2
0x1C3
0x1C4
0x1C5
0x1C6
0x1C7
0x1C8
0x1C9
0x1CA
0x1CB
0x1CC
0x1CD
0x1CE
0x1CF
0x1D0
0x1D1
0x1D2
0x1D3
0x1D4
0x1D5
0x1D6
0x1D7
0x1D8
0x1D9
0x1DA
0x1DB
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE6_FF_WORD0
STAGE6_FF_WORD1
STAGE6_FF_WORD2
STAGE6_FF_WORD3
STAGE6_FF_WORD4
STAGE6_FF_WORD5
STAGE6_FF_WORD6
STAGE6_FF_WORD7
STAGE6_SF_WORD0
STAGE6_SF_WORD1
STAGE6_SF_WORD2
STAGE6_SF_WORD3
STAGE6_SF_WORD4
STAGE6_SF_WORD5
STAGE6_SF_WORD6
STAGE6_SF_WORD7
STAGE6_SF_AMBIENT
STAGE6_FF_AVG
STAGE6_PEAK_DETECT_WORD0
STAGE6_PEAK_DETECT_WORD1
STAGE6_MAX_WORD0
STAGE6_MAX_WORD1
STAGE6_MAX_WORD2
STAGE6_MAX_WORD3
STAGE6_MAX_AVG
STAGE6_HIGH_THRESHOLD
STAGE6_MAX_TEMP
STAGE6_MIN_WORD0
STAGE6_MIN_WORD1
STAGE6_MIN_WORD2
STAGE6_MIN_WORD3
STAGE6_MIN_AVG
STAGE6_LOW_THRESHOLD
STAGE6_MIN_TEMP
Unused
Rev. E | Page 64 of 70
Description
STAGE6 CDC 16-bit conversion data
(copy of CDC_RESULT_S6 register)
STAGE6 fast FIFO WORD0
STAGE6 fast FIFO WORD1
STAGE6 fast FIFO WORD2
STAGE6 fast FIFO WORD3
STAGE6 fast FIFO WORD4
STAGE6 fast FIFO WORD5
STAGE6 fast FIFO WORD6
STAGE6 fast FIFO WORD7
STAGE6 slow FIFO WORD0
STAGE6 slow FIFO WORD1
STAGE6 slow FIFO WORD2
STAGE6 slow FIFO WORD3
STAGE6 slow FIFO WORD4
STAGE6 slow FIFO WORD5
STAGE6 slow FIFO WORD6
STAGE6 slow FIFO WORD7
STAGE6 slow FIFO ambient value
STAGE6 fast FIFO average value
STAGE6 peak FIFO WORD0 value
STAGE6 peak FIFO WORD1 value
STAGE6 maximum value FIFO WORD0
STAGE6 maximum value FIFO WORD1
STAGE6 maximum value FIFO WORD2
STAGE6 maximum value FIFO WORD3
STAGE6 average maximum FIFO value
STAGE6 high threshold value
STAGE6 temporary maximum value
STAGE6 minimum value FIFO WORD0
STAGE6 minimum value FIFO WORD1
STAGE6 minimum value FIFO WORD2
STAGE6 minimum value FIFO WORD3
STAGE6 average minimum FIFO value
STAGE6 low threshold value
STAGE6 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 46. STAGE7 Results Registers
Address
0x1DC
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE7_CONV_DATA
0x1DD
0x1DE
0x1DF
0x1E0
0x1E1
0x1E2
0x1E3
0x1E4
0x1E5
0x1E6
0x1E7
0x1E8
0x1E9
0x1EA
0x1EB
0x1EC
0x1ED
0x1EE
0x1EF
0x1F0
0x1F1
0x1F2
0x1F3
0x1F4
0x1F5
0x1F6
0x1F7
0x1F8
0x1F9
0x1FA
0x1FB
0x1FC
0x1FD
0x1FE
0x1FF
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE7_FF_WORD0
STAGE7_FF_WORD1
STAGE7_FF_WORD2
STAGE7_FF_WORD3
STAGE7_FF_WORD4
STAGE7_FF_WORD5
STAGE7_FF_WORD6
STAGE7_FF_WORD7
STAGE7_SF_WORD0
STAGE7_SF_WORD1
STAGE7_SF_WORD2
STAGE7_SF_WORD3
STAGE7_SF_WORD4
STAGE7_SF_WORD5
STAGE7_SF_WORD6
STAGE7_SF_WORD7
STAGE7_SF_AMBIENT
STAGE7_FF_AVG
STAGE7_PEAK_DETECT_WORD0
STAGE7_PEAK_DETECT_WORD1
STAGE7_MAX_WORD0
STAGE7_MAX_WORD1
STAGE7_MAX_WORD2
STAGE7_MAX_WORD3
STAGE7_MAX_AVG
STAGE7_HIGH_THRESHOLD
STAGE7_MAX_TEMP
STAGE7_MIN_WORD0
STAGE7_MIN_WORD1
STAGE7_MIN_WORD2
STAGE7_MIN_WORD3
STAGE7_MIN_AVG
STAGE7_LOW_THRESHOLD
STAGE7_MIN_TEMP
Unused
Rev. E | Page 65 of 70
Description
STAGE7 CDC 16-bit conversion data
(copy of CDC_RESULT_S7 register)
STAGE7 fast FIFO WORD0
STAGE7 fast FIFO WORD1
STAGE7 fast FIFO WORD2
STAGE7 fast FIFO WORD3
STAGE7 fast FIFO WORD4
STAGE7 fast FIFO WORD5
STAGE7 fast FIFO WORD6
STAGE7 fast FIFO WORD7
STAGE7 slow FIFO WORD0
STAGE7 slow FIFO WORD1
STAGE7 slow FIFO WORD2
STAGE7 slow FIFO WORD3
STAGE7 slow FIFO WORD4
STAGE7 slow FIFO WORD5
STAGE7 slow FIFO WORD6
STAGE7 slow FIFO WORD7
STAGE7 slow FIFO ambient value
STAGE7 fast FIFO average value
STAGE7 peak FIFO WORD0 value
STAGE7 peak FIFO WORD1 value
STAGE7 maximum value FIFO WORD0
STAGE7 maximum value FIFO WORD1
STAGE7 maximum value FIFO WORD2
STAGE7 maximum value FIFO WORD3
STAGE7 average maximum FIFO value
STAGE7 high threshold value
STAGE7 temporary maximum value
STAGE7 minimum value FIFO WORD0
STAGE7 minimum value FIFO WORD1
STAGE7 minimum value FIFO WORD2
STAGE7 minimum value FIFO WORD3
STAGE7 average minimum FIFO value
STAGE7 low threshold value
STAGE7 temporary minimum value
Set to 0
AD7147
Data Sheet
Table 47. STAGE8 Results Registers
Address
0x200
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE8_CONV_DATA
0x201
0x202
0x203
0x204
0x205
0x206
0x207
0x208
0x209
0x20A
0x20B
0x20C
0x20D
0x20E
0x20F
0x210
0x211
0x212
0x213
0x214
0x215
0x216
0x217
0x218
0x219
0x21A
0x21B
0x21C
0x21D
0x21E
0x21F
0x220
0x221
0x222
0x223
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE8_FF_WORD0
STAGE8_FF_WORD1
STAGE8_FF_WORD2
STAGE8_FF_WORD3
STAGE8_FF_WORD4
STAGE8_FF_WORD5
STAGE8_FF_WORD6
STAGE8_FF_WORD7
STAGE8_SF_WORD0
STAGE8_SF_WORD1
STAGE8_SF_WORD2
STAGE8_SF_WORD3
STAGE8_SF_WORD4
STAGE8_SF_WORD5
STAGE8_SF_WORD6
STAGE8_SF_WORD7
STAGE8_SF_AMBIENT
STAGE8_FF_AVG
STAGE8_PEAK_DETECT_WORD0
STAGE8_PEAK_DETECT_WORD1
STAGE8_MAX_WORD0
STAGE8_MAX_WORD1
STAGE8_MAX_WORD2
STAGE8_MAX_WORD3
STAGE8_MAX_AVG
STAGE8_HIGH_THRESHOLD
STAGE8_MAX_TEMP
STAGE8_MIN_WORD0
STAGE8_MIN_WORD1
STAGE8_MIN_WORD2
STAGE8_MIN_WORD3
STAGE8_MIN_AVG
STAGE8_LOW_THRESHOLD
STAGE8_MIN_TEMP
Unused
Rev. E | Page 66 of 70
Description
STAGE8 CDC 16-bit conversion data
(copy of CDC_RESULT_S8 register)
STAGE8 fast FIFO WORD0
STAGE8 fast FIFO WORD1
STAGE8 fast FIFO WORD2
STAGE8 fast FIFO WORD3
STAGE8 fast FIFO WORD4
STAGE8 fast FIFO WORD5
STAGE8 fast FIFO WORD6
STAGE8 fast FIFO WORD7
STAGE8 slow FIFO WORD0
STAGE8 slow FIFO WORD1
STAGE8 slow FIFO WORD2
STAGE8 slow FIFO WORD3
STAGE8 slow FIFO WORD4
STAGE8 slow FIFO WORD5
STAGE8 slow FIFO WORD6
STAGE8 slow FIFO WORD7
STAGE8 slow FIFO ambient value
STAGE8 fast FIFO average value
STAGE8 peak FIFO WORD0 value
STAGE8 peak FIFO WORD1 value
STAGE8 maximum value FIFO WORD0
STAGE8 maximum value FIFO WORD1
STAGE8 maximum value FIFO WORD2
STAGE8 maximum value FIFO WORD3
STAGE8 average maximum FIFO value
STAGE8 high threshold value
STAGE8 temporary maximum value
STAGE8 minimum value FIFO WORD0
STAGE8 minimum value FIFO WORD1
STAGE8 minimum value FIFO WORD2
STAGE8 minimum value FIFO WORD3
STAGE8 average minimum FIFO value
STAGE8 low threshold value
STAGE7 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 48. STAGE9 Results Registers
Address
0x224
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE9_CONV_DATA
0x225
0x226
0x227
0x228
0x229
0x22A
0x22B
0x22C
0x22D
0x22E
0x22F
0x230
0x231
0x232
0x233
0x234
0x235
0x236
0x237
0x238
0x239
0x23A
0x23B
0x23C
0x23D
0x23E
0x23F
0x240
0x241
0x242
0x243
0x244
0x245
0x246
0x247
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE9_FF_WORD0
STAGE9_FF_WORD1
STAGE9_FF_WORD2
STAGE9_FF_WORD3
STAGE9_FF_WORD4
STAGE9_FF_WORD5
STAGE9_FF_WORD6
STAGE9_FF_WORD7
STAGE9_SF_WORD0
STAGE9_SF_WORD1
STAGE9_SF_WORD2
STAGE9_SF_WORD3
STAGE9_SF_WORD4
STAGE9_SF_WORD5
STAGE9_SF_WORD6
STAGE9_SF_WORD7
STAGE9_SF_AMBIENT
STAGE9_FF_AVG
STAGE9_PEAK_DETECT_WORD0
STAGE9_PEAK_DETECT_WORD1
STAGE9_MAX_WORD0
STAGE9_MAX_WORD1
STAGE9_MAX_WORD2
STAGE9_MAX_WORD3
STAGE9_MAX_AVG
STAGE9_HIGH_THRESHOLD
STAGE9_MAX_TEMP
STAGE9_MIN_WORD0
STAGE9_MIN_WORD1
STAGE9_MIN_WORD2
STAGE9_MIN_WORD3
STAGE9_MIN_AVG
STAGE9_LOW_THRESHOLD
STAGE9_MIN_TEMP
Unused
Rev. E | Page 67 of 70
Description
STAGE9 CDC 16-bit conversion data
(copy of CDC_RESULT_S9 register)
STAGE9 fast FIFO WORD0
STAGE9 fast FIFO WORD1
STAGE9 fast FIFO WORD2
STAGE9 fast FIFO WORD3
STAGE9 fast FIFO WORD4
STAGE9 fast FIFO WORD5
STAGE9 fast FIFO WORD6
STAGE9 fast FIFO WORD7
STAGE9 slow FIFO WORD0
STAGE9 slow FIFO WORD1
STAGE9 slow FIFO WORD2
STAGE9 slow FIFO WORD3
STAGE9 slow FIFO WORD4
STAGE9 slow FIFO WORD5
STAGE9 slow FIFO WORD6
STAGE9 slow FIFO WORD7
STAGE9 slow FIFO ambient value
STAGE9 fast FIFO average value
STAGE9 peak FIFO WORD0 value
STAGE9 peak FIFO WORD1 value
STAGE9 maximum value FIFO WORD0
STAGE9 maximum value FIFO WORD1
STAGE9 maximum value FIFO WORD2
STAGE9 maximum value FIFO WORD3
STAGE9 average maximum FIFO value
STAGE9 high threshold value
STAGE9 temporary maximum value
STAGE9 minimum value FIFO WORD0
STAGE9 minimum value FIFO WORD1
STAGE9 minimum value FIFO WORD2
STAGE9 minimum value FIFO WORD3
STAGE9 average minimum FIFO value
STAGE9 low threshold value
STAGE9 temporary minimum value
Set to 0
AD7147
Data Sheet
Table 49. STAGE10 Results Registers
Address
0x248
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE10_CONV_DATA
0x249
0x24A
0x24B
0x24C
0x24D
0x24E
0x24F
0x250
0x251
0x252
0x253
0x254
0x255
0x256
0x257
0x258
0x259
0x25A
0x25B
0x25C
0x25D
0x25E
0x25F
0x260
0x261
0x262
0x263
0x264
0x265
0x266
0x267
0x268
0x269
0x26A
0x26B
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE10_FF_WORD0
STAGE10_FF_WORD1
STAGE10_FF_WORD2
STAGE10_FF_WORD3
STAGE10_FF_WORD4
STAGE10_FF_WORD5
STAGE10_FF_WORD6
STAGE10_FF_WORD7
STAGE10_SF_WORD0
STAGE10_SF_WORD1
STAGE10_SF_WORD2
STAGE10_SF_WORD3
STAGE10_SF_WORD4
STAGE10_SF_WORD5
STAGE10_SF_WORD6
STAGE10_SF_WORD7
STAGE10_SF_AMBIENT
STAGE10_FF_AVG
STAGE10_PEAK_DETECT_WORD0
STAGE10_PEAK_DETECT_WORD1
STAGE10_MAX_WORD0
STAGE10_MAX_WORD1
STAGE10_MAX_WORD2
STAGE10_MAX_WORD3
STAGE10_MAX_AVG
STAGE10_HIGH_THRESHOLD
STAGE10_MAX_TEMP
STAGE10_MIN_WORD0
STAGE10_MIN_WORD1
STAGE10_MIN_WORD2
STAGE10_MIN_WORD3
STAGE10_MIN_AVG
STAGE10_LOW_THRESHOLD
STAGE10_MIN_TEMP
Unused
Rev. E | Page 68 of 70
Description
STAGE10 CDC 16-bit conversion data
(copy of CDC_RESULT_S10 register)
STAGE10 fast FIFO WORD0
STAGE10 fast FIFO WORD1
STAGE10 fast FIFO WORD2
STAGE10 fast FIFO WORD3
STAGE10 fast FIFO WORD4
STAGE10 fast FIFO WORD5
STAGE10 fast FIFO WORD6
STAGE10 fast FIFO WORD7
STAGE10 slow FIFO WORD0
STAGE10 slow FIFO WORD1
STAGE10 slow FIFO WORD2
STAGE10 slow FIFO WORD3
STAGE10 slow FIFO WORD4
STAGE10 slow FIFO WORD5
STAGE10 slow FIFO WORD6
STAGE10 slow FIFO WORD7
STAGE10 slow FIFO ambient value
STAGE10 fast FIFO average value
STAGE10 peak FIFO WORD0 value
STAGE10 peak FIFO WORD1 value
STAGE10 maximum value FIFO WORD0
STAGE10 maximum value FIFO WORD1
STAGE10 maximum value FIFO WORD2
STAGE10 maximum value FIFO WORD3
STAGE10 average maximum FIFO value
STAGE10 high threshold value
STAGE10 temporary maximum value
STAGE10 minimum value FIFO WORD0
STAGE10 minimum value FIFO WORD1
STAGE10 minimum value FIFO WORD2
STAGE10 minimum value FIFO WORD3
STAGE10 average minimum FIFO value
STAGE10 low threshold value
STAGE10 temporary minimum value
Set to 0
Data Sheet
AD7147
Table 50. STAGE11 Results Registers
Address
0x26C
Data Bit
[15:0]
Default
Value
X
Type
R/W
Name
STAGE11_CONV_DATA
0x26D
0x26E
0x26F
0x270
0x271
0x272
0x273
0x274
0x275
0x276
0x277
0x278
0x279
0x27A
0x27B
0x27C
0x27D
0x27E
0x27F
0x280
0x281
0x282
0x283
0x284
0x285
0x286
0x287
0x288
0x289
0x28A
0x28B
0x28C
0x28D
0x28E
0x28F
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
[15:0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
STAGE11_FF_WORD0
STAGE11_FF_WORD1
STAGE11_FF_WORD2
STAGE11_FF_WORD3
STAGE11_FF_WORD4
STAGE11_FF_WORD5
STAGE11_FF_WORD6
STAGE11_FF_WORD7
STAGE11_SF_WORD0
STAGE11_SF_WORD1
STAGE11_SF_WORD2
STAGE11_SF_WORD3
STAGE11_SF_WORD4
STAGE11_SF_WORD5
STAGE11_SF_WORD6
STAGE11_SF_WORD7
STAGE11_SF_AMBIENT
STAGE11_FF_AVG
STAGE11_PEAK_DETECT_WORD0
STAGE11_PEAK_DETECT_WORD1
STAGE11_MAX_WORD0
STAGE11_MAX_WORD1
STAGE11_MAX_WORD2
STAGE11_MAX_WORD3
STAGE11_MAX_AVG
STAGE11_HIGH_THRESHOLD
STAGE11_MAX_TEMP
STAGE11_MIN_WORD0
STAGE11_MIN_WORD1
STAGE11_MIN_WORD2
STAGE11_MIN_WORD3
STAGE11_MIN_AVG
STAGE11_LOW_THRESHOLD
STAGE11_MIN_TEMP
Unused
Rev. E | Page 69 of 70
Description
STAGE11 CDC 16-bit conversion data
(copy of CDC_RESULT_S11 register)
STAGE11 fast FIFO WORD0
STAGE11 fast FIFO WORD1
STAGE11 fast FIFO WORD2
STAGE11 fast FIFO WORD3
STAGE11 fast FIFO WORD4
STAGE11 fast FIFO WORD5
STAGE11 fast FIFO WORD6
STAGE11 fast FIFO WORD7
STAGE11 slow FIFO WORD0
STAGE11 slow FIFO WORD1
STAGE11 slow FIFO WORD2
STAGE11 slow FIFO WORD3
STAGE11 slow FIFO WORD4
STAGE11 slow FIFO WORD5
STAGE11 slow FIFO WORD6
STAGE11 slow FIFO WORD7
STAGE11 slow FIFO ambient value
STAGE11 fast FIFO average value
STAGE11 peak FIFO WORD0 value
STAGE11 peak FIFO WORD1 value
STAGE11 maximum value FIFO WORD0
STAGE11 maximum value FIFO WORD1
STAGE11 maximum value FIFO WORD2
STAGE11 maximum value FIFO WORD3
STAGE11 average maximum FIFO value
STAGE11 high threshold value
STAGE11 temporary maximum value
STAGE11 minimum value FIFO WORD0
STAGE11 minimum value FIFO WORD1
STAGE11 minimum value FIFO WORD2
STAGE11 minimum value FIFO WORD3
STAGE11 average minimum FIFO value
STAGE11 low threshold value
STAGE11 temporary minimum value
Set to 0
AD7147
Data Sheet
OUTLINE DIMENSIONS
0.30
0.25
0.18
0.50
BSC
PIN 1
INDICATOR
24
19
18
1
EXPOSED
PAD
2.65
2.50 SQ
2.45
13
TOP VIEW
0.80
0.75
0.70
0.50
0.40
0.30
6
12
BOTTOM VIEW
0.05 MAX
0.02 NOM
COPLANARITY
0.08
SEATING
PLANE
7
0.25 MIN
FOR PROPER CONNECTION OF
THE EXPOSED PAD, REFER TO
THE PIN CONFIGURATION AND
FUNCTION DESCRIPTIONS
SECTION OF THIS DATA SHEET.
0.20 REF
COMPLIANT TO JEDEC STANDARDS MO-220-WGGD.
03-11-2013-A
PIN 1
INDICATOR
4.10
4.00 SQ
3.90
Figure 63. 24-Lead Frame Chip Scale Package [LFCSP_WQ]
4 mm × 4 mm Very Very Thin Quad
(CP-24-7)
Dimensions shown in millimeters
ORDERING GUIDE
Model1, 2
AD7147ACPZ-REEL
AD7147ACPZ-500RL7
AD7147PACPZ-RL
AD7147PACPZ-500R7
AD7147ACPZ-1REEL
AD7147ACPZ-1500RL7
AD7147PACPZ-1RL
AD7147PACPZ-1500R7
AD7147WPACPZ-RL
AD7147WPACPZ-500R7
AD7147WPACPZ-1RL
AD7147WPACPZ-1500R
EVAL-AD7147EBZ
EVAL-AD7147-1EBZ
1
2
Temperature
Range
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
Description
Wake up on touch
Wake up on touch
Wake up on proximity
Wake up on proximity
Wake up on touch
Wake up on touch
Wake up on proximity
Wake up on proximity
Wake up on proximity
Wake up on proximity
Wake up on proximity
Wake up on proximity
Serial Interface
Description
SPI Interface
SPI Interface
SPI Interface
SPI Interface
I2C Interface
I2C Interface
I2C Interface
I2C Interface
SPI Interface
SPI Interface
I2C Interface
I2C Interface
SPI Interface
I2C Interface
Package Description
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
24-Lead LFCSP_WQ
Evaluation Board
Evaluation Board
Package
Option
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
CP-24-7
Z = RoHS Compliant Part.
W = Qualified for Automotive Applications.
AUTOMOTIVE PRODUCTS
The AD7147W models are available with controlled manufacturing to support the quality and reliability requirements of automotive
applications. Note that these automotive models may have specifications that differ from the commercial models; therefore, designers
should review the Specifications section of this data sheet carefully. Only the automotive grade products shown are available for use in
automotive applications. Contact your local Analog Devices account representative for specific product ordering information and to
obtain the specific Automotive Reliability reports for these models.
©2007–2015 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D06663-0-1/15(E)
Rev. E | Page 70 of 70
Similar pages