Diodes FR601 6.0a fast recovery rectifier Datasheet

FR601 - FR607
6.0A FAST RECOVERY RECTIFIER
Features
·
·
·
·
·
Low Reverse Recovery Time
Low Reverse Current
Low Forward Voltage Drop
High Current Capability
Plastic Material: UL Flammability
Classification Rating 94V-0
A
A
B
C
D
Mechanical Data
·
·
·
·
·
R-6
Case: R-6, Molded Plastic
Terminals: Axial Leads, Solderable per
MIL-STD-202 Method 208
Polarity: Color Band Denotes Cathode
Weight: 1.7 grams (approx.)
Mounting Position: Any
Dim
Min
A
25.4
Max
¾
B
8.6
9.1
C
1.2
1.3
D
8.6
9.1
All Dimensions in mm
Maximum Ratings and Electrical Characteristics
@ TA = 25°C unless otherwise specified.
Symbol
FR
601
FR
602
FR
603
FR
604
FR
605
FR
606
FR
607
Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking voltage
VDC
50
100
200
400
600
800
1000
V
Characteristic
Maximum Average Forward Rectified Current
9.5mm Lead Length
@ TA=75°C
Peak Forward Surge Current
8.3ms single half sine-wave superimposed on rated load
(JEDEC method)
Maximum Instantaneous Forward Voltage
@ 6.0A DC
Maximum DC Reverse Current at Rated Blocking Voltage
@ TA = 25°C
Maximum Full Load Reverse Current
Full Cycle Average 9.5mm lead length
@ TL = 55°C
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
Notes:
I(AV)
6.0
A
IFSM
300
A
VF
1.3
V
IR
10
mA
IR
150
mA
Trr
150
250
500
ns
CJ
200
pF
TJ, TSTG
-65 to +175
°C
1. Reverse Recovery Test Conditions: IF =0.5A, IR =1.0A, IRR =0.25A
2. Measured at 1.0MHz and applied reverse voltage of 4.0V.
DS26004 Rev. C1-3
1 of 2
FR601-FR607
6
4
2
0
0
25
50
75
100
125
150
175
IFsm, PEAK FORWARD SURGE CURRENT (AMPERES)
I(AV), AVERAGE FORWARD CURRENT
8
600
8.3ms Single Half Sine-Wave
JEDEC Method
500
400
300
200
100
0
1
1000
100
10
1
TJ = 25°C
Pulse Width
= 300µs
1% Duty Cycle
0.1
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
VF, INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
Fig. 3, Typical Instantaneous Forward Characteristics
DS26004 Rev. C1-3
100
NUMBER OF CYCLES AT 60 Hz
Fig. 2, Max Non-Repetitive Peak Surge Current
IFSM, PEAK FORWARD SURGE CURRENT (AMPERES)
IF, INSTANTANEOUS FORWARD CURRENT (AMPERES)
TA, AMBIENT TEMPERATURE (°C)
Fig. 1, Typical Forward Current Derating Curve
10
2 of 2
200
100
10
1
10
100
NUMBER OF CYCLES AT 60Hz
Fig. 4, Maximum Non-Repetitive Surge Current
FR601-FR607