MPD MB4048S03RU Mb4000ru sery Datasheet

MB4000RU Series
Compact, 1 x 2 Inch
40W, 4:1 Input Range
DC/DC Con
verters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
• 40W Output Power
Input Voltage Range
• 4:1 Input Voltage Range
Input Start Voltage
• 1,500 VDC Isolation
• Single & Dual Outputs
Under Voltage Shutdown
• Efficiency to 91%
Input Filter
Start-Up Time
• Compact 1 x 2 Inch Case
Output
• Wide Temp Operation
• Industry Standard Pin-Out
• Low Cost
Parameter
Output Voltage Accuracy
Output Voltage Balance
Output Trim Range
Line Regulation
Load Regulation, See Note 2
Cross Regulation
Ripple & Noise (20 MHz), See note 4
Transient Recovery Time, See Note 5
Transient Response Deviation
Temperature Coefficient
Over Temperature Protection
Output Power Protection
Output Short Circuit, See Note 6
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
LC Filter
See Note 1
Typ.
24.0
48.0
Conditions
Typ.
Min.
Max.
36.0
75.0
9.0
18.0
Units
VDC
VDC
8.3
16.5
VDC
30
mS
Dual Outputs, Balanced Loads
Max.
±1.0
±2.0
±10
VIN = Min to Max
Single Output
Dual Output
See Note 3
3.3 & 5 VOUT Models
12, 15 & 24 VOUT Models
Dual Output Models
±0.5
±0.5
±1.0
±5.0
100
150
150
250
25% Load Step Change
±3.0
±0.02
Shutdown Temperature
110
150
Continuous (Autorecovery)
±5.0
Conditions
Max.
Units
%
%
%
%
%
%
mV P - P
µSec
%
%/°C
°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
60 Seconds
500 VDC
100 kHz/1.0V
See Note 7
Min.
1,500
1,000
Typ.
1,500
320
Units
VDC
M
pF
kHz
Environmental
Parameter
Operating Temperature Range,
Ambient Without Heatsink
Operating Temperature Range,
Ambient With Heatsink
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Operating Temperature Range
Storage Temperature Range
Humidity
Physical
Case Size, See Note On Page 4
Case Material
Weight
Conditions
MB40xxS-03RU
MB40xxS-05RU, MB4048S-12RU, -15RU
MB4024S-12RU, MB4024S-15RU
MB40xxS-24RU
MB40xxD-xxRU
MB40xxS-03RU
MB40xxS-05RU, MB4048S-12RU, -15RU
MB4024S-12RU, MB4024S-15RU
MB40xxS-24RU
MB40xxD-xxRU
Case
Min.
Typ
-40
+25
-40
+25
-50
RH, Non-condensing
Max.
+66
+51
+45
+57
+40
+73
+61
+57
+66
+52
+105
+125
95
Units
°C
°C
°C
°C
%
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
1.06 Oz (30g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
328
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
MB4024S-03RU
MB4024S-05RU
MB4024S-12RU
MB4024S-15RU
MB4024S-24RU
MB4024D-12RU
MB4024D-15RU
MB4048S-03RU
MB4048S-05RU
MB4048S-12RU
MB4048S-15RU
MB4048S-24RU
MB4048D-12RU
MB4048D-15RU
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
24
9.0 - 36.0
1,240
90
24
9.0 - 36.0
1,850
90
24
9.0 - 36.0
1,870
95
24
9.0 - 36.0
1,870
105
24
9.0 - 36.0
1,835
115
24
9.0 - 36.0
1,890
65
24
9.0 - 36.0
1,890
65
48
18.0 - 75.0
620
55
48
18.0 - 75.0
930
55
48
18.0 - 75.0
930
60
48
18.0 - 75.0
930
65
48
18.0 - 75.0
918
75
48
18.0 - 75.0
950
45
48
18.0 - 75.0
950
45
Voltage
Output
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±12.0
±15.0
8,000
8,000
3,330
2,670
1,670
±1,670
±1,330
8,000
8,000
3,330
2,670
1,670
±1,670
±1,330
For heatsink option, add suffix “H” to model number (i.e. MB4024S-15RU-H)
0
0
0
0
0
±145
±110
0
0
0
0
0
±145
±110
Efficiency
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection (µF, Max)
Slow-Blow
(VDC Typ)
89
90
89
89
91
88
88
89
90
90
90
91
88
88
3.9
6.2
15.0
18.0
30.0
±15.0
±18.0
3.9
6.2
15.0
18.0
30.0
±15.0
±18.0
(A)
21,000
13,600
2,400
1,500
600
±1,200
±750
21,000
13,600
2,400
1,500
600
±1,200
±750
8.0
8.0
8.0
8.0
8.0
8.0
8.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
Remote On/Off
Notes:
1. Start up time is measured at nominal input and with a constant resistive load.
Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If
2. Load regulation is specified for a load change of minimum load to full load.
grounded, the unit will shut off. The specifications for the ON/OFF function are:
3. Cross regulation is measured with the output being tested at 100% load. The second output is varied from 25% to 100% load.
Parameter
Min
Typ
Max
Units
4. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in
3.5
12.0
VDC
parallel from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output units. Supply On
5. Transient recovery is measured to within a 1% error band for a load step change of 25%.
Supply Off
0.0
1.2
VDC
6. Short circuit protection is provided by a “hiccup mode” circuit.
Standby Input Current
2.5
mA
7. The switching frequency for 24 VDC output models is 285 kHz.
Control Common
Referenced to Negative Input (pin 2)
8. Operation at no-load will not damage these units. However, they may not meet all specifications if operated below the Control Input Current (ON)
mA
0.5
specified minimum load.
-0.5
mA
9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table Control Input Current (OFF)
above for the correct rating.
External Trim
On single output units, an external resister may be added to
adjust the converter output.
To adjust the output UP, connect a 5%, 3W resistor between
the minus output pin (5) and the Vout trim pin (6). To adjust
the output DOWN, connect a 5%, 3W resistor between the plus
output pin (4) and the Vout trim pin (6).
The trim table at right gives suggested resistor values for
this adjustment.
MB40xxS-03RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
72.61
32.55
19.20
12.52
8.51
5.84
3.94
2.51
1.39
0.50
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
60.84
27.40
16.25
10.68
7.34
5.11
3.51
2.32
1.39
0.65
Volts
k⍀
MB40xxS-05RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
138.88
62.41
36.92
24.18
16.53
11.44
7.79
5.06
2.94
1.24
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
106.87
47.76
28.06
18.21
12.30
8.36
5.55
3.44
1.79
0.48
Volts
k⍀
MB40xxS-12RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
413.55
184.55
108.22
70.05
47.15
31.88
20.98
12.80
6.44
1.35
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
351.00
157.50
93.00
60.75
41.40
28.50
19.29
12.37
7.00
2.70
Volts
k⍀
MB40xxS-15RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
530.73
238.61
141.24
92.56
63.35
43.87
29.96
19.53
11.41
4.92
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
422.77
189.89
112.26
73.44
50.15
34.63
23.54
15.22
8.75
3.58
Volts
k⍀
MB40xxS-24RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
333.39
148.80
87.26
56.50
38.04
25.73
16.94
10.35
5.22
1.12
Volts
k⍀
Trim Up
Vout
RUP
Volts
k⍀
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
243.70
108.50
63.43
40.90
27.38
18.37
11.93
7.10
3.34
0.34
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Derating Curves
MB40xxS-03RU Without Heatsink
MB40xxS-03RU With Heatsink
MB40xxS-05RU, MB4048S-12RU MB4048S-15RU Without Heatsink
MB40xxS-05RU, MB4048S-12RU MB4048S-15RU With Heatsink
MB4024S-12RU, MB4024S-15RU Without Heatsink
MB4024S-12RU, MB4024S-15RU With Heatsink
MB40xxD-12RU, MB40xxD-15RU Without Heatsink
MB40xxD-12RU, MB40xxD-15RU With Heatsink
MB40xxS-24RU Without Heatsink
MB40xxS-24RU With Heatsink
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
All units should meet EN 55022 (CE/RE) class A/B
with the simple external circuit shown; using the
component values given in the table.
To meet the requirements of EN 61000-4-4 and
EN 61000-4-5, the value of C1 should be changed
to 330 µF/200V. Contact the factory for more
information.
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Notes
Surge, See Notes
CS
Standard
Model
C1
C2
MB4024x-xxRU 4.7 µF/50V 1812 MLCC
--EN55022 Class A
MB4048x-xxRU 2.2 µF/100V 1812 MLCC
--MB40xxx-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1812 MLCC
EN55022 Class B
MB40xxx-24RU 4.7 µF/100V 1210/X7S 3.3 µF/100V 1812 MLCC
L1
----700 µH
700 µH
C3
C4
1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC
1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC
680 pF/2kV 1808 X7R
680 pF/2kV 1808 X7R
1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R
Standard
EN 55022
Class A
EN 55022
Class A
EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact
EN 61000-4-3
Criteria A; 10V/m
EN 61000-4-4
Criteria A; ±2 kV
EN 61000-4-5
Criteria B; ±1 kV
EN 61000-4-6
Criteria A; 10 V/m
Mechanical Dimensions
Pin Connections
Mechanical Dimensions: With Optional Heatsink
Pin
1
2
3
4
5
6
Single Output
+Vin
-Vin
Remote On/Off
+Vout
-Vout
Trim
Pin
1
2
3
4
5
6
Dual Output
+Vin
-Vin
Remote On/Off
+Vout
Common
-Vout
For the heatsink option, add suffix “H” to the
model number (i.e. MB4048D-12RU-H)
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Heatsink is black, anodized aluminum
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages