ILPA50JW SERIES 50W Water-Proof Constant Current LED Driver – – – – – – – 2 Year Warranty Wide Input Voltage 90 to 264VAC, 47 to 63Hz Constant Output Current Available From 0.35A To 3.0A Over Voltage, Short Circuit, Lighting, and Over Temperature Protection High Efficiency (up to 88%) Active Power Factor Correction (PFC) (87% typical) IP67 Waterproof Rating, Metal Housing Comply with UL8750 & EN61347 Safety Regulation Approvals: Single Output Output Current Range Output Voltage Range Efficiency Over Voltage Protection (Min. / Typ. / Max.) (Min. / Max.) (220VAC, Full Load) (Min/Typ/Max) ILPA50JW-S300SS 2850 / 3000 / 3150 mA 7 / 12 VDC 84% 14 / 16 / 18 VDC ILPA50JW-S277SS 2635 / 2770 / 2905 mA 9 / 18 VDC 85% 22 / 24 / 27 VDC ILPA50JW-S210SS 1995 / 2100 / 2205 mA 13 / 24 VDC 86% 29 / 32 / 36 VDC ILPA50JW-S140SS 1330 / 1400 / 1470 mA 18 / 36 VDC 87% 43 / 48 / 54 VDC ILPA50JW-S119SS 1130 / 1100 / 1250 mA 21 / 45.5 VDC 87% 50 / 57 / 63 VDC ILPA50JW-S105SS 997 / 1050 / 1102 mA 24 / 48 VDC 88% 58 / 65 / 72 VDC ILPA50JW-S070SS 665 / 700 / 735 mA 36 / 72 VDC 88% 86 / 97 / 108 VDC ILPA50JW-S045SS 428 / 450 / 472 mA 56 / 111 VDC 88% 133 / 150 / 167 VDC ILPA50JW-S035SS 333 / 350 / 367 mA 71 / 142 VDC 88% 170 / 192 / 213 VDC Item S300SS, -S277SS, -S210SS use Class 2 output (USR & CNR). Item -S119SS uses Class2 output (USR), Non-Class 2 output (CNR). Item -S140SS, -S105SS, -S070SS,-S045SS,-S035SS use Non-Class 2 output (USR & CNR) Max. Output Power 50W 50W 50W 50W 50W 50W 50W 50W 50W Part Number Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Power Factor Correction Efficiency No-Load Power Consumption Line Regulation Load Regulation Over Voltage Protection Over Temperature Protection Short Circuit Protection Output Overshoot / Undershoot Start Up Time Ripple & Noise (Peak to Peak) Test Conditions Operating Voltage Max. Unit 264 VAC 63 Hz Vin=90 to 264VAC 50 W Io=Full load, Vin=115VAC 0.70 A Io=Full load, Vin=230VAC 0.35 A Io=Full load, 25°C, Cool start, Vin=230VAC 65 A Vin=110VAC 86 87 % Io=Full Load, Vin=220VAC 84 88 % No Load, VIn=230VAC 1 W Io=Full Load 1 % Vin=230VAC 3 % Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) 110 °C No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. When power on or off 10 % Io=Full Load, Vin=100VAC 3 S Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. Min. 90 47 0 Typ. 2 % Vo Conditions Parameter Test Conditions Operating Temperature Humidity: 10% RH to 100% RH Storage Temperature Humidity: 5% RH to 100% RH MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F Life Time at 25°C ambient temperature Min. -35 -40 0.3M 0.08M Typ. Max. 60 85 Unit °C °C Hours Hours Approvals and Compliance Parameter EMI EMS Safety UL/c-UL, CE Waterproof Standards EN55015 EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 IP67 Rating Mechanical Parameter Dimension, Net Weight Specification 162x34.5x42.5mm (6.38x1.36x1.67 inches) 460g approx.