DB Lectro LZ1J100KS Chip type, low impedance Datasheet

LZ Series
CHIP TYPE, LOW IMPEDANCE
Low impedance, temperature range up to +105qC
Load life of 1000~2000 hours
Comply with the RoHS directive (2002/95/EC)
SPECIFICATIONS
Items
Characteristics
Operation Temperature Range
-55 ~ +105°C
Rated Working Voltage
6.3 ~ 50V
Capacitance Tolerance
±20% at 120Hz, 20°C
I d 0.01CV or 3ȝA whichever is greater (after 2 minutes)
Leakage Current
I: Leakage current (PA)
C: Normal capacitance (PF)
Measurement frequency: 120Hz, Temperature: 20°C
WV
6.3
10
16
25
Dissipation Factor max.
tan į
0.22
0.19
Rated voltage (V)
Low Temperature Characteristics
(Measurement frequency: 120Hz)
Impedance ratio
ZT/Z20 (max.)
Load Life
(After 2000 hours (1000 hours for ‡4,
‡5, ‡6.3x5.4) application of the rated
voltage at 105°C, capacitors meet the
characteristics requirements listed.)
0.16
V: Rated voltage (V)
0.14
35
50
0.12
0.12
6.3
10
16
25
35
50
Z(-25°C) / Z(20°C)
2
2
2
2
2
2
Z(-40°C) / Z(20°C)
5
4
4
3
3
3
Capacitance Change
Within r20% of initial value
Dissipation Factor
200% or less of initial specified value
Leakage Current
Initial specified value or less
After leaving capacitors under no load at 105°C for 1000 hours, they meet the specified value
for load life characteristics listed above.
Shelf Life
After reflow soldering according to Reflow Soldering Condition (see page 8) and restored at
room temperature, they meet the characteristics requirements listed as below.
Resistance to Soldering Heat
Capacitance Change
Within r10% of initial value
Dissipation Factor
Leakage Current
Initial specified value or less
Initial specified value or less
Reference Standard
JIS C-5141 and JIS C-5102
DRAWING (Unit: mm)
Cf0.2
Af0.2
E
Bf0.2
‡Df0.5
0.3max.
Af0.2 0.5Max.
Positive
Plastic plateform
Negative
Lr0.3
0.5~0.8
*Voltage mark for 6.3V is [6V]
DIMENSIONS (Unit: mm)
‡D x L
A
B
C
E
L
4 x 5.4
1.8
4.3
4.3
1.0
5.4
5 x 5.4
2.1
5.3
5.3
1.3
5.4
6.3 x 5.4
2.4
6.6
6.6
2.2
5.4
6.3 x 7.7
2.4
6.6
6.6
2.2
7.7
8 x 10.5
2.9
8.3
8.3
3.1
10.5
10 x 10.5
3.2
10.3
10.3
4.5
10.5
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
LZ Series
DIMENSIONS & MAXIMUM PERMISSIBLE RIPPLE CURRENT
6.3
WV
PF
Case size
10
Impedance
R.C.
Case size
16
Impedance
R.C.
Case size
Impedance
R.C.
1.8
(3.0)
1.8
(3.0)
1.0
(1.8)
95
(60)
95
(60)
140
(95)
6.3 x 5.4
1.0
140
6.3 x 7.7
(6.3 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
0.6
(1.0)
0.6
(1.0)
230
(140)
230
(140)
4 x 5.4
5 x 5.4
(4 x 5.4)
5 x 5.4
(4 x 5.4)
6.3 x 5.4
(5 x 5.4)
6.3 x 5.4
(5 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
3.0
1.8
(3.0)
1.8
(3.0)
1.0
(1.8)
1.0
(1.8)
0.6
(1.0)
0.6
(1.0)
60
95
(60)
95
(60)
140
(95)
140
(95)
230
(140)
230
(140)
6.3 x 7.7
0.6
230
6.3 x 7.7
0.6
230
0.30
(0.6)
0.15
(0.30)
0.15
(0.30)
0.15
450
(230)
670
(450)
670
(450)
670
0.15
670
10
15
5 x 5.4
(4 x 5.4)
5 x 5.4
(4 x 5.4)
6.3 x 5.4
(5 x 5.4)
22
4 x 5.4
3.0
60
33
220
5 x 5.4
(4 x 5.4)
5 x 5.4
(4 x 5.4)
6.3 x 5.4
(5 x 5.4)
6.3 x 5.4
(5 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
1.8
(3.0)
1.8
(3.0)
1.0
(1.8)
1.0
(1.8)
0.6
(1.0)
0.6
(1.0)
95
(60)
95
(60)
140
(95)
140
(95)
230
(140)
230
(140)
330
6.3 x 7.7
0.6
230
8 x 10.5
0.30
450
470
8 x 10.5
0.30
450
8 x 10.5
0.30
450
680
8 x 10.5
10 x 10.5
(8 x 10.5)
10 x 10.5
0.30
0.15
(0.30)
0.15
450
670
(450)
670
10 x 10.5
0.15
670
8 x 10.5
(6.3 x 7.7)
10 x 10.5
(8 x 10.5)
10 x 10.5
(8 x 10.5)
10x 10.5
10 x 10.5
0.15
670
10 x 10.5
47
68
100
150
1000
1500
25
WV
PF
Case size
1
1.5
2.2
3.3
4.7
6.8
35
Impedance
R.C.
50
Case size
Impedance
R.C.
Case size
Impedance
R.C.
4 x 5.4
3.0
60
4 x 5.4
5.0
30
4 x 5.4
3.0
60
4 x 5.4
5.0
30
4 x 5.4
3.0
60
4 x 5.4
5.0
30
4 x 5.4
3.0
60
4 x 5.4
5.0
30
4 x 5.4
3.0
60
4 x 5.4
3.0
60
5 x 5.4
3.0
50
4 x 5.4
5 x 5.4
(4 x 5.4)
6.3 x 5.4
6.3 x 5.4
(5 x 5.4)
6.3 x 5.4
(5 x 5.4)
6.3 x 7.7
(6.3 x 5.4)
6.3 x 7.7
3.0
1.8
(3.0)
1.8
1.0
(1.8)
1.0
(1.8)
0.6
(1.0)
0.6
60
95
(60)
95
140
(95)
140
(95)
230
(140)
230
5 x 5.4
5 x 5.4
(4 x 5.4)
5 x 5.4
6.3 x 5.4
(5 x 5.4)
1.8
1.8
(3.0)
1.8
1.0
(1.8)
95
95
(60)
95
140
(95)
6.3 x 5.4
2.0
70
6.3 x 5.4
2.0
70
6.3 x 5.4
6.3 x 7.7
(6.3 x 5.4)
2.0
1.0
(2.0)
70
120
(70)
6.3 x 7.7
1.0
120
150
6.3 x 7.7
8 x 10.5
(6.3 x 7.7)
0.6
0.30
(0.6)
230
450
(230)
220
8 x 10.5
0.30
450
330
10 x 10.5
(8 x 10.5)
10 x 10.5
0.15
(0.30)
0.15
670
(450)
670
10
15
22
33
47
68
100
470
6.3 x 5.4
1.0
140
6.3 x 7.7
(6.3 x 5.4)
6.3 x 7.7
0.60
(1.0)
0.60
230
(140)
230
8 x 10.5
0.30
8 x 10.5
0.30
10 x 10.5
(8 x 10.5)
0.15
(0.30)
6.3 x 7.7
1.0
120
8 x 10.5
0.60
300
450
8 x 10.5
0.60
300
450
10 x 10.5
0.30
500
670
(450)
10 x 10.5
0.30
500
10 x 10.5
0.15
670
10 x 10.5
0.15
670
Case size ∅D×L (mm), maximum impedance (:) at 20qC 100kHz, ripple current (mA rms) at 105qC 100kHz
FREQUENCY COEFFICIENT OF ALLOWABLE RIPPLE CURRENT
Frequency
50Hz
120Hz
300Hz
1KHz
10KHz~
Coefficient
0.35
0.50
0.64
0.83
1.00
Note: All design and specifications are for reference only and is subject to change without prior notice. If any doubt about safety for
your application, please contact us immediately for technical assistance before purchase.
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
EXPLANATION OF PART NUMBERS
1
2
3
4
5
6
7
8
9
10
11
Cap.
Tol.(%)
Dash
Type
Lead
Process
_
ʳ
ʳ
Voltage (WV)
Series
ʳ
Capacitance (PF)
12
13
Dia.(‡)
14
Length (mm)
15
Sleeve
16
Rubber
17
18
Lead Shape
ʳ
ʳ
ʳ (3, 4)
(1, 2)
ʳ
Vol.
Series
(WV)
ʳ
CS
ʳ
CK
ʳ
SC
ʳ
CN
Chip Type
(5~7)
Code
Dia.
(‡)
Code
Length
(mm)
Code
Chip
C
3
S
5
05
-10
Radial
R
4
C
5.4
54
+15
Radial Taping
T
5
D
5.8
58
Snap-in
S
6.3
E
7
07
8
F
7.7
77
10
G
9
09
12
H
10.5
10
Cap.
(PF)
Code
Tol.
(%)
2
0D
0.1
0R1
+10
4
0G
0.22
R22
6.3
0J
0.33
R33
1A
0.47
R47
-15
16
1C
1
010
+20
LZʳ
25
1E
2.2
2R2
-20
KZʳ
35
1V
3.3
3R3
FZ
40
1G
4.7
4R7
50
1H
10
100
63
1J
22
220
100
2A
33
330
ʳ
HUʳ
RAʳ
KH
Code
K
L
10
KL
(13, 14)
(12)
Type
Code
KPʳ
ʳ
EL
ʳ
(10)
(8)
M
(11)
Type
Chip
Descriptions
Code
Taping & Reel
R
Bulk
B
Taping (Forming)
A
12.5
I
11
11
13
J
12
12
13.5
V
14
14
14.5
A
16
16
2C
47
470
16
K
20
20
200
2D
100
101
Taping (Straight)
S
18
L
21
21
RN
250
2E
220
221
Lead Cut
C
20
M
25
25
RT
315
2F
330
331
22
N
26
26
RK
330
2U
470
471
25
O
31
31
RM
350
2V
1000
102
30
P
35
35
RS
400
2G
2200
222
LA
450
2W
3300
332
LK
4700
472
LM
10000
103
LS
22000
223
Radial
160
Snapin
Lead Forming Cut
F
Lead Forming Only
M
Kinked Forming Cut
K
35
Q
36
36
Kinked Straight Cut
Y
40
R
40
40
Lead Snap-in
W
46
46
NP
NK
NM
(15)
(17, 18)
(16)
Sleeve
Code
Rubber
Code
Lead Shape
Code
BP
PVC sleeve (White printing)
W
Plane
P
Standard
00
TM
PVC sleeve (Black printing)
B
Convexity
T
Not standard
01
TN
PVC sleeve (Golden printing)
G
Length after cut is 3mm
30
PVC sleeve (Silver printing)
A
Length after cut is 4.5mm
45
1
Length after cut is 5mm
50
2
Length after cut is 7.5mm
75
3
Length after cut is 10mm
1A
NS
SM
SK
PET sleeve (Green colour
white printing)
PET sleeve (Purple colour
white printing)
PET sleeve (Yellow colour
black printing)
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
CORRESPONDING TO RoHS DIRECTIVE
Aluminum electrolytic
capacitors
Chip type
Radial lead type
Snap-in type
RoHS compliant
Yes
Yes
Yes
Change plating from Sn-Pb to
Sn
Change plating from Sn-Pb to
Sn
Change plating from Sn-Pb to
Sn
Construction of
terminals
Fe/Cu/Sn
Fe/Cu/Sn
Fe/Cu/Sn
Plating
characters
Plating thickness 12Pm
Plating type matte
No heat treatment after plating
Plating thickness 12Pm
Plating type matte
No heat treatment after plating
Plating thickness 10Pm
Plating type matte
No heat treatment after plating
Insulating
sleeve
No used
Replace PVC with PET
(where customer designated)
Replace PVC with PET
(where customer designated)
Resistance to
soldering heat
Please see "Lead Free Reflow
Soldering Condition" for chip
type aluminum electrolytic
capacitors
No change
No change
Solderability
No difference with Sn-Pb
No difference with Sn-Pb
No difference with Sn-Pb
Tensile strength
No difference with Sn-Pb
No difference with Sn-Pb
No difference with Sn-Pb
Whisker
No difference with Sn-Pb
Room storage test: 20~25qC,
30~80%RH, 4000hrs.
Aging test: 60r5qC, 93
+2/-3%RH, 4000hrs.
Thermal cycle test: -55
+0/-10qC to 85 +10/-0qC, 3
cycles/hour, 1000 cycles
No difference with Sn-Pb
Room storage test: 20~25qC,
30~80%RH, 4000hrs.
Aging test: 60r5qC, 93
+2/-3%RH, 4000hrs.
Thermal cycle test: -55
+0/-10qC to 85 +10/-0qC, 3
cycles/hour, 1000 cycles
Whisker is not observed
Room storage test: 20~25qC,
30~80%RH, 4000hrs.
Aging test: 60r5qC, 93
+2/-3%RH, 4000hrs.
Thermal cycle test: -55
+0/-10qC to 85 +10/-0qC, 3
cycles/hour, 1000 cycles
Plating material
< 2ppm
< 2ppm
< 2ppm
Hg
< 2ppm
< 2ppm
< 2ppm
Cd
< 2ppm
< 2ppm
< 2ppm
PBB
Not detected
Not detected
Not detected
PBDE
Not detected
Not detected
Not detected
Identification for RoHS
compliance products
Add "Pb free" or "RoHS"
marking on inner and outer
carton label (where customer
designated)
Add "Pb free" or "RoHS"
marking on inner and outer
carton label (where customer
designated)
Add "Pb free" or "RoHS"
marking on inner and outer
carton label (where customer
designated)
MSL Level
(IPC/JEDEC J-STD-020C)
Not available
No need for dry package
Not available
No need for dry package
Not available
No need for dry package
RoHS
restricted
substances
Most concerns
on terminals
Plating on
terminals
Pb
Cr6+
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
SERIES TABLE
Chip Type Aluminum Electrolytic Capacitors
Applications
Series
Features
Capacitance
(—F)
Rate
Voltage
(V.D.C.)
Operating
Temperature
(°C)
Load
Life
(Hours)
Capacitance
Tolerance
(%)
CS
Standard size
0.1 ~ 1500
4 ~ 100
-40 ~ +85
2000
r20
CK
Standard size, wide temperature
range
0.1 ~ 1500
4 ~ 50
-55 ~ +105
2000
r20
SC
Low leakage current
0.1 ~ 100
6.3 ~ 50
-40 ~ +85
1000
r20
CN
Non-polarized
0.1 ~ 100
6.3 ~ 50
-40 ~ +85
1000
r20
KP
Non-polarized, wide temperature
range
0.1 ~ 47
6.3 ~ 50
-55 ~ +105
1000
r20
LZ
Low impedance
1 ~ 1500
6.3 ~ 50
-55 ~ +105
2000
r20
KZ
Extra low impedance
4.7 ~ 1500
6.3 ~ 50
-55 ~ +105
2000
r20
FZ
Long life, extra low impedance
4.7 ~ 1500
6.3 ~ 35
-55 ~ +105
3000
r20
EL
Long life assurance
0.1 ~ 1500
6.3 ~ 50
-55 ~ +105
3000
r20
KL
5000 hours load life
0.1 ~ 4700
6.3 ~ 100
-40 ~ +105
5000
r20
High Reliability
KH
High reliability
10 ~ 330
10 ~ 50
-40 ~ +125
2000
r20
High Voltage
HU
Mid-to-high voltage
3.3 ~ 68
160 ~ 450
-40 ~ +105
5000
Standard
Low Leakage
Current
Non-polarized
Low
Impedance
Long Life
r20
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
SERIES CHART
z Chip Type Aluminum Electrolytic Capacitors
KP
105qC
Non-polarized
CN
Wide
temperature
85qC
Non-polarized
Non-polarized
CS
SC
85qC Low
leakage current
Low leakage
current
85qC
Standard
Wide temperature
EL
KH
125qC High
reliability
Higher
reliability
105qC Long
life assurance
CK
Longer life
Extra longer life
HU
Mid-to-high
voltage
Higher
Voltage
105qC Wide
temperature
Low impedance
KL
LZ
105qC 5000
hours load life
105qC Low
impedance
Extra Low impedance
FZ
105qC Long life
with extra lower
impedance
KZ
Longer life
105qC Extra
lower
impedance
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
GENERAL INFORMATION FOR APPLICATION
The following precautions must be observed when using electrolytic capacitors.
1. Circuit Design
1) Please make sure that the environmental and mounting conditions to which the capacitor to be
exposed are within the conditions specified in this catalogue.
2) Operating temperature and applied ripple must be within the specifications.
3) Appropriate capacitors, which comply with the life requirement of the products, should be selected
when designing the circuit.
4) Aluminum electrolytic capacitors are polarized. Do not apply reserve voltage or AC voltage. Please
use non-polarized capacitors for a circuit that can possibly see reserved polarity.
Note: Non-polarizes capacitors cannot be used for AC voltage application.
5) Do not use aluminum electrolytic capacitors in a circuit that requires rapid and very frequent charge
or discharge. In this type of circuit, it is necessary to use special design capacitors with extended life
characteristics.
6) Do not apply excess voltage.
M Pleased pay attention so that the peak voltage, which is DC voltage overlapped by ripple current,
should not exceed the rated voltage.
N In the case where more than two aluminum electrolytic capacitors are used in series, please
make sure that applied voltage should be lower than rated voltage should be applied to each
capacitor equally using a balancing resistor in parallel with the capacitor.
7) Outer sleeved of the capacitor is not guarantee as an electrical insulator. Do not use standard sleeve
on a capacitor in applications that require electrical insulation. When the application requires special
insulation, please contact our sales office for details.
8) Capacitors must not be used under following conditions:
M (a) Capacitors must not be exposed to water (including condensation), brine or oil.
(b) Ambient conditions that include toxic gases such as hydrogen sulfide, sulfurous acid, nitrous
acid, chlorine, ammonium, etc.
(c) Ambient conditions that expose the capacitor to ozone, ultraviolet ray and radiation.
N Severe vibration and physical shock conditions that exceed our specification.
Vibration test condition:
Vibration frequency range: 10~55~10Hz
Sweet rate
: 10~55~10Hz per minute
Sweet method
: logarithmic
Amplitude or acceleration: 1.5 (max. acceleration is 10G)
Direction of vibration
: X, Y, Z direction
Testing time
: 2 hours per each direction
Shock is not applicable normally.
If a particular condition is required, please contact our sales office.
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
9) When designing a circuit board, please pay attention to the following:
M Make the pad spacing on the PC board matching with the lead space of the capacitor.
N There should not be any circuit pattern or circuit wire above the capacitor safety vent.
10) The main chemical solution of the electrolyte and the separator paper in the capacitor are
combustible. The electrolyte is conductive. When it comes in contact with the PC board, there is a
possibility of pattern or short circuit between the circuit pattern, which could result in smoking or fire.
Do not locate any circuit pattern beneath the capacitor end seal.
11) Do not design a circuit board so that heat generating components are placed near an aluminum
electrolytic capacitor or reserve side of PC board (under the capacitor).
12) Please refer to the pad size layout recommendations in our catalogue when designing in surface
mount capacitors.
13) Electrical characteristics may vary depending on changes in temperature and frequency. Please
consider the variation when you design circuits.
14) When you install more than 2 capacitors in parallel, consider the balance of current following in to the
capacitor.
2. Mounting
1) Once a capacitor has been assembled in the set and power applied, do not attempt to re-use the
capacitor in other circuits or application.
2) Electric potential between positive and negative terminal may exist as a result of returned
electromotive force, so please discharge the capacitor using 1K: resistor.
3) Leakage current of the parts that have stored for long period may increase. When leakage current
4)
5)
6)
7)
8)
has increased, please perform a voltage treatment using a 1K: resistor.
Please confirm rating and polarity before installing capacitor on the PC board.
Be careful not to deform the capacitor during installation.
Please confirm that the lead spacing of the capacitor matches the pad spacing of the PC board prior
to installation.
Please pay attention to the mechanical shock to the capacitor by suction nozzle of the automatic
insertion machine or automatic mounted, or by product checker, or by centering mechanism.
Reflow soldering: Please see "Lead Free Reflow Soldering Condition" for chip type aluminum
electrolytic capacitors (page 8).
9) Do not tilt, lay down or twist the capacitor body after the capacitors are soldered to the PC board.
10) Do not carry the PC board by grasping the soldered capacitor.
11) Please do not allow anytime to touch the capacitor after soldering. If PC board are stored in stack,
please make sure PC board or the other components do not touch the capacitor. The capacitor shall
not be effected by any radiated heat from the soldered PC board or other components after
soldering.
12) Cleaning
M Do not clean capacitors with halogenated cleaning agent. However, if it is necessary to clean with
halogenated cleaning agent, please contact our sales office.
N Recommended cleaning method:
Applicable
: Any type, any ratings
Cleaning agents : Pine Alpha ST-100S, cleaning through 750H/750L/710M, Sanelek B-12, Aqua
Cleaner 210SEP, Techno Care FRW14~17, Isopropyl Alcohol.
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
Cleaning condition: Total cleaning time shall be within 5 minutes by immersion, ultrasonic or other
method. Temperature of the cleaning agent shall be 60qC or lower. After
cleaning, capacitors should be dried using hot air for minimum of 10 minutes
along with the PC board. Hot air temperature should be below the maximum
operating temperature of the capacitor. Insufficient dry after water rinse may
cause appearance problems, sleeve shirk, bottom- plate bulge and such.
e Avoid using ozone destructive substance for cleaning agents to concern about global
environment. Please consult us regarding other cleaning agents or cleaning methods.
3. In The Equipment
1) Do not directly touch terminal by hand.
2) Do not short between terminal by conductor, nor spill conductible liquid such as alkaline or acidic
solution on or near the capacitor.
3) Please make sure that the ambient conditions where the set is installed will be free from spilling water
or oil, direct sunlight, ultraviolet rays, radiation, poisonous gases, vibration or mechanical shock.
4. Maintenance and Inspection
Please periodically inspect the aluminum capacitors that are installed in industrial equipment. The
following Items should be checked:
Appearance: Remarkable abnormality such as vent operation, leaking electrolyte etc.
Electrical characteristic: Capacitance, dielectric loss tangent, leakage current etc., which are specified
in this catalogue.
5. In an Emergency
1) If you see smoke due to operation of safety vent, turn off the main switch or pull out the plug from the
outlet.
2) Do not draw your face to the safety vent since gas over 100qC will be emitted when the safety vent
operates. If the gas has entered your eyes, please flush your eyes immediately in pure water. If you
breathed the gas immediately wash out your mouth and throat with water. Do not ingest electrolyte. If
your skin is exposed to electrolyte, please wash it away using soap and water.
6. Storage
1) Do not keep capacitor in high temperature and high humidity.
Storage conditions should be:
Temperature : +5qC ~ +35qC
Humidity
: Lower than 75%
Place
: Indoor
2) Avoid ambient conditions where capacitors can be covered with water, brine or oil.
3) Avoid ambient conditions where capacitors are exposed to poisonous gases such as hydrogen sulfide,
sulfurous acid, nitrous acid, chlorine, ammonium etc.
4) Do not keep capacitor in conditions that expose the capacitor to ozone, ultraviolet ray or radiation.
7. Disposal
Please dispose capacitors in either of the following ways:
1) Incinerate capacitors after crushing parts or making a hole on the capacitor body.
2) Bury capacitors in the ground. Please have a disposal specialist do it.
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
LEAD FREE REFLOW SOLDERING CONDITION
(Applicable to Chip Type Aluminum Electrolytic Capacitors)
„ Recommended Conditions for Reflow Soldering
(1) A thermal condition system such as infrared radiation (IR) or hot blast should be adopted, and
vapor heat transfer systems (VPS) are not recommended.
(2) Reflow soldering should be performed one time. If the capacitor has to be reflowed twice, 30
minutes must be layout between each time.
(3) For lead-free type reflow soldering, please observe proper conditions below:
a) The time of preheating from 150°C to 200°C shall be within maximum 180 seconds;
b) The time of soldering temperature at 217°C measured on capacitors' top shall not exceed
tL (second);
c) The peak temperature on capacitors' top shall not exceed Tp(°C), and the time within 5°C
of actual peak temperature shall not exceed tp (second).
„ Classification Reflow Profile
tp
Tp
Ramp-up
Critical Zone
217 t o Tp
*1
Te m p er a tu r e
21 7
t
20 0
L
Ramp-down *2
15 0
P re h e a t 1 8 0 s ec Ma x
25
2 5 ¤ to Pe a k * 3
*1. Average ramp-up rate is 3ć/second max.
*2. Ramp-down rate is 6ć/second max.
*3. Time from 25ć to peak temperature is 8 minutes max.
T im e
„ Allowable Range of Peak Temperature
3
Size
Thickness (mm)
Volume (mm )
Tp(°C)
tL (second)
tp (second)
‡4~‡6.3, ‡8u6.2L
t2.5
<350
250±0
90
5
‡8u10.5L
t2.5
350~2000
240±0
90
5
‡10u10.5L/13.5L
t2.5
350~2000
235±0
60
5
‡12.5, ‡16
t2.5
>2000
230±0
30 (20*)
5
Re: (20*) is special for mid-to-high voltage which is HU series.
„ Recommended Land Size (Unit: mm)
Size
a
b
c
‡4
1.6
2.6
1.6
‡5
1.6
3.0
1.6
‡6.3
1.6
3.5
1.6
‡8×6.2L
2.1
4.5
1.6
‡8×10.5L
3.0
3.5
2.5
‡10
4.0
4.0
2.5
‡12.5
4.0
5.7
3.0
‡16×16.5/21.5
6.0
6.5
3.5
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
Taping Specifications for Chip Type Aluminum Electrolytic Capacitors
„ Carrier Tape
Drawing 1 (for ‡4 ~ ‡10)
4.0±0.1
2.0±0.1
‡1.5 +0.1~-0
0.4
1.75±0.1
B±0.2
P±0.1
W±0.3
F±0.1
A±0.2
Dimension
T2±0.2
(Unit: mm)
‡DuL
4u5.4/5.8
5u5.4/5.8
6.3u5.4/5.8
6.3u7.7
8u6.2
8u10.5
10u10.5/13.5
W
12.0
12.0
16.0
12.0
16.0
24.0
24.0
P
8.0
12.0
12.0
12.0
12.0
16.0
16.0
F
5.5
5.5
7.5
7.5
7.5
11.5
11.5
A
5.0
6.0
7.0
7.0
8.7
8.7
10.7
B
5.0
6.0
7.0
7.0
8.7
8.7
10.7
T2
5.8/6.3
5.8/6.3
5.8/6.3
8.4
6.8
11.0
11.0/14.0
Drawing 2 (for ‡12.5 ~ ‡16)
Dimension
(Unit: mm)
‡DuL
12.5u13.5
12.5u16
Wr0.3
32.0
32.0
Pr0.1
24.0
24.0
Fr0.1
14.2
14.2
A0r0.2
14.0
14.0
B0r0.2
14.0
14.0
T2r0.2
14.0
16.5
Sr0.1
28.4
28.4
B
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
„ Reel
3
13r0.5
B
‡50 Min.
23
2.0
A
(Unit: mm)
‡DuL
4u5.4/5.8
5u5.4/5.8
6.3u5.4/5.8/7.7
8u6.2/10.5
10u10.5
10u13.5
12.5u13.5/16
16u16.5
A
14
14
18
26
26
26
34
46
B
382
382
382
382
382
382/332*
382/332*
332*
*For a small package
„ Package Quantity
Size
(‡DuL)
Reel
(pcs)
In-box
(reels)
Quantity/In-box
(pcs)
4 In-boxes/Carton
(pcs)
4u5.5/5.8
2,000
6
12,000
48,000
5u5.4/5.8
1,000
6
6,000
24,000
6.3u5.4/5.8
1,000
5
5,000
20,000
6.3u7.7
1,000
5
5,000
20,000
8u6.2
1,000
5
5,000
20,000
8u10.5
500
4
2,000
8,000
10u10.5
500
4
2,000
8,000
10u13.5
300/250*
4
1,200/1,000*
4,800/4000*
12.5u13.5
200/150*
3
600/450*
2,400/1,800*
12.5u16
200/150*
3
600/450*
2,400/1,800*
16u16.5
125*
2
250*
1,000*
Note: All design and specifications are for reference only and is subject to change without prior notice. If any doubt about safety
for your application, please contact us immediately for technical assistance before purchase.
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
LIFE OF ALUMINUM ELECTROLYTIC CAPACITORS
The life of aluminum electrolytic capacitors is mainly dependent on environmental conditions (e.g.
ambient temperature, humidity etc.) and electrical factors (e.g. operating temperature, ripple current
etc.) Generally, the wear-out mechanism of aluminum electrolytic capacitors is based on evaporation
of electrolyte through the rubber seal. Consequently, the factor of temperature (ambient temperature
and internal heating due to ripple current) is the most critical to electrolytic capacitors life. The effect of
voltage on capacitor life is negligible, especially for low voltage electrolytic capacitors. The lifetime of
aluminum electrolytic capacitors can be expressed as following equations:
Le = Lo x Kt x Kr
-------- (1)
Where:
Le = Expected life at operating temperature Te (h)
Lo = Specified life at temperature operating temperature To (h)
Kt = Ambient temperature acceleration term
Kr = Ripple current acceleration term
(To-Te)/10
Kt = Lo x A
-------- (2)
Where:
To = Maximum rated operating temperature (qC)
Te = Actual ambient temperature (qC)
A = Acceleration coefficient (for the range from 35qC to the maximum operating temperature,
A|2)
Kr = 2 (-'T/5)
-------- (3)
Where:
'T = An increase in core temperature by internal heating due to ripple current
('T = core temperature – ambient temperature)
'T can be estimated as follows:
'T = (I2 x R)/(E x S) -------- (4)
Where:
I = Ripple current of the capacitor (A rms)
R = Equivalent series resistance of the capacitor (:)
E = Heat radiation coefficient of the aluminum can (W/qC x cm2)
S = Surface area of the capacitor (cm2)
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
Similar pages