HY HS3BB Surface mount glass high efficiency rectifier Datasheet

HS3AB thru HS3MB
SURFACE MOUNT
REVERSE VOLTAGE - 50 to 1000 Volts
FORWARD CURRENT - 3.0 Amperes
GLASS HIGH EFFICIENCY RECTIFIERS
SMB
FEATURES
● Low cost
● Diffused junction
● Ultra fast switching for high efficiency
.083(2.11)
.075(1.91)
● Low reverse leakage current
.155(3.94)
.130(3.30)
● Low forward voltage drop
● High current capability
.185(4.70)
.160(4.06)
● The plastic material carries UL recognition 94V-0
.012(.305)
.006(.152)
.096(2.44)
.084(2.13)
MECHANICAL DATA
●Case: Molded Plastic
.060(1.52)
.030(0.76)
●Polarity:Color band denotes cathode
.008(.203)
.002(.051)
.220(5.59)
.200(5.08)
●Weight: 0.003 ounces,0.093 grams
●Mounting position: Any
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
CHARACTERISTICS
SYMBOL HS3AB HS3BB HS3DB HS3GB HS3JB HS3KB HS3MB
Maximum Recurrent Peak Reverse Voltage
VRRM
50
Maximum RMS Voltage
VRMS
VDC
Maximum DC Blocking Voltage
Maximum Average Forward
@TA =55 ℃
Rectified Current
100
200
400
600
800
35
70
140
280
420
50
100
200
400
600
UNIT
1000
V
560
700
V
800
1000
V
I(AV)
3.0
A
IFSM
150
A
Peak Forward Surage Current
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load(JEDEC Method)
Peak Forward Voltage at 3.0A DC(Note1)
Maximum DC Reverse Current
@TJ=25℃
at Rated DC Blocking Voltage
@TJ=100℃
Maximum Reverse Recovery Time(Note 1)
Typical Junction Capacitance (Note2)
Typical Thermal Resistance (Note3)
Operating Temperature Range
Storage Temperature Range
1.3
1.0
VF
1.7
5.0
IR
V
uA
100
TRR
50
75
nS
CJ
50
30
pF
RθJA
20
℃/W
TJ
-50 to +150
℃
TSTG
-50 to +150
℃
NOTES: 1.Measured with IF=0.5A,IR=1A ,IRR=0.25A
2.Measured at 1.0 MHz and applied reverse voltage of 4.0V DC
3.Thermal resistance junction to ambient
~ 111 ~
RATING AND CHARACTERTIC CURVES
HS3AB thru HS3MB
FIG. 1 – FORWARD CURRENT DERATING CURVE
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
2.5
2.0
1.5
1.0
0.5
0
25
50
75
100
125
150
200
PEAK FORWARD SURGE CURRENT
(AMPERES)
AVERAGE FORWARD CURRENT
AMPERES
3.0
FIG. 2 – MAXIMUM NON-REPETITIVE SURGE CURRENT
150
100
50
SINGLE HALF-SINE-WAVE
(JEDEC METHOD)
0
175
1
2
10
20
50
100
NUMBER OF CYCLES AT 60Hz
AMBIENT TEMPERATURE (℃)
FIG.4-TYPICAL FORWARD CHARACTERISTICS
FIG.3 – TYPICAL JUNCTION CAPACITANCE
100
INSTANTANEOUS FORWARD CURRENT
(AMPERES)
1000
HS3AB - HS3GB
100
CAPACITANCE (pF)
5
HS3JB - HS3MB
10
T J = 25°C f = 1 MHz
HS
10
3GB
HS3AB - HS3DB
HS3JB-HS3MB
1.0
TJ = 25°C
PULSE WIDTH 300us
0.1
1
0.1
1.0
10
0
100
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
REVERSE VOLTAGE (VOLTS)
~ 112 ~
1.8