Click on Series name for product info on aimtec.com Series AM4TW-RVZ 4 Watt | DC-DC Converter FEATURES: Models Single output Model Wide Input Range (4:1) 24 Pin DIP Package Metal package High efficiency up to 75% Operating temperature -40oC to + 85oC Input / Output isolation 1500 VDC Pin compatible with multiple manufacturers Continuous short circuit protection Input Voltage (V) Output Voltage (V) Output Current max (mA) Capacitive load, max (μF) Efficiency (%) 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 1000 800 333 266 1000 800 333 266 1000 1000 320 220 1000 1000 320 220 66 71 74 74 66 72 73 74 Input Voltage (V) Output Voltage (V) 9-36 9-36 9-36 18-72 18-72 18-72 ±5 ±12 ±15 ±5 ±12 ±15 AM4TW-2403S-RVZ AM4TW-2405S-RVZ AM4TW-2412S-RVZ AM4TW-2415S-RVZ AM4TW-4803S-RVZ AM4TW-4805S-RVZ AM4TW-4812S-RVZ AM4TW-4815S-RVZ Models Dual output Model AM4TW-2405D-RVZ AM4TW-2412D-RVZ AM4TW-2415D-RVZ AM4TW-4805D-RVZ AM4TW-4812D-RVZ AM4TW-4815D-RVZ Output Current max (mA) ±400 ±166 ±133 ±400 ±166 ±133 Capacitive load, max (μF) Efficiency (%) ±470 ±100 ±68 ±470 ±100 ±68 70 72 75 70 72 73 Maximum Units Input Specifications Parameters Voltage Range Filter Start up time Peak Input Voltage time Absolute Max Rating Nominal Typical 24 48 9-36 18-72 24 Vin 20 15 -0.7-40 VDC (Pi) Network Ms Ms VDC Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 3 sec Rated Units 1500 VDC MOhm pF > 1000 60 Output Specifications Parameters Voltage Balance Voltage accuracy Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise* Conditions Typical Balanced Load ±1 ±1 Maximum Units % % Continuous Auto Recovery At 20MHz Bandwidth ±0.5 ±0.5 ±0.02 60 % % %/oC mV p-p * In order to achieve ripple and noise specification, a 100μF capacitor is required to be connected to the output of the converter www.aimtec.com F 051e R13.C Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4TW-RVZ 4 Watt | DC-DC Converter General Specifications Parameters Conditions Typical Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions(L x W x H) MTBF 100% load Full Load (see derating chart) 100-400 Maximum Units 100 KHz oC oC oC -40 to +85 -40 to +125 Free air convection 95 % Nickel coated copper 12.16 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm >2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Standards Designed to meet IEC 60950-1 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Pin 2 3 9 11 14 16 22 23 1500 VDC Single Dual -V Input -V Input No pin N.C. +V Output -V Output +V Input +V Input -V Input -V Input Common -V Output +V Output Common +V Input +V Input www.aimtec.com F 051e R13.C Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4TW-RVZ 4 Watt | DC-DC Converter 3.05 (0.12) 10.16 (0.40) 20.32 (0.80) 15.24 (0.60) Dimensions Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only