MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Functional Schematic, Default On, Power Off Features Rev. V3 S2 Always ON loop-thru path 2-Way Splitter 4.0 dB Gain 15 dBmV /Channel Input 4.5 dB Noise Figure Single 5 Volt Bias Lead-Free 3 mm PQFN 12-Lead Package RoHS* Compliant and 260°C Reflow Compatible Vc AIN FB 1 OUT1 IN N/C OUT2 N/C Description The MAAM-009879 CATV 2-way active splitter with the default loop-thru path is a GaAs MMIC which exhibits low noise figure and distortion in a lead-free 3 mm PQFN 12-lead plastic package. The design features 75 Ω inputs and outputs. S1 ALT N/C Functional Schematic, Power On S2 The MAAM-009879 is ideally suited for multi-tuner set top boxes, home gateways, and other broadband internet based applications. Vc AIN FB 1 OUT1 IN The MAAM-009879 is fabricated using MACOM’s E/D pHEMT process to realize default loop-thru operation, low noise and low distortion. The process features full passivation for robust performance and reliability. N/C OUT2 N/C S1 ALT N/C Pin Configuration Ordering Information1,2 Part Number Package MAAM-009879-TR1000 1000 piece reel MAAM-009879-TR3000 3000 piece reel MAAM-009879-001SMB Sample Test Board Pin No. Pin Name Description 1 VC Voltage Control 2 IN RF Input 3 OUT2 RF Output 2 4 S1 Switch Loop thru In 5 ALT Alternate Output 6 N/C No Connection 7 N/C No Connection 8 N/C No Connection 1. Reference Application Note M513 for reel size information. 2. All sample boards include 5 loose parts. 9 OUT1 RF Output 1 10 FB Amplifier Feedback 11 AIN Amplifier Input 12 S2 Switch Output 13 Paddle3 RF and DC Ground 3. The exposed pad centered on the package bottom must be connected to RF, DC and thermal ground. 1 * Restrictions on Hazardous Substances, European Union Directive 2011/65/EU. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Electrical Specifications: Freq. = 1000 MHz, TA = 25°C, Z0 = 75 Ω4 Parameter Test Conditions VDD VC Units Min. Typ. Max. Gain In to Out1 or 2 5 3.3 dB 3.0 4.0 5.5 Insertion Loss In to Out2 0 0 dB - 0.6 0.8 Noise Figure In to Out1 or 2 5 3.3 dB - 4.5 - Gain Flatness In to Out1 or 2 5 3.3 dB - 1.5 - Input Return Loss Input 5 3.3 dB - 12 - Input Return Loss Input 0 0 dB - 14 - Output Return Loss Out1 or 2 5 3.3 dB - 13 - Output Return Loss Out2 0 0 dB - 15 - Out to Out Isolation Out1 to Out2 5 3.3 dB - 22 - Out to Out Isolation Out1 to Out2 0 0 dB - 45 - CTB 132 Ch, +15 dBmV/Ch at the Input 5 3.3 dBc - -65 - CSO 132 Ch, +15 dBmV/Ch at the Input 5 3.3 dBc - -60 - Reverse Isolation Out1 to In 5 3.3 dB - 30 - Reverse Isolation Out2 to In 5 3.3 dB - 23 - Reverse Isolation Out1 to In 0 0 dB - 45 - OIP2 500 MHz, 2-tone, 6 MHz spacing, -10 dBm Pout 5 3.3/0 dBm - 42 - OIP3 500 MHz, 2-tone, 6 MHz spacing, -10 dBm Pout 5 3.3/0 dBm - 22 - P1dB 500 MHz 5 3.3 dBm - 6 - P1dB 500 MHz 5 0 dBm - 15 - IDD — 5 3.3 mA 80 100 120 IC — 5 3.3 µA - 200 250 4. The unpowered state is the same as VCONTROL =0 V 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Truth Table10 Absolute Maximum Ratings5,6,7 Parameter Absolute Maximum VDD VCONTROL IN - OUT1 IN - OUT2 Max Input Power 5 dBm 1 1 On On VDD 10.0 V 0 0 Off On VCONTROL 8.5 V Operating Temperature -40°C to +85°C Junction Temperature 8 +150°C Storage Temperature -65°C to +150°C 10. Logic “1” for VDD = +5 volts and VCONTROL = +3.3 volts typical. Handling Procedures 5. Exceeding any one or combination of these limits may cause permanent damage to this device. 6. MACOM does not recommend sustained operation near these survivability limits. 7. These operating conditions will ensure MTTF > 1 x 106 hours. 8. Junction Temperature (TJ) = TA + Өjc * (V * I) Typical thermal resistance (Өjc) = 73 °C/W. a) For TA = +25°C, TJ = +66°C @ 5 V, 110 mA b) For TA = +85°C, TJ = +122°C @ 5 V, 100 mA Schematic Including Off-Chip Components9 Please observe the following precautions to avoid damage: Static Sensitivity These electronic devices are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. An external protection circuit using an inexpensive anti -parallel diode pair can be used to protect the IC. Please reference application note AN3028 on http://www.macomtech.com for further detail. C7 C10 R2 R1 C8 Vdd Power On Condition C6 L2 L1 C1 C9 R3 Vc L3 RFC OUT1 C2 R5 OUT2 C3 R6 C4 L4 C5 R4 9. The exposed pad centered on the package bottom must be connected to ground for RF, DC and thermal considerations. 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Recommended PCB PCB Land Pattern Block Diagram RF Signal Flow Off-Chip Component Values Component Value Package C1 - C9 0.01 µF 0402 C10 1.0 pF 0402 1 µH 1210 R1, R2 300 Ω 0402 R3 130 Ω 0402 R4 180 Ω 0402 R5, R6 22 kΩ 0402 L2 - L4 7.5 nH 0402 L1 11 11. L1 supplied from EPCOS, part number B82422A1102K100. 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Typical Performance Curves Gain Gain to 3 GHz 6 10 5 0 4 -10 3 2 -20 in to out1_+25° in to out2_+25° in to out1_-40° in to out2_-40° in to out1_+85° in to out2_+85° 1 0 0.0 0.2 0.4 -30 0.6 0.8 1.0 1.2 0.0 in to out1_+25° in to out2_+25° in to out1_-40° in to out2_-40° in to out1_+85° in to out2_+85° 0.5 Frequency (GHz) 1.0 1.5 2.0 2.5 3.0 1.0 1.2 1.0 1.2 Frequency (GHz) Input Return Loss (power on) Input Return Loss (power off) 0 0 -5 +25°C -40°C +85°C -5 +25°C -40°C +85°C -10 -15 -10 -20 -15 -25 -30 -20 -35 -25 0.0 0.2 0.4 0.6 0.8 1.0 1.2 -40 0.0 0.2 0.4 0.6 0.8 Frequency (GHz) Frequency (GHz) Output Return Loss (power on) Output Return Loss (power off) 0 0 in to out1_+25° in to out2_+25° in to out1_-40° in to out2_-40° in to out1_+85° in to out2_+85° -5 -10 in to out1_+25° in to out2_+25° in to out1_-40° in to out2_-40° in to out1_+85° in to out2_+85° -5 -10 -15 -15 -20 -25 -20 -30 -25 -35 -30 0.0 0.2 0.4 0.6 0.8 Frequency (GHz) 1.0 1.2 -40 0.0 0.2 0.4 0.6 0.8 Frequency (GHz) 5 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Typical Performance Curves Insertion Loss to 3 GHz (power off) Insertion Loss to 1 GHz (power off) 0.0 0 -1 -0.5 -2 -1.0 +25°C -40°C +85°C -3 +25°C -40°C +85°C -1.5 -2.0 0.0 0.2 0.4 -4 0.6 0.8 1.0 1.2 -5 0.0 0.5 Frequency (GHz) 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) Reverse Isolation to 3 GHz (power on) Reverse Isolation to 3 GHz (power off) 0 -10 out1 to in_+25° out2 to in_+25° out1 to in_-40° out2 to in_-40° out1 to in_+85° out2 to in_+85° -10 +25°C -40°C +85°C -20 -30 -40 -20 -50 -30 -60 -70 -40 -80 -50 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) -90 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) Noise Figure 7 6 5 4 3 in to out1_+25° in to out2_+25° in to out1_-40° in to out2_-40° in to out1_+85° in to out2_+85° 2 1 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Frequency (GHz) 6 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Typical Performance Curves Out to Out Isolation to 1 GHz (power on) Out to Out Isolation to 3 GHz (power on) 0 0 -5 -5 +25°C -40°C +85°C -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 -35 -40 -40 -45 0.0 0.2 0.4 0.6 0.8 1.0 1.2 -45 0.0 +25°C -40°C +85°C 0.5 Frequency (GHz) 1.5 2.0 2.5 3.0 Frequency (GHz) Out to Out Isolation to 3 GHz (power off) Out to Out Isolation to 1 GHz (power off) -20 -20 -30 -30 -40 -40 -50 -50 -60 -60 +25°C -40°C +85°C -70 1.0 +25°C -40°C +85°C -70 -80 -80 -90 0.0 0.2 0.4 0.6 0.8 Frequency (GHz) 1.0 1.2 -90 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) 7 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 Lead-Free 3 mm 12-Lead PQFN† † Reference Application Note S2083 for lead-free solder reflow recommendations. Meets JEDEC moisture sensitivity level 1 requirements. Plating is 100% matte tin over copper. 8 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAM-009879 Broadband CATV 2-Way Active Splitter with default loop-thru Switch 50 - 1100 MHz Rev. V3 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 9 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macomtech.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support