Melexis MLX90809LXGEAD-003RE Relative pressure sensor Datasheet

MLX90809
Relative Pressure Sensor
Features and Benefits
Application Examples
 High accuracy relative pressure sensor (+/1.5%FSO)
 Ratiometric Analog Output or digital SENT
output
 Fully integrated IC: MEMS, analog front end
circuitry, 16 bit microcontroller, analog back
end circuitry, voltage regulators
 Large automotive temperature range (-40°C to
150°C)
 Automotive qualified and automotive
diagnostic features (clamping levels, broken
track diagnostics, multiple internal fault
diagnostics)
 Factory calibrated and/or fully programmable
through the connector for customized
calibration curves
 Back side exposed relative pressure sensor
for higher resistance to common automotive
media
 Assembled in a robust easy to seal package
 Automotive applications
 Vacuum measurement
 Clogged filter detection
 Seat lumbar cushion sensor
 Industrial applications
 Vacuum sensor
 Process monitoring
 Fluid pressure (low pressure/high
accuracy)
 Consumer/Home appliance applications
 Filter monitoring
 Dispensing/metering systems
 White goods
Ordering Information
Part No.
MLX90809
MLX90809
MLX90809
Temperature Code
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
Option code legend:
Rev 002
390109080901
Package Code
XG
XG
XG
Option Code
EAD-000
EAD-003
EAD-100
Packing Form Code
RE
RE
RE
EAD-000 = 0.05 to -1.05 bar relative pressure / 0.5 to 4.5 V analog output
EAD-003 = 0 to 1 bar relative pressure / 0.5 to 4.5 V analog output
EAD-100 = 0.05 to -1.2 bar relative pressure / 193 to 3896 LSB SENT output
Page 1 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
1 Functional Diagram
2 General Description
Broken wire
detection
Test
Temperature
sensor
Piezoresistive
sensing element
OPA
Micro controller
M
U
X
ADC
16 bits
Analog driver
Gain & Offset temperature
compensation
Pressure Linearization
DAC
Analog
Output
Gain
12 bits
Programmable filter
Diagnostics Logic
Diagnostic signals
Vext
Analog & Digital
Regulator and
POR
DSP
Gain & Offset
compensation
Overvoltage &
reverse voltage
protection
Rom
FW
EE
PROM
SENT driver
Ram
Slew
rate
control
SENT
Output
Ground
The MLX90809 is a packaged, factory calibrated,
integrated relative pressure sensor delivering a
ratiometric analog or digital (using the SENT
protocol) signal.
Use of an optimized architecture and a high
density CMOS technology imparts the 90809 with
best in class automotive EMC performance. A
DSP based architecture using a 16bit
microcontroller provides outstanding performance.
A smart package and die assembly concept suits
applications with stringent automotive temperature
and stress conditions needing small drift over life.
3 Glossary of Terms
Bar: Pressure unit (1bar = 100kPa)
ADC: Analog to Digital Converter
DAC: Digital to Analog Converter
DSP: Digital Signal Processor
EMC: Electro Magnetic Compatibility
SENT: Single Edge Nibble Transmission
FSO: Full Span Output
4 Absolute Maximum Ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximumrated conditions for extended periods may affect device reliability.
Parameter
Remarks Value
Supply Voltage (overvoltage)
Remark 1
18
Reverse Voltage Protection
Remark 2
-14
Positive output voltage
Remark 1
18
Reverse output voltage
Remark 1
-0.5
Operating Temperature Range
-40 to 150
Storage Temperature Range
-40 to 150
Burst pressure (Room Temperature)
5
(AEC Q100 002)
Table 1: Absolute maximum ratings
Units
V
V
V
V
C
C
Bar
Remark 1: No time limit or temperature limit for these over voltage conditions.
Remark 2: Reverse Voltage Protection at -14V at 150C for maximum 1 hour. At Room Temperature that
condition can apply for maximum 24 hours.
Rev 002
390109080901
Page 2 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
5 Pin Definitions and Descriptions
ZZZZZZZZZZ
ZZZZZZZZZZ
Symbol
VVVVV-vvv
YYWW
YYWW
Function / Description
Device used- design revision
YY
Year of assembly
WW
Calendar week of assembly
ZZZZZZZZZZ
Wafer lot number
MLXVVVVV-vvv
MLXVVVVV-vvv
Figure 1: Package marking and pin out (Top view: left; Bottom view: right)
Pin number
1
2
3
4
5
6
7
8
Description
SENT output
SENT output
Supply Input
Test pin
Not connected
Ground
Analog output
Analog output
Pin number
16
15
14
13
12
11
10
9
Description
SENT output
SENT output
Supply Input
Test pin
Not connected
Ground
Analog output
Analog output
Table 2: Pin out definitions and descriptions
Only one of the application pins needs to be connected: one of the Supply Input pins (3 or 14), one of the
Ground pins (6 or 11) and one of the selected (either analog (7,8,9,10) or SENT(1,2,15,16)) output pins. See
section 9 for the detailed information on the application pins connections.
Symbol
VVVVV-vvv
Function / Description
Device used- design revision
YY
Year of assembly
WW
Calendar week of assembly
ZZZZZZZZZZ
Wafer lot number
Table 3: Package label definition
Rev 002
390109080901
Page 3 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
6 General Electrical Specifications
°
°
DC Operating Parameters TA = -40 C to 150 C, VDD = 5V (unless otherwise specified).
Parameter
Nominal supply voltage
Nominal supply current
Load resistance
Capacitive load
Diagnostic limits
Clamping levels
Analog saturation output level
Symbol
Vdd
Idd
Rload
Cload
Diag low
Diag high
Diag high
Clamp low
Clamp high
Remarks
Min
4.5
No output load connected
Pull up or Pull down
4.7
2.2
Pull up > 4.7kOhm
Pull down>4.7kOhm
Pull down>10kOhm
Programmable range with 8 bit resolution for the low
clamping level, 9 for the high (for the default
programmed levels see section 8), +/-10mV accuracy
on the programmed clamping level
96
98
0
50
Vsat high
Vsat low
Typ
5
7
Max
5.5
8
25
100
Units
V
mA
kOhm
nF
%Vdd
%Vdd
%Vdd
%Vdd
%Vdd
97
%Vdd
470
2
2
%Vdd
Power up time
Time from reaching minimum allowed supply voltage of
4.5V till having the output within specification
5.5
msec
Response time
Time needed for the output to react to a pressure
change from 10% to 90% of its final value (pressure
change corresponding to maximum a 4V output
change). Using default filter settings SSF = 1, PFLT =
0.
1
msec
Programmable pressure spans
(Positive pressure on package
top side, see remark 3, 5)
The pressure spans defined correspond to an analog
output span of 4V or to the 12 bit pressure information
on the SENT output
0.5
1
bar
Relative
Programmable pressure spans
(vacuum on package top side,
see remark 3,5)
The pressure spans defined correspond to an analog
output span of 4V or to the 12 bit pressure information
on the SENT output
Remark
4
-0.5
bar
Relative
Overall accuracy
Taking into account the drifts over temperature and
over life
1.5
%FSO
0.2
%Vdd
Ratiometricity error
Output noise analog output
BW limited to 50kHz. Using default filter settings SSF =
1, PFLT = 0.
2
mVrms
Output noise SENT output
BW limited to 50kHz. Using default filter settings SSF =
1, PFLT = 0.
1.8
LSBrms
Table 4: Electrical specifications
Remark 3: The top side of the package is defined as the side with the small hole and readable marking.
Remark 4: There are no limitations on the vacuum level that the MLX90809 can measure.
Remark 5: The pressure span is defined as being equal to UPL-LPL (upper pressure limit minus lower
pressure limit like described for the default calibrated curve in paragraph 8). The atmospheric pressure
should always belong to the programmed transfer function.
Rev 002
390109080901
Page 4 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
7 Detailed General Description
The pressure sensing element consists of a square diaphragm realized in the silicon chip by backside
etching. The diaphragm reacts to a pressure difference between the top and bottom side of the diaphragm.
The internal strain increases, in particular at the border of the diaphragm. Here, the piezo-resistive elements
have been implanted into the silicon diaphragm, which act as a transducer.
The electronics front end amplifies the signal from the bridge, performs a coarse offset compensation and an
ADC conversion. The DSP performs the compensations over temperature. Furthermore, the digital circuit
provides some filtering, the possibility to linearize the pressure signal and also implements the clamping
function. The analog back end consists of a 12 bit DAC and an output driver. This chip delivers an analog
output proportional to the pressure or a SENT output compliant with SAE J2716 spec dated January 2010.
A broken wire detection block allows actively driving the output to one of the rails in case of a broken supply
or ground connection. Extensive protection of the supply lines allows the MLX90809 to handle extreme
overvoltage conditions and is immune to severe external disturbances. Several diagnostic functions (overvoltage, under-voltage, overpressure, under pressure detections) have been implemented on the 90809 and
can be enabled by programming EEPROM settings. Figure 2 describes MLX90809 block diagram.
Broken wire
detection
Test
Temperature
sensor
Piezoresistive
sensing element
OPA
Micro controller
M
U
X
ADC
16 bits
Analog driver
Gain & Offset temperature
compensation
Pressure Linearization
DAC
Analog
Output
Gain
12 bits
Programmable filter
Diagnostics Logic
Diagnostic signals
Vext
Analog & Digital
Regulator and
POR
DSP
Gain & Offset
compensation
Overvoltage &
reverse voltage
protection
Rom
FW
EE
PROM
SENT driver
Ram
Slew
rate
control
SENT
Output
Ground
Figure 2: MLX90809 block diagram
Rev 002
390109080901
Page 5 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
8 Programmed Settings
The MLX90809 is calibrated at the final manufacturing test step. During the calibration, settings are stored in
the on chip (16x32bit) EEPROM to define the pressure transfer curve as well as the output clamping levels.
Together with the transfer functions, the IC filter values are set. The default programmed filter settings lead to
the noise level and response times described in paragraph 6. The transfer functions calibrated in the different
MLX90809LXG-EAD-xxx products with its corresponding performance level maintained over the full
temperature range and over life is described for each specific option code below.
The MLX90809 can be programmed for pressure spans like those described in paragraph 6 with the
atmospheric pressure always inside of the application range.
Contact Melexis for information on the expected accuracy for other ranges or transfer functions than the
default programmed ones.
Melexis can support customers delivering parts calibrated with other settings or can support customers by
delivering the necessary programming hardware, software and documentation to be able to program the
transfer function on the customers manufacturing line. To learn how to use the Melexis hardware and
software to program the MLX90809 read the application note “MLX90809 PTC04 Software Description”.
8.1 MLX90809LXG-EAD-000
°
°
DC Operating Parameters TA = -40 C to 150 C, VDD = 5V.
Parameter
Symbol Remarks
Transfer curve: Figure 3
Pressure 1
P1
Pressure 2
P2
Output 1
O1
Output 2
O2
Parameter
Symbol Remarks
Low clamping level
LCL
High clamping level
HCL
Overall accuracy expressed as output value
Output accuracy
εo
Overall accuracy expressed as pressure value
Pressure accuracy
εp
Min
0.49
4.49
-60
-16.5
Value
0.05
-1.05
0.5
4.5
Typ
Max
0.5
0.51
4.5
4.51
60
16.5
Unit
Bar
Bar
V
V
Unit
V
V
mV
mBar
Min
0.49
4.49
-60
-15
Value
0
1
0.5
4.5
Typ
Max
0.5
0.51
4.5
4.51
60
15
Unit
Bar
Bar
V
V
Unit
V
V
mV
mBar
8.2 MLX90809LXG-EAD-003
°
°
DC Operating Parameters TA = -40 C to 150 C, VDD = 5V.
Parameter
Symbol Remarks
Transfer curve: Figure 4
Pressure 1
P1
Pressure 2
P2
Output 1
O1
Output 2
O2
Parameter
Symbol Remarks
Low clamping level
LCL
High clamping level
HCL
Overall accuracy expressed as output value
Output accuracy
εo
Overall accuracy expressed as pressure value
Pressure accuracy
εp
Rev 002
390109080901
Page 6 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
8.3 MLX90809LXG-EAD-100
°
°
DC Operating Parameters TA = -40 C to 150 C, VDD = 5V.
Parameter
Symbol Remarks
Transfer curve: Figure 3
Pressure 1
P1
Pressure 2
P2
Output 1
O1
Output 2
O2
Low clamping level
LCL
High clamping level
HCL
Parameter
Symbol Remarks
Overall accuracy expressed as output value
Output accuracy
εo
Overall accuracy expressed as pressure value
Pressure accuracy
εp
Min
-60
-20
Value
0.05
-1.20
193
3896
1
4088
Typ
Max
60
20
Unit
Bar
Bar
LSB
LSB
LSB
LSB
Unit
LSB
mBar
Output
HCL
O2
εo
εp
LCL
Relative Pressure
in Bars
O1
P2
P1
Figure 3: Transfer function negative pressure curve
Output
HCL
O2
εo
εp
LCL
Relative Pressure
in Bars
O1
P1
P2
Figure 4: Transfer function positive pressure curve
Rev 002
390109080901
Page 7 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
9 Application Information
The MLX90809 only needs 2 capacitors in the application, a 47nF decoupling capacitor on the supply line
and a 47nF load on the analog output pin. When the SENT output is used a 2.2nF capacitor is
recommended.
MLX90809 in analog mode
Vdd
47nF
Gnd
47nF
AnaOut
Figure 4: MLX90809 application schematic in analog mode
When using the analog output, Melexis recommends shorting one of the SENT output pins and the test pin to
GND.
MLX90809 in SENT mode
SENTOut
2.2nF
Vdd
47nF
Gnd
Figure 5: MLX90809 application schematic in SENT mode
When using the SENT output Melexis recommends shorting one of the analog output pins and the test pin to
GND.
Read the application note “System Integration Guidelines” for manufacturing handling as well as sealing
recommendations.
Rev 002
390109080901
Page 8 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
10 Standard information regarding manufacturability of Melexis
products with different soldering processes
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity
level according to following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)


IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)


EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)

EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)

EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak
temperature, temperature gradient, temperature profile etc) additional classification and qualification tests
have to be agreed upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of
adhesive strength between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more
information on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of
the use of certain Hazardous Substances) please visit the quality page on our website:
http://www.melexis.com/quality.aspx
11 ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
Rev 002
390109080901
Page 9 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
12 Package Information
Figure 6: MLX90809 package drawing
Table in
mm
min
max
A
2.28
2.45
A1
-0.025
0.075
A2
2.34
REF
D
10.19
10.33
D1
7.7
8.1
D2
3.7
4.1
E
7.45
7.59
E1
4.8
5.2
B
0.326
0.486
L
0.74
0.99
G1
1.5
1.7
G2
0.56
0.96
E2
1.9
2.3
A: total package thickness (body thickness + stand off)
A1: package stand off
Table in
mm
min
max
α
o
0
o
8
c
0.2
0.33
H
10.11
10.51
e
1.27
BSC
Table 5: Detailed package dimensions
Rev 002
390109080901
Page 10 of 11
Data Sheet
Oct/14
MLX90809
Relative Pressure Sensor
13 Disclaimer
Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its
Term of Sale. Melexis makes no warranty, express, statutory, implied, or by description regarding the
information set forth herein or regarding the freedom of the described devices from patent infringement.
Melexis reserves the right to change specifications and prices at any time and without notice. Therefore, prior
to designing this product into a system, it is necessary to check with Melexis for current information. This
product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical lifesupport or life-sustaining equipment are specifically not recommended without additional processing by
Melexis for each application.
The information furnished by Melexis is believed to be correct and accurate. However, Melexis shall not be
liable to recipient or any third party for any damages, including but not limited to personal injury, property
damage, loss of profits, loss of use, interrupt of business or indirect, special incidental or consequential
damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical
data herein. No obligation or liability to recipient or any third party shall arise or flow out of Melexis’ rendering
of technical or other services.
© 2014 Melexis NV. All rights reserved.
For the latest version of this document, go to our website at
www.melexis.com
Europe, Africa, Asia:
America:
Phone: +32 1367 0495
E-mail: [email protected]
Phone: +1 248 306 5400
E-mail: [email protected]
ISO/TS 16949 and ISO14001 Certified
Rev 002
390109080901
Page 11 of 11
Data Sheet
Oct/14