EPCOS B43697A5156Q000 Aluminum electrolytic capacitor Datasheet

Aluminum electrolytic capacitors
Axial-lead capacitors
Series/Type:
B43697
Date:
December 2010
© EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Axial-lead capacitors
B43697
Standard 105 °C
Applications
Electronic ballasts
Features
Long useful life
High ripple current capability
High voltage capability
550 V DC/85 °C/500 h
500 V DC/105 °C/3000 h
Very compact
Construction
Charge/discharge-proof, polar
Aluminum case with insulating sleeve
Negative pole connected to case
Axial leads, welded to ensure perfect electrical contact
Taping and packing
Bulk
Pallet package
Capacitors with d × l ≤ 16 × 30 mm are also available taped on reel.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 13
B43697
Standard 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
450 V DC
550 V DC at 85 °C
10 ... 47 µF
10/+30% Q
Leakage current Ileak
(5 min, 20 °C)
Self-inductance ESL1)
Useful life
105 °C; VR; IAC,R
105 °C; 500 V DC; IAC,R
85 °C; VR; IAC,R
70 °C; 500 V DC; IAC,R
40 °C; VR; 2.2 IAC,R
40 °C; 500 V DC;
1.6 IAC,R
Voltage endurance test
105 °C; VR
Diameter d (mm)
12
Length l (mm)
Approx. ESL (nH)
13.3
30
21
39
23
28
14
16
18
24
29
34
33
38
Requirements:
∆C/C
≤ ±30% of initial value
ESR
≤ 3 times initial specified limit
Ileak
≤ initial specified limit
> 10000 h
> 3000 h
> 50000 h
> 50000 h
> 250000 h
> 250000 h
Post test requirements:
∆C/C
≤ ±10% of initial value
ESR
≤ 1.3 times initial specified limit
Ileak
≤ initial specified limit
5000 h
Vibration resistance test
To IEC 60068-2-6, test Fc:
Frequency range 10 Hz ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its wire leads at a distance of (6 ±1) mm from
the case and additionally clamped by the case.
IEC climatic category
To IEC 60068-1:
40/105/56 (40 °C/+105 °C/56 days damp heat test)
Detail specification
Sectional specification
Similar to CECC 30301-801
IEC 60384-4
1) If optimum circuit design is used, the values are lower by 30%.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 13
B43697
Standard 105 °C
Axial-lead capacitors
Dimensional drawing
Dimensions, weights and packing units
d×l
dmax × Imax
mm
12 × 30
12 × 39
13.3 × 39
14 × 30
16 × 30
16 × 39
18 × 30
18 × 39
mm
12.5 × 30.5
12.5 × 40
14.0 × 40
14.5 × 30.5
16.5 × 30.5
16.5 × 40
18.5 × 30.5
18.5 × 40
Wire
w
mm
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
Please read Cautions and warnings and
Important notes at the end of this document.
Approx.
weight
g
5.1
6.5
8.0
6.8
8.9
11.7
11.1
14.7
Page 4 of 13
Packing units (pcs.)
Bulk
600
500
400
400
350
300
300
250
Pallet
288
288
200
200
180
180
160
160
Reel
450
350
250
B43697
Standard 105 °C
Case dimensions and ordering codes
VR
V DC
450
CR
100 Hz
20 °C
µF
10
15
15 ∇
22
22 ∇
33
33 ∇
47
Case
dimensions
d×l
mm
12 × 30
12 × 39
14 × 30
13.3 × 39
16 × 30
16 × 39
18 × 30
18 × 39
Ordering code
Bulk
Ordering code
Pallet package
Ordering code
Reel
B43697A5106Q000
B43697B5156Q000
B43697A5156Q000
B43697B5226Q000
B43697A5226Q000
B43697B5336Q000
B43697A5336Q000
B43697A5476Q000
B43697A5106Q007 B43697A5106Q009
B43697B5156Q007
B43697A5156Q007 B43697A5156Q009
B43697B5226Q007
B43697A5226Q007 B43697A5226Q009
B43697B5336Q007
B43697A5336Q007
B43697A5476Q007
∇ Variant with different case dimensions
Technical data
CR
100 Hz
20 °C
µF
ESRtyp
100 Hz
20 °C
Ω
VR = 450 V DC
10
7.5
15
4.8
15 ∇
4.8
22
3.2
22 ∇
3.2
33
2.1
33 ∇
2.1
47
1.5
ESRmax
100 Hz
20 °C
Ω
ESRmax
100 Hz
25 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,max
10 kHz
60 °C
A
IAC,max
10 kHz
85 °C
A
IAC,R
10 kHz
105 °C
A
11.0
7.6
7.6
5.2
5.2
3.5
3.5
2.6
300
170
170
120
120
95
95
70
4.4
3.0
3.0
2.0
2.0
1.4
1.4
1.0
4.3
2.9
2.9
1.9
1.9
1.3
1.3
0.9
1.13
1.51
1.48
1.98
1.91
2.68
2.44
3.31
0.92
1.24
1.21
1.62
1.56
2.19
1.99
2.70
0.48
0.65
0.64
0.85
0.82
1.15
1.05
1.42
∇ Variant with different case dimensions
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 13
B43697
Standard 105 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions at VR1)
VR = 450 V
Useful life
depending on ambient temperature TA under ripple current operating conditions at Vop1)
Vop = 500 V
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 13
B43697
Standard 105 °C
Frequency factor of permissible ripple
current IAC versus frequency f
Frequency characteristics of ESR
Typical behavior
Equivalent series resistance ESR
versus frequency f
Typical behavior for 10 µF/450 V
Impedance Z
versus frequency f
Typical behavior for 10 µF/450 V
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 13
B43697
Standard 105 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 13
B43697
Standard 105 °C
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not exceed the upper category temperature.
Upper category
temperature
Maintenance
Mounting
position of screwterminal capacitors
Mounting of
single-ended
capacitors
Robustness of
terminals
Soldering
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Reference
chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
7.2
"Maximum permissible
operating temperature"
10
"Maintenance"
11.1.
"Mounting positions of
capacitors with screw
terminals"
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2 Nm
M6: 2.5 Nm
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 13
B43697
Standard 105 °C
Topic
Soldering,
cleaning agents
Passive
flammability
Active
flammability
Safety information
Reference
chapter "General
technical information"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Avoid external energy, such as fire or electricity.
8.1
"Passive flammability"
Avoid overload of the capacitors.
8.2
"Active flammability"
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 13
Reference
chapter "Capacitors with
screw terminals"
"Screw terminals accessories"
B43697
Standard 105 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Rated ripple current for base cooling
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,rms
IAC,f
IAC,max
IAC,R
IAC,R (B)
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Nennwechselstromstrom für Bodenkühlung
Reststrom
Betriebsreststrom
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Becherbodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 11 of 13
B43697
Standard 105 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Note
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 13
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Page 13 of 13
Similar pages