MPD MH648D-05RU Wide 4:1 input ultra-miniature, 6w dc/dc converter Datasheet

MH600RU Series
Wide 4:1 Input
Ultra-Miniature, 6W
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 6W Output Power
Input
Parameter
Conditions
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Range
• Miniature 0.80 x 0.85” Case
• Wide 4:1 Input Range
• Single & Dual Outputs
Input Start Voltage
Under Voltage Shutdown
• 1,500 VDC Isolation
• >350 kHour MTBF
Short Circuit Input Power
Input Filter
• -40°C to +80°C Operation
Output
• 16 Standard Models
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Transient Recovery Time
Transient Response Deviation
Overload Protection
Output Short Circuit
Min.
9.0
18.0
Typ.
24.0
48.0
Max.
36.0
75.0
9.0
18.0
8.5
17.0
3.0
Units
Max.
±2.0
Units
%
%
%
%
mV P - P
%/°C
µSec
%
%
VDC
VDC
VDC
W
Internal Capacitor
Conditions
Min.
Typ.
±1.0
Dual Output, Balanced Loads
±1.0
±0.5
VIN = MIN to MAX
IOUT = 15% to 100%
±0.5
See Note 2
60
±0.01
300
See Note 3
±3.0
See Note 4
110
150
Continuous (Autorecovery)
±1.0
±1.2
100
±0.02
600
General
Parameter
Conditions
60 Seconds
1 Second
500 VDC
100 kHz, 1.0V
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Conducted Emissions
Standard
Min.
1,500
1,800
1,000
Typ.
Max.
Units
VDC
1,200
330
1,500
Criterea
M
pF
kHz
Level
Class A
EN 55022
Environmental
Parameter
Conditions
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Ambient
Case
Min.
-40
Typ.
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+105
+125
Units
95
%
°C
°C
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL-94V0)
0.32 Oz (9.1g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
350
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MH624S-03RU
MH624S-05RU
MH624S-12RU
MH624S-15RU
MH624S-24RU
MH624D-05RU
MH624D-12RU
MH624D-15RU
MH648S-03RU
MH648S-05RU
MH648S-12RU
MH648S-15RU
MH648S-24RU
MH648D-05RU
MH648D-12RU
MH648D-15RU
Voltage (VDC)
Nominal
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
Output
Current (mA)
Voltage
Range
Full-Load No-Load (VDC)
9.0 - 36.0
262
30
3.3
9.0 - 36.0
316
30
5.0
9.0 - 36.0
301
30
12.0
9.0 - 36.0
301
30
15.0
9.0 - 36.0
301
30
24.0
9.0 - 36.0
301
30
±5.0
9.0 - 36.0
301
30
±12.0
9.0 - 36.0
301
30
±15.0
18.0 - 75.0
131
20
3.3
18.0 - 75.0
158
20
5.0
18.0 - 75.0
151
20
12.0
18.0 - 75.0
151
20
15.0
18.0 - 75.0
151
20
24.0
18.0 - 75.0
151
20
±5.0
18.0 - 75.0
151
20
±12.0
18.0 - 75.0
151
10
±15.0
Notes:
1. The specified maximum capacitive load is for each output.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic
capacitor is connected from the +VOUT to the -VOUT pins. If the application is noise sensitive;
connecting a low ESR 3.3 µF capcitor should be used. This capacitor should be mounted
as close to the converter as possible.
3. Transient recovery is measured to within a 1% error band for a load step change
of 25%.
4. Output overload protection is provided by a fold back current limiting circuit with
auto-recovery. A long-term overload could damage the unit.
5. Operation at no load will not damage these units.
6. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Current
Current
(mA, Max)
(mA, Min)
1,450.0
1200.0
500.0
400.0
250.0
±600.0
±250.0
±200.0
1,450.0
1200.0
500.0
400.0
250.0
±600.0
±250.0
±200.0
218.0
180.0
75.0
60.0
38.0
±90.0
±38.0
±30.0
218.0
180.0
75.0
60.0
38.0
±90.0
±38.0
±30.0
Capacitive Efficiency Fuse Rating
Load
Slow-Blow
(%, Typ)
(µF Max)
(mA)
330
330
100
100
100
100
100
100
330
330
100
100
100
100
100
100
76
79
83
83
83
82
83
83
76
79
83
83
83
82
83
83
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
750
750
750
750
750
750
750
750
Remote On/Off
Parameter
Conditions
Unit On
Min.
Typ.
Max.
Units
2.5 VDC - 50.0 VDC or Open Circuit
Unit Off
0.7 VDC - 0.8 VDC or Short Circuit
Control Input Current, ON
VCTRL = 5V
500
µA
Control Input Current, OFF
VCTRL = 0V
-500
µA
Control Common
Referenced to -VIN (Pin 2)
Standby Input Current
10.0
mA
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
1 Remote On/Off
2
-VIN
6 No Connection
8 No Connection
9
+VOUT
11
-VOUT
16
+VIN
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
• Pin 1 is marked by a “dot” or indentation on the unit
Pin
Dual
1 Remote On/Off
2
-VIN
6
Common
8
-VOUT
9
+VOUT
11
Common
16
+VIN
MicroPower Direct