LPF3513 Series http://www.abco.co.kr SMD Shielded type ▼Shape & Dimensions / Recommended Solder Land Pattern (Dimensions in mm) 1.3±0.1 3.8 1.2 3.5±0.2 1.2 3.5±0.2 3.8 1.7 1.7 ▼Electrical Characteristics Ordering Code Inductance L Tol. (uH) (%) Frequency F (KHz) DC Resistance(Ω) Rated DC current(A) ±30 Rdc (Max.) Idc1 ( Max.) Idc2 ( Typ.) LPF3513T-1R0N 1.0 0.052 2.000 2.000 LPF3513T-1R5M 1.5 0.058 1.600 1.750 LPF3513T-2R2M 2.2 0.078 1.300 1.550 LPF3513T-3R3M 3.3 0.114 1.100 1.400 LPF3513T-4R7M 4.7 0.1565 0.800 1.200 LPF3513T-6R8M 6.8 0.2245 0.780 0.950 LPF3513T-100M 10 0.292 0.740 0.840 LPF3513T-150M 15 0.425 0.550 0.670 LPF3513T-220M 22 0.635 0.450 0.540 LPF3513T-330M 33 1.0 0.380 0.410 LPF3513T-470M 47 1.265 0.280 0.310 LPF3513T-680M 68 1.58 0.250 0.300 LPF3513T-101M 100 2.47 0.200 0.220 LPF3513T-151M 150 3.87 0.140 0.195 LPF3513T-221M 220 4.65 0.130 0.190 LPF3513T-331M 330 8.65 0.095 0.140 LPF3513T-471M 470 11.90 0.080 0.090 LPF3513T-561M 560 13.45 0.075 0.075 LPF3513T-681M 680 18.0 0.070 0.070 ±20 100 LPF3513T-821M 820 20.85 0.060 0.065 LPF3513T-102M 1000 22.45 0.050 0.060 LPF3513T-152M 1500 35.0 0.045 0.050 LPF3513T-222M 2200 58.0 0.040 0.040 ▼ Test Equipments □ Packing style . L : Agilent E4980A Precision LCR Meter . Rdc : HIOKI 3540 mΩ HiTESTER . Idc1 : Agilent 4284A LCR Meter + Agilent 42841A Bias Current Source . Idc2 : Yokogawa DR130 Hybrid Recorder + Agilent 6692A DC Power Supply T : Taping ▼ Test Condition . L(Frequency , Voltage) : F=100 (KHz) , V=0.5 (V) . Idc1(The saturation current) : △L≤ 30% reduction from nominal L value . Idc2(The temperature rise): △T= 30℃ typical at rated DC current ※ Rated DC current(Idc) : The value of Idc1 or Idc2 , whichever is smaller ▼ Operating Temperature Range -20 ~ +70℃ (Including self-generated heat) B : Bulk