MPD MB1524S05ERW Mb1500erw Datasheet

MB1500ERW
Low Cost, 1 x 2 Inch
15W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 15W Output Power
Input
Parameter
• 2:1 Input Voltage Range
Input Voltage Range
• 1,500 VDC Isolation
• Single & Dual Outputs
Input Start Voltage
• Efficiency to 90%
• Compact 1 x 2 Inch Case
Under Voltage Shutdown
• -40°C to +85°C Operation
• Industry Standard Pin-Out
Input Filter
Start-Up Time
• Low Cost
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Output Trim Range
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit, See Note 4
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
12 VDC Input
7.5
24 VDC Input 16.0
48 VDC Input 32.0
(Pi) Filter
See Note 1
Typ.
12.0
24.0
48.0
Conditions
Typ.
±1.0
±0.5
±10
±0.2
±0.5
Min.
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 10% to 100%
See Note 2
See Note 3
Max.
18.0
36.0
75.0
9.0
17.8
35.8
Units
VDC
VDC
VDC
10
70
150
±0.02
Continuous (Autorecovery)
mS
Max.
±3.0
±1.0
±0.5
±1.0
±5.0
100
Units
%
%
%
%
%
mV P - P
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
See Note 5
Min.
1,500
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
1,000
300
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
Remote On/Off
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
2.0 x 1.0 x 0.465 Inches (50.8 x 25.4 x 11.8 mm)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.99 Oz (28g)
Conditions
See Note 6
See Note 6
Min.
2.5
0
Typ.
Max.
12.0
1.2
Units
VDC
VDC
mA
1.0
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
MB1512S-03ERW
MB1512S-05ERW
MB1512S-12ERW
MB1512S-15ERW
MB1512S-24ERW
MB1512D-05ERW
MB1512D-12ERW
MB1512D-15ERW
MB1512D-24ERW
MB1524S-03ERW
MB1524S-05ERW
MB1524S-12ERW
MB1524S-15ERW
MB1524S-24ERW
MB1524D-05ERW
MB1524D-12ERW
MB1524D-15ERW
MB1524D-24ERW
MB1548S-03ERW
MB1548S-05ERW
MB1548S-12ERW
MB1548S-15ERW
MB1548S-24ERW
MB1548D-05ERW
MB1548D-12ERW
MB1548D-15ERW
MB1548D-24ERW
Input
Output
Current (mA)
Voltage (VDC)
Nominal
Range
Full-Load No-Load
12
9.0 - 18.0
1,465
65
12
9.0 - 18.0
1,405
60
12
9.0 - 18.0
1,405
25
12
9.0 - 18.0
1,405
25
12
9.0 - 18.0
1,389
30
12
9.0 - 18.0
1,453
30
12
9.0 - 18.0
1,420
25
12
9.0 - 18.0
1,420
25
12
9.0 - 18.0
1,420
20
24
18.0 - 36.0
625
35
24
18.0 - 36.0
695
35
24
18.0 - 36.0
703
20
24
18.0 - 36.0
695
20
24
18.0 - 36.0
695
25
24
18.0 - 36.0
727
25
24
18.0 - 36.0
710
20
24
18.0 - 36.0
710
20
24
18.0 - 36.0
710
20
48
36.0 - 75.0
316
35
48
36.0 - 75.0
360
35
48
36.0 - 75.0
352
25
48
36.0 - 75.0
348
15
48
36.0 - 75.0
352
15
48
36.0 - 75.0
363
20
48
36.0 - 75.0
355
15
48
36.0 - 75.0
355
15
48
36.0 - 75.0
355
15
Voltage Current
Current
(VDC) (mA, Max) (mA, Min)
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
Notes:
1. Start up time is measured at nominal input and with a constant resistive load.
2. Cross regulation is measured with the output being tested at 50% load. The second output is varied
from 10% to 100% load.
3. When measuring output ripple, it is recommended that an external ceramic capacitor (approx
1 µF to 10 µF) be placed from the +VOUT to the -VOUT pins.
4. Short circuit protection is provided by a “hiccup mode” circuit.
5. Isolation capacitance for 24 VDC output models is 2,000 pF. Isolation capacitance is measured from
input to output at 100 kHz/0.1V.
6. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum
control current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/off pin is left open, the
unit operates. If it is grounded, the unit will shut off.
7. These units should not be operated with a load under 10% of full load. Operation at no-load will not
damage the unit, but they may not meet all specifications.
8. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
200
150
63
50
32
±75
±32
±25
±16
200
150
63
50
32
±75
±32
±25
±16
200
150
63
50
32
±75
±32
±25
±16
Fuse
Over
Capacitive
Rating
Efficiency Voltage
Load
(%, Typ) Protection (µF, Max) Slow-Blow
(VDC Typ)
(mA)
87
3.9
10,500
3,000
89
6.2
4,020
3,000
89
15.0
1,035
3,000
89
18.0
705
3,000
90
30.0
250
3,000
86
±6.2
±1,020
3,000
88
±15.0
±495
3,000
88
±18.0
±165
3,000
88
±30.0
±200
3,000
88
3.9
10,500
1,500
90
6.2
4,020
1,500
89
15.0
1,035
1,500
90
18.0
705
1,500
90
30.0
250
1,500
86
±6.2
±1,020
1,500
88
±15.0
±495
1,500
88
±18.0
±165
1,500
88
±30.0
±200
1,500
87
3.9
10,500
1,000
87
6.2
4,020
1,000
89
15.0
1,035
1,000
90
18.0
705
1,000
89
30.0
250
1,000
86
±6.2
±1,020
1,000
88
±15.0
±495
1,000
88
±18.0
±165
1,000
88
±30.0
±200
1,000
Derating Curve Output Over 5VDC
External Trim
Derating Curve Output 5VDC & 3.3VDC
On single output units, a simple external circuit may be used to adjust the converter output.
To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and
the Vout trim pin. To adjust the output UP, connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin.
For UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm
connected to the Vout trim pin.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Standard
See Note 1
EN 55022
See Note 1
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 2
EN 61000-4-4
See Note 3
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Notes:
1. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet class B with the addition of the DCFM-0x (or a similar discrete
filter circuit). Contact the factory for more information.
2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the DCFM-0x.
Contact the factory for more information.
3. To meet the requirements of EN 61000-4-5 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the DCFM-0x. Contact
the factory for more information.
Typical Connection
For pricing or full technical information on these modules (DCFM-01,
The diagram above illustrates a typical connection of the MB1500ERW 5. Recommended values for components are:
DCFM-02 and DCFM-03) please contact the factory.
series for applications that require meeting EMC standards. The units do not Component
24 VIN
48 VIN
12 VIN
7. In many applications simply
require external components to operate as specified. Some notes on this
Vin
Input
Vout
Output
MOV
10D560
10D101
adding input/output capacidiagram (starting with the input circuit) are:
(VDC) Capacitor (VDC) Capacitor
L1
56 µH
56 µH
tors will enhance the input
1. It is recommended that an external fuse be used. The recommended fuse
3.3
470 µF
surge protection and reduce
is shown in the model chart on page 2.
TVS
SMCJ28A
SMCJ48A
SMCJ90A
12
100 µF
5
470 µF
output ripple sufficiently. The
2. An external MOV is recommended on the input to protect the unit in the
C1
680 µF/25V
120 µF/25V
120 µF/100V
input capacitor C1 and output
event of a surge. A recommended value is given in the table at right.
12
220 µF
C2
1.0 µF/50V
1.0 µF/50V
1.0 µF/100V
24
100
µF
capacitors C5 and C6 shown
3. An external TVS is recommended on the input to protect the unit in the
15
220 µF
L2
4.7 µH
4.7 µH
4.7 µH
in the typical connection diaevent of a voltage spike. A recommended value is given in the table at
24
100 µF
100 µF
C3, C4
1,000 pF/2 kV 1,000 pF/2 kV 1,000 pF/2 kV
gram above, and board layout 48
right.
±5
±220 µF
drawing below illustrate their
4. The output filtering capacitor (C5) is a high frequency, low resistance
±100 µF
connection in this case, recommended capacitor ±12
electrolytic capacitor. Care must be taken in choosing this capacitor not 6. Input noise and surge suppression modules are available for
±15
±100 µF
a number of MPD DC/DC power supplies. An MB1500ERW
values are given in the table at right.
to exceed the capacitive load specification for the unit. The board layout
connection with the DCFM-03 (surge suppression) module
±24
±47 µF
illustration below shows a connection for dual output units. Voltage derating
connected to the input and the DCFM-03 EMS module.
of capacitors should be 80% or above.
Typical Board Layout: With External Filter/Surge Components for Dual Output Unit
Typical Connection: With DCFM-0x ISurge Suppression and Filter Modules
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Mechanical Dimensions: With Optional Heatsink
Pin
1
2
3
4
5
6
Single Output
+Vin
-Vin
+Vout
Trim
-Vout
Remote On/Off
Pin
1
2
3
4
5
6
Dual Output
+Vin
-Vin
+Vout
Common
-Vout
Remote On/Off
For the heatsink option, add suffix “H” to the
model number (i.e. MB1524S-05ERW-H)
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages