Hittite HMC600LP4E 75 db logarithmic detector / controller 50 - 4000 mhz Datasheet

HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Typical Applications
Features
The HMC600LP4 / HMC600LP4E is ideal for IF and
RF applications in:
Wide Dynamic Range: up to 75 dB
• Cellular/PCS/3G
Power-Down Mode
• WiMAX, WiBro & Fixed Wireless
Excellent Stability over Temperature
• Power Monitoring & Control Circuitry
Compact 4x4mm Leadless SMT Package
Flexible Supply Voltage: +2.7V to +5.5V
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control
General Description
Functional Diagram
The HMC600LP4 & HMC600LP4E Logarithmic
Detector/Controller convert RF signals at its input, to a
proportional DC voltage at its output. The HMC600LP4
& HMC600LP4E employ a successive compression
topology which delivers extremely high dynamic range
and conversion accuracy over a wide input frequency
range. As the input power is increased, successive
amplifiers move into saturation one by one creating an
accurate approximation of the logarithm function. The
output of a series of square law detectors is summed,
converted into voltage domain and buffered to drive the
LOGOUT output. For detection mode, the LOGOUT pin
is shorted to the VSET input, and will provide a nominal
logarithmic slope of 19mV/dB and an intercept of -95
dBm. The HMC600LP4 & HMC600LP4E can also be
used in the controller mode where an external voltage
is applied to the VSET pin, to create an AGC or APC
feedback loop.
POWER DETECTORS - SMT
10
Electrical Specifications, TA = +25C, PWD = 0V, Vcc1, Vcc2 = +3.3V [1]
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Units
Input Frequency
Parameter
50
100
500
900
1900
2500
3500
4000
MHz
±3 dB Dynamic Range
74
74
74
74
70
66
51
48
dB
±3 dB Dynamic Range Center
-30
-30
-30
-30.5
-31.0
-31.0
-27
-23.5
dBm
±1 dB Dynamic Range
64
64
64
65
62
59
44
41
dB
19.6
19.5
19.4
19.2
19.1
19.5
21.0
22.3
mV/dB
Output Slope
Output Intercept
-96
-96
-96
-96
-95
-93
-79
-72
dBm
Temperature Sensitivity @ -10 dBm Input [2]
-2.7
-2.8
-3.6
-4.8
-6.9
-7.4
-8.3
-12.9
mdB/°C
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 16).
[2] Measured from TA = -40C to TA = +85C
10 - 2
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Electrical Specifications, (continued)
Parameter
Conditions
Min.
Typ.
Max.
Units
RF Input (INP)
Return Loss
F = 50 - 4000 MHz, Zo = 50Ω, See plot
10
dB
16
kΩ
LOGOUT Interface
Current Drive (Source)
Current Drive (Sink)
For 1% change in the output voltage
Output Voltage Range
0.4
mA
2.25
mA
0
Small Signal Response Time (10% to 90%)
Large Signal Response Time
(±0.5 dB Settling)
Output Rise Time
Ripple
Vcc -0.13
V
Pin = -60 to -57 dBm
50
ns
Pin = No Signal to 0 dBm
150
ns
From 0% to 90%
90
ns
Fin = 100 MHz
<2
mVpp
30
kΩ
VSET Interface
Input Impedance
Input Voltage Range
Low Frequency Gain
VSET to LOGOUT
Open Loop Corner Frequency
0.6 to 1.9
V
78
dB
1.6
kHz
Power Down (PWD) Interface
Voltage Range for Normal Mode
Voltage Range for Shutdown Mode
0
0.2 x Vcc
0.8 x Vcc
Vcc
Threshold Voltage
Power-up Response Time
Vcc/2
V
V
V
50% PWD to ±0.5 dB Settling of LOGOUT
3.8
μs
50% PWD to 10% Icc
6.6
μs
Power-Down Response Time
Power Supply (Vcc1, Vcc2)
Operating Voltage Range
2.7
Supply Current in Normal Mode
Vcc = +3.3V, PWD = 0V
29
Supply Current in Power Down Mode
Vcc = +3.3V, PWD = Vcc
1
5.5
V
36
mA
Test Conditions
Parameter
Condition
Vcc1, Vcc2
+3.3V
Input Zo
50Ω
TA
+25C
Fin
900 MHz
mA
10
POWER DETECTORS - SMT
Open Loop Impedance
INN Port connected to ground through a 1000pF capacitor
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
10 - 3
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 50 MHz
5
2
4
1.8
3
1.6
2
1.4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
1
1
0
0.8
-1
0.6
0
0.8
0.4
0.2
-4
0.2
0
-5
0
-60
-50
-40
-30
-20
-10
0
-1
-2
-70
-60
-50
3
1.6
1.4
2
1.4
1.2
1
1
0
LOGOUT (V)
LOGOUT (V)
1.8
0.6
-3
0.4
-4
0.2
-5
0
ERR +25 C
ERR +85 C
ERR -40 C
0
-40
-30
-20
-10
0
5
-60
2
4
1.8
3
1.6
2
1.4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
LOGOUT (V)
1
0
0.6
-3
0.4
-4
0.2
-5
0
ERR +25 C
ERR +85 C
ERR -40 C
-20
-10
0
INPUT POWER (dBm)
-5
5
4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
3
2
0.8
-1
-2
-3
ERR +25 C
ERR +85 C
ERR -40 C
-70
-60
-50
-40
-30
-20
-10
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
10 - 4
0
0
-2
-30
-10
1
0.6
-40
-20
1
-1
-50
-30
1.2
0.8
-60
-40
-4
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
-4
0
-5
ERROR (dB)
1
ERROR (dB)
1.2
LOGOUT (V)
5
0
-70
-50
-3
LOGOUT Voltage & Error
vs. Input Power, Fin = 2500 MHz
2
0.2
-2
ERR +25 C
ERR +85 C
ERR -40 C
INPUT POWER (dBm)
1.8
0.4
2
-1
-70
LOGOUT Voltage & Error
vs. Input Power, Fin = 1900 MHz
1.4
3
0.8
INPUT POWER (dBm)
1.6
4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
0
-2
-50
-5
1
0.6
-60
0
1
-1
-70
-10
1.2
0.8
0.2
-20
ERROR (dB)
2
4
ERROR (dB)
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
0.4
-30
LOGOUT Voltage & Error
vs. Input Power, Fin = 900 MHz
2
1.6
-40
-4
INPUT POWER (dBm)
LOGOUT Voltage & Error
vs. Input Power, Fin = 500 MHz
1.8
-3
ERR +25 C
ERR +85 C
ERR -40 C
INPUT POWER (dBm)
10
2
1
-3
-70
3
1
0.6
0.4
4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
1.2
-2
ERR +25 C
ERR +85 C
ERR -40 C
5
ERROR (dB)
1.2
ERROR (dB)
LOGOUT (V)
1.4
LOGOUT (V)
2
1.8
1.6
POWER DETECTORS - SMT
LOGOUT Voltage & Error
vs. Input Power, Fin = 100 MHz
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 4000 MHz
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
1.6
2
4
1.8
3
1.6
2
1.4
1
1
0
0
-2
0.6
-3
0.4
-4
0.2
-5
0
0
-60
-50
-40
-30
-20
-10
0
0.8
-1
-2
-60
-50
24
24
+25 C
+85 C
-40 C
SLOPE (mV/dB)
SLOPE (mV/dB)
25
21
19
18
2000
2500
3000
3500
18
2.5
4000
3
3.5
FREQUENCY (MHz)
10
4
4.5
5
5.5
LOGOUT Intercept vs. Bias Voltage
TA = +25C
-50
-50
-60
-60
INTERCEPT (dBm)
INTERCEPT (dBm)
-5
Vcc (V)
LOGOUT Intercept vs. Frequency,
Vcc = +3.3V
+25 C
+85 C
-40 C
-70
0
21
19
1500
-10
22
20
1000
-20
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
23
20
500
-30
LOGOUT Slope vs. Supply Voltage,
TA = +25C
25
0
-40
-4
INPUT POWER (dBm)
LOGOUT Slope vs. Frequency,
Vcc = 3.3V
22
-3
ERR +25 C
ERR +85 C
ERR -40 C
INPUT POWER (dBm)
23
2
1
0.6
0.2
3
1
-1
ERR +25 C
ERR +85 C
ERR -40 C
4
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
1.2
0.8
0.4
5
-80
-90
ERROR (dB)
1.2
ERROR (dB)
LOGOUT (V)
1.4
5
LOGOUT (V)
2
1.8
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
POWER DETECTORS - SMT
LOGOUT Voltage & Error
vs. Input Power, Fin = 3500 MHz
-70
-80
-90
-100
0
500
1000
1500
2000
2500
3000
3500
4000
FREQUENCY (MHz)
-100
2.5
3
3.5
4
4.5
5
5.5
Vcc (V)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
10 - 5
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Error vs. Input Power,
Normalized[2], Fin = 1900 MHz
Input Return Loss
0
2.5
INPUT RETURN LOSS (dB)
NORMALIZED ERROR (dB)
2
+85 C
-40 C
1.5
1
0.5
0
-0.5
-1
-15
-20
+25 C
+85 C
-40 C
-25
-35
-60
-50
-40
-30
-20
-10
0
0
1
INPUT POWER (dBm)
10
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
1.6
1.4
1.2
1
0.8
0.6
0.4
-75
-65
-55
-45
-35
-25
INPUT POWER (dBm)
3
4
-15
-5
5
Vcc1, Vcc2
0V to +5.5V
PWD
0V to +5.5V
VSET Input Voltage
0V to +5.5V
LOGOUT Output Current
3 mA
RF Input Power
+12 dBm
Junction Temperature
125 °C
Continuous Pdiss (T = 85°C)
(Derate 7.95 mW/°C above 85°C)
0.32 Watts
Thermal Resistance (Rth)
(junction to lead)
126 °C/W
Storage Temperature
-65 to +150 °C
Operating Temperature
-40 to +85 °C
ESD Sensitivity (HBM)
Class 1C
ELECTROSTATIC SENSITIVE DEVICE
OBSERVE HANDLING PRECAUTIONS
[1] Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
[2] This data is relative to the room temperature performance of the HMC600LP4
10 - 6
5
Absolute Maximum Ratings
2
1.8
2
FREQUENCY (GHz)
LOGOUT Voltage vs. Input Power and
Frequency, TA = +25C
LOGOUT (V)
POWER DETECTORS - SMT
-10
-30
-1.5
-2
-70
-5
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Outline Drawing
NOTES:
1. LEADFRAME MATERIAL: COPPER ALLOY
2. DIMENSIONS ARE IN INCHES [MILLIMETERS].
3. LEAD SPACING TOLERANCE IS NON-CUMULATIVE
4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM.
PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM.
5. PACKAGE WARP SHALL NOT EXCEED 0.05mm.
6. ALL GROUND LEADS AND GROUND PADDLE MUST
BE SOLDERED TO PCB RF GROUND.
7. REFER TO HITTITE APPLICATION NOTE FOR SUGGESTED
PCB LAND PATTERN.
Package Information
Part Number
Package Body Material
Lead Finish
MSL Rating
HMC600LP4
Low Stress Injection Molded Plastic
Sn/Pb Solder
MSL1
HMC600LP4E
RoHS-compliant Low Stress Injection Molded Plastic
100% matte Sn
MSL1
Package Marking [3]
[1]
H600
XXXX
[2]
H600
XXXX
POWER DETECTORS - SMT
10
[1] Max peak reflow temperature of 235 °C
[2] Max peak reflow temperature of 260 °C
[3] 4-Digit lot number XXXX
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
10 - 7
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Pin Descriptions
Pin Number
Function
Description
1, 6, 7-13,
15, 18-24
N/C
These pins are not connected internally; however,
this product is specified with these pins connected
to RF/DC ground.
2, 6
Vcc1, Vcc2
Bias supply. Connect supply voltage to both pins.
3, 4
INP, INN
RF Input pins. Connect RF to INP, and AC couple
INN to ground for single-ended operation.
14
PWD
Connect to 0V for normal operation. Applying voltage
>0.8 x Vcc will initiate a power saving shutdown mode.
16
VSET
VSET input in controller mode. Short this
pin to LOGOUT for detector mode.
17
LOGOUT
Logarithmic output that converts the input power
to a DC level in detector mode. Short this pin to
VSET for detector mode.
Package
Base
GND
Exposed paddle must be connected to RF and DC ground.
Interface Schematic
POWER DETECTORS - SMT
10
10 - 8
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Evaluation PCB
List of Materials for Evaluation PCB 115242 [1]
Item
Description
J1 - J4
PC Mount SMA Connector
J5 - J8
DC Pin
C1, C2
1000 pF Capacitor, 0402 Pkg.
C3, C4
0.1μF Capacitor, 0402 Pkg.
R1, R2
5.6Ω Resistor, 0603 Pkg.
R3-R5
0Ω Resistor, 0603 Pkg.
U1
HMC600LP4 / HMC600LP4E
Logarithmic Detector / Controller
PCB [2]
115244 Eval Board
The circuit board used in the final application should
use RF circuit design techniques. Signal lines
should have 50 ohm impedance while the package
ground leads and exposed paddle should be connected directly to the ground plane similar to that
shown. A sufficient number of via holes should be
used to connect the top and bottom ground planes.
The evaluation circuit board shown is available from
Hittite upon request.
POWER DETECTORS - SMT
10
[1] Reference this number when ordering complete evaluation PCB
[2] Circuit Board Material: Rogers 4350
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
10 - 9
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Application & Evaluation PCB Schematic
POWER DETECTORS - SMT
10
10 - 10
Notes
Note 1: The HMC600LP4 & HMC600LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode.
Note 2: For single-ended input operation, use the INP port and make no connection to INN. INN is AC coupled to ground by C2
Note 3: For differential input, remove C2, and install a 1000pF capacitor in series with INN at location shown.
Note 4: For detector mode, connect high impedence volt meter to the LOGOUT port, and make no connection to VSET. LOGOUT
is shorted to VSET by R3, as required for detector mode.
Note 5: For controller mode, remove R3 and make appropriate connection to LOGOUT and VSET. In controller mode, the
LOGOUT output can be used to drive a variable gain amplifier, or a variable attenuator, either directly or through a buffer
or microcontroller. VSET should be connected to an external supply, typically between +0.6 and +1.9V.
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
HMC600LP4 / 600LP4E
v01.0606
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Notes:
POWER DETECTORS - SMT
10
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
10 - 11