AC-DC 30-60 Watts AFM Series xppower.com • Energy Efficiency Level V • CEC2008 & EISA2007 Compliant • IT & Medical Approvals • China Compulsory Certification (CCC) Qualified • Optional Class II Versions • Optional White Case Versions • 3 Year Warranty Specification Input General • 80-264 VAC, derate output power 25% <90 VAC Input Frequency • 47-63 Hz Input Current • AFM30: 0.8 A rms at 115VAC, AFM45: 1.2 A rms at 115VAC, AFM60: 1.5 A rms at 115 VAC Inrush Current • AFM30: 50 A max at 240VAC, AFM45: 50 A max at 240VAC, AFM60: 120 A max at 240VAC Power Factor • EN61000-3-2, class A Earth Leakage Current • 150 µA max at 264 VAC/60 Hz No Load Input Power • AFM30/45: <0.3 W, AFM60: <0.5 W Input Voltage Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature • Coefficient See table Not user-adjustable ±2% No minimum load required 3 s max at 115 VAC 8 ms minimum at 115 VAC ±1.0% maximum 2.5% maximum 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change 1% max pk-pk (1) 110-170% Vnom, recycle input to reset AFM45/60: 110-170%, AFM30: 110-220%, auto recovery Trip and restart (hiccup mode) 0.04%/°C Efficiency Energy Efficiency Isolation Switching Frequency Power Density MTBF • See table • Level V • 4000 VAC Input to Output, 2 x MOPP 1500 VAC Input to Ground, 1 x MOPP* Output 0 V is electrically connected to Input Ground*. *Not C8 version. • 30/45 W: 58 kHz typ., 60 W: 52 kHz typ. • AFM30: 2.8 W/In3, AFM45: 4.2 W/In3, AFM60: 3.76 W/In3 • >250 kHrs to MIL-HDBK-217F at 25 °C, GB, full load Environmental Operating Temperature • 0 °C to +60 °C, derate from 100% power at +40 °C to 60% power at +60 °C Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -40 °C to +80 °C Operating Altitude • 2000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55011/22/FCC Class B conducted, EN55011/22/FCC Class B radiated • EN61000-3-2, Class A • EN61000-3-3 • EN61000-4-2, 6 kV contact and 8 kV air discharge • EN61000-4-3, 3 V/m Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A (7) • EN61000-4-5, installation class 3 Perf Criteria A • EN61000-4-6, 3 Vrms Perf Criteria A • EN61000-4-8, 3 A/m, Perf Criteria A • EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf A, A, A, B (8) • EN60950-1, UL60950-1, IEC60950-1 EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.), IEC60601-1 (3rd Ed.) China Compulsory Certification (CCC) Qualified. Output Power Output Voltage(6) 30 W 30 W 30 W 30 W 48 W 48 W 48 W 48 W 60 W 60 W 60 W 60 W 12 V 15 V 18 V 24 V 12 V 15 V 18 V 24 V 12 V 15 V 18 V 24 V Output Current 2.50 2.00 1.67 1.25 4.00 3.20 2.67 2.00 5.00 4.00 3.34 2.50 Efficiency(7) Model Number(3,4,5) 87.9% 88.4% 87.6% 88.0% 87.7% 88.0% 87.2% 87.7% 87.3% 88.2% 88.3% 87.8% AFM30US12 AFM30US15 AFM30US18 AFM30US24 AFM45US12 AFM45US15 AFM45US18 AFM45US24 AFM60US12 AFM60US15 AFM60US18 AFM60US24 A A A A A A A A A A A A Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix ‘C2’ to the model number, e.g. AFM60US24C2. 4. For alternative IEC320-C6 inlet, add suffix ‘C6’ to the model number eg. AFM60US24C6. 5. For white case version add suffix -W. MOQ applies, contact sales for details. 6. Other output voltages are available, contact sales for details. 7. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 8. A minimum load of 1% is required to meet performance criteria A. 9. Performance criteria given for high line input. Mechanical Details 37.4 ±2 (950 ±50) 1.31 (33.4) Output Plug: ø 5.5 x ø 2.5 x 11.0 mm inner positive LED Indicator A Optional AC Cable Restraint (see note 8 below) 0.53 (13.7) 0.66 (16.8) 0.07 (1.8) 80º 1 1.4 .0) (36 C 0.68 (17.3) 0.17 (4.4) B A B C AFM30 & 45 AFM60 4.76 (121.0) 1.97 (50.0) 1.21 (30.8) 4.92 (125.0) 2.44 (62.0) 1.33 (34.0) Standard AC INLET IEC-320-C14 Optional C6 AC INLET IEC-320-C6 Optional C8P AC INLET IEC-320-C8P Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: AFM45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx. 3. Case material is PC Class 94 V-0. 4. Output Lead: UL1185, 16 AWG 5. For European mains lead order part EU-MAINS-IEC for C14 versions, EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions. 6. For UK mains lead order part UK-MAINS-IEC for C14 versions, UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions. 7. For US mains lead order part US-MAINS-IEC for C14 versions, US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions. 8. For optional AC Cable Restraint on the standard input version add suffix ‘‘A’ to the model number e.g. AFM60US24A. AC Mains Lead must be Interpower Corporation, part number 70006020300. Option AC Cable Restraint is not available on IEC320-C6 inlet or Class II versions. 9. The standard C7 cable fits the C8P connector. 19-Oct-15 AC-DC AFM30-60 Models and Ratings