XP Power AFM45US24 Energy efficiency level v Datasheet

AC-DC
30-60 Watts
AFM Series
xppower.com
•
Energy Efficiency Level V
•
CEC2008 & EISA2007 Compliant
•
IT & Medical Approvals
•
China Compulsory Certification (CCC) Qualified
•
Optional Class II Versions
•
Optional White Case Versions
•
3 Year Warranty
Specification
Input
General
• 80-264 VAC, derate output power 25%
<90 VAC
Input Frequency
• 47-63 Hz
Input Current
• AFM30: 0.8 A rms at 115VAC,
AFM45: 1.2 A rms at 115VAC,
AFM60: 1.5 A rms at 115 VAC
Inrush Current
• AFM30: 50 A max at 240VAC,
AFM45: 50 A max at 240VAC,
AFM60: 120 A max at 240VAC
Power Factor
• EN61000-3-2, class A
Earth Leakage Current • 150 µA max at 264 VAC/60 Hz
No Load Input Power • AFM30/45: <0.3 W, AFM60: <0.5 W
Input Voltage
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
•
Coefficient
See table
Not user-adjustable
±2%
No minimum load required
3 s max at 115 VAC
8 ms minimum at 115 VAC
±1.0% maximum
2.5% maximum
4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
1% max pk-pk (1)
110-170% Vnom, recycle input to reset
AFM45/60: 110-170%,
AFM30: 110-220%, auto recovery
Trip and restart (hiccup mode)
0.04%/°C
Efficiency
Energy Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• See table
• Level V
• 4000 VAC Input to Output, 2 x MOPP
1500 VAC Input to Ground, 1 x MOPP*
Output 0 V is electrically connected to
Input Ground*. *Not C8 version.
• 30/45 W: 58 kHz typ., 60 W: 52 kHz typ.
• AFM30: 2.8 W/In3, AFM45: 4.2 W/In3,
AFM60: 3.76 W/In3
• >250 kHrs to MIL-HDBK-217F at 25 °C,
GB, full load
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 60% power at +60 °C
Operating Humidity
• 10-95% RH, non-condensing
Storage Temperature
• -40 °C to +80 °C
Operating Altitude
• 2000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55011/22/FCC Class B conducted,
EN55011/22/FCC Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, 6 kV contact and
8 kV air discharge
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A (7)
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, 3 Vrms Perf Criteria A
• EN61000-4-8, 3 A/m, Perf Criteria A
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf A, A, A, B (8)
• EN60950-1, UL60950-1, IEC60950-1
EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.),
IEC60601-1 (3rd Ed.) China Compulsory
Certification (CCC) Qualified.
Output Power
Output Voltage(6)
30 W
30 W
30 W
30 W
48 W
48 W
48 W
48 W
60 W
60 W
60 W
60 W
12 V
15 V
18 V
24 V
12 V
15 V
18 V
24 V
12 V
15 V
18 V
24 V
Output Current
2.50
2.00
1.67
1.25
4.00
3.20
2.67
2.00
5.00
4.00
3.34
2.50
Efficiency(7)
Model Number(3,4,5)
87.9%
88.4%
87.6%
88.0%
87.7%
88.0%
87.2%
87.7%
87.3%
88.2%
88.3%
87.8%
AFM30US12
AFM30US15
AFM30US18
AFM30US24
AFM45US12
AFM45US15
AFM45US18
AFM45US24
AFM60US12
AFM60US15
AFM60US18
AFM60US24
A
A
A
A
A
A
A
A
A
A
A
A
Notes
1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and
0.1 µF ceramic cap connected at the measurement point.
2. Total regulation includes initial set accuracy, line and load regulation.
3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix ‘C2’
to the model number, e.g. AFM60US24C2.
4. For alternative IEC320-C6 inlet, add suffix ‘C6’ to the model number
eg. AFM60US24C6.
5. For white case version add suffix -W. MOQ applies, contact sales for details.
6. Other output voltages are available, contact sales for details.
7. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
8. A minimum load of 1% is required to meet performance criteria A.
9. Performance criteria given for high line input.
Mechanical Details
37.4 ±2 (950 ±50)
1.31
(33.4)
Output Plug: ø 5.5 x ø 2.5 x 11.0 mm
inner positive
LED Indicator
A
Optional AC Cable Restraint (see note 8 below)
0.53
(13.7)
0.66
(16.8)
0.07
(1.8)
80º
1
1.4 .0)
(36
C
0.68
(17.3)
0.17
(4.4)
B
A
B
C
AFM30 & 45
AFM60
4.76 (121.0)
1.97 (50.0)
1.21 (30.8)
4.92 (125.0)
2.44 (62.0)
1.33 (34.0)
Standard AC INLET
IEC-320-C14
Optional C6 AC INLET
IEC-320-C6
Optional C8P AC INLET
IEC-320-C8P
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
2. Weight: AFM45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx.
3. Case material is PC Class 94 V-0.
4. Output Lead: UL1185, 16 AWG
5. For European mains lead order part EU-MAINS-IEC for C14 versions,
EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions.
6. For UK mains lead order part UK-MAINS-IEC for C14 versions,
UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions.
7. For US mains lead order part US-MAINS-IEC for C14 versions,
US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions.
8. For optional AC Cable Restraint on the standard input version add suffix ‘‘A’ to
the model number e.g. AFM60US24A. AC Mains Lead must be Interpower
Corporation, part number 70006020300. Option AC Cable Restraint is not
available on IEC320-C6 inlet or Class II versions.