Lumileds LXK8-PW35-0008 High efficacy plug and play array solution with precise flux, vf and color Datasheet

LUXEON K
High efficacy plug and play array solution
with precise flux, Vf and color
Introduction
The LUXEON K arrays deliver high flux at high efficacy in a small, easy to use package. The high lumen density
enables high light output in thermally and space constrained systems like retrofit lamps and high efficiency in
systems like downlights aiming for high energy efficiency. The small size bolt down package enables simple assembly
in space constrained systems. With Freedom from Binning, every LUXEON K white product falls within a single
3-step MacAdam ellipse positioned around the center point of the ANSI nominal CCT bins to deliver tight Correlated
Color Temperature control to ensure consistency in system color point. In addition, these parts deliver the lumen
maintenance and reliability that all LUXEON LEDs are renowned for. This document contains the performance data
needed to design and engineer LUXEON K based applications.
Features
Benefits
Key Applications
• Fully characterized ‘light source’ with
• Drop-in solution for cost
• Downlights
Freedom from Binning
• High flux density and lumen offerings
of 400-5000+
• CCTs from 2700K to 6500K and
Royal Blue
• High flux density for compact lamp
solutions
• 3 SDCM color consistency
• Industry’s smallest Vf (+/- 5%)
competitive applications
• Exceptional lamp to lamp
consistency (<3MA)
• Single color, flux, or Vf bin
• Easy mechanical assembly
• Reduction in total cost – no
binning or PnP
• Faster time to market – ease
of design/assembly
& flux range (+/- 10%)
• LM-80 test reports available
• Comprehensive and enabling
ecosystem
LUXEON K Datasheet DS102 ©2014 Philips Lumileds Lighting Company. • Lamps
Table of Contents
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Lead Soldering Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Relative Spectral Distribution vs. Wavelength Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Light Output Characteristics over Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Typical Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Typical Radiation Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Packaging on Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
LUXEON K White ANSI Color Bin Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. i
General Information
Product Nomenclature
LUXEON K products are specified and binned “hot” (Tj = 85°C) under conditions comparable to those found in
“real-world” lighting products. The part number designation is explained as follows:
LXKA-PBCD-EFGHJ
Where:
A
—
B
—
designates minimum CRI performance (value 8 = 80 minimum, value 9 = 90 minimum, value 0 for
Royal Blue)
designates color (value W = White, value R = Royal Blue)
C, D —
designates nominal ANSI CCT (value 27 = 2700K, 30 = 3000K, 35 = 3500K, 40 = 4000K, 50 = 5000K, and 04 = Royal Blue 447.5nm - 452.5nm peak wavelength)
E, F —
custom spec designation or multi-junction designation (F - Number of strings, H number of emitters,
for example 0206, 2 strings of 3 = total emitters of 6)
G, H —
emitter count
J
denotes a flux upgrade (e.g, A, B, C, etc)
—
Therefore, 3000K products specified at 350 mA 85°C follow the part numbering scheme:
L X K 8 - P W 3 0 - 0 0 0 4 for LUXEON K White 3000K 4-up
L X K 8 - P W 3 0 - 0 0 0 8 for LUXEON K White 3000K 8-up
L X K 0 - P R 0 4 - 0 0 0 8 for LUXEON K Royal Blue 8-up Average Lumen Maintenance Characteristics
Lumen maintenance for solid-state lighting devices (LEDs) is typically defined in terms of the percentage of initial
light output remaining after a specified period of time. Philips Lumileds projects that LUXEON K products will deliver,
on average, 70% lumen maintenance (L70) at 50,000 hours of operation at a forward current of up to 700 mA. This
projection is based on constant current operation with junction temperature maintained at or below 125°C. This
performance is based on independent test data, Philips Lumileds historical data from tests run on similar material
systems, and internal LUXEON reliability testing. Observation of design limits included in this data sheet is required in
order to achieve this projected lumen maintenance.
Environmental Compliance
Philips Lumileds is committed to providing environmentally friendly products to the solid-state lighting market.
LUXEON K is compliant to the European Union directives on the restriction of hazardous substances in electronic
equipment, namely the RoHS directive. Philips Lumileds will not intentionally add the following restricted materials to
the LUXEON K: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated
diphenyl ethers (PBDE).
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 2
Product Selection
Product Selection Guide for LUXEON K White,
Junction Temperature = 85°C
Table 1.
Nominal
CCT
Emitter
Count
Part
Number
Test Current
(mA)
Minimum
CRI
Typical
CRI
Minimum Flux
(lm)
Typical Flux (lm)
Maximum Flux
(lm)
3
LXK8-PW27-0403
87.5
80
83
270
285
320
2700
4
LXK8-PW27-0004A
350
80
83
360
401
430
2700
*
4
LXK8-PW27-0404
87.5
80
83
340
370
410
2700
*
6
LXK8-PW27-0206
175
80
83
530
555
640
2700
8
LXK8-PW27-0008A
350
80
83
730
765
870
2700
12
LXK8-PW27-0012A
350
80
83
1100
1148
1320
2700
16
LXK8-PW27-0016A
350
80
83
1480
1530
1770
2700
24
LXK8-PW27-0024A
350
80
83
2230
2378
2670
3000
*
3
LXK8-PW30-0403
87.5
80
83
270
285
320
3000
4
LXK8-PW30-0004A
350
80
83
380
426
450
3000
*
4
LXK8-PW30-0404
87.5
80
83
355
385
420
3000
*
6
LXK8-PW30-0206
175
80
83
540
575
650
3000
8
LXK8-PW30-0008A
350
80
83
760
783
910
3000
12
LXK8-PW30-0012A
350
80
83
1140
1200
1360
3000
16
LXK8-PW30-0016A
350
80
83
1520
1568
1820
3000
24
LXK8-PW30-0024A
350
80
83
2280
2445
2730
3500
4
LXK8-PW35-0004
350
80
83
400
423
480
3500
8
LXK8-PW35-0008
350
80
83
820
845
980
3500
12
LXK8-PW35-0012
350
80
83
1200
1265
1440
3500
16
LXK8-PW35-0016
350
80
83
1590
1703
1900
2900
2700
*
3500
24
LXK8-PW35-0024
350
80
83
2420
2570
4000
*
3
LXK8-PW40-0403
87.5
80
83
310
330
370
4000
4
LXK8-PW40-0004A
350
80
83
420
445
500
4000
*
4000
*
4
LXK8-PW40-0404
87.5
80
83
410
430
490
6
LXK8-PW40-0206
175
80
83
625
660
750
4000
8
LXK8-PW40-0008A
350
80
83
820
886
980
4000
12
LXK8-PW40-0012A
350
80
83
1250
1329
1500
4000
16
LXK8-PW40-0016A
350
80
83
1680
1860
2010
4000
24
LXK8-PW40-0024A
350
80
83
2530
2660
3030
5000K
4
LXK8-PW50-0004
350
80
83
440
463
530
5000K
6
LXK8-PW50-0206
350
80
83
640
675
770
5000K
8
LXK8-PW50-0008
350
80
83
890
933
1070
5000K
12
LXK8-PW50-0012
350
80
83
1310
1389
1570
5000K
16
LXK8-PW50-0016
350
80
83
1760
1850
2110
5000K
24
LXK8-PW50-0024
350
80
83
2650
2767
3180
Table 1 continued on page 4.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 3
Table 1 Continued.
Nominal
CCT
Emitter
Count
Part
Number
Test Current
(mA)
Minimum
CRI
Typical
CRI
Minimum Flux
(lm)
Typical Flux (lm)
Maximum Flux
(lm)
3000
8
LXK7-PW30-0008
350
70
73
1020
1070
1225
3000
12
LXK7-PW30-0012
350
70
73
1490
1565
1785
3000
16
LXK7-PW30-0016
350
70
73
2005
2105
2405
4000
8
LXK7-PW40-0008
350
70
73
1020
1071
1225
4000
12
LXK7-PW40-0012
350
70
73
1560
1638
1870
4000
16
LXK7-PW40-0016
350
70
73
2040
2150
2445
2700
4
LXK9-PW27-0004
350
90
93
300
320
360
2700
8
LXK9-PW27-0008
350
90
93
610
640
730
2700
12
LXK9-PW27-0012
350
90
93
940
960
1120
2700
16
LXK9-PW27-0016
350
90
93
1265
1280
1510
2700
24
LXK9-PW27-0024
350
90
93
1880
1925
2250
3000
4
LXK9-PW30-0004
350
90
93
320
350
380
3000
8
LXK9-PW30-0008
350
90
93
660
695
790
3000
12
LXK9-PW30-0012
350
90
93
1010
1050
1210
3000
16
LXK9-PW30-0016
350
90
93
1350
1400
1620
3000
24
LXK9-PW30-0024
350
90
93
2045
2110
2450
2700**
4
LXK8-PW27-0004
350
80
83
310
345
370
**
2700
8
LXK8-PW27-0008
350
80
83
680
690
810
2700**
12
LXK8-PW27-0012
350
80
83
990
1045
1180
2700**
16
LXK8-PW27-0016
350
80
83
1380
1395
1650
2700
24
LXK8-PW27-0024
350
80
83
1960
2090
2350
3000**
4
LXK8-PW30-0004
350
80
83
330
370
390
3000**
8
LXK8-PW30-0008
350
80
83
730
740
870
**
**
3000
12
LXK8-PW30-0012
350
80
83
1070
1125
1280
3000**
16
LXK8-PW30-0016
350
80
83
1475
1500
1770
2520
3000
24
LXK8-PW30-0024
350
80
83
2100
2250
4000**
4
LXK8-PW40-0004
350
80
83
380
410
450
4000**
8
LXK8-PW40-0008
350
80
83
780
815
930
**
4000**
12
LXK8-PW40-0012
350
80
83
1120
1240
1340
4000**
16
LXK8-PW40-0016
350
80
83
1590
1650
1900
4000**
24
LXK8-PW40-0024
350
80
83
2260
2475
2710
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ± 6.5% on luminous flux and ± 2 on CRI measurements.
2. * = High voltage multi-junction.
3. ** = Parts with original flux performance (before flux upgrade).
Product Selection Guide for LUXEON K Royal Blue,
Junction Temperature = 85°C, Test Current = 350 mA
Table 2.
Color
Emitter
Count
Part
Number
Minimum
Radiometric Power
(mW)
Typical
Radiometric Power
(mW)
Maximum
Radiometric Power
(mW)
Typical Radiant
Efficiency (%)
Royal Blue
8
LXK0-PR04-0008
4500
4670
5400
62%
Royal Blue
16
LXK0-PR04-0016
9000
9350
10800
62%
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 4
Optical Characteristics
LUXEON K White at Test Current, Junction Temperature = 85°C
Table 3.
Nominal
CCT
Part Number
Color Temperature
CCT
Typical
Typical Total
Included Angle [2]
(degrees) u90V
Typical
Viewing Angle [2]
(degrees) 2u ½
LXKx-PW27-xxxx(A)
2700K
2725K
125
100
LXKx-PW30-xxxx(A)
3000K
3045K
125
100
LXKx-PW35-xxxx
3500K
3465K
125
100
LXKx-PW40-xxxx(A)
4000K
3985K
125
100
LXKx-PW50-xxxx
5000K
5028K
125
100
Notes for Table 3:
1. Total angle at which 90% of total luminous flux is captured. 2. Viewing angle is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value.
LUXEON K Royal Blue (LXK0-PRxx) at Test Current [1], Junction Temperature = 85°C
Table 4.
Peak Wavelength, lp[2]
Min
Typ
Max
Typical Spectral
Half-width (nm)[3]
Dl1/2
447.5nm
450nm
452.5nm
20
Part Color
Royal Blue
Typical Temp
Coefficient of Peak
Wavelength (nm/°C)
Dl1/2
Typical Total
Included Angle [4]
(degrees) u90V
Typical
Viewing Angle [5]
(degrees) 2u ½
0.05
140
116
Notes for Table 4:
1. Test current is 350 mA for all LXK0-PRxx products.
2. Royal Blue product has single peak wavelength bin.
3. Spectral half-width is ½ of the peak intensity.
4. Total included angle at which 90% of total radiometric power is captured.
5. Viewing angle is the off-axis angle from lamp centerline where the luminous intensity is ½ of the peak value.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 5
Electrical Characteristics
Electrical Characteristics at Test Current for LUXEON K White and Royal Blue,
Junction Temperature = 85°C
Table 5.
Forward Voltage Vf [1] (V)
Part Number
Typical
Temperature Coefficient
of Forward Voltage
(mV/°C)
DVF / DTJ
Typical
Thermal Resistance
Junction to Case (°C/W)
Ru J-C
Minimum
Typical
Maximum
LXKx-Pxxx-0403
30
31.5
33.8
-21.0
5.5
LXKx-Pxxx-xx04(A)
10
10.5
11.3
-6.3
3.0
LXKx-Pxxx-x404
40
42
45.1
-30.1
3.0
LXKx-Pxxx-xx08(A)
20
21
22.6
-12.5
1.5
LXKx-Pxxx-x206
30
31.5
33.8
-21.0
2.3
LXKx-Pxxx-xx12(A)
30
31.5
33.8
-18.8
1.0
LXKx-Pxxx-xx16(A)
40
42
45.1
-25.0
0.8
LXKx-Pxxx-xx24(A)
60
63
67.7
-37.5
0.5
Notes for Table 5:
1. Philips Lumlileds maintains a tester tolerance of 0.5% on forward voltage measurements.
2. Junction temperature to back of the PCB.
Typical Electrical Characteristics at Twice the Test Current for LUXEON K White and
Royal Blue, Junction Temperature = 85°C
Table 6.
Part Number
Typical Forward Voltage
Vf (V)
Test Current
(mA)
LXKx-Pxxx-x403
36
87.5
LXKx-Pxxx-xx04(A)
11
350
LXKx-Pxxx-x404
48
87.5
LXKx-Pxxx-xx08(A)
22
350
LXKx-Pxxx-x206
36
175
LXKx-Pxxx-xx12(A)
33
350
LXKx-Pxxx-xx16(A)
44
350
LXKx-Pxxx-xx24(A)
66
350
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 6
Absolute Maximum Ratings
Table 7.
Maximum Performance
Parameter
LXKx-Pxxx-x004/x006/x008/
x012/x016/x024
LXKx-Pxxx-x403/x404
LXKx-Pxxx-x206
DC Forward Current (mA)
1050
300
600
Peak Pulsed Forward Current (mA)
1050
300
600
ESD Sensitivity
< 8000V Human Body Model (HBM) Class 3A JESD22-A114-E
< 400V Machine Model (MM) Class B JESD22-A115-B
LED Junction Temperature [1]
125°C
Operating Case Temperature
-40°C - 125°C
Storage Temperature
-40°C - 125°C
Reverse Voltage (Vr)
See Note 2
Notes for Table 7:
1. Proper current derating must be observed to maintain junction temperature below the maximum.
2. LUXEON Power LEDs are not designed to be driven in reverse bias.
Electrical Lead Soldering Characteristics
Please refer to Application Brief AB102 for LUXEON K.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 7
Mechanical Dimensions
LXKx-Pxxx-xxx3
Figure 1. Dimensions for LXKx-Pxxx-xxx3.
Notes for Figure 1:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 8
LXKx-Pxxx-xxx4(A)
3
1.
(2
50
PL
C
PL
17.67
17.47
C
S)
B
7.50 (2PLCS)
3.62
3.22
1.50
(2PLCS)
9.40
R0.50
45
0.31 (2PLCS)
2 (2PLCS)
19.1
18.8 5
5
3.30
Dome Pitch
5.46
(2PLCS)
6.25 (2PLCS)
2.
86
1.65
2.10
.0
°
8.50 (2PLCS)
0.50
Max. runner height
from PCB surface
S)
(2
A
6.25 (2PLCS)
72
5.
(2
PL
A
(2
C
PL
S)
S)
C
1
0.76
Silicone height
from PCB surface
3.30
Dome Pitch
R1.50
(4PLCS)
1.65
1.265
1.045
Board Thickness
3.40
3.20
(2PLCS)
2.40
2.20
(2PLCS)
DETAIL A
SCALE 10 : 1
0.50
3.45
2D Barcode
45.0°
1.90
6.90
R1
(2X)
5.
5
9
3.30
Wire slot (2PLCS)
R1 (2PLCS)
R0.50
(5PLCS)
3.45
6.90
R1 (2PLCS)
DETAIL B
Figure 2. Dimensions for LXKx-Pxxx-xxx4(A).
Notes for Figure 2:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 9
LXKx-Pxxx-xxx6
Figure 3. Dimensions for LXKx-Pxxx-xxx6.
Notes for Figure 3:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 10
LXKx-Pxxx-xx08(A)
1.
50
(2
PL
PL
3.62
3.22
C
C
S)
S)
0.50
Max. runner height
from PCB surface
B
2 (2PLCS)
1.50
(2PLCS)
45
.0°
0.15
(2PLCS)
7.13
(2PLCS)
2.
80
5.
60
(2
(2
PL
PL
22.65
22.35
C
C
5.77 (2PLCS)
10.95
10.75 (2PLCS)
10
9.95
(2PLCS)
9.75
3
(2
5
.6 5
21 1.3
2
2
21 1.7
.2 5
5
A
8.98
(2PLCS)
S)
S)
A
4.60
R1.50
(8PLCS)
0.76
Silicone height
from PCB surface
1
3.35
3.25
(2PLCS)
1.265
1.045
Board Thickness
2
DETAIL A
SCALE 8 : 1
2.45
2.35
2.25
(2PLCS)
3.85
2D Barcode
0.64
5.46
3.87
5.65
R1
(2PLCS)
45.0°
5.53
51.43°
Dome Array (7X)
5.43
DETAIL B
3.30
Wire slot (2PLCS)
R1
(2PLCS)
Figure 4. Dimensions for LXKx-Pxxx-xxx8(A).
Notes for Figure 4:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 11
LXKx-Pxxx-xx12(A)
3
(2
PL
C
PL
(2
2
23 4.4
.9 5
5
50
1.
A
S)
C
8.37 (2PLCS)
1.50 (2PLCS)
45.0°
0.80 (2PLCS)
80
60
5.
(2
25.15
24.85
C
S)
A
10.97 (2PLCS)
C
PL
(2
PL
3.30 (3PLCS)
Dome Pitch
S)
2.
4.63 (2PLCS)
2 (2PLC
6
12.10
11.90 (2PLCS)
0.50
Max. runner height
from PCB surface
1.65
10.70
11.10
10.90 (2PLCS)
S)
B
3.62
3.22
2
24 4.3
.0 5
5
S)
5.80
0.76
Silicone height
from PCB surface
3.30 (3PLCS)
Dome Pitch
R1.50
(12PLCS)
1.65
1.265
1.045
Board Thickness
3.35
3.25
(2PLCS)
1
2.35
2.25
(2PLCS)
2
DETAIL A
SCALE 8 : 1
13.50
6.75
R1 (8X)
ire
slo 3.3
t( 0
2P
LC
S)
2D Barcode
W
13.50
R1 (2PLCS)
6.75
DETAIL B
3.35 x 45 Chamfer
(4PLCS)
)
PLCS
R1 (2
Figure 5. Dimensions for LXKx-Pxxx-xx12(A).
Notes for Figure 5:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 12
2
23 4.4
.9 5
5
LXKx-Pxxx-xx16(A)
1.
50
(2
PL
PL
C
S)
C
3.62
3.22
2
24 4.3
.0 5
5
S)
0.50
Max. runner height
from PCB surface
B
8.37 (2PLCS)
2.
S)
C )
S
PL
C
PL
(2
60
(2
5.
80
3.30 (3PLCS)
Dome Pitch
0.80 (2PLCS)
6
25.15
24.85
4.63 (2PLCS)
45
.0
°
1.65
1.50 (2PLCS)
2
(2PLCS)
12.10
11.90 (2PLCS)
11.10
10.90 (2PLCS)
10.70
A
3
(2
10.97
(2PLCS)
A
5.80
0.76
Silicone height
from PCB surface
3.30 (3PLCS)
Dome Pitch
R1.50
(16PLCS)
1.265
1.045
Board Thickness
1.65
3.35
3.25
(2PLCS)
1
2.35
2.25
(2PLCS)
2
DETAIL A
SCALE 8 : 1
R0.70
(4PLCS)
S)
1.92
0.97
2D BARCODE
3
Wir .30
es
lot
(2P
LC
6.75
2.20
13.50
R1 (2PLCS)
6.75
13.50
R1 (2PLCS)
DETAIL B
SCALE 4 : 1
Figure 6. Dimensions for LXKx-Pxxx-xx16(A).
Notes for Figure 6:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 13
LXKx-Pxxx-xx24(A)
30.15
29.85
18.30
9.15
C1.1 x 45
(2X)
8.20 (2X)
0.50
Max. runner height
from PCB surface
R4.05 (3X)
1.50 (2X)
4.90
4.70
(4PLCS)
15
3 (2X)
R1.50
(2PLCS)
3.62
3.22
A
14.40
14.20 (4PLCS)
3.6mm x 45 CHAMFER
2 (2PLCS)
5.33 (2PLCS)
C1.1 x 45
A
11.84 (4PLCS)
1.50 (2PLCS)
1.265
1.045
Board Thickness
R1
1.15
7 (2X)
4.667 (2X)
2.333 (2X)
)
PLCS
R1 (4
2.05
0.35
R1.50
(24PLCS)
2.333 (2X)
7 (2X)
1.35 (2X)
R0.75
4.667 (2X)
15
12.27 (4PLCS)
13.40
13.20 (4PLCS)
10 (2PLCS)
30.25
29.75
18.30
15
LCS)
5 (4P
R1.6 e slot
ir
W
R1
CS)
(4PL
1.35
0.76
Silicone height
from PCB surface
R1.20
2D barcode
2.35
2.25
(4PLCS)
3.35
3.25
(4PLCS)
1
DETAIL A
SCALE 6 : 1
Figure 7. Dimensions for LXKx-Pxxx-xx24(A).
Notes for Figure 7:
1. All dimensions are in millimeters.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 14
Relative Spectral Distribution vs. Wavelength Characteristics
LXK8-PWxx-xxxx at Test Current, Junction Temperature = 85°C
Figure 8. Color spectrum of LXK8-PWxx-xxxx product, integrated measurement.
LXK0-PR04-xxxx (Royal Blue) at Test Current, Junction Temperature = 85°C
Figure 9. Color spectrum of LXK0-PR04-xxxx product, integrated measurement.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 15
Light Output Characteristics over Temperature
All LUXEON K Products at Test Current, Normalized at Test Current,
Junction Temperature = 85°C
Figure 10. Typical relative flux vs. junction temperature at test current.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 16
Typical Forward Current Characteristics
Typical Forward Current vs. Forward Voltage LUXEON K 3-up Products,
Junction Temperature = 85°C
Figure 11. Forward current vs. forward voltage for LXKx-Pxxx-x403 products.
Typical Forward Current vs. Forward Voltage LUXEON K 4-up Products,
Junction Temperature = 85°C
Figure 12. Forward current vs. forward voltage for LXKx-Pxxx-0004(A) products.
Note for Figure 12:
1. LUXEON LXKx-Pxxx-0004(A) is single junction product.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 17
Typical Forward Current vs. Forward Voltage LUXEON K 4-up High-Voltage
Products, Junction Temperature = 85°C
Figure 13. Forward current vs. forward voltage for LXKx-Pxxx-x404 products.
Typical Forward Current vs. Forward Voltage LUXEON K 6-up High-Voltage
Products, Junction Temperature = 85°C
Figure 14. Forward current vs. forward voltage for LXKx-Pxxx-x206 products.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 18
Typical Forward Current vs. Forward Voltage LUXEON K 8-up Products,
Junction Temperature = 85°C
Figure 15. Forward current vs. forward voltage for LXKx-Pxxx-xxx8(A) products.
Typical Forward Current vs. Forward Voltage LUXEON K 12-up Products,
Junction Temperature = 85°C
Figure 16. Forward current vs. forward voltage for LXKx-Pxxx-xx12(A) products.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 19
Typical Forward Current vs. Forward Voltage LUXEON K 16-up Products,
Junction Temperature = 85°C
Figure 17. Forward current vs. forward voltage for LXKx-Pxxx-xx16(A) products.
Typical Forward Current vs. Forward Voltage LUXEON K 24-up Products,
Junction Temperature = 85°C
Figure 18. Forward current vs. forward voltage for LXKx-Pxxx-xx24(A) products.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 20
Typical Relative Luminous Flus vs. Forward Current for ALL LUXEON K Product
Configurations Without Multi-Junction Die, Junction Temperature 85°C
Figure 19. Typical relative luminous flux vs. forward current.
Typical Relative Luminous Flus vs. Forward Current for ALL LUXEON K Product
Configurations With Multi-Junction Die, Junction Temperature 85°C
Figure 20. Typical relative luminous flux vs. forward current for LUXEON K (LXKx-PWxx-0206) with multi-junction die.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 21
Typical Relative Luminous Flus vs. Forward Current for LUXEON K
LXKx-PWxx-0403/LXKx-PWxx-0404 Product Configurations With Multi-Junction
Die, Junction Temperature 85°C
Figure 21. Typical relative luminous flux vs. forward current
for LUXEON K (LXKx-PWxx-0403/LXKx-PWxx-0404) with multi-junction die.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 22
Typical Radiation Patterns
Typical Spatial Radiation Pattern for LUXEON K
120
Relative Intensity (%)
100
80
60
40
20
0
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Angular Displacement (degrees)
Figure 22. Typical representative spatial radiation pattern for LUXEON K.
Packaging on Trays
LUXEON K products will be securely packaged in trays.
Table 8.
Part Number
Tray Dimensions
Quantity per Tray
Number of Trays per Box
LXKx-Pxxx-xxx3
LXKx-Pxxx-xxx4(A)
315mm width x 135.9mm length x 12.11mm depth
40
10
LXKx-Pxxx-xxx6
LXKx-Pxxx-xxx8(A)
315mm width x 135.9mm length x 12.11mm depth
27
10
LXKx-Pxxx-xx12(A)
LXKx-Pxxx-xx16(A)
315mm width x 135.9mm length x 12.11mm depth
24
10
LXKx-Pxxx-xx24
315mm width x 135.9mm length x 12.11mm depth
21
10
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 23
Tray Dimensions – LXKx-Pxxx-xxx3 and LXKx-Pxxx-xxx4(A)
Figure 23.
Tray Dimensions – LXKx-Pxxx-xxx6 and LXKx-Pxxx-xxx8(A)
Figure 24.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 24
Tray Dimensions – LXKx-Pxxx-xx12(A) and LXKx-Pxxx-xx16(A)
Figure 25.
Tray Dimensions – LXKx-Pxxx-xx24(A)
Figure 26.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 25
LUXEON K White ANSI Color Bin Definition
0.440
2700K ANSI
3000K ANSI
0.420
Blackbody
Locus
3500K ANSI
4000K ANSI
CIE
E 1931 y
0.400
0.380
5000K ANSI
0.360
2700K 3-step MacAdams Ellipse
3000K 3-step MacAdams Ellipse
0.340
3500K 3-step MacAdams Ellipse
4000K 3-step MacAdams Ellipse
0.320
0.320
5000K 3-step MacAdams Ellipse
0.340
0.360
0.380
0.400
0.420
0.440
0.460
0.480
0.500
CIE 1931 x
Figure 27. Graph of LUXEON K ANSI bin color definition.
Table 9. LUXEON K 3-step MacAdams Ellipse Color Definition
2700K
3000K
3500K
4000K
5000K
Nominal ANSI CCT
Single 3-step
MacAdam ellipse
Single 3-step
MacAdam ellipse
Single 3-step
MacAdam ellipse
Single 3-step
MacAdam ellipse
Single 3-step
MacAdam ellipse
Center Point (cx, cy)[1]
(0.4578, 0.4101 )
(0.4338, 0.4030)
(0.4073, 0.3917)
(0.3818, 0.3797)
(0.3447, 0.3553)
Major Axis, a
0.0081
0.00834
0.00927
0.00939
0.00822
Minor Axis, b
0.0042
0.00408
0.00414
0.00402
0.00354
Ellipse rotation angle
53.7°
53.22°
54.00°
53.72°
59.62°
Note for Table 9:
1. Philips Lumileds maintains a tester tolerance of ±0.005 on x, y color coordinates.
LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 26
Who We Are
Philips Lumileds focuses on one goal: Creating the world’s highest performing LEDs. The company pioneered the use
of solid-state lighting in breakthrough products such as the first LED backlit TV, the first LED flash in camera phones,
and the first LED daytime running lights for cars. Today we offer the most comprehensive portfolio of high quality
LEDs and uncompromising service.
Philips Lumileds brings LED’s qualities of energy efficiency, digital control and long life to spotlights, downlights,
high bay and low bay lighting, indoor area lighting, architectural and specialty lighting as well as retrofit lamps. Our
products are engineered for optimal light quality and unprecedented efficacy at the lowest overall cost. By offering
LEDs in chip, packaged and module form, we deliver supply chain flexibility to the inventors of next generation
illumination.
Philips Lumileds understands that solid state lighting is not just about energy efficiency. It is about elegant design.
Reinventing form. Engineering new materials. Pioneering markets and simplifying the supply chain. It’s about a
shared vision. Learn more about our comprehensive portfolio of LEDs at www.philipslumileds.com. Philips Lumileds Lighting Company shall not be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. Although
Philips Lumileds Lighting Company has attempted to provide the most accurate information and data, the materials and services information and data are provided “as is” and Philips Lumileds Lighting Company
neither warranties, nor guarantees the contents and correctness of the provided information and data. Philips Lumileds Lighting Company reserves the right to make changes without notice.
You as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data.
©2014 Philips Lumileds Lighting Company. All rights reserved.
LUXEON is a registered trademark of the Philips Lumileds Lighting
Company in the United States and other countries.
www.philipslumileds.com
www.philipslumileds.cn.com
LUXEON K Datasheet DS102 20140404
Similar pages