XP Power CU20-09 Single outputs from 3.3 v to 24 v Datasheet

ACDC
20 Watts
CU20 Series
xppower.com
•
Low Cost
•
Small Size
•
Universal Input
•
Single Outputs from 3.3 V to 24 V
•
Peak Load Capability
•
Low Profile
•
Nonstandard Outputs Available
Specification
Input
General
85-264 VAC (120-370 VDC)
47-63 Hz
0.25 A rms at 230 VAC
20 A at 115 VAC, 40 A at 230 VAC,
cold start +25 şC
Earth Leakage Current • <1.5 mA
Input Protection
• 2 A fuse
Input Voltage
Input Frequency
Input Current
Inrush Current
•
•
•
•
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
See table
±5%
±1%
No minimum load required
1.5 s max
14 ms max
16 ms typical at full load & 115 VAC
±0.6%
±0.5% max
±1.0% max
4% max deviation, recovery to within
1% in 500 µs for 25% load change
1% max pk-pk (see note 1)
130-150% of Vnom, recycle input to reset
Trip and restart (Hiccup mode)
0.05%/˚C
• Measured with 230 VAC & 100% load
(See table)
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 67 kHz typical
• 3.91 W/In3
• >500 kHrs per MIL-HDBK-217F
(15 & 24 V units >400 kHrs)
Environmental
Operating Temperature • 0 ˚C to +65 ˚C, derate from 100% load at
+45 ˚C to 0% at +65 ˚C
Cooling
• Convection-cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -20 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Vibration
• 10 Hz to 500 Hz, 2 g for 10 mins/cycle
60 min each cycle
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & interruptions
Safety Approvals
• FCC20780 Level B,
EN55022 Class B conducted
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-3, level 3, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, 10 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 1000 ms, 100% 5000 ms,
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA22.2 No. 60950-1, CE Mark LVD
Output Current
Output
Power
Output
Voltage(3)
Nominal
15 W
3.3 VDC
4.40 A
Peak(2)
6.60 A
5.0 VDC
4.40 A
6.60 A
9.0 VDC
2.44 A
12.0 VDC
20 W
Efficiency
(typical)
Model
Number
70%
CU20-00
73%
CU20-10
4.00 A
77%
CU20-09
1.80 A
2.70 A
80%
CU20-12
15.0 VDC
1.40 A
2.10 A
80%
CU20-13
24.0 VDC
0.92 A
1.40 A
82%
CU20-14
Notes
1. Measured at 20 MHz bandwidth. 3.3 V models are 50 mV maximum.
2. Peak load lasting <30 s with a maximum duty cycle of 10%.
3. Alternative output voltages available. Consult sales.
0.80 (20.32)
Mechanical Details
L
(+) Vout
N
(-) Vout
0.150 (3.81)
2.00 (50.80)
1.70 (43.18)
0.13 (3.30) (4 PL)
0.15 (3.81)
V Adj.
3.20 (81.28)
3.50 (88.90)
weight: 0.220 lb (60 g)
Notes
1. All dimensions shown in inches (mm).
2. CU20 input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. Output connector mates with
Molex housing 90-50-3041 and Molex 2878 series crimp terminal.
3. CU20 cable harnesses with 300mm wire available. Order part number CU20 LOOM KIT †.
4. For mating connectors only, order part number CU20-60 CONKIT †.
5. Covers available. Order part number CU20 COVER † - 4.02” x 2.52” x 1.34” (102 x 64 x 34mm).
To receive unit with cover fitted, add suffix ‘-C’ to model number.
17-Apr-07