Click on Series name for product info on aimtec.com Series AMER150C-CAZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter FEATURES: Models Single output Model • Constant Current or Constant Voltage LED Driver or Converter • Input range 90-305VAC/47-440Hz • High Efficiency up to 89% • 115VAC Operating temperature -50 to 80°C • 230VAC Operating temperature -55 to 80°C • Dimmable via resistive / 0-10Vdc / PWM • 5 Years Limited Warranty Max Output Output Input Input Output Voltage Current Voltage Voltage Power Range ③ (A) (VAC/Hz) (VDC) ① ③ (W) (V) AMER150C-50300CAZ 150 36-50 0-3 90-305/47440 130-430 AMER150C-36420CAZ 150 24-36 0-4.16 90-305/47440 130-430 AMER150C-24630CAZ 144 12-24 0-6.3 90-305/47440 130-430 • • • • • Over Voltage Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Efficiency (%) Mode of Operation 115 230 277 87 87 86 86 85 85 89 88 88 88 87 87 89 89 88 88 87 87 VAC Constant Current ② Constant Voltage Constant Current ② Constant Voltage Constant Current ② Constant Voltage VAC VAC ① Exceeding ③ the maximum output power will permanently damage the converter In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER150C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.J Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type 0.98 0.94 0.92 3.5 900 Tel: +1 514 620 2722 1 of 7 Maximum 2000 1000 900 50 75 90 0.25 3.5 Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ Output Specifications Parameters up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Conditions Typical Maximum Current accuracy ±3 Line regulation LL-HL ±2 Load regulation 0-100% load ±3 200 Ripple & Noise ④ Hold-up time (min) 40 Current adjustment range 100-10 ④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Tested voltage Isolation resistance I/O I/FG O/FG General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Over temperature protection Operating temperature (See Derating Table) Cold Start-up Time Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF Conditions Typical 500 VDC >100 3sec Conditions Maximum VAC VAC VAC MΩ Maximum 100 ≧105 ≧105 Auto recovery >105°C -50 to +80 -55 to +80 (115VAC) (230VAC) -55°C % % % mV p-p ms % Units 3750 2000 500 Typical Units Units KHz % % o 20 100 C C Sec o C o C % / oC 95 % RH o -55 to +95 ±0.02 Free air convection Aluminum Epoxy (IP68 rated) UL1015 18AWG Input & 14AWG Output *20CM 900 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm >400,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.J CE EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 NOTE: Also designed to Meet cULus, UL8750, UL60950-1 Tel: +1 514 620 2722 2 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Dimensions Top View 181.00 (7.13) 4.00 (0.16) 41.00 (1.73) 27.00 (1.06) 8.00 (0.32) 11.00 (0.43) 23.00 (0.91) End View Side View 200.00 (8.00) 200.00 (8.00) 47.00 (1.85) 59.00 (2.32) 2.30 (0.09) Input/Output Wires are 18 AWG 20cm Measurements in Millimeters (inch) Case Tolerance: ±0.5 (±0.02) Analog (resistive) Dimming Application Circuit AC BROWN L GREEN AMER150-AZ BLUE N F 052.1e R3.J 1 -Vout 1 BLUE WHITE www.aimtec.com +Vout RED 1st LED BLACK Pot Tel: +1 514 620 2722 3 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Derating Free Air Convection CV mode CC Mode 50°C 50°C 100 Output Power (%) 230VAC 80 60 Safe Operating Area 40 20 80°C 0 - 55 - 30 0 20 40 60 80°C 80 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 4 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ Dimming Performance AMEPR150C-50300CAZ www.aimtec.com F 052.1e R3.J up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 5 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ AMER150C-36420CAZ www.aimtec.com F 052.1e R3.J up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 6 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150C-CAZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter AMER150C-24630CAZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 7 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only