AD ADIS16220 Programmable digital vibration sensor Datasheet

Programmable
Digital Vibration Sensor
ADIS16220
FEATURES
GENERAL DESCRIPTION
Digital ±70 g accelerometer/vibration sensing
22 kHz sensor resonance
100.2 kSPS sample rate
SPI-compatible serial interface
Programmable data capture function:
3 channels, 1024 samples each
1 accelerometer/2 auxiliary ADCs (AIN1, AIN2)
Manual trigger for user initiation
Automatic trigger for periodic data capture
Event trigger for condition-driven capture
Digital temperature sensor output
Digitally controlled sample rate
Digitally controlled frequency response
2 auxiliary digital I/Os
Digitally activated self-test
Digitally activated low power mode
Serial number and device ID
Single-supply operation: 3.15 V to 3.6 V
Operating temperature range: −40°C to +125°C
9.2 mm × 9.2 mm 16-terminal LGA
The ADIS16220 iSensor® is a digital vibration sensor that combines industry-leading iMEMS® sensing technology with signal
processing, data capture, and a convenient serial peripheral
interface (SPI). The SPI and data buffer structure provide
convenient access to wide-bandwidth sensor data. The 22 kHz
sensor resonance and 100.2 kSPS sample rate provide adequate
response for most machine-health applications. The averaging/
decimating filter provides optimization controls for lower
bandwidth applications.
An internal clock drives the data sampling system, which fills
the buffer memory for user access. The data capture function
has three different trigger modes. The automatic data collection
allows for periodic wake-up and capture, based on a programmable duty cycle. The manual data capture mode allows the user to
initiate a data capture, providing power and read-rate optimization. The event capture mode continuously updates the buffers
and monitors them for a preset trigger condition. This mode
captures pre-event data and post-event data and produces an
alarm indicator for driving an interrupt.
The ADIS16220 also offers a digital temperature sensor, digital
power supply measurements, and peak output capture.
APPLICATIONS
Vibration analysis
Shock detection and event capture
Condition monitoring
Machine health
Instrumentation, diagnostics
Safety, shut-off sensing
Security sensing, tamper detection
The ADIS16220 comes in a 9.2 mm × 9.2 mm × 3.9 mm LGA
package that meets the Pb-free solder reflow profile requirements per JEDEC J-STD-020 and has an extended operating
temperature range of −40°C to +125°C.
FUNCTION BLOCK DIAGRAM
DIO1
SELF-TEST
DIO2
RST
VDD
I/O
ALARMS
MEMS
SENSOR
CONTROLLER
TEMP
SENSOR
CLOCK
AIN1
AIN2
POWER
MANAGEMENT
USER
CONTROL
REGISTERS
CAPTURE
BUFFER
OUTPUT
DATA
REGISTERS
SCLK
DIN
DOUT
07980-001
ADIS16220
CS
SPI
PORT
FILTER
GND
VREF
Figure 1.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2009 Analog Devices, Inc. All rights reserved.
ADIS16220
TABLE OF CONTENTS
Features .............................................................................................. 1
SPI Read Commands ....................................................................9
Applications ....................................................................................... 1
Data Collection ........................................................................... 11
General Description ......................................................................... 1
Reading Data from the Capture Buffer ................................... 11
Function Block Diagram ................................................................. 1
Capture Mode Configuration ................................................... 12
Revision History ............................................................................... 2
Global Commands ..................................................................... 13
Specifications..................................................................................... 3
Filtering........................................................................................ 13
Timing Specifications .................................................................. 5
Offset Adjustment ...................................................................... 14
Timing Diagrams.......................................................................... 5
Input/Output Functions ............................................................ 14
Absolute Maximum Ratings............................................................ 6
Diagnostics .................................................................................. 14
ESD Caution .................................................................................. 6
Serialization................................................................................. 15
Pin Configuration and Function Descriptions ............................. 7
Flash Memory Management ..................................................... 15
Recommended Pad Layout ......................................................... 7
Applications Information .............................................................. 16
Theory of Operation ........................................................................ 8
Assembly...................................................................................... 16
Sensing Element ........................................................................... 8
Getting Started Quickly ............................................................. 16
Data Sampling and Processing ................................................... 8
Interface Board ........................................................................... 16
User Interface ................................................................................ 8
Outline Dimensions ....................................................................... 17
Basic Operation................................................................................. 9
Ordering Guide .......................................................................... 17
SPI Write Commands .................................................................. 9
REVISION HISTORY
12/09—Revision 0: Initial Version
Rev. 0 | Page 2 of 20
ADIS16220
SPECIFICATIONS
TA = −40°C to +125°C, VDD = 3.3 V, ±1 g, unless otherwise noted.
Table 1.
Parameter
ACCELEROMETER
Measurement Range
Sensitivity
Sensitivity Error
Sensitivity Temperature Coefficient
Nonlinearity
Cross-Axis Sensitivity
Alignment Error
Offset Error
Offset Temperature Coefficient
Output Noise
Output Noise Density
Sensor Resonant Frequency
Self-Test Response
AUXILIARY INPUTS (AIN1, AIN2)
Resolution1
Sensitivity
Integral Nonlinearity
Differential Nonlinearity
Offset
Offset Error
Input Range
Input Capacitance
ON-CHIP VOLTAGE REFEERENCE
Output Level
Accuracy
Temperature Coefficient
Output Impedance
LOGIC INPUTS2
Input High Voltage, VINH
Input Low Voltage, VINL
Logic 1 Input Current, IINH
Logic 0 Input Current, IINL
All Except RST
RST
Input Capacitance, CIN
DIGITAL OUTPUTS2
Output High Voltage, VOH
Output Low Voltage, VOL
FLASH MEMORY
Endurance3
Data Retention4
START-UP TIME5
Initial Startup
Reset Recovery (RST)
Sleep Mode Recovery
Conditions
Min
TA = 25°C
TA = 25°C
TA = 25°C
−70
19.073
±5
±310
±0.2
±2
±1
With respect to full scale
With respect to package
TA = 25°C
Typ
−19.1
TA = 25°C, AVG_CNT = 0x0000
TA = 25°C, 10 Hz to 1 kHz
917
Max
Unit
+70
g
mg/LSB
%
ppm/°C
%
%
Degree
g
mg/°C
mg rms
mg/√Hz
kHz
LSB
±2
+19.1
±5
507
4
22
1310
1703
12
305.18
2.4
4
VDD/2
±20.4
20
Bits
μV/LSB
LSB
LSB
V
LSB
V
pF
2.5
±5
±40
70
V
mV
ppm/°C
Ω
0
VDD
2.0
VIH = 3.3 V
VIL = 0 V
±0.2
−40
−1
10
ISOURCE = 1.6 mA
ISINK = 1.6 mA
0.8
±1
−60
2.4
0.4
10,000
20
TJ = 85°C
RST or software (GLOB_CMD)
Rev. 0 | Page 3 of 20
V
V
μA
μA
mA
pF
V
V
Cycles
Years
160
23
2.3
ms
ms
ms
ADIS16220
Parameter
CONVERSION RATE
Clock Accuracy
POWER SUPPLY
Power Supply Current
Conditions
AVG_CNT = 0x0000
Min
Operating voltage range, VDD
Capture mode, TA = 25°C
Sleep mode, TA = 25°C
Sleep mode, TA = 85°C
Sleep mode, TA = 125°C
3.15
1
Typ
100.2
3
3.3
38
230
250
600
Max
3.6
46
Unit
kSPS
%
V
mA
μA
μA
μA
A 12-bit analog-to-digital converter is used to create a 14-bit digital scale for the AIN1 and AIN2 inputs.
The digital I/O signals are 5 V tolerant.
3
Endurance is qualified as per JEDEC Standard 22, Method A117, and measured at −40°C, +25°C, +85°C, and +125°C.
4
Retention lifetime equivalent at junction temperature (TJ) = 85°C as per JEDEC Standard 22, Method A117. Retention lifetime decreases with junction temperature. See
Figure 16.
5
The start-up times presented do not include the data capture time, which is dependent on the AVG_CNT register settings.
2
Rev. 0 | Page 4 of 20
ADIS16220
TIMING SPECIFICATIONS
TA = 25°C, VDD = 3.3 V, unless otherwise noted.
Table 2.
Parameter
fSCLK
tSTALL
tCS
tDAV
tDSU
tDHD
tSCLKR, tSCLKF
tSR
tSF
tDF, tDR
tSFS
1
Min1
0.01
15.4
48.8
Description
SCLK frequency
Stall period between data, between 16th and 17th SCLK
Chip select to SCLK edge
DOUT valid after SCLK edge
DIN setup time before SCLK rising edge
DIN hold time after SCLK rising edge
SCLK rise/fall times
SCLK high pulse width
SCLK low pulse width
DOUT rise/fall times
CS high after SCLK edge
Typ
Max
2.25
Unit
MHz
μs
ns
ns
ns
ns
ns
ns
ns
ns
ns
100
24.4
48.8
5
12.5
12.5
12.5
12.5
5
5
Guaranteed by design, not tested.
TIMING DIAGRAMS
tSR
CS
tSF
tCS
tSFS
1
2
3
4
5
6
15
16
SCLK
tDAV
MSB
DB14
DB13
tDSU
DIN
R/W
A6
DB12
DB11
A4
A3
DB10
DB2
DB1
LSB
tDHD
A5
A2
D2
D1
07980-002
DOUT
LSB
Figure 2. SPI Timing and Sequence
tSTALL
07980-003
CS
SCLK
Figure 3. DIN Bit Sequence
Rev. 0 | Page 5 of 20
ADIS16220
ABSOLUTE MAXIMUM RATINGS
Table 4. Package Characteristics
Table 3.
Parameter
Acceleration
Any Axis, Unpowered
Any Axis, Powered
VDD to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Analog Inputs to GND
Operating Temperature Range
Storage Temperature Range
Rating
Package Type
16-Terminal LGA
2000 g
2000 g
−0.3 V to +6.0 V
−0.3 V to +5.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to +3.6 V
−40°C to +125°C
−65°C to +125°C
ESD CAUTION
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rev. 0 | Page 6 of 20
θJA
250°C/W
θJC
25°C/W
Device Weight
0.6 g
ADIS16220
12
13
AIN2
11
VDD
14
NC
10
AIN1
15
NC
9
VREF
16
1
SCLK
GND
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
RST
DIN
3
CS
4
DOUT
2
PIN 1
INDICATOR
ADIS16220
TOP
LOOK THROUGH
VIEW
(Not to Scale)
7
8
NC
NOTES
1. NC = NO CONNECT.
2. THIS IS NOT AN ACTUAL TOP VIEW, BECAUSE THE PINS ARE NOT VISIBLE FROM THE TOP. THIS IS
A LAYOUT VIEW THAT REPRESENTS THE PIN CONFIGURATION IF THE PACKAGE IS LOOKED
THROUGH FROM THE TOP. THIS CONFIGURATION IS PROVIDED FOR PCB LAYOUT PURPOSES.
07980-005
6
NC
DIO1
5
DIO2
A
Figure 4. Pin Configuration
Table 5. Pin Function Descriptions
Pin No.
1
2
3
4
5
6
7, 8, 10, 11
9
12
13
14
15
16
1
2
Type1
I
O2
I
I
I/O
I/O
N/A
I
I
S
I
O
S
Mnemonic
SCLK
DOUT
DIN
CS
DIO1
DIO2
NC
RST
AIN2
VDD
AIN1
VREF
GND
Description
SPI, Serial Clock.
SPI, Data Output.
SPI, Data Input.
SPI, Chip Select.
Digital Input/Output.
Digital Input/Output.
No Connect.
Reset, Active Low.
Analog Input Channel 2.
Power Supply, 3.3 V.
Analog Input Channel 1.
Voltage Reference for AIN1 and AIN2.
Ground.
S = supply; O = output; I = input; I/O = input/output.
DOUT is an output when CS is low. When CS is high, DOUT is in a three-state, high impedance mode.
RECOMMENDED PAD LAYOUT
2.6955
8×
4.1865
8×
0.670
12×
8.373
2×
5.391
4×
9.2mm × 9.2mm STACKED LGA PACKAGE
Figure 5. Recommended of a Pad Layout
Rev. 0 | Page 7 of 20
07980-006
0.500
16×
1.127
16×
ADIS16220
THEORY OF OPERATION
ANCHOR
MOVABLE
FRAME
FIXED
PLATES
UNIT SENSING
CELL
AIN
SIGNALS
SPI SIGNALS
CONTROL
REGISTERS
CLOCK
Figure 7. Simplified Sensor Signal Processing Diagram
USER INTERFACE
SPI Interface
The user registers control operation and manage user access to
both sensor data and configuration inputs. Each 16-bit register
has its own unique bit assignment and has two addresses: one for
its upper byte and one for its lower byte. Table 8 provides a
memory map for each register, along with their function and
lower byte address. Each data collection and configuration
commands both use the SPI, which consists of four wires. The
chip select (CS) signal activates the SPI interface and the serial
clock (SCLK) synchronizes the serial data lines. Input commands
clock into the DIN pin, one bit at a time, on the SCLK rising
edge, and output data clocks out of the DOUT pin on the SCLK
falling edge. As a SPI slave device, the DOUT contents reflect
the information requested using a DIN command.
Figure 6. MEMS Sensor Diagram
DATA SAMPLING AND PROCESSING
The analog acceleration signal feeds into an analog-to-digital
(ADC) converter stage, which passes digitized data into the
controller. The controller processes the acceleration data, stores
it in the capture buffer, and manages access to it using the
SPI/register user interface. Processing options include offset
adjustment, filtering, and checking for preset alarm conditions.
The user registers provide addressing for all input/output operations on the SPI interface. The control registers use a dual memory
structure. The SRAM controls operation while the part is on, and
facilitates all user configuration inputs. The flash memory provides nonvolatile storage for control registers that have flash
backup (see Table 8). Storing configuration data in the flash
memory requires a manual, flash update command (GLOB_
CMD[12] = 1, DIN = 0xBF10). When the device powers on or
resets, the flash memory contents load into the SRAM, and then
the device starts producing data according to the configuration
in the control registers.
MANUAL
FLASH
BACKUP
NONVOLATILE
FLASH MEMORY
VOLATILE
SRAM
(NO SPI ACCESS)
SPI ACCESS
START-UP
RESET
Figure 8. SRAM and Flash Memory Diagram
Rev. 0 | Page 8 of 20
07980-109
ANCHOR
CONTROLLER
Dual Memory Structure
UNIT
FORCING
CELL
MOVING
PLATE
07980-004
ACCELERATION
PLATE
CAPACITORS
ADC
07980-007
Digital vibration sensing in the ADIS16220 starts with a widebandwidth MEMS accelerometer core that provides a linear
motion-to-electrical transducer function. Figure 6 provides a
basic physical diagram of the sensing element and its response
to linear acceleration. It uses a fixed frame and a moving frame
to form a differential capacitance network that responds to
linear acceleration. Tiny springs tether the moving frame to the
fixed frame and govern the relationship between acceleration
and physical displacement. A modulation signal on the moving
plate feeds through each capacitive path into the fixed frame
plates and into a demodulation circuit, which produces the
electrical signal that is proportional to the acceleration acting on
the device.
TEMP
SENSOR
OUTPUT
REGISTERS
SPI PORT
SENSING ELEMENT
CAPTURE
BUFFER
MEMS
SENSOR
SPI PORT
The ADIS16220 is a wide-bandwidth, digital acceleration sensor
for vibration analysis. This sensing system collects data
autonomously and makes it available to any processor system
that supports a 4-wire serial peripheral interface (SPI).
ADIS16220
BASIC OPERATION
1
SCLK
MOSI
3
DIN
MISO
2
DOUT
IRQ1
5
DIO1
IRQ2
6
DIO2
7
6
5
4
3
2
07980-010
DIN
SPI READ COMMANDS
A single register read requires two 16-bit SPI cycles, which also
use the bit assignments in Figure 13. The first sequence sets
R/W = 0 and communicates the target address (A6:A0). For a
read request, D7:D0 are don’t care bits. For simplicity, set D7:D0
equal to zero during read request commands. DOUT clocks out
during the second sequence. The second sequence can also use
DIN to setup the next read. Figure 12 provides a signal diagram
for all four SPI signals while reading the acceleration capture
buffer (CAPT_BUFA) in a repeating pattern. In this diagram,
DIN = 0x1400 and DOUT reflects the CAPT_BUFA register
contents.
Function
Slave select
Interrupt request inputs
Master output, slave input
Master input, slave output
Serial clock
The ADIS16220 SPI interface supports full duplex serial
communication (simultaneous transmit and receive) and uses
the bit sequence shown in Figure 13. Table 7 provides a list of
the most common settings that require attention to initialize a
processor’s serial port for the ADIS16220 SPI interface.
CS
Table 7. Generic Master Processor SPI Settings
SCLK
Description
ADIS16220 operates as a slave
Bit rate setting
Clock polarity/phase (CPOL = 1, CPHA = 1)
Bit sequence
Shift register/data length
DIN = 0001 0100 0000 0000 = 0x1400
DIN
DOUT
DOUT = 1111 1001 1101 1010 = 0xF9DA = –1573 LSBs ≥ –30.002g
Figure 12. Example SPI Read, Second 16-Bit Sequence
The user registers in Table 8 govern all data collection and
configuration. Figure 10 provides a generic bit assignment when
referencing each registers’ bit descriptions.
CS
SCLK
R/W
DB15
A6
A5
A4
A3
A2
A1
DB14 DB13 DB12 DB11 DB10 DB9
A0
D7
D6
D5
D4
D3
D2
D1
D0
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
NOTES
1. DOUT BITS ARE BASED ON THE PREVIOUS 16-BIT SEQUENCE (R/W = 0).
Figure 13. Example SPI Read Sequence
Rev. 0 | Page 9 of 20
R/W
DB15
A6
A5
DB14 DB13
07980-111
DOUT
0
Figure 11. SPI Sequence for Manual Capture Start (DIN = 0xBF08)
Table 6. Generic Master Processor Pin Names and Functions
DIN
1
LOWER BYTE
SCLK
Figure 9. Electrical Hook-Up Diagram
Processor Setting
Master
SCLK Rate ≤ 2.25 MHz
SPI Mode 3 (1, 1)
MSB-First
16-Bit
8
CS
16
Pin Name
SS
IRQ1, IRQ2
MOSI
MISO
SCLK
9
07980-112
SCLK
10
The control registers in Table 8 provide configuration options for
a variety of functions. A master processor writes to the registers,
one byte at a time, using simple firmware commands and the bit
assignments in Figure 13. Because each byte in a register is
independent, some functions only require one write cycle. For
example, set GLOB_CMD[11] = 1 (DIN = 0xBF08) to start a
manual capture sequence. The manual capture starts immediately after the last bit clocks into DIN (16th SCLK rising edge).
SPI SLAVE
CS
11
SPI WRITE COMMANDS
13
4
12
Figure 10. Generic Register Bit Definitions
ADIS16220
SS
13
UPPER BYTE
VDD
SYSTEM PROCESSOR
SPI MASTER
14
07980-212
VDD
15
07980-110
The ADIS16220 uses a serial peripheral interface (SPI) for
communication, which enables a simple connection with a
compatible, embedded processor platform, as shown in Figure 9.
The two general-purpose lines provide options for a busy indicator, an alarm indicator, a general-purpose input/output function,
and an external capture trigger input.
ADIS16220
Note that all registers in Table 8 consist of two bytes. All unused memory locations are reserved for future use.
Table 8. User Register Memory Map
Name
FLASH_CNT
ACCL_NULL
AIN1_NULL
AIN2_NULL
Access
Read only
Read/write
Read/write
Read/write
Flash
Backup
Yes
Yes
Yes
Yes
CAPT_SUPPLY
CAPT_TEMP
CAPT_PEAKA
CAPT_PEAK1
CAPT_PEAK2
CAPT_BUFA
CAPT_BUF1
CAPT_BUF2
CAPT_PNTR
CAPT_CTRL
CAPT_PRD
ALM_MAGA
ALM_MAG1
ALM_MAG2
ALM_MAGS
ALM_CTRL
Read only
Read only
Read only
Read only
Read only
Read only
Read only
Read only
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
GPIO_CTRL
MSC_CTRL
DIO_CTRL
AVG_CNT
Read/write
Read/write
Read/write
Read/write
Yes
Yes
Yes
Yes
DIAG_STAT
GLOB_CMD
ST_DELTA
Read only
Write only
Read only
Yes
No
Yes
LOT_ID1
LOT_ID2
PROD_ID
SERIAL_NUM
Read only
Read only
Read only
Read only
Yes
Yes
Yes
Yes
1
Address1
0x00
0x02
0x04
0x06
0x08 to 0x09
0x0A
0x0C
0x0E
0x10
0x12
0x14
0x16
0x18
0x1A
0x1C
0x1E
0x20
0x22
0x24
0x26
0x28
0x2A to 0x31
0x32
0x34
0x36
0x38
0x3A to 0x3B
0x3C
0x3E
0x40
0x42 to 0x51
0x52
0x54
0x56
0x58
Default
N/A
0x0000
0x0000
0x0000
0x8000
0x8000
0x8000
0x8000
0x8000
0x8000
0x8000
0x8000
0x0000
0x0020
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0003
0x000F
0x0000
0x0000
N/A
N/A
N/A
N/A
0x3F5C
N/A
Function
Status, flash memory write count
Control, acceleration offset adjustment control
Control, AIN1 offset adjustment control
Control, AIN2 offset adjustment control
Reserved
Output, power supply during capture
Output, temperature during capture
Output, peak acceleration during capture
Output, peak AIN1 level during capture
Output, peak AIN2 level during capture
Output, capture buffer for acceleration
Output, capture buffer for AIN1
Output, capture buffer for AIN2
Control, capture buffer address pointer
Control, capture control register
Control, capture period (automatic mode)
Control, Alarm A, acceleration peak threshold
Control, Alarm 1, AIN1 peak threshold
Control, Alarm 2, AIN2 peak threshold
Control, Alarm S, peak threshold
Control, alarm configuration register
Reserved
Control, general I/O configuration
Control, self-test control, AIN configuration
Control, digital I/O configuration
Control, filter configuration
Reserved
Status, system status
Control, system commands
Status, self-test response
Reserved
Date code identification
Date code identification
Product identifier; convert to decimal = 16220
Serial number
Bit
Assignments
Table 35
Table 25
Table 26
Table 26
Table 10
Table 10
Table 10
Table 10
Table 10
Table 10
Table 10
Table 10
Table 9
Table 15
Table 16
Table 19
Table 20
Table 20
Table 21
Table 18
Table 28
Table 30
Table 27
Table 24
Table 29
Table 23
Table 31
Table 32
Table 33
N/A
Table 34
Each register contains two bytes. The address of the lower byte is displayed. The address of the upper byte is equal to the address of the lower byte, plus 1.
Rev. 0 | Page 10 of 20
ADIS16220
DATA COLLECTION
Table 10. Capture Output Register Formats
The ADIS16220 samples and stores acceleration (vibration) and
analog input signal data using capture events. A capture event
involves several sampling/processing operations, as shown in
Figure 14. First, the ADIS16220 produces and stores 1024
samples of acceleration and analog input channel data into
the capture buffers. Second, the capture event takes a 5.12 ms
record of power supply measurements at a sample rate of
50 kHz and loads the average of this record into the CAPT_
SUPPLY register. Third, the capture event takes 64 samples of
internal temperature data over a period of 1.7 ms and loads the
average of this record into CAPT_TEMP.
Register
CAPT_SUPPLY
CAPT_TEMP
CAPT_BUFA,
CAPT_PEAKA
CAPT_BUF1,
CAPT_BUF2,
CAPT_PEAK1,
CAPT_PEAK2
1
DATA IN BUFFERS LOAD INTO
USER OUTPUT REGISTERS
CAPT_BUF1
CAPT_BUFA
AIN1
CAPTURE
BUFFER
ACCELEROMETER
CAPTURE
BUFFER
TRIPLE-CHANNEL
CAPTURE BUFFER
1024 SAMPLES
EACH
16-BIT DATA
1
1023
Table 11
Table 12
LSB
+3670
+1
0
−1
−3670
Hex
0x0E56
0x0001
0x0000
0xFFFF
0xF1AA
Output (Binary)
0000 1110 0101 0111
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 0001 1010 1010
This table also applies to the CAPT_PEAKA register.
Table 12. CAPT_BUF11 Data Format Examples
INTERNAL SAMPLING SYSTEM FILLS THE CAPTURE BUFFER
AND OUTPUT REGISTERS
CAPT_TEMP
07980-014
CAPT_SUPPLY
Figure 14. Acceleration Capture Buffer Structure and Operation;
CAPT_BUF1 (AIN1) and CAPT_BUF2 (AIN2) Use Similar Structures
READING DATA FROM THE CAPTURE BUFFER
When a capture is complete, the first data samples load into the
CAPT_BUFx registers and 0x0000 loads into the index pointer
(CAPT_PNTR). The index pointer determines which data samples load into the CAPT_BUFx registers. For example, writing
0x0138 to the CAPT_PNTR register (DIN = 0x9A38, DIN =
0x9B01) causes the 313th sample in the buffer memory to load
into the CAPT_BUFx registers.
Table 9. CAPT_PNTR Bits Descriptions
Bit
[15:10]
[9:0]
Table 14
12-bit data formats are LSB justified. Upper four bits are not used in these cases.
Acceleration (g)
+70
+0.019073
0
−0.019073
−70
0
AIN2
CAPTURE
BUFFER
Reference
Table 13
Table 11. CAPT_BUFA1 Data Format Examples
CAPT_BUF2
CAPT_PNTR
Format1
12-bit binary, 0 V = 0 LSB,
1.2207 mV/LSB
12-bit binary, +25°C = 1278 LSB,
−0.47°C/LSB
16-bit twos complement
19.073 mg/LSB
16-bit twos complement
305.18 μV/LSB
Description (Default = 0x0000)
Reserved
Data bits
Table 10 offers a summary of the data format used by each
output registers. Table 11, Table 12, Table 13, and Table 14
provide example output coding for each register.
1
2
LSB
+3277
+1
0
−1
−3277
Hex
0x0CCD
0x0001
0x0000
0xFFFF
0xF333
Output (Binary)
0000 1100 1100 1101
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 0011 0011 0011
This table also applies to CAPT_BUF2, CAPT_PEAK1, and CAPT_PEAK2
registers.
This applies for MSC_CTRL = 0x0003. When MSC_CTRL = 0x0000, substitute
3300 mV for VDD.
Table 13. CAPT_SUPPLY Data Format Examples
Supply Level (V)
3.6
3.3 + 0.0012207
3.3
3.3 – 0.0012207
3.15
LSB
2949
2704
2703
2702
2580
Hex
0xB85
0xA90
0xA8F
0xA8E
0xA14
Binary Output
1011 1000 0101
1010 1001 0000
1010 1000 1111
1010 1000 1110
1010 0001 0100
Table 14. CAPT_TEMP Data Format Examples
The index pointer automatically increments with a CAPT_BUFA,
CAPT_BUF1, or CAPT_BUF2 read command, which causes
the next set of capture data to load into each capture buffer
register.
Output Data Format
Level (mV)2
VDD/2+1000
VDD/2+0.305
VDD/2
VDD/2−0.305
VDD/2−1000
Temperature (°C)
+125
+25.47
+25
+24.53
−40
Rev. 0 | Page 11 of 20
LSB
1065
1277
1278
1279
1416
Hex
0x429
0x4FD
0x4FE
0x4FF
0x588
Binary Output
0100 0100 1001
0100 1111 1101
0100 1111 1110
0100 1111 1111
0101 1000 1000
ADIS16220
CAPTURE MODE CONFIGURATION
The CAPT_CTRL register (see Table 15) offers three modes of
capture operation (manual, automatic, and event), along with a
number of configuration features for supporting these modes.
All three modes use the start/stop bit, located in GLOB_
CMD[11] (see Table 23) to manage the capture operation.
Table 17. Example Automatic Mode Configuration Sequence
DIN
0x9F02,
0x9E18
0x9C06
0xBF08
Description
CAPT_PRD[15:8] = 0x02, set time scale to hours
CAPT_PRD[7:0] = 0x18, set the capture period to 24 hours
Set the device for trigger mode and enable shutdown
Start: device executes a capture and shuts down
Table 15. CAPT_CTRL Bit Descriptions
Event Capture Mode
Bit
[15:7]
[6]
The event mode functions in a manner similar to a single-event
trigger on a digital oscilloscope. This mode is useful for capturing shock events and for preshock motion/vibration analysis.
Once started, it monitors a continuous stream of real-time data for
a preset, event trigger condition. The event trigger settings are in
the following registers: ALM_CTRL (see Table 18), ALM_MAGA
(see Table 19), and ALM_MAG1/ALM_MAG2 (see Table 20).
When the acceleration or analog input signals trip the alarm
trigger settings, the device fills the capture buffers with pretrigger and post-trigger data, according to the pre-trigger
configuration in CAPT_CTRL[5:4].
[5:4]
[3:2]
[1]
[0]
Description (Default = 0x0020)
Reserved
Automatically store capture buffers to flash upon alarm
trigger (1 = enabled)
Pre-event capture length for event mode
00 = 64 samples
01 = 128 samples
10 = 256 samples
11 = 512 samples
Capture mode
00 = manual: use GLOB_CMD[11] to start capture
01 = automatic: use CAPT_PRD[9:0] to set capture period
10 = event: continuously monitor data for the conditions
set in ALM_CTRL, ALM_MAGA, ALM_MAG1, and ALM_MAG2.
11 = not used
Power-down between capture events
1 = enabled, which requires CS toggle to wake up
Reserved
Manual Capture Mode
The factory default configuration for capture mode is the manual
mode. In the manual mode, the ADIS16220 waits for a start
command to execute the capture event. Set GLOB_CMD[11] =
1 (DIN = 0xBF08) to start a capture in this mode. Once the
capture process begins, GLOB_CMD[11] resets to zero and
serves as a stop bit, until the capture event completes. Set
GLOB_CMD[11] = 1 to stop a capture event that is in progress.
Configuring the device in the event capture mode requires
four steps:
1.
2.
3.
4.
Select which data channels to enable using ALM_CTRL.
Set each threshold using the ALM_MAGx registers.
Select event capture mode by setting CAPT_CTRL[3:2] = 10.
Start the sampling by setting GLOB_CMD[11] = 1. Table 22
provides an example for configuring the device in this
mode. After the continuously sampling starts, setting
GLOB_CMD[11] = 1 stops the sampling process.
Table 18. ALM_CTRL Bit Descriptions
Bit
[15:6]
[5]
Automatic Capture Mode
Description (Default = 0x0000)
Reserved
System alarm comparison polarity
1 = trigger when less than ALM_MAGS[11:0]
0 = trigger when greater than ALM_MAGS[11:0]
System alarm trigger source
1 = temperature, 0 = power supply
System alarm enable (ALM_MAGS)
1 = enabled, 0 = disabled
AIN2 alarm enable (ALM_MAG2)
1 = enabled, 0 = disabled
AIN1 alarm enable (ALM_MAG1)
1 = enabled, 0 = disabled
Acceleration alarm enable (ALM_MAGA)
1 = enabled, 0 = disabled
In the automatic mode, the ADIS16220 executes capture events
periodically, according to the time in CAPT_PRD (see Table 16).
Table 17 provides an example for configuring and starting the
automatic mode. When the device receives the start command,
it executes a capture event, and then starts the countdown for
executing the next capture event. Once the automatic mode
starts, GLOB_CMD[11] becomes a stop bit.
[4]
Table 16. CAPT_PRD Register Bit Descriptions
[0]
Bit
[15:10]
[9:8]
Table 19. ALM_MAGA Bit Descriptions
[7:0]
Description (Default = 0x0000)
Reserved
Scale
00 = 1 second/LSB
01 = 1 minute/LSB
10 = 1 hour/LSB
Data bits, binary format
[3]
[2]
[1]
Bit
[15:0]
Rev. 0 | Page 12 of 20
Description (Default = 0x0000)
Data bits for acceleration threshold setting;
twos complement, 19.073 mg/LSB.
Range = +8191 LSBs/−8192 LSBs.
ADIS16220
Table 20. ALM_MAG1 and ALM_MAG2 Bit Descriptions
See Table 24 for the AVG_CNT setting.
Table 21. ALM_MAGS Bit Descriptions
Bit
[15:12]
[11:0]
Description (Default = 0x0000)
Reserved.
Data bits for temperature or supply threshold setting.
Binary format matches CAPT_TEMP or CAPT_SUPPLY
format, depending on the ALM_CTRL[4] setting.
Each ALM_MAGx register has a corresponding error flag in the
DIAG_STAT register for software monitoring of alarm
conditions. Note that the system alarm in the ALM_MAGS
register (see Table 21) has an error flag in DIAG_STAT[11] but
cannot trigger a data capture.
Table 22. Example Event Mode Configuration Sequence
DIN
0xA00C,
0xA102
0xA809
0xB61F
0x9C5A
0xBF08
1
 1024  2 AVG _ CNT (no flash)
97,184
1
TC  0.516 
 1024  2 AVG _ CNT (with flash)
97,184
TC  0.014 
Description (Default = 0x0000)
Data bits for AIN1, AIN2 signal threshold setting;
twos complement, 305.18 μV/LSB.
Range = +8191 LSBs/−8192 LSBs.
Description
Set acceleration trigger point at >+10 g and <−10 g by
setting ALM_MAGA = 0x020C.
Set the system alarm as a greater-than-temperature
configuration and enable both acceleration and system
alarms by setting ALM_CTRL[7:0] = 0x09.
Keep DIO1 as a busy indicator and set DIO2 as a positive
alarm indicator by setting DIO_CTRL[7:0] = 0x1F.
Set capture into event mode, enable automatic capture
store to flash, enable power-down between captures,
and set pre-event capture length to 128 samples by
setting CAPT_CTRL[7:0] = 0x5A.
Start the event capture mode by setting GLOB_CMD[11] = 1
Power-Down Control
CAPT_CTRL[1] provides an option to automatically power
down the device after a capture event to reduce power consumption. Wake the device from power-down by lowering CS. The
timer in automatic mode can wake the device up as well. Allow
for a 2 ms wake-up time after lowering CS to wake the device
up. Communication with the device while in sleep mode wakes
up the device. The device remains awake until after the next
capture or until the device is manually put back to sleep. When
data is extracted after a capture, the user can command the
device to go back to sleep by setting GLOB_CMD[1] = 1 (DIN
= 0xBE02). When waking multiple devices, CS must occur at
different times to avoid conflicts on the DOUT line.
GLOBAL COMMANDS
The GLOB_CMD register provides an array of single-write
commands for convenience. Setting the assigned bit in Table 23
to 1 activates each function. When the function completes, the
bit restores itself to 0. For example, clear the capture buffers using
a single DIN write sequence, DIN = 0xBF01. All of the commands
in the GLOB_CMD register require the power supply to be
within normal limits for the execution times listed in Table 23.
The execution times reflect the factory default configuration
where applicable and describe the time required to return to
normal operation.
Table 23. GLOB_CMD Bit Descriptions
Bit
[15:14]
[13]
[12]
[11]
[10]
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
1
Description
Reserved
Restore capture data and settings
from flash memory
Copy capture data and settings to
flash memory
Capture mode start/stop
Set CAPT_PNTR = 0x0000
Reserved
Clear capture buffers
Software reset
Reserved
Flash test, compare sum of flash
memory with the sum of SRAM
Clear DIAG_STAT register
Factory setting restore
Self-test
Power-down, requires toggling CS
low to wake up
Autonull
Execution Time1
N/A
0.88 ms (no capture)
6.91 ms (with capture)
350 ms (no capture)
502 (with capture)
N/A
0.037 ms
N/A
0.84 ms
22.7 ms
N/A
10.5 ms
0.035 ms
335 ms
12 ms
N/A
678 ms
This indicates the typical duration of time between the command write and
the device returning to normal operation.
FILTERING
The ADIS16220 provides an averaging/decimation filter for
lower bandwidth applications that may value finer frequency
resolution using the 1024-sample capture buffer.
Automatic Flash Back-Up Control
CAPT_CTRL[6] provides an option for automatically storing
capture buffer data to a mirror location in the nonvolatile flash
memory at the end of a capture. When an alarm condition has
been met, the device also performs a system backup, which
stores the registers and capture buffers in flash memory. Set
GLOB_CMD[13] = 1 (DIN = 0xBF40) to recover these settings
from the flash memory.
MEMS
SENSOR
Rev. 0 | Page 13 of 20
ADC
AVERAGING
FILTER
N
+
÷N
POWER
SUPPLY
COMPENSATION
OFFSET
NULL
REGISTER
Figure 15. Simplified Signal Processing Flowchart
TO
CAPTURE
MEMORY
AND
OUTPUT
REGISTERS
07980-009
Bit
[15:0]
Use the following equations to estimate capture times:
ADIS16220
AVG_CNT[3:0] controls the averaging/decimating filter
structure in binomial steps, starting with 1 and ending with
1024. For example, set AVG_CNT[7:0] = 0x08 (DIN = 0xB608)
to select 256 averages and a decimation rate of 1/256. Note that
the decrease in sample time impacts the total capture time (TC):
Table 27. DIO_CTRL Bit Descriptions
Bit
[15:6]
[5:4]
AVG_CNT[7:0] = 0x08 = 8, N = 28 = 256 averages
Table 24. AVG_CNT Bit Descriptions
Bit
[15:4]
[3:0]
Description (Default = 0x0000)
Reserved
Power-of-two setting for number of averages, binary
[3:2]
OFFSET ADJUSTMENT
The ACCL_NULL, AIN1_NULL, and AIN2_NULL registers
provide a bias adjustment function. For example, setting
ACCL_NULL = 0x009D (DIN = 0x829D) increases the acceleration bias by 157 LSB (3 g). Set GLOB_CMD[0] = 1 (DIN =
0x3E01) to execute the autonull function, which loads the
offset registers with a value derived from a 678 ms average of
the acceleration data.
[1]
[0]
Table 28. GPIO_CTRL Bit Descriptions
Table 25. ACCL_NULL Bit Descriptions
Table 26. AIN1_NULL and AIN2_NULL Bit Descriptions
Bit
[15:10]
[9]
[8]
[7:2]
[1]
Bit
[15:0]
[0]
Bit
[15:0]
Description (Default = 0x000F)
Reserved
DIO2 function selection
00 = general-purpose I/O (use GPIO_CTRL)
01 = alarm indicator output (per ALM_CTRL)
10 = capture trigger inputs
11 = busy indicator output
DIO1 function selection
00 = general-purpose I/O (use GPIO_CTRL)
01 = alarm indicator output (per ALM_CTRL)
10 = capture trigger inputs
11 = busy indicator output
DIO2 line polarity; if [5:4] = 00, see GPIO_CTRL
1 = active high
0 = active low
DIO1 line polarity; if [3:2] = 00, see GPIO_CTRL
1 = active high
0 = active low
Description (Default = 0x0000)
Data bits, twos complement, 19.073 mg/LSB
sensitivity. See Figure 15 for impact on output.
Range = +8191 LSBs/−8192 LSBs
Description (Default = 0x0000)
Data bits, twos complement, 305.18 μV/LSB
sensitivity. Signal path is similar to Figure 15.
Range = +8191 LSBs/−8192 LSBs
Description (Default = 0x0000)
Reserved
General-purpose I/O output level, DIO2
General-purpose I/O output level, DIO1
Reserved
General-purpose I/O Line, data direction control, DIO2
1 = output, 0 = input
General-purpose I/O Line, data direction control, DIO1
1 = output, 0 = input
INPUT/OUTPUT FUNCTIONS
DIAGNOSTICS
DIO1 and DIO2 are configurable as I/O lines that serve multiple purposes. The following register priority governs their
operation: DIO_CTRL, then GPIO_CTRL. The DIO_CTRL
register has four application-specific configuration options for
each signal. The capture trigger input option works in conjunction
with the manual capture mode and provides a hardware option
for driving a data capture event. When enabled, this function
searches for a positive pulse and the capture starts on the falling
edge of this pulse. The busy indicator output is active during
capture events and can help prevent undesirable interruptions.
For example, set DIO_CTRL[5:0] = 101111 (DIN = 0xB62F) to
establish DIO2 as a capture trigger input and keep DIO1 as a
positive polarity, busy indicator output. Using the busy indicator
as an interrupt driver enables the master processor to gather
capture data as soon as it is available, without having to poll
inputs or estimate execution times. The alarm indicator output
is active when the trigger set by ALM_CTRL and ALM_MAGx
activates. When configured as general-purpose lines, the
GPIO_CTRL register configures DIO1 and DIO2. For example,
set GPIO_CTRL = 0x0103 (DIN = 0xB203, then 0xB301) to set
DIO1 and DIO2 as outputs, with DIO1 in a 1 state and DIO2 in
a 0 state.
In all of the error flags in DIAG_STAT, a 1 identifies an error
condition, whereas a 0 signals normal operation. All of the flags
remain until the next capture or reset command (GLOB_CMD[4]
= 1). DIAG_STAT[1:0] returns to 1 after the next sample (or
capture) if the error conditions still exist. DIAG_STAT[14:12]
provide flags to check the source of an event capture, prior to
reading the entire capture buffer. DIAG_STAT[10:8] offers flags
that check the peak values in the capture against the conditions
in the ALM_CTRL and ALM_MAGx registers. The flash test
produces an error flag in DIAG_STAT[6] to check if the sum of
the internal operating memory matches the sum of the same
flash memory locations. The capture period violation flag
(DIAG_STAT[4]) rises to 1 when the user attempts to use the
SPI while a capture sequence is in progress. Using the DIO1 line
in the factory default configuration as a busy indicator can help
prevent this violation. The SPI communication flag in
DIAG_STAT[3] raises to a Logic 1 when the total number of
SCLK clocks is not a multiple of 16 during a SPI transfer.
Rev. 0 | Page 14 of 20
ADIS16220
Table 29. DIAG_STAT Bit Descriptions
Bit
[15]
[14]
[13]
[12]
[11]
[10]
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
Description (Default = 0x0000)
Reserved
AIN2 sample > ALM_MAG2
AIN1 sample > ALM_MAG1
Acceleration sample > ALM_MAGA
Error condition programmed into ALM_MAGS[11:0] and
ALM_CTRL[5:4] is true
|Peak value in AIN2 data capture| > ALM_MAG2
|Peak value in AIN1 data capture| > ALM_MAG1
|Peak value in acceleration data capture| > ALM_MAGA
Data ready, capture complete
Flash test result, checksum flag
Self-test diagnostic error flag
Capture period violation/interruption
SPI communications failure
Flash update failure
Power supply above 3.625 V
Power supply below 3.15 V
Self-Test
The internal MEMS sensing element has an electrostatic selftest function that simulates the physical displacement associated
with an acceleration event. There are two options for using this
feature to verify the integrity of the accelerometer sensor and signal
chain. Set GLOB_CMD[2] = 1 to execute an automatic self-test
sequence, which exercises the sensing element, observes the
change in output, records it into ST_DELTA, compares it with preset minimum/maximum values, and reports the pass/fail result in
DIAG_STAT[5].
Another option is to set MSC_CTRL[8] = 1 (see Table 30) to
manually activate the sensing element. Then execute a manual
capture, which reflects the response associated with the self-test
setting.
MSC_CTRL[1:0] provides an option for reducing the sensitivity
dependence on power supply for ratiometric sensors, such as
the ADXL001.
Table 31. ST_DELTA Bit Descriptions
Bit
[15:0]
Description
Acceleration data, twos complement, 19.073 mg/LSB
SERIALIZATION
LOT_ID1 and LOT_ID2 combine to provide a unique lot code
that is 24 bits in length. SERIAL_NUM provides a unique serial
number for each device within a given lot.
Table 32. LOT_ID1 Bit Descriptions
Bit
[15:8]
[7:0]
Description
Lot identification code, least significant byte
Reserved for internal use, do not use
Table 33. LOT_ID2 Bit Descriptions
Bit
[15:0]
Description
Lot identification code, most significant bytes
Table 34. SERIAL_NUM Bit Descriptions
Bit
[15:0]
Description
Serial number, lot-specific
FLASH MEMORY MANAGEMENT
The FLASH_CNT register (see Table 35) provides a tool for
managing the flash memory’s endurance. The FLASH_CNT
register increments every time there is a write to the flash
memory. Figure 16 quantifies the relationship between data
retention and junction temperature.
Table 35. FLASH_CNT Bit Descriptions
Bit
[15:0]
Description
Binary counter for writing to flash memory
Table 30. MSC_CTRL Bit Descriptions
[0]
600
450
300
150
0
07980-113
[7:2]
[1]
Description (Default = 0x0003)
Reserved
Self-test enable, set to 1 to activate,
(returns to 0 when complete)
Reserved
Power supply compensation, AIN2
1 = enable, 0 = disable
Power supply compensation, AIN1
1 = enable, 0 = disable
RETENTION (Years)
Bit
[15:9]
[8]
30
40
55
70
85
100
125
JUNCTION TEMPERATURE (°C)
Figure 16. Flash/EE Memory Data Retention
Rev. 0 | Page 15 of 20
135
150
ADIS16220
APPLICATIONS INFORMATION
ASSEMBLY
INTERFACE BOARD
When developing a process flow for installing ADIS16220 devices
on PCBs, see the JEDEC standard document J-STD-020C for
reflow temperature profile and processing information. The
ADIS16220 can use the Sn-Pb eutectic process and the Pb-free
eutectic process from this standard. See JEDEC J-STD-033 for
moisture sensitivity level (MSL) handling requirements. The
MSL rating for these devices is marked on the antistatic bags,
which protect these devices from ESD during shipping and
handling. Prior to assembly, review the process flow for information about introducing shock levels that exceed the absolute
maximum ratings for the ADIS16220. PCB separation and
ultrasonic cleaning processes can introduce high levels of shock
and can damage the MEMS element. Bowing or flexing the PCB
after solder reflow can also place large pealing stress on the pad
structure and can damage the device. If this is unavoidable,
consider using an underfill material to help distribute these
forces across the bottom of the package. Tasca
The ADIS16220/PCBZ provides the ADIS16220 function
on a 1.2 inch × 1.3 inch printed circuit board (PCB), which
simplifies the connection to an existing processor system.
The four mounting holes accommodate either M2 (2mm) or
Type 2-56 machine screws. These boards are made of IS410
material and are 0.063 inches thick. The second level assembly
uses a SAC305-compatible solder composition (Pb-free), which
has a presolder reflow thickness of approximately 0.005 inches.
The pad pattern on the ADIS16220/PCBZ matches that shown in
Figure 5. J1 and J2 are dual-row, 2 mm (pitch) connectors that
work with a number of ribbon cable systems, including 3M Part
Number 152212-0100-GB (ribbon-crimp connector) and 3M Part
Number 3625/12 (ribbon cable).
J1/J2 PIN NUMBERS
GETTING STARTED QUICKLY
J1
4
1
5
6
2
7
8
3
9
10
4
11
12
6
ADIS16220CCCZ
9
1
4
2
3
10
13
11
J2
RST
AIN1
SCLK
AIN2
CS
DIO2
DOUT
DIO1
NC
DIN
NC
VDD
NC
NC
12
16
VREF
GND
14
12
6
5
7
10
8
11
1
3
11
12
5
7
9
2
15
10
4
C1
6
7
8
8
07980-016
5
9
Figure 17. Electrical Schematic
spi_write(BF08h);
delay 30ms;
2
3
1.100
Once the ADIS16220 has a power supply voltage that reaches
3.15 V, it executes a start-up sequence that places the device in
manual capture mode. The following code example initiates a
manual data capture by setting GLOB_CMD[11] = 1 (DIN =
0xBF08) and reads all 1024 samples in the acceleration capture
buffer, using DIN = 0x1400. The data from the first spi_reg_
read is not valid because this command is starting the process.
The second spi_reg_read command (first read inside the
embedded For loop) produces the first valid data. This code
sequence produces CS, SCLK, and DIN signals similar to the
ones found in Figure 12.
1
1.050
2 × 0.925
Data(0) = spi_reg_read(14h);
J2
J1
For n = 0 to 1023
U1
2 × 0.673
iSensor
Data(n) = spi_reg_read(14h);
n = n + 1;
end
C1
4 × Ø0.087
M2×0.4
2 × 0.000
Figure 18. PCB Assembly View and Dimensions
Rev. 0 | Page 16 of 20
07980-017
0.865
2 × 0.900
0.035
2 × 0.000
0.200
0.150
ADIS16220
OUTLINE DIMENSIONS
5.391
BSC
(4×)
2.6955
BSC
(8×)
9.35
9.20 SQ
9.05
13
PIN 1
INDICATOR
1.000 BSC
(16×)
16
12
1
8.373
BSC
(2×)
0.797 BSC
(12×)
9
4
8
0.200
MIN
(ALL SIDES)
TOP VIEW
5
BOTTOM VIEW
0.373 BSC
(16×)
5.00
TYP
052609-C
3.90
MAX
SIDE VIEW
Figure 19. 16-Terminal Stacked Land Grid Array [LGA]
(CC-16-2)
Dimensions shown in millimeters
ORDERING GUIDE
Model1
ADIS16220CCCZ
ADIS16220/PCBZ
1
Temperature Range
−40°C to +125°C
Package Description
16-Terminal Stacked Land Grid Array [LGA]
Evaluation Board
Z = RoHS Compliant Part.
Rev. 0 | Page 17 of 20
Package Option
CC-16-2
ADIS16220
NOTES
Rev. 0 | Page 18 of 20
ADIS16220
NOTES
Rev. 0 | Page 19 of 20
ADIS16220
NOTES
©2009 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D07980-0-12/09(0)
Rev. 0 | Page 20 of 20
Similar pages