Micrel MIC94060YC6 High side power switch Datasheet

MIC94060/61/62/63
High Side Power Switches
General Description
Features
The MIC94060-63 are high-side load switches designed
for operation between 1.7V to 5.5V. The devices contain
a low on-resistance P-channel MOSFET that supports
over 2A of continuous current. The MIC94061 and
MIC94063 features an active load discharge circuit
which insures capacitive loads retain no charge when
the main switch is in an OFF state.
MIC94060-61 feature rapid turn on while MIC94062-63
provide a slew rate controlled Soft-Start turn-on of 800µs
(typical) to prevent in-rush current from glitching supply
rails.
An active pull-down on the enable input keeps
MIC94060-63 in a default OFF state until the EN pin is
pulled to a high level. Built-in level shift circuitry allows
low voltage logic signals to switch higher supply
voltages, or vice versa; high level logic signals can
control low level voltages.
MIC94060-63’s operating voltage range makes them
suitable for 1-cell Lithium ion and 2- to 3-cell
NiMH/NiCad/Alkaline powered systems, as well as, all
5V applications. Their low operating current of 2µA and
low shutdown current of <1µA maximize battery life.
Data sheets and support documentation can be found on
Micrel’s web site at: www.micrel.com.
•
•
•
•
•
•
•
•
•
1.7V to 5.5V input voltage range
2A continuous operating current
77mΩ (typ) RDSON
Built-in level shift for control logic; can be operated by
1.5V logic.
Low 2µA quiescent current
Soft-Start: MIC94062-63
Micro-power shutdown <1µA
Load discharge circuit: MIC94061, MIC94063
Space saving 1.2mm x 1.6mm Thin MLF® package
Applications
• Load switch in portable applications:
- Cellular phones
- PDAs
- MP3 players
- Digital Cameras
- Portable instrumentation
• Battery switch-over circuits
• Level translator
________________________________________________________________________________________________________
Typical Application
MIC94060, 62
Load Switch Application
MIC94061, 63
Load Switch with Capacitive Load Discharge
MLF and MicroLeadFrame are registered trademarks of Amkor Technologies, Inc.
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
July 2010
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Ordering Information
Part Marking(1)
Part Number
Standard
Pb-Free
MIC94060BC6
Soft-Start
Standard
Pb-Free
MIC94060YC6
P54
P54
MIC94061BC6
MIC94061YC6
P55
P55
MIC94062BC6
MIC94062YC6
P56
P56
●
MIC94063BC6
MIC94063YC6
P57
P57
●
—
MIC94060YMT
—
P54
—
MIC94061YMT
—
P55
—
MIC94062YMT
—
P56
●
—
MIC94063YMT
—
P57
●
Load Discharge
Package
●
SC-70-6
●
●
1.2mm x 1.6mm
® (2, 3)
Thin MLF
●
Notes
1.
Underbar symbol on SC-70 Pb-free packages may not be to scale.
2.
MLF ▲ = Pin 1 identifier.
3.
MLF is a GREEN RoHS compliant package. Lead finish is NiPdAu. Mold compound is Halogen Free.
®
®
Pin Configuration
1.2x1.6 mm Thin MLF® (MT)
SC-70-6 (C6)
Pin Description
Pin Number
Pin Name
Pin Function
SC-70
MLF
1
1
VOUT
Drain of P-channel MOSFET.
2,5
2
GND
Ground and the backside pad (MLF only) should both be connected to electrical ground.
4
3
VIN
Source of P-channel MOSFET.
3
4
EN
Enable (Input): Active-high CMOS compatible control input for switch A. Do not leave
floating.
6
--
NIC
No Internal Connection. A signal or voltage applied to this pin will have no effect on device
operation.
July 2010
2
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Absolute Maximum Ratings (1)
Operating Ratings (2)
Input Voltage (VIN) ................................................+6V
Enable Voltage (VEN) ...........................................+6V
Continuous Drain Current (ID) (3)
TA = 25°C ....................................................... ±2A
TA = 85°C ....................................................±1.4A
Pulsed Drain Current (IDP) (4) ................................ ±6A
Continuous Diode Current (IS) (4) .....................–50mA
Storage Temperature (Ts) ............... –55°C to +150°C
ESD Rating – HBM (6) .......................................... 4KV
Input Voltage (VIN)................................. +1.7 to +5.5V
Junction Temperature (TA).............. –40°C to +125°C
Package Thermal Resistance
SC-70-6 (θJA)......................................... 240°C/W
1.2x1.6 MLF (θJA) .................................. 172°C/W
1.2x1.6 MLF (θJC) (3) .............................. 134°C/W
Electrical Characteristics
VIN = 5V; TA = 25°C, bold values indicate –40°C< TA < +85°C, unless noted.
Symbol
Parameter
Condition
Min
VEN_TH
Enable Threshold Voltage
VIN = 1.8V to 4.5V, ID = –250μA
VIN = 1.7V to 4.5V, ID = –250μA
Typ
Max
Units
0.5
1.2
V
0.4
1.2
V
4
μA
1
μA
IEN
Enable Input Current
VIN = VEN = 5.5V
IVIN
OFF State Leakage Current
VIN = +5.5V, VEN = 0V
RDS(ON)
P-Channel Drain to Source
ON Resistance
VIN = +4.5V, ID = –100mA, VEN = 1.5V
77
110
mΩ
VIN = +3.6V, ID = –100mA, VEN = 1.5V
85
115
mΩ
VIN = +2.5V, ID = –100mA, VEN = 1.5V
100
140
mΩ
VIN = +1.8V, ID = –100mA, VEN = 1.5V
145
200
mΩ
VIN = +1.7V, ID = –100mA, VEN = 1.5V
155
215
mΩ
VIN = +4.5V, ID = –100mA, VEN = 1.5V
85
115
mΩ
VIN = +3.6V, ID = –100mA, VEN = 1.5V
100
140
mΩ
VIN = +2.5V, ID = –100mA, VEN = 1.5V
145
200
mΩ
VIN = +1.8V, ID = –100mA, VEN = 1.5V
155
215
mΩ
VIN = +1.7V, ID = –100mA, VEN = 1.5V
165
225
mΩ
VIN = +3.6V, ITEST = 1mA, VEN = 0V
200
300
Ω
Typ
Max
Units
0.85
1.5
μs
700
1200
μs
0.5
1
5
μs
500
800
1500
μs
SC-70 Package
RDS(ON)
P-Channel Drain to Source
ON Resistance
MLF Package
RSHUTDOWN
Turn-Off Resistance
2
MIC94061, 63
Dynamic
Symbol
Parameter
Condition
Min
tON_DLY
Turn-On Delay Time
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94060, 61
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94062, 63
tON_RISE
Turn-On Rise Time
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94060, 61
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94062, 63
July 2010
3
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Dynamic (Continued)
tOFF_DLY
Turn-Off Delay Time
VIN = +3.6V, ID = –100mA, VEN = 1.5V
100
200
ns
60
200
ns
60
100
ns
60
100
ns
MIC94060, 61
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94062, 63
tOFF_FALL
Turn-Off Fall Time
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94060, 61
VIN = +3.6V, ID = –100mA, VEN = 1.5V
MIC94062, 63
Notes:
1.
Exceeding the absolute maximum rating may damage the device.
2.
The device is not guaranteed to function outside its operating rating.
3.
With backside thermal contact to PCB.
4.
Pulse width <300μs with < 2% duty cycle.
5.
Continuous body diode current conduction (reverse conduction, i.e. VOUT to VIN) is not recommended.
6.
Devices are ESD sensitive. Handling precautions recommended. HBM (Human body model), 1.5kΩ in series with 100pF.
July 2010
4
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Typical Characteristics
July 2010
5
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Functional Characteristics
MIC94060
July 2010
6
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
MIC94061
July 2010
7
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
MIC94062
July 2010
8
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
MIC94063
July 2010
9
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Package Information
6-Pin SC-70 (C6)
4-Pin Thin MLF® (MT)
July 2010
10
M9999-070910-E
Micrel, Inc.
MIC94060/61/62/63
Recommended Land Pattern for MLF 1.2x1.6 4 Lead
Optional for maximum thermal performance. Heatsink should be connected to GND plane of PCB for maximum thermal performance.
Disclaimer: This is only a recommendation based on information available to Micrel from its suppliers. Actual land pattern may have to be
significantly different due to various materials and processes used in PCB assembly. Micrel makes no representation or warranty of
performance based on the recommended land pattern."
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its
use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product
can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant
into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A
Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully
indemnify Micrel for any damages resulting from such use or sale.
© 2004 Micrel, Incorporated.
July 2010
11
M9999-070910-E
Similar pages