Sharp GP2Y1001AU Compact dust sensor for air conditioner Datasheet

GP2Y1001AU
GP2Y1001AU
Compact Dust Sensor
for Air Conditioners
■ Features
■ Outline Dimensions
1. Compact, thin type (58×38×20.7mm)
2. Low dissipation current (Icc:MAX. 20mA)
3. Single-shot detection of house dust
(Unit : mm)
Model No.
2
58
■ Applications
Symbol
VCC
VLED
Topr
Tsol
29.1
Unit
V
V
°C
°C
6
*1 Open drain drive input
Connector
JAPAN SOLDRLESS
TERMINAL MSG. CO., LTD. S6B-ZR-SM3A
Unit
V
8.7
(15.7)
5
5
R2
5
Rating
12±1.8
1
16.3
Symbol
VCC
2
29.1
■ Recommend Operating Conditions
Parameter
Operating Supply voltage
φ10
Dust
through hole
22.7
(Ta=25°C)
Rating
−0.3 to +15
−0.3 to VCC
−10 to +65
−20 to +80
5
Parameter
Supply voltage
*1
Input terminal voltage
Operating temperature
Soldering temperature
20.7
■ Absolute Maximum Ratings
2
16.3
38
1. Air conditioners
2. Air cleaner
(6)
12
Terminal
configuration
1
5
2
R2
Hole for
testing
3
φ9
Dust
through hole
R2
4
5
6
Hole for sensitivity
adjustment volume
V-LED
LED-GND
LED
S-GND
VO
VCC
❈ Unspecified tolerance : ±0.3mm
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
GP2Y1001AU
■ Electro-optical Characteristics
Parameter
Detecting sensitivity
Output voltage (no dust)
Output voltage range
LED terminal current
Dissipation current
Symbol
Conditions
MIN.
TYP.
K
VOC
VOH
ILED
ICC
*1 *2 *3 *4
0.84
1.2
*2 *3 *4
0
10.2
1.2
−
−
13
13
RL=4.7kΩ
*2 *3 *4
LED terminal=0V
*2 *3
RL=∞
*2 *3 *4
−
(Ta=25°C, Vcc=12V)
Unit
MAX.
1.56
V/ (0.1mg/m3)
V
2.5
V
−
mA
20
mA
20
*1 Dust density shall be measured the density of Mild seven by using a digital dust indicator. (P-5L2 made by SIBATA SCIENTIFIC TECHNOLOGY LTD.)
3
Sensitivity:K shall be specified about output voltage change when dust density is changed 0.1mg/m
*2 Input condition for LED input terminal (pulse driving condition) is shown in Fig.1
*3 Refer to Fig.1
*4 Refer to Fig.2
Fig.1 Input Condition for LED Input Terminal
GP2Y1001AU
R=300Ω
1
3
+
VCC
C=100µF
ILED
T=10ms
PW=0.32ms
2
Fig.2 Sampling Timing of Output Pulse
ON
ILED
OFF
Output pulse
0.24ms
Sampling
■ Recommended Input Condition for LED Input Terminal
Parameter
Pulse cycle
Pulse width
Symbol Recommendation Unit
T
10±1
ms
0.32±0.02
ms
PW
GP2Y1001AU
Fig.3 Internal Block Diagram
Operation
circuit
LED
Light
detector
Amp.
Dust or smoke
particle
12
Output voltage (V)
10
8
6
4
2
0
0.2
0.4
0.6
Amp.
VCC
1
V-LED
3
LED
2
LED-GND
5
Output terminal (VO)
4
S-GND
Case
Sensitivity adjustment
Fig.4 Output Voltage vs. Dust Density
0
Amp.
6
0.8
Dust density (mg/m3)
1
1.2
Application Circuits
NOTICE
●The circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
●Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
●Observe the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
●Contact a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
●If the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
●This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
●Contact and consult with a SHARP representative if there are any questions about the contents of this
publication.
115