N E T- 3 5 35W Triple Output Switching Power Supply Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978)453-7272 series www.total-power.com Features : Universal AC input / Full range Protections: Short circuit / Over load / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty SPECIFICATION MODEL NET-35A CH1 5V CH2 CH3 12V RATED CURRENT 3A 1A CURRENT RANGE Note.6 0.5 ~ 4A RATED POWER OUTPUT INPUT -5V 12V 0.5A 3A 1A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 4A 29.5W 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.75A/115VAC NET-35D CH2 CH3 -12V CH1 5V 15V 0.5A 2.5A 1A CH2 CH3 -15V CH1 5V 24V 12V 0.5A 2.5A 0.5A 1A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 3.5A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 3.5A 0.1 ~ 1A 33W HOLD UP TIME (Typ.) 35W 0.1 ~ 1A 36.5W 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p 6.0% 1.0% 3.0% 1200ms, 30ms/115VAC at full load CH1: 4.75 ~ 5.5V 8.0% 2.0% 8.0% 2.0% 8.0% 8.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 1.5% 3.0% 3.0% 1.5% 3.0% 3.0% CH1: 4.75 ~ 5.5V 10ms/115VAC at full load 120 ~ 370VDC 79% 0.5A/230VAC 79% 79% COLD START 45A LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CB(IEC60950-1) Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A EMS IMMUNITY MTBF 386.2Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING NOTE CH3 500ms, 30ms/230VAC WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE OTHERS CH2 SETUP, RISE TIME WORKING TEMP. (Note 6) NET-35C CH1 5V RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% 6.0% 6.0% 2.0% 1.0% 1.0% 1.0% 0.5% LINE REGULATION Note.4 0.5% 3.0% 3.0% 3.0% 1.5% LOAD REGULATION Note.5 1.5% PROTECTION EMC NET-35B OUTPUT NUMBER DC VOLTAGE 99*97*36mm (L*W*H) 0.36Kg; 45pcs/17.2Kg/0.93CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. N E T- 3 5 35W Triple Output Switching Power Supply Mechanical Specification 20.5 Case No. 905 Unit:mm 36 55 2 3.5 51.5 1 9.5 series 3 5.5 97 8.2 4 55.5 2- M 3 5 6 7 +V ADJ. 3.5 4.5 89 99 6.5 Terminal Pin. No Assignment Assignment DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 87 3 3.5 74 18 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING fosc : 60KHz RECTIFIERS & FILTER V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG CONTROL O.L.P. 36 2-M 28 3.5 17.5 7 Assignment Pin No. Pin No. AC/L 1 5 AC/N 2 6 3 7 FG 4 DC OUTPUT V3 O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 60 50 40 85 95 100 AMBIENT TEMPERATURE ( ) Authorized Distributor: Total Power International, Inc. 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Toll Free: 877-646-0900(US) PH# (978)453-7272 www.total-power.com