Source EDR-L-55B-L-SFCL Eled fc receptacle Datasheet

ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
Features
• 1300nm or 1550nm Wavelength
• High Optical Power
• High Operating Current
• High Operating Temperature
• Low Modal Noise
• For Singlemode & Multimode use
• Custom Designed FC Receptacle
• For Datacom or Measurement Applications
• RoHS Compliant available
Absolute Maximum Ratings (Tc=25ºC)
Parameter
Symbol
Condition
Rating
Unit
Reverse Voltage
Vr
CW
2.5
V
Forward Current
If
CW
150
mA
Operating Temperature
T opr
-
-20 ~ 70
ºC
Storage Temperature
T stg
-
-40 ~ 85
ºC
(All optical data refer to a coupled 9/125µm SM & 50/125µm MM fiber)
Optical and Electrical Characteristics 1300nm (Tc=25ºC)
Parameter
Symbol
Min
Typ
Max
Unit
λ
1260
1300
1340
nm
CW
Spectral Width
∆λ
30
-
70
nm
CW(FWHM)
Operating Current
Output Power (SM, 9/125µm)
L
M
H
U
Output Power (MM, 50/125µm)
M
H
U
Iop
-
80
-
mA
CW
PO
10
50
100
150
-
-
µW
CW at Iop=80mA
PO
50
100
200
-
-
µW
CW at Iop=80mA
Wavelength
Test Conditions
-
10
%
λ±10nm
Foward Voltage
Vf
-
1.2
2.0
V
CW
Rise Time
Tr
-
1.5
-
ns
Fall Time
Tf
-
2.5
-
ns
-
4
-
dB
Spectral Ripple
Output Power Variation
LUMINENTOIC.COM
-
25ºC to 70ºC
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS703-JUN2907
rev. A.8
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
(All optical data refer to a coupled 9/125µm SM & 50/125µm MM fiber)
Optical and Electrical Characteristics 1550nm (Tc=25ºC)
Parameter
Symbol
Min
Typ
Max
Unit
Test Conditions
λ
1510
1550
1580
nm
CW
Spectral Width
∆λ
45
-
100
nm
CW(FWHM)
Operating Current
Iop
-
80
100
mA
CW
Output Power (SM, 9/125µm)
L
M
H
PO
10
20
30
-
-
µW
CW at Iop=80mA
Output Power (MM, 50/125µm)
L
M
H
PO
30
50
70
10
µW
CW at Iop=80mA
-
-
%
λ±10nm
CW
Wavelength
Spectral Ripple
Foward Voltage
Vf
-
1.2
2.0
V
Rise Time
Tr
-
1.5
-
ns
Fall Time
Tf
-
2.5
-
ns
-
4
-
dB
Output Power Variation
LUMINENTOIC.COM
25ºC to 70ºC
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS703-JUN2907
rev. A.8
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
Pin Assignment
Mechanical
Drawing
Units in mm.
Mechanical Drawing
3
2
1
Dril Thru and Tapped 2-56
(2 Places)
2-#2-56 THROUGH
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS703-JUN2907
rev. A.8
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
Ordering Information
EDR-L-XXB-X-XFCX-XX
Family
EDR=ELED Receptacle
Device
L=Long
Wavelength
30:1300nm
55:1550nm
Power
L/M/H/U
Connector Option
FC = FC
Fiber
Tolerance
S=9/125µm
M=50/125µm
B=+/- 40nm
E=FC
G=FC-SF
L=FC-BL
F=FC-L
RoHS Compliant
Blank/G5/GR
Blank = RoHS non-compliant product
G5 = RoHS 5/6-compliant product (lead exemption)
GR = Full RoHS compliant product (no exemption)
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended.
Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notice
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as
“preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied,
and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the
company’s Terms and Conditions of Sale for further warranty information.
Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and
Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights.
Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or
death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify
Luminent for any damages resulting from such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2007
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS703-JUN2907
rev. A.8
Similar pages