HuaXinAn H3R5-150 3-electrode gas discharge tube Datasheet

(Ø5x7.6mm)
3-Electrode Gas Discharge Tubes
5KA
1:Dimension(mm)
3:Features
2:Main Applications
•PCI Cards protection
•Telephone/Fax/Modem protection
•single line protection
•ADSL/XDSL Splitter,Power Supply
•Surge Protection Device/Surge Protector
•100% Lead-Free(RoHs Compliant )
•Non-Radioactive
•Low capacitance (≤1pF)
•Fast Response-time,High Insulation Resistance.
•Small size :Ø5x7.6(mm)
4 Electrical Characteristics
DC
Spark-over
Voltage
@ 100V/S
Impulse
Spark-over
Voltage
Impulse
Spark-over
Voltage
@100V/μs
@1KV/μs
V
V
V
H3R5-75
75±20%
<500
H3R5-90
90±20%
H3R5-150
Insulation
Resistance
Capacitance
(1MHz)
Impulse
AC discharge
discharge
current
current(8/20
(50Hz,1s,10ti
μs)
mes)
GΩ
10 Times
A
PF
<600
>1
5KA
5
≤1
<500
<600
>1
5KA
5
≤1
150±20%
<500
<600
>1
5KA
5
≤1
H3R5-230
230±20%
<600
<700
>1
5KA
5
≤1
H3R5-250
250±20%
<600
<700
>1
5KA
5
≤1
H3R5-350
350±20%
<900
≤ 1000
>1
5KA
5
≤1
H3R5-420
420±20%
<900
≤ 1000
>1
5KA
5
≤1
H3R5-470
470±20%
<1100
≤ 1200
>1
5KA
5
≤1
H3R5-600
600±20%
<1200
≤ 1300
>1
5KA
5
≤1
Part Number
Packing Quantity : 100PCS
Specifications are subject to change without notice
[email protected]
1
HUAAN LIMITED
www.huaandz.com
Tel:+86-755-27465585
Similar pages