ETC2 EM3-DINAV33CX Energy management energy meter with plug-in output module Datasheet

Energy Management
Energy Meter with plug-in Output Modules
Type EM3-DIN
• Class 2 (active energy)
• Class 3 (reactive energy)
• Active reactive energy meter
• Direct connection up to 90A
• Electromechanical display 6+1DGT
• LED for the indication of the consumed energy
• Selection of the displayed energy by means of dip-switch
• Optional pulse output (as a module)
• Self power supply or auxiliary power supply
115VAC, 230VAC 50-60Hz
• Full compliance with EN61036 (active energy, class 2)
• Full compliance with EN61268 (reactive energy, class 3)
• Dimensions: 9 DIN-modules
• Sealable housing
Product description
EM3-DIN is a three-phase
energy meter for the measure
of active or reactive energy;
the 208VL-L, 220VL-L
and
400VL-L meters are self-supplied, while the 660VL-L meters
are provided with auxiliary
Type selection
How to order
power supply. EM3-DIN is
provided with: 6+1DGT electromechanical indicator for
the indication of kWh or
kvarh; one green LED for the
indication of power ON; one
red LED blinking proportionally to the consumed energy.
EM3-DIN AV9 3 X X
Model
Range code
System
Power supply
Slot A
Important note: the AV2 model is suitable only for three-phase
unbalanced system without neutral.
Range code
System
Power supply
Slot A (retransmission)
Auxiliary Power Supply (C or D):
AV3: 660VL-L / 20(90)AAC
Self Power Supply (X):
AV2: 220VL-L / 20(90)AAC
AV8: 208VL-L / 20(90)AAC
AV9: 400VL-L / 20(90)AAC
3 : Three-phase,
unbalanced load
C: 115VAC - 15+10%
50-60Hz (only range AV3)
D: 230VAC -15+10%
50-60Hz (only range AV3)
X: Self power-supply
X:
O:
R:
None
Module AO2900
Dual open collector
pulse output
Module AO2910
One relay output + one
open collector output.
Input specifications
Accuracy
Active energy
Reactive energy
Start-up current
Additional errors
Voltage variation
Frequency variation
Wave form
Voltage disymmetry
External continuous magnetic
induction
Magnetic induction
HF electromagnetic field
Accessories influence
Temperature drift
Measurements
Wave form
Crest factor (I ≤ 20A)
Basic current (Ib)
Maximum current (Imax)
Overload
Continuous: current
For 10ms: current
Class 2, according to EN61036
Class 3, according to EN61268
80mA
Acc. to EN61036, EN61268
< 0.5%
< 0.5%
<1% (3rd harmonic: 10%)
< 0.5% (referred to the
rated input voltage)
0
0 (up to 0.5 mT)
< 1%
0
≤ 250 ppm/°C
Active or reactive energy
sinusoidal and distorted
≤ 6 (127A peak max)
20A (according to EN61036
/EN61268)
90A (according to EN61036/
EN61268)
4.5 x Ib
30 Imax @ 50Hz
Specifications are subject to change without notice
Rated input voltage
AV2 (AE2004)
AV3 (AE2002, AE2003)
AV8 (AE2001)
AV9 (AE2000)
Input impedance
AV2
AV3
AV8
AV9
Frequency
Electrical system
Display
Power supply
Energy consumption
Selection of displayed energy
Dip-switch 1
EM3-DINDS240806
Un: 220VL-L,
-10%≤Un≤+15%, 50-60Hz
Un: 660VL-L,
-20%≤Un≤+15%, 50-60Hz
Un: 208VL-L,
-20%≤Un≤+15%, 50-60Hz
Un: 400VL-L
-20%≤Un≤+15%, 50-60Hz
> 720kΩ (220VL-L), ≤ 4VA
> 1.97MΩ (660VL-L), ≤ 4VA
> 720KΩ (208VL-L), ≤ 4VA
> 720KΩ (400VL-L), ≤ 4VA
50-60 Hz
3-phase, unbalanced with or
without neutral. Note: in the
self-supplied version, the
neutral must be connected
to the measuring inputs.
Electromechanical type
6+1 DGT
Green LED, ON if supplied
Red LED, 640 imp./kWh/
kvarh (min. period: 0.5s)
By means of DIP-switch
ON: active energy
OFF: reactive energy
1
EM3-DIN
Output specifications
Pulse outputs (on request)
Number of outputs
Channel 1
Channel 2
Number of pulses
Type
Pulse duration
Leakage current
Insulation
AO2900, slot A
2
Pulse outputs to be used as
retransmission of the
energies:
active energy
reactive energy
10 / kWh, 10 / kvarh
Open collector (NPN transistor)
VON 1.2VDC / max 100mA
VOFF 30VDC max
220ms (ON), ≥200ms (OFF)
according to DIN43864
≤10µA, @ 30V, 60°C
By means of optocouplers,
2000Vrms for 1 minute
between measuring inputs
and pulse outputs.
Insulation between the two
outputs: functional
Relay + open collector
output. Working mode like
AO2900.
One static output+one relay
output, other characteristics
like AO2900.
Static type like module
AO2900; Relay type: SPDT,
AC1, AC15: 1AAC @250VAC
2000 VRMS outputs to
measuring inputs,
2000 VRMS output to
supply input.
Insulation between the two
outputs: 2000 VRMS
AO2910 module
Pulse output
Output type
Insulation
Power supply specifications
Self power supply
400VAC VL-L
-20% +15% 50-60Hz
208VAC VL-L
-20% +15% 50-60Hz
220VAC VL-L
-10+15%, 50-60Hz
Auxiliary power supply
230VAC -15+10% 50-60Hz
115VAC -15+10% 50-60Hz
General specifications
Operating temperature
-20 to +55°C (14°F to 131°F)
(R.H. from 0 to 90%
non-condensing @ 40°C)
Storage temperature
Dielectric strength
Installation category
EMC
Burst
Immunity to irradiated
electromagnetic fields
Electrostatic discharges
Radio frequency emissions
Pulse voltage (1.2/50µs)
according to EN61036
and EN61268
-20 to +70°C (14°F to 140°F)
4000Vrms for 1 minute
Cat. lll (IEC 664)
4kV / level 4 (EN61000-4-4)
10V/m from 26 to 1000MHz
(EN61000-4-3)
15kV (EN61000-4-2)
according to CISPR 14
and CISPR 22
8kV (EN61000-4-5)
Standards
Metrology
Safety
Pulse output
Connections
Cable cross-section area
EN61036, EN61268
IEC-664
DIN 43864
Screw-type,
Max. 35 mm2 (measuring inputs)
Min. 6 mm2 (measuring inputs)
Other inputs: 4 mm2
Min./Max. screws tightening torque 2 Nm / 6 Nm (90A inputs)
Housing
Dimensions
162.5 x 90 x 63 mm
Material
ABS, NORYL,
PC self-extinguishing
Mounting
DIN-rail or wall
Degree of protection
Front: IP40
Screw terminals: IP20
Weight
Approx. 800 g
(packing included)
Available models and modules
Type
EM3-DIN AV9.3.X
EM3-DIN AV8.3.X
EM3-DIN AV2.3.X
EM3-DIN AV3.3.C
EM3-DIN AV3.3.D
Open collector output
Relay + open coll. output
2
Inputs
400VL-L / 20(90)AAC
208VL-L / 20(90)AAC
220VL-L / 20(90)AAC
660VL-L / 20(90)AAC
660VL-L / 20(90)AAC
Power
Supply
Self power supply
Self power supply
Self power supply
Number of
channels
115VAC - 15+10%
230VAC - 15+10%
2
2
Specifications are subject to change without notice
Ordering
code
AE2000
AE2001
AE2004
AE2002
AE2003
AO2900
AO2910
EM3-DINDS240806
EM3-DIN
Wiring diagrams
EM3-DIN 20(90)A
Self power-supplied
Fig. 1
Direct connection (3-phase system + N)
Auxiliary power-supply
Fig. 2
Direct connection (3-phase system)
Auxiliary power-supply
Fig. 3
Direct connection (3-phase system + N)
Wiring diagrams (optional module)
Relay + open collecttor output Fig. 2
Open collector output Fig. 1
Only open collector outputs: the grounds of the outputs are separated, and therefore it’s possible to carry out, for the same module,
two different connections. The load resistance (Rc) must be designed so that the closed contact current is lower than 100mA; the
VDC voltage must be lower than or equal to 30V.
Accuracy
Accuracy (RDG) depending on the current
Accuracy (RDG) depending on the current
+4%
Error
+5%
+2.5%
+4%
+2%
+3%
0%
0%
-2%
-3%
-2.5%
-4%
-4%
1A
(0.05 Ib)
2A
(0.1) Ib
20A (Ib)
90A (Imax)
1A
(0.05 Ib)
2A
(0.1) Ib
20A (Ib)
90A (Imax)
EN 61268/ IEC 61268 limits
Reactive energy
Start-up current: 80mA
EN 61036/ IEC 61036 limits
Active energy
Start-up current: 80mA
Specifications are subject to change without notice
-5%
Error
EM3-DINDS240806
3
EM3-DIN
Front panel description
1
3
2
4
1. Red LED
Indicates the consumed energy (640 pulses / kWh,
minimum period 0.5ms) blinking proportionally.
2. Green LED
Indicates power ON.
3. Display
Electromechanical type, 6+1 DGT, displays kWh or kvarh
according to the selection made by means of an internal
dip-switch.
4. Engineering unit
Removable double sided [front (kWh) / back (kvarh)] label
Dimensions
Terminal board
4
Dual open collector
output module
Realy + open collecttor output
AO 2900
AO 2910
Specifications are subject to change without notice
EM3-DINDS240806