Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 3W Output Power
• Ultra-Compact SMT Case
• Wide 4:1 Input
• 1,500 VDC Isolation
• Single & Dual Outputs
• -40ºC to +80ºC Operation
• 16 Standard Models
• Tight Line/Load Regulation
• Available on Tape/Reel
Input
Parameter
Conditions
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
Max.
36.0
75.0
8.5
17.0
8.0
16.0
2,000
(Pi) Filter - Meets EN 55022 Class A
Input Voltage Range
Start Up Voltage
Under Voltage Shutdown
Short Circuit Input Power
Input Filter
Min.
9.0
18.0
4.5
8.5
Typ.
24.0
48.0
6.0
12.0
Units
VDC
VDC
VDC
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Response Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Overload Protection
Output Short Circuit
Conditions
Min.
Typ.
Dual Output, Balanced Loads
For VIN = Min to Max
For IOUT = 15% to 100%
See Note 2
±1.0
±0.5
±0.5
50
300
25% Load Step Change
±3
±0.01
Foldback Type
110
150
Continuous (Autorecovery)
Max.
±2.0
±2.0
±1.0
±1.2
100
600
±0.02
Units
%
%
%
mV P - P
µS
%
%/ºC
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off, See Note 4
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Conditions
Min.
1,500
1,000
Typ.
Max.
350
350
500
Min.
2.5
-0.7
Typ.
Min.
-40
Typ.
Units
VDC
M
pF
kHz
Max.
Units
5.5
VDC
0.8
VDC
5
mA
Referenced to Negative Input (pin 1)
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-50
Free Air Convection
RH, Non-condensing
Max.
+80
+105
+125
Units
ºC
ºC
ºC
95
%
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.14 Oz (4.2g)
Reliability Specifications
Parameter
MTBF
Shock & Vibration
Moisture Sensitivity Level (MSL)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25ºC, Gnd Benign
300
kHours
A random waveform 1~200 Hz/0.52 Grms, 30 min. on each axis
(X, Y, Z) and 2~300 Hz/1.05 Grms, 30 min. on each axis (X, Y, and Z)
IPC/JEDEC J-STD-020D.1
Level 2
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
Min.
Typ.
24 VDC Input
48 VDC Input
See Note 5
1.5 mm From Case For 10 Sec.
Max.
50.0
100.0
245
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
ML324S-03RU
ML324S-05RU
ML324S-12RU
ML324S-15RU
ML324S-24RU
ML324D-05RU
ML324D-12RU
ML324D-15RU
ML348S-03RU
ML348S-05RU
ML348S-12RU
ML348S-15RU
ML348S-24RU
ML348D-05RU
ML348D-12RU
ML348D-15RU
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
24
9.0 - 36.0
110
30
24
9.0 - 36.0
160
30
24
9.0 - 36.0
156
30
24
9.0 - 36.0
156
30
24
9.0 - 36.0
156
30
24
9.0 - 36.0
162
30
24
9.0 - 36.0
156
30
24
9.0 - 36.0
156
30
48
18.0 - 75.0
55
20
48
18.0 - 75.0
80
20
48
18.0 - 75.0
78
20
48
18.0 - 75.0
78
20
48
18.0 - 75.0
78
20
48
18.0 - 75.0
81
20
48
18.0 - 75.0
78
20
48
18.0 - 75.0
78
20
Notes:
1. The specified maximum capacitive load is for
each output.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor
be placed from +VOUT to -VOUT for single output
models or from each output to common for dual
output models. For noise sensitive applications,
the use of 3.3 µF capacitors will reduce the
output ripple.
3. Transient recovery is measured to within a 1% error
band for a load step change of 75% to 100%.
4. The maximum control current at the on/off input (pin
2) during a logic high (+5V) is 400 µA. The maximum
control current to the on/off pin at logic low (0V) is -400
µA. If the on/off pin is left open, the unit operates. If
grounded, the unit will shut off.
5. The recommended reflow settings are a peak
temperature of 245 °C for a maximum period
(TPK) of 10S and a time above liquidous (TL) of <60
Output
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
600
600
250
200
125
±300
±125
±100
600
600
250
200
125
±300
±125
±100
Output
Rating
Efficiency Capacitive Fuse
Slow-Blow
(%, Typ)
Load
(mA)
(µF, Max)
90
90
38
30
19
±45
±19
±15
90
90
38
30
19
±45
±19
±15
75
78
80
80
80
77
80
80
75
78
80
80
80
77
80
80
800
800
800
800
800
800
800
800
400
400
400
400
400
400
400
400
220
220
47
47
47
47
47
47
220
220
47
47
47
47
47
47
Derating Curve, 3.3V & 5V Outputs
seconds at 217 °C. For more information, please
contact the factory.
6. Operation at no-load will not damage these units.
However, they may not meet all specifications.
7. The converter should be connected to a low
ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where the
converter output loading is high and input power
is supplied over long lines, it may be necessary
to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR
(<1.0 at 100 kHz) capacitor be mounted close
to the converter. For 24V input units a 4.7 µF is
recommended and for 48V input models, a 2.2 µF.
8. It is recommended that a fuse be used on the
input of a power supply for protection. See the
table above for the correct rating.
Mechanical Dimensions
Derating Curve, All Other Outputs
Board Layout
Pin Connections
Pin
Single
Dual
1
-VIN
-VIN
2
Remote On/Off
7
NC
NC
8
NC
Common
9
+VOUT
+VOUT
10
-VOUT
-VOUT
16
+VIN
+VIN
NC = No connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages