Minmax MSAU104 1w, miniature smd, single output dc/dc converter Datasheet

MSAU100 Series
1W, Miniature SMD, Single Output DC/DC Converters
Key Features
y
y
y
y
y
y
y
y
y
y
Efficiency up to 82%
1000VDC Isolation
MTBF > 2,000,000 Hours
Low Cost
Input 5 and 12VDC
Output 3.3, 5, 9, 12 and 15VDC
Temperature Performance -40] to +85]
Lead Frame Technology
UL 94V-0 Package Material
Interanl SMD Construction
Minmax's MSAU100 1W DC/DC's are in "gull-wing" SMT package,
weigh a mere 1.5 grams and meet 245]/10sec in solder-reflow for lead
free process.
The series consists of 9 models with input voltages of 5V and
12VDC which offers standard single output voltages of 3.3V, 5V, 9V, 12V
SMD
and 15VDC for the choice.
Their impressive guaranteed efficiencies enable all models to deliver
their fully rated output power from -40] to +85] without heat sinking
or forced-air cooling.
The MSAU100 series is an excellent selection for a variety of
applications including data communication equipments, distributed power
1000
VDC
$
systems, telecommunication equipments and industrial robot systems.
The MSAU100 units are available in tape and reel package.
I/O Isolation
Low Cost
Low Profile
Block Diagram
+Vo
+Vin
Bipolar
Push-Pull
Inverter
-Vin
-Vo
1
MINMAX
REV:0 2005/04
MSAU100 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
VDC
VDC
5
Max.
mA
200
MSAU101
MSAU102
MSAU103
MSAU104
5
( 4.5 ~ 5.5 )
MSAU105
MSAU111
MSAU112
MSAU113
12
( 10.8 ~ 13.2 )
MSAU114
Output Current
Input Current
Min.
mA
4
@Max. Load
mA (Typ.)
250
@No Load
mA (Typ.)
Efficiency
% (Max.)
10
@Max. Load
% (Typ.)
80
10
78
8
80
9
110
2
254
12
84
1.5
252
15
67
1
248
7
81
3.3
300
60
264
10
75
5
200
4
103
8
81
9
110
2
106
8
78
12
84
1.5
104
5
81
15
67
1
102
5
82
30
15
Notes :
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
Load
Regulation
Min.
Max.
Unit
5VDC Input Models
-0.7
9
VDC
VDC
12VDC Input Models
-0.7
18
Lead Temperature (1.5mm from case for 10 Sec.)
---
260
]
Internal Power Dissipation
---
450
mW
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Ripple & Noise measurement bandwidth is 0-20
MHz.
3. These power converters require a minimum
output loading to maintain specified regulation.
4. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
5. All DC/DC converters should be externally fused
at the front end for protection.
Environmental Specifications
Parameter
Conditions
Min.
Max.
Unit
Operating Temperature
Ambient
-40
+85
]
Operating Temperature
Case
-40
+90
]
-40
+125
]
---
95
%
Storage Temperature
Humidity
Cooling
6. Other input and output voltage may be available,
please contact factory.
7. Specifications subject to change without notice.
Free-Air Convection
Input Specifications
Parameter
Input Voltage Range
Reverse Polarity Input Current
Input Filter
REV:0 2005/04
Model
Min.
Typ.
Max.
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
---
---
0.3
All Models
MINMAX
Unit
VDC
A
Internal Capacitor
2
MSAU100 Series
Output Specifications
Parameter
Conditions
Output Voltage Accuracy
Line Regulation
For Vin Change of 1%
Load Regulation
Io=20% to 100%
Min.
Typ.
Max.
Unit
---
{1.0
{3.0
%
---
{1.2
{1.5
See Model Selection Guide
Ripple & Noise (20MHz)
%
%
---
60
120
mV P-P
---
---
150
mV P-P
Ripple & Noise (20MHz)
---
---
5
mV rms
Over Load
120
---
---
%
Temperature Coefficient
---
{0.01
{0.02
%/]
Ripple & Noise (20MHz)
Over Line, Load & Temp.
Output Short Circuit
0.5 Second Max.
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Isolation Voltage Rated
60 Seconds
1000
---
---
VDC
Flash Tested for 1 Second
1100
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
M[
Isolation Capacitance
100KHz,1V
---
40
100
pF
50
100
140
KHz
2000
---
---
K Hours
Isolation Voltage Test
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Capacitive Load
Models by Vout
3.3V
5V
9V
12V
15V
Unit
33
33
33
33
33
uF
Maximum Capacitive Load
Input Fuse Selection Guide
3
5V Input Models
12V Input Models
500mA Slow - Blow Type
200mA Slow - Blow Type
MINMAX
REV:0 2005/04
MSAU100 Series
90
100
80
Efficiency (%)
Efficiency (%)
90
80
70
70
60
50
40
60
50
30
Low
Nom
High
20
Efficiency vs Input Voltage
100LFM
40
60
80
100
Efficiency vs Output Load
400LFM
200LFM
80
Output Power (%)
20
Load Current (%)
Input Voltage (V)
100
10
60
Natural
convection
40
20
0
〜
-40
50
60
70
80
Ambient Temperature
90
100
110
]
Derating Curve
REV:0 2005/04
MINMAX
4
MSAU100 Series
Test Configurations
KHz) capacitor of 2.2uF for the 5V input devices, and a 1.0uF
for the 12V devices.
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to
simulate source impedance.
Capacitor Cin, offsets possible battery impedance.
Current ripple is measured at the input terminals of the
module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
Load
A good quality low ESR capacitor placed as close as
practicable across the load will give the best ripple and noise
performance.
To reduce output ripple, it is recommended to use 0.47uF
capacitors at the output.
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor.
Scope measurement should be made by using a BNC
socket, measurement bandwidth is 0-20 MHz. Position the
load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Single Output
DC / DC
Converter
-Vin
+
+Vin
Single Output
DC / DC
Converter
DC Power
Source
-
+Out
-Vin
Cout
Load
-Out
Copper Strip
Cout
Scope
Resistive
Load
Thermal Considerations
Many conditions affect the thermal performance of the
power module, such as orientation, airflow over the module
and board spacing. To avoid exceeding the maximum
temperature rating of the components inside the power
module, the case temperature must be kept below 90°C.
The derating curves are determined from measurements
obtained in an experimental apparatus.
-Out
Design & Feature Considerations
Maximum Capacitive Load
The MSAU100 series has limitation of maximum
connected capacitance at the output.
The power module may be operated in current limiting
mode during start-up, affecting the ramp-up and the startup
time.
For optimum performance we recommend 33uF maximum
capacitive load.
The maximum capacitance can be found in the data sheet.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
In applications where power is supplied over long lines and
output loading is high, it may be necessary to use a capacitor
at the input to ensure startup.
Capacitor mounted close to the power module helps
ensure stability of the unit, it is recommeded to use a good
quality low Equivalent Series Resistance (ESR < 1.0[ at 100
5
MINMAX
REV:0 2005/04
MSAU100 Series
Mechanical Dimensions
Connecting Pin Patterns
0.3[0.01]
Top View ( 2.54 mm / 0.1 inch grids )
12.7 [0.50]
1
2
3
5
4
0.60 [0.024]
7.62mm
2]
.0
R0
[
.5
R0
+4
6
8.0 [0.31]
7
1.7mm
0.9[0.04]
[Magnification of A]
2.0 [0.08]
8
10.8mm
6.2 [0.24]
1C
6.8 [0.27]
A
7.6 [0.30]
Tolerance
2.54mm
1.0mm Min
4
7.0 [0.28]
0.3 [0.01]
2.54 [0.100]
S SEATING
PLANE
9.2 [0.36]
11.2 [0.44]
Millimeters
X.X{0.25
Inches
X.XX{0.01
X.XX{0.13
X.XXX{0.005
{0.05
{0.002
Pin
Pin Connections
Physical Characteristics
Pin
Function
1
-Vin
2
+Vin
3
NA
4
-Vout
5
+Vout
6
NA
7
NA
8
NA
12.7*8.0*6.8 mm
Case Size
:
Case Material
:
Molding
Weight
:
1.5g
Flammability
:
UL94V-0
0.50*0.31*0.27 inches
NA : Not Available for Electrical Connection
The MSAU100 converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical
characteristics over a wide temperature range or in high humidity environments.
The encapsulant and unit case are both rated to UL 94V-0 flammability specifications.
Leads are tin plated for improved solderability.
REV:0 2005/04
MINMAX
6
MSAU100 Series
Packaging Specifications
30.4 Max
2.0+1 / -0
0 330.0 Max
0 100.0 Min
0 13.00± 0.25
All dimentions in mm
Tape
Sprocket hole 0 1.55 +0.1 / -0
4.00
2.00
Sprocket hole tolerance over any 10 pitches ± 0.2
11.50 1.75
13.20
24.00± 0.3
0 1.50 +0.25 / -0
All dimentions in mm
XX.XX± 0.1
11.60
7.20
7
Direction of Unreeling
16.00
0.4 +/- 0.05
0.30
MINMAX
REV:0 2005/04
MSAU100 Series
Tube
14.5
7.2
7.3
8.6 10.4
0.5
+/- 0.1
Tube material: PVC
4.5
5.0
All dimensions in mm, +/- 0.25mm
346 +/-1.5
Packaging Details
Packaging Style
Tube
Tape and Reel to IEC 286-3 Specifications
REV:0 2005/04
MINMAX
Quantity
25
500
8