96W Single Output Industrial DIN Rail Power Supply MDR-100 series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature ZCS/ZVS technology to reduce power dissipation Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 DC OK relay contact No load power consumption<1W LED indicator for power on 100% full load burn-in test 3 years warranty SPECIFICATION MODEL MDR-100-12 MDR-100-24 MDR-100-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 7.5A 4A 2A CURRENT RANGE 0 ~ 7.5A 0 ~ 4A 0 ~ 2A RATED POWER 90W RIPPLE & NOISE (max.) Note.2 120mVp-p OUTPUT 12 ~ 15V 24 ~ 30V 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% VOLTAGE ADJ. RANGE Note.5 3000ms, 50ms/230VAC 50ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.6 85 ~ 264VAC 47 ~ 63Hz PF 0.95/230VAC EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.3A/115VAC 0.8A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY (Note 4) OTHERS PF 0.98/115VAC at full load 86% 88% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover 90 10 (RTH2) detect on heatsink of power transistor Protection type : Shut down o/p voltage, re-power on to recover Relay contact rating(max.): 30V/1A resistive -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 0.03%/ (0 ~ 50 Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 UL508, TUV EN60950-1 approved EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A MTBF 346K hrs min. MIL-HDBK-217F (25 55*90*100mm (W*H*D) 0.42Kg; 30pcs/13.6Kg/0.82CUFT I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT DIMENSION PACKING NOTE 20ms/115VAC at full load 120 ~ 370VDC POWER FACTOR (Typ.) OVERLOAD EMC 3000ms, 50ms/115VAC at full load FREQUENCY RANGE LEAKAGE CURRENT SAFETY & 96W 200mVp-p 48 ~ 56V VOLTAGE TOLERANCE Note.3 SETUP, RISE TIME INPUT 96W 150mVp-p ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Deating maybe needed under low input voltages, please check the derating curve for more detail. File Name:MDR-100-SPEC 2011-03-22 MDR-100 96W Single Output Industrial DIN Rail Power Supply Mechanical Specification Case No.973A 35 55 series Unit:mm 100 5 5 5 5 5 +V +V -V -V DC OK DC OK + 90 +V ADJ N L 7.5 7.5 Install DIN rail TS35/7.5 or TS35/15 Block Diagram DC OK EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. O.L.P. DETECTION CIRCUIT FG PFC CONTROL PWM CONTROL O.V.P. O.T.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:MDR-100-SPEC 2011-03-22