Mean Well MDR-100-24 96w single output industrial din rail power supply Datasheet

96W Single Output Industrial DIN Rail Power Supply
MDR-100
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
ZCS/ZVS technology to reduce power dissipation
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
DC OK relay contact
No load power consumption<1W
LED indicator for power on
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
MDR-100-12
MDR-100-24
MDR-100-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
7.5A
4A
2A
CURRENT RANGE
0 ~ 7.5A
0 ~ 4A
0 ~ 2A
RATED POWER
90W
RIPPLE & NOISE (max.) Note.2 120mVp-p
OUTPUT
12 ~ 15V
24 ~ 30V
1.0%
1.0%
1.0%
LINE REGULATION
1.0%
1.0%
1.0%
LOAD REGULATION
1.0%
1.0%
1.0%
VOLTAGE ADJ. RANGE
Note.5 3000ms, 50ms/230VAC
50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.6 85 ~ 264VAC
47 ~ 63Hz
PF 0.95/230VAC
EFFICIENCY (Typ.)
85%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.3A/115VAC
0.8A/230VAC
COLD START 30A/115VAC
60A/230VAC
<1mA / 240VAC
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
FUNCTION DC OK SIGNAL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
(Note 4)
OTHERS
PF 0.98/115VAC at full load
86%
88%
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
90
10 (RTH2) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
Relay contact rating(max.): 30V/1A resistive
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
0.03%/ (0 ~ 50
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
UL508, TUV EN60950-1 approved
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
MTBF
346K hrs min. MIL-HDBK-217F (25
55*90*100mm (W*H*D)
0.42Kg; 30pcs/13.6Kg/0.82CUFT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
DIMENSION
PACKING
NOTE
20ms/115VAC at full load
120 ~ 370VDC
POWER FACTOR (Typ.)
OVERLOAD
EMC
3000ms, 50ms/115VAC at full load
FREQUENCY RANGE
LEAKAGE CURRENT
SAFETY &
96W
200mVp-p
48 ~ 56V
VOLTAGE TOLERANCE Note.3
SETUP, RISE TIME
INPUT
96W
150mVp-p
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Deating maybe needed under low input voltages, please check the derating curve for more detail.
File Name:MDR-100-SPEC 2011-03-22
MDR-100
96W Single Output Industrial DIN Rail Power Supply
Mechanical Specification
Case No.973A
35
55
series
Unit:mm
100
5 5 5 5 5
+V +V -V -V
DC OK
DC OK
+
90
+V ADJ
N
L
7.5 7.5
Install DIN rail TS35/7.5 or TS35/15
Block Diagram
DC OK
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.C.P.
O.L.P.
DETECTION
CIRCUIT
FG
PFC
CONTROL
PWM
CONTROL
O.V.P.
O.T.P.
DC OK Relay Contact
Contact Close
PSU turns on / DC OK.
Contact Open
PSU turns off / DC Fail.
Contact Ratings (max.) 30V/1A resistive load.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
60
50
40
85
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:MDR-100-SPEC 2011-03-22