Seite 27 Information 14:25 DC axial fans 20 m3/h max. 18.01.2011 Series 500 F 50 x 50 x 15 mm DC axial fans Highlights: – Compact fan with low power consumption. – Some models suitable for use at high ambient temperatures. DC centrifugal fans Life expectancy L10∆ 62 500 2 /2 1,0 5 000 -20...+70 50 000 / 20 000 62 500 2 /2 512 F 20 11,8 12 10,8...13,2 30 4,5 1,0 514 F 20 11,8 24 21,6...26,4 30 4,5 Hours P. 110 ACmaxx / i-maxx VDC Specials 50 000 / 20 000 VDC Curve -20...+70 CFM (40 °C) see P. 15 5 000 m3/h dB(A) Bel(A) Service life L10 (60 °C) ebm-papst Standard Hours Type Nominal data Service life L10 (20 °C) ebm-papst Standard Temperature range Power input °C Voltage range RPM Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Sound pressure level General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 25 g. Model with temperature range up to +85 °C. 11 6,5 12 11,5...13,2 12 3,7 0,4 3 000 -20...+85 50 000 / 20 000 65 500 1 512 F-532 20 11,8 12 10,8...13,2 30 4,5 0,9 5 000 -20...+85 50 000 / 20 000 65 500 2 AC centrifugal fans [in H2O] Pa AC axial fans 512 FL-547 DC fans - specials Kompaktlüfter__2011__EN__Final__17_01_2011_:Vorlage 30 0 Accessories 5 1 2 4 5 6 10 8 10 15 CFM m³/h PWM HP 27 Representatives 0,06 10 0,04 0,10 15 0,02 20 0,08 2 25 Speed signal /2 VDC mA VDC mA 2 £ 30 0 30 2 2 31 400 F £ 0.4 1 £ 30 0 30 2 2 32 400 £ 0.4 1 £ 30 0 30 2 2 33 420 J £ 0.4 2 £ 15 0 15 4 2 34 500 F £ 0.4 1 £ 30 0 30 2 2 35 600 F £ 0.4 1 £ 30 0 30 2 2 36 620 £ 0.4 2 £ 30 0 30 4 2 37 630 U £ 0.4 2 £ 30 0 30 4 2 38 600 N £ 0.4 2 £ 28 0 28 4 2 39 600 J £ 0.4 2 £ 30 0 30 4 2 41 700 F £ 0.4 2 £ 30 0 30 4 2 42 8450 £ 0.4 2 £ 28 0 28 4 2 43 8400 N £ 0.4 2 £ 28 0 28 4 2 44 8400 N VARIOFAN £ 0.4 2 £ 30 0 30 4 2 45 8300 £ 0.4 2 £ 30 0 30 4 2 46 8200 J £ 0.4 2 £ 30 0 30 4 2 47 3400 N £ 0.4 2 £ 28 0 28 4 2 48 3400 N VARIOFAN £ 0.4 2 £ 30 0 30 4 2 49 3300 N £ 0.4 2 £ 30 0 30 4 2 50 3212 J / 3214 J £ 0.4 2 £ 30 0 30 4 2 51 3218 J £ 0.4 2 £ 60 0 60 4 2 51 3250 J £ 0.4 2 £ 60 0 60 4 3 52 4412 F / 4414 F £ 0.4 2 £ 30 0 30 4 2 53 4418 F £ 0.4 2 £ 60 0 60 4 2 53 4400 FN £ 0.4 2 £ 30 0 30 4 2 55 4312 / 4314 £ 0.4 2 £ 30 0 30 4 2 56 4318 2016-01 Fan description Basic type Condition: Isource mA £ 0.4 Page £ 0.4 2 £ 60 0 60 4 2 56 4312 / 4314 VARIOFAN £ 0.4 2 £ 30 0 30 4 2 57 4318 VARIOFAN £ 0.4 2 £ 60 0 60 4 2 57 4400 £ 0.4 2 £ 30 0 30 4 2 58/59 4100 N £ 0.4 2 £ 30 0 30 4 2 60 4100 NHH...NH6 £ 0.4 2 £ 60 0 60 10 2 61 4100 NH7...NH8 £ 0.4 2 £ 60 0 60 20 3 62 DV 4100 £ 0.4 2 £ 30 0 30 4 2 63 5200 N £ 0.4 2 £ 30 0 30 4 2 64 DV 5200 £ 0.4 2 £ 30 0 30 4 2 65 Subject to change 168 Pulses per revolution Speed signal US High VDC Signal data Tach operating voltage UBS max. Condition: Isink Type 250 Electrical hookup All voltages measured to ground. External load resistor Ra / US / UBS required. Admissible sink current Isink max. Speed-proportional, square-wave signal for external monitoring of the fan motor speed 2, 3, or 6 pulses per revolution Open-collector signal output Extremely wide operating voltage range Easy adaptation to user interface Connection via separate cable The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Speed signal US Low – – – – – – – Information Tach operating voltage UBS max. Admissible sink current Isink max. VDC mA VDC mA 2 £ 15 0 5 20 2 66 5114 N / 5118 N £ 0.4 2 £ 60 0 60 20 2 66 5300 £ 0.4 2 £ 60 0 60 4 2 67 5300 TD £ 0.4 2 £ 60 0 60 20 6 68 7112 N / 7118 N £ 0.4 2 £ 60 0 60 20 2 69 7114 N £ 0.4 2 £ 30 0 30 20 2 69 7200 N £ 0.4 2 £ 15 0 15 20 2 70 6400 £ 0.4 2 £ 60 0 60 20 2 71 6300 TD £ 0.4 2 £ 60 0 60 20 6 75 6300 N £ 0.4 2 £ 60 0 60 20 6 76 6300 NTD £ 0.4 2 £ 60 0 60 20 6 77 6300 £ 0.4 2 £ 60 0 60 20 2 78 DV 6300 TD £ 0.4 2 £ 60 0 60 20 6 80 2200 FTD £ 0.4 2 £ 60 0 60 20 6 81 RL 48 £ 0.4 2 £ 30 0 30 4 2 97 RL 65 £ 0.4 2 £ 30 0 30 4 2 98 RL 90 N £ 0.4 2 £ 30 0 30 4 2 99 RLF 100 £ 0.4 2 £ 30 0 30 4 2 100 RG 90 N £ 0.4 2 £ 30 0 30 4 2 101 RG 125 N £ 0.4 2 £ 30 0 30 4 2 102 RG 140 N £ 0.4 3 £ 60 0 60 4 2 103 RG 160 N £ 0.4 2 £ 30 0 30 20 2 104 RG 160 NTD £ 0.4 2 £ 60 0 60 20 6 105 RG 190 TD £ 0.4 2 £ 60 0 60 20 6 106 RG 220 TD £ 0.4 2 £ 60 0 60 20 6 107 RG 225 TD £ 0.4 2 £ 60 0 60 20 6 108 RET 97 TD £ 0.4 2 £ 60 0 60 20 6 109 REF 100 £ 0.4 2 £ 30 0 30 4 2 110 RER 120 TD £ 0.4 2 £ 60 0 60 20 6 112 RER 133 TD £ 0.4 2 £ 60 0 60 20 6 117 RER 160 NTD £ 0.4 2 £ 60 0 60 20 6 119 REF 175 TD £ 0.4 2 £ 60 0 60 20 6 120 RER 175 TD £ 0.4 2 £ 60 0 60 20 6 121 RER 190 TD £ 0.4 2 £ 60 0 60 20 6 122 RER 220 TD £ 0.4 2 £ 60 0 60 20 6 128 RER 225 TD £ 0.4 2 £ 60 0 60 20 6 129 Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials Page Note: Fans that come with these fan specials could have variations with respect to the temperature range, voltage range, and power consumption compared to standard fans without specials. 169 2016-01 Subject to change DC centrifugal fans Condition: Isource mA £ 0.4 Representatives Speed signal US High VDC Fan description Basic type Condition: Isink Type 5112 N Signal data Pulses per revolution Speed signal US Low DC axial fans Available on request: – Electrically isolated speed signal circuit – Varying voltage potentials for power and logic circuit