Current Transducer HXS 20-NP For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 5-10-20 A All Data are given with a RL = 10 kΩ Electrical data IPN IPM VOUT GTH VREF RL ROUT CL VC IC Primary nominal current rms Primary current, measuring range Analog Output voltage @ IP Theoretical sensitivity Reference voltage 1) Ouput voltage Ouput impedance Load impedance Load resistance Output internal resistance Capacitive loading (± 20 %) Supply voltage (± 5 %) 2) Current consumption @ VC = 5V ± 20 A ± 60 A VOE ± (0.625. IP/ IPN) V 0.625 V/ IPN 2.5 ± 0.025 V typ. 200 Ω ≥ 200 kΩ ≥ 2 kΩ < 5 Ω = 4.7 nF 5 V 19 mA Accuracy - Dynamic performance data Accuracy 3) @ IPN , TA = 25°C εL Linearity error 0 .. IPN 0 .. 3 x IPN TCVOE Temperature coefficient of VOE (+25.. 105°C) (-40.. +25°C) TCVREF Temperature coefficient of VREF (+25.. 105°C) (-40.. +25°C) TCVOE/VREFTemperature coefficient of VOE /VREF TCG Temperature coefficient of G VOE Electrical offset voltage @ IP = 0, TA = 25°C VOM Magnetic offset voltage @ IP = 0 after an overload of 3 x IPN tra Reaction time to 10 % of IPN step tr Response time to 90 % of IPN step di/dt di/dt accurately followed Vno Output voltage noise (DC .. 10 kHz) (DC .. 1 MHz) BW Frequency bandwidth (- 3 dB) 4) X ≤ ± 1 % ≤ ± 0.5 % ≤ ± 1 % ≤ ± 0.4 mV/K ≤ ± 0.525 mV/K ≤ ± 0.01 %/K ≤ ± 0.015 %/K ≤ ± 0.15 mV/K ≤ ±0.05% of reading//K VREF ± 0.0125 V < ± 0.7 < 3 < 5 > 50 < 20 < 40 DC .. 50 % µs µs A/µs mVpp mVpp kHz General data TA TS m Ambient operating temperature 5) Ambient storage temperature Mass Standards Notes: 1) - 40 .. + 105 °C - 40 .. + 105 °C 10 g EN 50178: 1997 It is possible to overdrive VREF with an external reference voltage between 1.5V 2.8V providing its ability to sink or source approximately 5 mA. 2) Maximum supply voltage (not operating) < 6.5 V 3) Excluding Offset and Magnetic offset voltage 4) Small signal only to avoid excessive heatings of the magnetic core. 5) UL recognized with surrounding temperature until +85℃ Features ●● Hall effect measuring principle ●● Multirange current transducer through PCB pattern lay-out ●● Galvanic isolation between primary and secondary circuit ●● Isolation test voltage 3500 V ●● Low power consumption ●● Extremely low profile < 11 mm ●● Single power supply + 5 V ●● Fixed offset & sensitivity ●● Isolated plastic case recognized according to UL 94-V0. Advantages ●● Small size and space saving ●● Only one design for wide current ratings range ●● High immunity to external interference ●● Internal & external reference. Applications ●● AC variable speed drives and servo motor drives ●● Static converters for DC motor drives ●● Battery supplied applications ●● Uninterruptible Power Supplies (UPS) ●● Switched Mode Power Supplies (SMPS) ●● Power supplies for welding applications. Application domain ●● Industrial. Page 1/3 120416/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer HXS 20-NP Isolation characteristics Vd dCp dCI CTI Rms voltage for AC isolation test, 50 Hz, 1 min Creepage distance Clearance distance Comparative Tracking Index (group I) 3.5 > 5.5 > 5.5 > 600 kV mm mm V Applications examples According to EN 50178, IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Single isolation 600 V 600 V Reinforced isolation 300 V 150 V According to UL508 standard and following conditions: Max. Voltage 600V ●● Over voltage category OV 3 ●● Pollution degree PD2 Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 120416/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HXS 20-NP (in mm) Required connection circuit Primary current Number of primary turns 1 2 nominal IPN [ A ] maximum IP [ A ] 20 60 10 4 30 5 15 Mechanical characteristics ●● General tolerance ●● Transducer fastening & connection of primary jumper ●● Transducer fastening & connection of secondary Primary resistance Primary insertion inductance RP [ mΩ ] LP [ µH ] 0.05 0.025 0.2 1 Recommended PCB connections IN 1 3 5 7 IN 2 1 4 3 6 5 8 7 OUT 2 1 4 3 6 5 8 7 OUT IN 2 4 6 8 OUT 0.1 0.4 Recommended PCB hole ± 0.2 mm 8 pins □ 1.2 mm (corner R 0.4mm) 4 pins 0.5 x 0.25 mm ●● Primary PCB hole ●● Secondary PCB hole Remarks Ø 1.5 mm Ø 0.7 mm ●● VOUT is positive when IP flows from terminals 1,3, 5, 7 (IN) to terminals 2, 4, 6, 8 (OUT). ●● Temperature of the primary conductor should not exceed 120°C. Page 3/3 120416/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com