MTWA16 SERIES 15W Multi-Plug Wall Mount for I.T. Equipment 1 Year Warranty Wide Input Voltage 90 to 264 VAC, 47 to 63Hz Interchangeable AC plug(USA, UK, Europe, Australia) Output Voltage Available From 5VDC Thru 48VDC Single Output Class II Insulation Energy Star 2.0, CEC V, and RoHS compliance Approvals: Single Output Product Number MTWA16-S02 MTWA16-S03 MTWA16-S04 MTWA16-S05 MTWA16-S06 MTWA16-S07 MTWA16-S08 MTWA16-S09 MTWA16-S10 MTWA16-S11 Output Voltage 5 ~ 5.99 VDC 6.5 ~ 8 VDC 8 ~ 11 VDC 11 ~ 13 VDC 13 ~ 16 VDC 16 ~ 21 VDC 21 ~ 27 VDC 27 ~ 33 VDC 33 ~ 40 VDC 40 ~ 48 VDC Max. Output Current 2.40 ~ 2.00 A 1.85 ~ 1.50 A 1.68 ~ 1.22 A 1.36 ~ 1.15 A 1.15 ~ 0.94 A 0.94 ~ 0.72 A 0.72 ~ 0.55 A 0.55 ~ 0.45 A 0.45 ~ 0.37 A 0.37 ~ 0.32 A Total Regulation 5% 5% 5% 5% 5% 5% 3% 3% 3% 3% Maximum Output Power 12W 12W 13.5W 15W 15W 15W 15W 15W 15W 15W Total Regulation is conditioned by below configuration (S02~S04: AWG18/4FT output cable) (S05~S09: AWG20/4FT output cable) (S10~S11: AWG22/4FT output cable) Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) Low Line Inrush Current High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient No-load Power Consumption Test Conditions Universal Input Voltage Operating Voltage Vin=100 to 240VAC Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, 25°C, Cool start, Vin=115VAC Io=Full load, 25°C, Cool start, Vin=230VAC Io=Full Load, Vin=230VAC Io=Full Load Vin=230VAC Nil But, Output protected to short circuit conditions Io=Full Load to Half Load, Vin=100VAC Io=Full Load, Vin=230VAC Io=Full Load, Vin=100VAC Full Load, Vin=90VAC Io=Full Load, Vin=240VAC All output No load, Vin=240VAC Min. 100 90 47 0 74.7 Typ. 25 50 79 0.5 3 Nil Max. 240 264 63 15 0.4 0.26 50 100 85 1 10 4 12 2 0.5 -0.04 0.25 3 1 0.25 0.04 0.3 Unit VAC VAC Hz W A A A A % % % % % mS mS S % mA %/°C W Conditions Parameter Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Temperature at 25°C, Calculated per MIL-HDBK-217F De-rate linearly from 100 % load at 40°C to 50 % load at 70°C Test Conditions Min. 0 -40 0 0 0.1M Typ. 40 Max. 70 85 95 75 Unit °C °C % % Hrs Min. Unit 4242 50 B B VDC MΩ CLASS CLASS Approvals and Compliance Parameter Dielectric Withstanding Voltage for Primary to secondary Isolation Resistance EMI requirements for CISPR-22 EMI requirements for FCC PART-15 Test Conditions Primary to secondary Test Voltage= 500VDC Vin=220VAC Vin=110VAC Mechanical and PIN out Note: 1. Dimensions are shown in mm. 2. Weight: 165g approx. 3. Optional output connector.