TI CD74ACT161ME4 4-bit synchronous binary counter Datasheet

CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
D
D
D
D
D
D
D
CD54ACT161 . . . F PACKAGE
CD74ACT161 . . . E OR M PACKAGE
(TOP VIEW)
Inputs Are TTL-Voltage Compatible
Internal Look-Ahead for Fast Counting
Carry Output for n-Bit Cascading
Synchronous Counting
Synchronously Programmable
SCR-Latchup-Resistant CMOS Process and
Circuit Design
Exceeds 2-kV ESD Protection per
MIL-STD-883, Method 3015
CLR
CLK
A
B
C
D
ENP
GND
description/ordering information
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
RCO
QA
QB
QC
QD
ENT
LOAD
The ’ACT161 devices are 4-bit binary counters. These synchronous, presettable counters feature an internal
carry look-ahead for application in high-speed counting designs. Synchronous operation is provided by having
all flip-flops clocked simultaneously so that the outputs change coincident with each other when so instructed
by the count-enable (ENP, ENT) inputs and internal gating. This mode of operation eliminates the output
counting spikes that normally are associated with synchronous (ripple-clock) counters. A buffered clock (CLK)
input triggers the four flip-flops on the rising (positive-going) edge of the clock waveform.
These devices are fully programmable; that is, they can be preset to any number between 0 and 9 or 15.
Presetting is synchronous; therefore, setting up a low level at the load input disables the counter and causes
the outputs to agree with the setup data after the next clock pulse, regardless of the levels of the enable inputs.
The clear function is asynchronous. A low level at the clear (CLR) input sets all four of the flip-flop outputs low,
regardless of the levels of the CLK, load (LOAD), or enable inputs.
The carry look-ahead circuitry provides for cascading counters for n-bit synchronous applications without
additional gating. Instrumental in accomplishing this function are ENP, ENT, and a ripple-carry output (RCO).
Both ENP and ENT must be high to count, and ENT is fed forward to enable RCO. Enabling RCO produces a
high-level pulse while the count is maximum (9 or 15, with QA high). This high-level overflow ripple-carry pulse
can be used to enable successive cascaded stages. Transitions at ENP or ENT are allowed, regardless of the
level of CLK.
The counters feature a fully independent clock circuit. Changes at control inputs (ENP, ENT, or LOAD) that
modify the operating mode have no effect on the contents of the counter until clocking occurs. The function of
the counter (whether enabled, disabled, loading, or counting) is dictated solely by the conditions meeting the
stable setup and hold times.
ORDERING INFORMATION
PDIP – E
–55°C
55°C to 125°C
ORDERABLE
PART NUMBER
PACKAGE†
TA
SOIC – M
CDIP – F
Tube
CD74ACT161E
Tube
CD74ACT161M
Tape and reel
CD74ACT161M96
Tube
CD54ACT161F3A
TOP-SIDE
MARKING
CD74ACT161E
ACT161M
CD54ACT161F3A
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  2003, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
FUNCTION TABLE
INPUTS
OUTPUTS
CLR
CLK
ENP
ENT
LOAD
A,B,C,D
Qn
RCO
L
X
X
X
X
X
L
L
H
↑
X
X
l
l
L
L
H
↑
X
X
l
h
H
Note 1
H
↑
h
h
h
X
Count
Note 1
H
X
l
X
h
X
Note 1
H
X
X
l
h
X
qn
qn
L
FUNCTION
Reset (clear)
Parallel load
Count
Inhibit
H = high level, L = low level, X = don’t care, h = high level one setup time prior to the CLK
low-to-high transition, l = low level one setup time prior to the CLK low-to-high transition, q = the
state of the referenced output prior to the CLK low-to-high transition, and ↑ = CLK low-to-high
transition.
NOTE 1: The RCO output is high when ENT is high and the counter is at terminal count
(HHHH).
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
logic diagram (positive logic)
LOAD
ENT
ENP
9
10
15
LD†
7
RCO
CK†
CLK
CLR
A
B
C
D
2
1
CK
LD
R
M1
G2
1, 2T/1C3
G4
3D
4R
3
M1
G2
1, 2T/1C3
G4
3D
4R
4
M1
G2
1, 2T/1C3
G4
3D
4R
5
M1
G2
1, 2T/1C3
G4
3D
4R
6
14
13
12
11
QA
QB
QC
QD
† For simplicity, routing of complementary signals LD and CK is not shown on this overall logic diagram. The uses of these signals are shown
on the logic diagram of the D/T flip-flops.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
logic symbol, each D/T flip-flop
LD (Load)
M1
TE (Toggle Enable)
G2
1, 2T/1C3
G4
CK (Clock)
D (Inverted Data)
3D
R (Inverted Reset)
4R
Q (Output)
logic diagram, each D/T flip-flop (positive logic)
CK
LD
TE
LD†
TG
TG
LD†
Q
TG
TG
CK†
D
TG
CK†
R
† The origins of LD and CK are shown in the logic diagram of the overall device.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CK†
TG
CK†
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
typical clear, preset, count, and inhibit sequence
The following sequence is illustrated below:
1. Clear outputs to zero (asynchronous)
2. Preset to binary 12
3. Count to 13, 14, 15, 0, 1, and 2
4. Inhibit
CLR
LOAD
A
Data
Inputs
B
C
D
CLK
ENP
ENT
QA
Data
Outputs
QB
QC
QD
RCO
12
13
14
15
0
1
Count
2
Inhibit
Preset
Async
Clear
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6 V
Input clamp current, IIK (VI < 0 V or VI > VCC) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 V or VO > VCC) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO > 0 V or VO < VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance, θJA (see Note 3): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W
M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 2. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 4)
TA = 25°C
–40°C to
85°C
UNIT
MIN
MAX
MIN
MAX
MIN
MAX
4.5
5.5
4.5
5.5
4.5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level output current
–24
IOL
∆t/∆v
Low-level output current
Input transition rise or fall rate
High-level input voltage
–55°C to
125°C
2
2
0.8
2
V
0.8
V
VCC
VCC
V
–24
–24
mA
24
24
24
mA
10
10
10
ns
VCC
VCC
0.8
V
0
0
VCC
VCC
0
0
V
NOTE 4: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
MIN
VOH
VOL
II
ICC
DICC‡
VI = VIH or VIL
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
–55°C to
125°C
TA = 25°C
MAX
MIN
–40°C to
85°C
MAX
MIN
UNIT
MAX
IOH = –50 µA
IOH = –24 mA
4.5 V
4.4
4.5 V
IOH = –50 mA†
IOH = –75 mA†
5.5 V
IOL = 50 µA
IOL = 24 mA
IOL = 50 mA†
4.5 V
0.1
0.1
0.1
4.5 V
0.36
0.5
0.44
5.5 V
–
1.65
–
IOL = 75 mA†
5.5 V
–
–
1.65
5.5 V
±0.1
±1
±1
µA
5.5 V
8
160
80
µA
2.4
3
2.8
mA
4.4
4.4
3.94
3.7
3.8
–
3.85
–
5.5 V
IO = 0
3.85
4.5 V to
5.5 V
VI = VCC – 2.1 V
V
V
Ci
10
10
10
pF
† Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
‡ Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
A, B, C, or D
UNIT LOAD
0.13
CLK
1
CLR, ENT
0.83
LOAD
0.67
ENP
0.5
Unit Load is ∆ICC limit specified in electrical
characteristics table (e.g., 2.4 mA at 25°C).
timing requirements over recommended operating conditions (unless otherwise noted)
–55°C to
125°C
MIN
fclock
Clock frequency
tw
Pulse duration
tsu
Setup time,
time before CLK↑
th
Hold time,
time after CLK↑
trec
Recovery time, CLR↑ before CLK↑
–40°C to
85°C
MAX
MIN
80
CLK high or low
POST OFFICE BOX 655303
91
6.2
5.4
CLR low
6
5.3
A, B, C, or D
5
4.4
LOAD
6
5.3
A, B, C, or D
0
0
ENP or ENT
0
0
6
5.3
• DALLAS, TEXAS 75265
UNIT
MAX
MHz
ns
ns
ns
ns
7
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
switching characteristics over recommended operating conditions, CL = 50 pF (unless otherwise
noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
fmax
MIN
MAX
80
CLK
tpd
–55°C to
125°C
ENT
CLR
–40°C to
85°C
MIN
UNIT
MAX
91
MHz
RCO
4.2
16.7
4.3
Any Q
4.1
16.5
4.2
15.2
15
RCO
2.7
10.8
2.8
9.8
Any Q
4.1
16.5
4.2
15
RCO
4.1
16.5
4.2
15
TEST CONDITIONS
TYP
ns
operating characteristics, TA = 25°C
PARAMETER
Cpd
8
Power dissipation capacitance
No load
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
66
UNIT
pF
CD54ACT161, CD74ACT161
4-BIT SYNCHRONOUS BINARY COUNTERS
SCHS298B – APRIL 2000 – REVISED MARCH 2003
PARAMETER MEASUREMENT INFORMATION
2 × VCC
S1
R1 = 500 Ω
From Output
Under Test
Open
GND
R2 = 500 Ω
CL = 50 pF
(see Note A)
TEST
S1
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
Open
2 × VCC
GND
tw
3V
NOTE: When VCC = 1.5 V, R1 and R2 = 1 kΩ.
Input
1.5 V
1.5 V
LOAD CIRCUIT
0V
VOLTAGE WAVEFORMS
PULSE DURATION
3V
CLR
Input
3V
Reference
Input
1.5 V
0V
1.5 V
0V
trec
3V
Data
Input 1.5 V
10%
1.5 V
CLK
th
tsu
0V
90%
90%
3V
1.5 V
10% 0 V
tr
VOLTAGE WAVEFORMS
RECOVERY TIME
tf
VOLTAGE WAVEFORMS
SETUP AND HOLD AND INPUT RISE AND FALL TIMES
3V
Input
1.5 V
1.5 V
0V
tPLH
In-Phase
Output
50%
10%
tPHL
90%
90%
tr
tPHL
Out-of-Phase
Output
90%
3V
Output
Control
tPLH
50% VCC
10%
tf
50%
10%
VOH
Output
50% VCC
Waveform 1
10%
VOL S1 at 2 × V
CC
tf
(see Note B)
90%
VOH
VOL
tr
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
1.5 V
1.5 V
0V
tPLZ
tPZL
50% VCC
tPZH
Output
Waveform 2
S1 at Open
(see Note B)
50% VCC
≈VCC
VOL + 0.3 V
VOL
tPHZ
VOH
VOH – 0.3 V
≈0 V
VOLTAGE WAVEFORMS
OUTPUT ENABLE AND DISABLE TIMES
NOTES: A. CL includes probe and test-fixture capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
Phase relationships between waveforms are arbitrary.
D. For clock inputs, fmax is measured with the input duty cycle at 50%.
E. The outputs are measured one at a time with one input transition per measurement.
F. tPLH and tPHL are the same as tpd.
G. tPZL and tPZH are the same as ten.
H. tPLZ and tPHZ are the same as tdis.
I. All parameters and waveforms are not applicable to all devices.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
PACKAGE OPTION ADDENDUM
www.ti.com
18-Jul-2006
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
CD54ACT161F3A
ACTIVE
CDIP
J
16
1
TBD
A42 SNPB
N / A for Pkg Type
CD74ACT161E
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
CD74ACT161EE4
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
CD74ACT161M
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT161M96
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT161M96E4
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT161ME4
ACTIVE
SOIC
D
16
CU NIPDAU
Level-1-260C-UNLIM
Package
Drawing
Pins Package Eco Plan (2)
Qty
40
Green (RoHS &
no Sb/Br)
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Low Power Wireless www.ti.com/lpw
Mailing Address:
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2006, Texas Instruments Incorporated
Similar pages